Henny Penny OFE-321, OFG-321, OFE-322, OFG-322, OFE-323 Operation Manual

...
Model OFE/OFG-321,322,323,324
This manual should be retained in a convenient location for future reference.
A wiring diagram for this appliance is located on the inside of the right side panel.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance must be left all around
appliance for sufficient air to the combustion chamber.
The Model OFG/OGA-32X open fryer is equipped with a continuous pilot. But the open fryer cannot be operated without electric power. The unit will automatically return to normal operation when power is restored.
To avoid a fire, keep appliance area free and clear from combustibles.
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FIRE OR
EXPLOSION COULD RESULT.
Model OFE/OFG-321,322,323,324
Technical Data for CE/AGA Marked Products
Nominal Heat Input: Natural (I2H) = 24.9 KW (85,000 Btu/h) (Net) Natural (I Natural (I Natural (I2L) = 24.9 KW (85,000 Btu/h) Liquid Propane (I
Nominal Heat Input: Natural (I (Gross) Natural (I2E) = 27.7 KW (94,500 Btu/h) Natural (I2E+) = 27.7 KW (94,500 Btu/h) Natural (I2L) = 27.7 KW (94,500 Btu/h) Liquid Propane (I
Supply Pressure: Natural (I Natural (I Natural (I Natural (I2L) = 25 mbar Liquid Propane (I3P) = 30 mbar Liquid Propane (I3P) = 37 mbar (3.7 kPa) Liquid Propane (I3P) = 50 mbar (5.0 kPa)
Test Point Pressure: Natural (I2H) = 8.7 mbar (0.87 kPa) Natural (I2E) = 8.7 mbar Natural (I2E+) = 8.7/10 mbar Natural (I2L) = 10 mbar Liquid Propane (I3P) = 24.5 mbar (2.5 kPa)
Injector Size: Natural (I Natural (I Natural (I Natural (I Liquid Propane (I
Restrictor Size: Natural (I
This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force and only used in a suitably ventilated location. Read the instructions fully before installing or using the appliance.
Noise generated from this equipment is less than 70 dB(A)
) = 24.9 KW (85,000 Btu/h)
2E
+) = 24.9 KW (85,000 Btu/h)
2E
) = 24.9 KW (85,000 Btu/h)
3P
) = 27.7 KW (99.70 MJ/h) (94,500 Btu/h)
2H
) = 27.7 KW (99.70 MJ/h) (94,500 Btu/h)
3P
) = 20 mbar (2.0 kPa)
2H
) = 20 mbar
2E
+) = 20/25 mbar
2E
) = 3.26 mm
2H
) = 3.26 mm
2E
+) = 3.26 mm
2E
) = 3.26 mm
2L
) = 1.93 mm
3P
+) = 4.6 mm
2E