INSTALLATION INSTRUCTIONS
HRO-500 AND HRO-500C REVERSE OSMOSIS SYSTEM
- NOTICE -
This Manual is prepared for the use of trained Hobart Service Technicians and should not be used by those not properly qualified.
This manual is not intended to be all encompassing. If you have not attended a Hobart Service School for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the necessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should be performed by a trained Hobart Service Technician.
The reproduction, transfer, sale or other use of this Manual, without the express written consent of Hobart, is prohibited.
This manual has been provided to you by ITW Food Equipment Group LLC ("ITW FEG") without charge and remains the property of ITW FEG, and by accepting this manual you agree that you will return it to ITW FEG promptly upon its request for such return at any time in the future.
A product of Hobart Service 701 S. Ridge Ave Troy, OH 45374
F45580 Rev A. (0915)
HRO-500 AND HRO-500C REVERSE OSMOSIS SYSTEM
INTRODUCTION
INSTALLATION INSTRUCTIONS
Features
Four stage reverse osmosis system utilizing standard incoming feed water pressure.
No electricity or feed-side pump required.
Ideal for high-volume, line-pressure applications.
No hydraulic shut-off valve required.
Features a permeate pump powered by the hydraulic energy of the brine water.
The permeate pump optimizes system efficiency by keeping the pressurized storage tank close to line pressure, which allows large draws on demand.
Dual carbon block or dual chloramines reduction prefilters.
Carbon/calcite postfilter.
Compact wall-mounted frame. Easy to install with quick connect fittings.
Manufactured in the USA.
Fig. 1
System Specifications
Model HRO-500 HRO-500C
Capacity* 500 gpd
Membrane (1) 3.2” x 18”
Prefilter (2) 20” Carbon block (2) 20” Chloramines reduction
Postfilter 12” Carbon/Calcite
Dimensions 28”H x 14”W x 7”D
Weight 28 lbs.
* Based on membrane performance after 24 hours, 77°F, 500 ppm TDS at 65 psi. Membrane performance may vary ±15%.
Operating Specifications
Minimum Feed Pressure 25 psi
Operating Pressure 40-80 psi
Operating Temperature 40°F - 100°F