Haier H3FM-H03-R2, 3HUM20H03-R2 Manual

0 (0)

FLOOR UNIT ROOM AIR CONDITIONER

OPERATION MANUAL

Please read this operation manual before using the air conditioner.

No.0010509578

Cautions

Disposal of the old air conditioner

Safety Instructions and Warnings

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled

.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

1

Cautions

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum:D.B/W.B

32oC/23oC

Cooling

Minimum:D.B/W.B

18oC/14oC

Outdoor

Maximum:D.B/W.B

43oC/26oC

 

 

Minimum:D.B

18oC

 

Indoor

Maximum:D.B

27oC

 

Minimum:D.B

15oC

Heating

 

Outdoor

Maximum:D.B/W.B

24oC/18oC

 

 

 

Minimum:D.B/W.B

-15oC

2.If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse of indoor unit on PC board is broken,please change it with the type of

T.3.15A/ 250V. If the fuse of outdoor unit is broken, change it with the type of T.25A/250V.

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised to ensure that they do not play with the appliance.

9.A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm.

10.Please employ the proper power plug, which fit into the power supply cord.

11 .The power plug and connecting cable must have acquired the local attestation.

12.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power.

2

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

Installation in a inadequate place may cause accidents. Do not install in the following place.

securely CAUTION

Connect the earth

Do not install in the

cable.

place where there is

 

any possibility of

 

inflammable gas

 

leakage around the

 

unit.

earthing

PROHIBITION

 

Use fuse with specified capacity. Replacement with steel or copper wires are absolutely prohibited.

Do not get the unit

Check proper

exposed to vapor

installation of the

or oil steam.

drainage

STRICT

PROHIBITION ENFORCEMENT

Grounding wire should not be connected to that of gas pipeline, water pipeline, lighting arrester or telephone.

FUSE

COPPERWIRE

STEEL WIRE

3

Haier H3FM-H03-R2, 3HUM20H03-R2 Manual

Cautions

WARNING

When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.

OFF

STRICT

ENFORCEMENT

Use an exclusive power source with a circuit breaker

Connect power supply cord

After installed, the unit shall be

Do not use power supply cord

to the outlet completely

tested for electric leakage.

extended or connected in halfway

STRICT

STRICT

PROHIBITION

ENFORCEMENT

ENFORCEMENT

 

Do not use power supply cord

Take care not to damage

Do not insert objects into the air

in a bundle.

the power supply cord.

inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

Do not start or stop the

Do not channel the air flow directly

Do not try to repair or reconstruct

operation by disconnecting

at people, especially at infants or

by yourself.

the power supply cord and so on.

the aged.

 

PROHIBITION

PROHIBITION

 

 

CAUTION

 

Do not use for the purpose of storage of

Take fresh air occasionally especially

Do not operate the switch with

food, art work, precise equipment,

when gas appliance is running at the

wet hand.

breeding, or cultivation.

same time.

 

 

STRICT

PROHIBITION

PROHIBITION

ENFORCEMENT

Do not install the unit near a fireplace

Check good condition of the

Do not pour water onto the unit

or other heating apparatus.

installation stand

for cleaning

PROHIBITION

PROHIBITION

PROHIBITION

Do not place animals or plants in

Do not place any objects on or

Do not place flower vase or water

the direct path of the air flow

climb on the unit.

containers on the top of the unit.

 

PROHIBITION

PROHIBITION

PROHIBITION

4

Parts and Functions

Indoor unit

1.OUTLET 2.CONTROL PANEL 3.INLET

4.FILTER (inside) 5.OUTLET

Outdoor unit

OUTLET

CONNECTING PIPING AND ELECTRICAL WIRING

INLET

DRAIN HOSE

5

Parts and Functions

CAUTION

Before opening the front grille, be sure to stop the operation and turn the breaker OFF.

Do not touch the metal parts on the inside of the indoor unit, as it may result in injury.

ON/OFF button

Push once to start operation, push once again to stop it.

Operation is set to AUTO, air flow is set to AUTO FAN.

Use when remote controller is not available.

Indoor temperature sensor

Senses the air temperature around the unit.

Air flow selection

Make air flow selection according to what suits you.

When setting the air flow selection switch to

Air conditioner automatically decides the appropriate blowing pattern depending on the operating mode/situation.

During Dry mode, so that cold air does not come into direct contact with people, air is blown upper air outlet.

When setting the air outlet selection switch to

Regardless of the operating mode or situation, air blows from the upper air outlet.

Use this switch when you do not want air coming out of the lower air outlet. (While sleeping etc..)

6

Receiver

Signals are received from the remote controller here.

Upon receiving a signal, there is a receiving sound.

Air outlet selection switch

This setting blows air from upper outlet only.

This setting automatically decides a blow pattern depending on mode and conditions.

This setting is recommended.

Air outlet selection

Operating

Situation

Blowing pattern

mode

 

 

 

 

 

 

When the room has

So that air does not come

 

become fully cool .

into direct contact with

 

 

people, air is blown upper air

 

 

outlet, room temperature is

Cool

 

equalised

mode

 

 

 

At start of operation

 

 

or other times when

Air is blown from the upper and

 

the room is not fully

 

lower air outlets for high speed

 

cooled.

 

cooling during Cool mode, and

 

 

 

 

for filling the room with warm

 

 

 

At times other than

air during Heat mode.

 

 

 

below. (Normal

 

 

time.)

 

Heat

 

 

mode

At start or when air

So that air does not come into

 

 

temperature is low.

direct contact with people. Air

 

 

is blown upper air outlet.

 

 

 

Parts and Functions

Remote Controller

1.TIMER

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF

2.HOUR

Used to set clock and timer setting.

3.CLOCK

Used to set correct time.

Note:

1.The following functions and related displays are not available for all models: Display of humidifying and atmosphere humidity.

2.There is health display with the remote controller in this type, but without health function.

4.MODE

Used to select AUTO, COOL, DRY, FAN and HEAT operation.

5.ON/OFF

Used for unit start and stop.

6.SWING

Used to adjust the up/down air flow direction.

7. TEMP.

Used to select your desired temperature.

8.TIMER ON display

9.SLEEP display

10.FAN SPEED display

Remote controller:

LOW

MED

HI

AUTO

11. SWING UP/DOWN display

 

 

 

12. MODE display

 

 

 

 

Operation

Remote

 

 

mode

controller

 

AUTO

 

 

 

 

 

 

 

COOL

DRY

FAN

HEAT

13.SIGNAL SENDING display

14.TEMP. display

Remote controller: to display the TEMP. setting.

15.CLOCK display

16.TIMER OFF display

17.FAN

Used to select fan speed: LO,MED,HI,AUTO

18.SET

Used to confirm timer and clock settings.

19.SLEEP

Used to select sleep mode.

20.RESET

When the remote controller appears abnormal, use a sharp pointed item to press this button

to reset the remote controller to normal condition.

21.LOCK

Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears.

Press it once again, lock will be canceled and lock condition display disappears.

22.LOCK display

23.POWER/SOFT

7

Loading...