Henny Penny SCD-6, SCD-8 Operation Manual

3-1. OPERATING
INSTRUCTIONS
Model SCD-6/8
SECTION 3. OPERATION
Before using, the unit should be thoroughly cleaned as indi­cated in the Cleaning Instructions Section of this manual.
1. T o put the SCD into operation, turn the POWER switch to the ON position. The display shows the setpoint temperature.
2. Once the unit has heated up, the temperature LED comes on and product can now be loaded into the unit.
3. Once product is loaded into the unit, press the TIMER button to start the timer .
4. At the end of the timing cycle, the display flashes “00:00” and the timer LED flashes. Press the TIMER button to end the cycle.
If humidity is desired, water may be added to the drip pan.
Press and hold the TEMP button at any time to view the actual cabinet temperature.
203 3-1
3-2. CLEANING 1. Turn controls to OFF position.
INSTRUCTIONS
2. Disconnect electrical supply to the cabinet.
To avoid severe burns, allow the unit to cool before
cleaning.
3. Open doors and remove all racks, and drip pan from unit.
4. Clean racks, and drip pan thoroughly.
5. Clean the interior and exterior with a soft cloth, soap and water.
Model SCD-6/8
Do not use steel wool, other abrasive cleaners, or cleaners/sanitizers containing chlorine, bromine, iodine, or ammonia chemicals, as these will deteriorate the stainless steel, and glass material, and shorten the life of the unit. DO NOT USE ABRASIV
E CLEANERS, OR CLEANERS Do not use a water jet (pressure sprayer) to clean the unit,
or component failure could r esult.
6. Wipe control panel with a damp cloth.
7. Leave doors open overnight to allow thorough drying.
3-3. PROGRAMMING INSTRUCTIONS Temperature Setpoint
1. Press and hold the TEMP button for 6 seconds. The
actual temperature shows first followed by the flashing setpoint. (If display shows “LOC” see Special Program Mode section.)
2. Once the setpoint is flashing, continue to hold the TEMP button and press the UP and DOWN buttons to set the desired temperature.
3. Release the TEMP button and the control regulates the temperature to the new setpoint.
3-2 203
Loading...