GW Instek GPD-3303S, GPD-3303D Instruction Manual

This manual contains proprietary information, which is protected by
copyrights. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
rights to change specification, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan.
ISO-9001 CERTIFIED MANUFACTURER
DC Power Supply
GPD-3303 Series
USER MANUAL
GW INSTEK PART NO.
Error Messages ....................................27H38
Command List......................................28H39
GPD-3303 Series User Manual
Command Details ................................ 29H40
Fuse Replacement................................ 32H46
Specifications ......................................33H47
Declaration of Conformity.................... 34H49
FAQ................................................................................30H45
APPENDIX......................................................................31H46
INDEX ............................................................................35H50
4
3
TABLE OF CONTENTS
Table of Contents
Introduction........................................... 9
Series Lineup / Main Features ............. 11
Principle of Operation.......................... 12
Front Panel Overview........................... 14
Rear Panel Overview ............................ 17
CV/CC Crossover Characteristics ......... 18
SAFETY INSTRUCTIONS .................................................. 5
OVERVIEW....................................................................... 9
Power Up ............................................. 19
Load Cable Connection ........................ 20
Output On/Off..................................... 21
Beep On/Off ........................................ 21
Front Panel Lock ..................................22
SETUP ........................................................................... 19
CH1/CH2 Independent Mode .............. 23
CH3 Independent Mode....................... 25
CH1/CH2 Tracking Series Mode........... 27
CH1/CH2 Tracking Parallel Mode ........19H32
OPERATION .................................................................. 23
Save Setup ...........................................21H34
Recall Setup......................................... 22H35
SAVE/RECALL SETUP ..................................................... 20H34
Remote Control Setup.......................... 24H36
Remote Connection Step...................... 25H37
Command Syntax ................................. 26H38
REMOTE CONTROL....................................................... 23H36
source of low-voltage installation.
building installation.
circuits directly connected to the low voltage installation.
series.
GPD-3303 Series User Manual
Do not place any heavy object on the GPD-3303
Avoid severe impacts or rough handling that
leads to damaging the GPD-3303 series.
Do not discharge static electricity to the GPD-
3303 series.
opening.
connected to Mains (see note below).
you are qualified as service personnel.
Do not block or obstruct the cooling fan vent
Do not perform measurement at circuits directly
Do not disassemble the GPD-3303 series unless
(Measurement categories) EN 61010-1:2001 specifies the
measurement categories and their requirements as follows. The
GPD-3303 series falls under category I.
Measurement category IV is for measurement performed at the
Measurement category III is for measurement performed in the
Measurement category II is for measurement performed on the
circuits not directly connected to Mains.
±10%, 50/60Hz
the AC power cord to an earth ground, to avoid
electrical shock.
Measurement category I is for measurements performed on
AC Input voltage: 100V/120V/220V/230V
Connect the protective grounding conductor of
220V/230V: T3.15A/250V
before power up.
Fuse type: 100V/120V: T6.3A/250V,
Make sure the correct type of fuse is installed

Safety Guidelines

General
CAUTION
Guidelines
WARNING
Power Supply
WARNING
Fuse
6
5
SAFETY INSTRUCTIONS
This chapter contains important safety instructions
that you must follow when operating the GPD-
3303 series and when keeping it in storage. Read
the following before any operation to insure your
safety and to keep the best condition for the GPD-
SAFETY INSTRUCTIONS
3303 series.

Safety Symbols

These safety symbols may appear in this manual or on the GPD-3303
Warning: Identifies conditions or practices that
could result in injury or loss of life.
Caution: Identifies conditions or practices that
could result in damage to the GPD-3303 series or
WARNING
to other properties.
CAUTION
Attention Refer to the Manual
DANGER High Voltage
Protective Conductor Terminal
Earth (ground) Terminal
series.
or coloured Green or
should be protected by a 3A
2
Location: Indoor
Relative Humidity: < 70%
environment
Temperature: 10°C to 70°C

Power cord for the United Kingdom

When using the GPD-3303 series in the United Kingdom, make sure
WARNING: THIS APPLIANCE MUST BE EARTHED
Green/ Yellow: Earth
Blue: Neutral
the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
IMPORTANT: The wires in this lead are coloured in accordance with the
following code:
Brown: Live (Phase)
As the colours of the wires in main leads may not correspond with the colours
marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth
Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is
terminal marked with the letter E or by the earth symbol
marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked
with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact the
supplier.
This cable/appliance should be protected by a suitably rated and approved HBC
mains fuse: refer to the rating information on the equipment and/or user
instructions for details. As a guide, cable of 0.75mm
or 5A fuse. Larger conductors would normally require 13A types, depending on
the connection method used.
Any moulded mains connector that requires removal /replacement must be
destroyed by removal of any fuse & fuse carrier and disposed of immediately, as
a plug with bared wires is hazardous if a engaged in live socket. Any re-wiring
must be carried out in accordance with the information detailed on this label.
8
GPD-3303 Series User Manual
Storage
with the specified type and rating.
replacement.
To ensure fire protection, replace the fuse only
SAFETY INSTRUCTIONS
Disconnect the power cord before fuse
before fuse replacement.
Make sure the cause of fuse blowout is fixed
7
pollution occurs. The pollution has no influence.
occurs. Occasionally, however, a temporary conductivity caused
by condensation must be expected.
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment
is normally protected against exposure to direct sunlight,
precipitation, and full wind pressure, but neither temperature
detergent and water. Do not spray any liquid.
harsh products such as benzene, toluene, xylene,
and acetone.
Disconnect the power cord before cleaning.
Use a soft cloth dampened in a solution of mild
Do not use chemicals or cleaners containing
almost non-conductive pollution (note below)
Location: Indoor, no direct sunlight, dust free,
Relative Humidity: < 80%
Altitude: < 2000m
Temperature: 0°C to 40°C (Pollution Degree) EN 61010-1:2001 specifies the pollution degrees
and their requirements as follows. The GPD-3303 series falls under
degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
Pollution degree 2: Normally only non-conductive pollution
Pollution degree 3: Conductive pollution occurs, or dry, non-
nor humidity is controlled.
Cleaning the
GPD-3303 series
Operation
Environment
The front panel display (CH1, CH2) shows the
output voltage or current. When operating in the
tracking mode, the power supply will
tracking mode
automatically connect to the auto- tracking mode.
When used in audio production lines, the power
supply will provide a continuous or dynamic load
connector. When the connectors are connected to
the position “ON”, a stable DC current power will
be provided for audio power amplifiers.
Dynamic load
10
Except for CH3, each output channel is completely
transistorized and well-regulated, and works in
constant voltage (CV) or constant current (CC)
mode. Even at the maximum output current, a
fully rated, continuously adjustable output voltage
is provided. For a big load, the power supply can
be used as a CV source; while for a small load, a
CC source. When in the CV mode (independent or
tracking mode), output current (overload or short
circuit) can be controlled via the front panel. When
in the CC mode (independent mode only), the
maximum (ceiling) output voltage can be
controlled via the front panel. The power supply
will automatically cross over from CV to CC
operation when the output current reaches the
target value. The power supply will automatically
cross over from CC to CV when the output voltage
reaches the target value. For more details about
GPD-3303 Series User Manual
Constant Voltage/
Constant Current
CV/CC mode operation, see page18.
utomatic A
OVERVIEW
This chapter describes the GPD-3303 series in a
nutshell, including its main features and front /
rear panel introduction. After going through the
perly power up and set operation environment.
overview, follow the Setup chapter (page19) to
pro
GPD-3303, the regulated DC power supply series,
are light weight, adjustable, multifunctional work
stations. They have three independent outputs:
two with adjustable voltage level and one with
fixed level selectable from 2.5V, 3.3V and 5V. The
GPD-3303 series can be used for logic circuits
where various output voltage or current are
needed, and for tracking mode definition systems
where plus and minus voltages with insignificant
error are required.
The three output modes of GPD-3303 series,
independent, tracking series, and tracking parallel,
can be selected through pressing the TRACKING
key on the front panel. In the independent mode,
the output voltage and current of each channel are
controlled separately. The isolation degree, from
output terminal to chassis or from output terminal
to output terminal, is 300V. In the tracking modes,
both the CH1 and CH2 outputs are automatically
connected in series or parallel; no need to connect
output leads. In the series mode, the output
voltage is doubled; in the parallel mode, the
output current is doubled.
9
OVERVIEW

Introduction

Overview
Independent /
Trac ki ng S er ie s /
Tracking Parallel
pre-regulator and reference voltage source
rectifier and filter, series regulator, current
comparator, voltage comparator, reference
voltage amplifier, remote device and relay
control circuit
AC input circuit
Transformer
Bias power supply including rectifier, filter,
GPD-3303 Series User Manual
The power supply consists of the following.
Main regulator circuit including the main
The block diagram below shows the circuit
arrangement. The single phase input power is
connected to the transformer through the input
circuit. Details of each part are described in the
next page.

Principle of Operation

Overview
Block diagram
0.5% + 50mV of Master
0.5% + 10mV of Master
12
11
OVERVIEW

Series Lineup / Main Features

Series Lineup

Model V Meter A Meter USB Tracking Error
GPD-3303D 3 digit 3 digit Yes
temperature
Low noise: Cooling fan controlled by Heatsink
GPD-3303S 5 digit 4 digit Yes

Main Features

Performance
Compact size, light weight
Constant Voltage / Constant Current operation
Tracking Series / Tracking parallel operation
Output On/Off control
3 outputs: 30V/3A x 2, 2.5V/3.3V/5V/3A x 1
Digital panel control
4 sets of panel setup save/recall
Coarse and fine Voltage/Current control
Software calibration
Buzzer output
Key lock function
Overload protection
Reverse polarity protection
USB for remote control
Operation
Protection
Interface
GPD-3303D (3 digits)
GPD-3303 Series User Manual

Front Panel Overview

Displays CH1 or CH2 output voltage.
Display
Vol tMeter
GPD-3303S (5 digits)
GPD-3303D (3 digits)
Displays CH1 or CH2 output current.
AmpMeter
GPD-3303S (4 digits)
14
The auxiliary rectifiers D1011~ D1014 provide bias
voltage filtered by the capacitors C102 and C103,
OVERVIEW
for the pre-regulators U101 and U102. They
provide a regulated voltage for other modules.
The main rectifier is a full wave bridge rectifier. It
provides the power after the rectifier is filtered by
13
the capacitor C101, and then regulated via a series-
wound regulator, which is finally delivered to the
output terminal.
U104 acts as a current limiter. When the current is
over predetermined rating, U104 is activated and
decreases the current. U208 provides a reference
voltage. U206 is the inverter amplifier. U103 is a
comparator amplifier which compares reference
voltage and feedback voltage, and then delivers to
Q103, Q104, which then calibrates the output
voltage.
When the unit is overloaded, Q107 activates to
control the current magnitude of Q104, to limit the
output current. The relay control circuit controls
the power dissipation in the series-wound
regulated circuit.
Rectifier
Main Rectifier
Current Limiter
Overload
European Terminals
Indicates CH1 Constant Voltage or
Accepts a grounding wire.
Outputs CH1 voltage and current.
Constant Current state.
Outputs CH2 voltage and current.
Indicates CH2 Constant Voltage,
Constant Current, or Tracking
Outputs CH3 voltage and current.
Parallel operation mode.
Indicates when CH3 output current is
overloaded.
Selects CH3 output voltage: 2.5V,
3.3V, or 5V.
GPD-3303 Series User Manual
Te rm in al s
Default Terminals
GND Terminal
CH1 Output
CH1 CV/CC
Indicator
42H22.
CH2 Output
CH2
CV/CC/PAR
Indicator
CH3 Overload
CH3 Output
Indicator
CH3 Voltage
43H19.
Selector
16
15
or Off the main power.
key enables beep sound. For
Activates Tracking Parallel operation
or Tracking Series operation, For
details, see page27.
Locks or unlocks the front panel
Saves or recalls panel settings. Four
settings, 1 ~ 4, are available. For
save/recall details, see page34.
see page23. Pressing and holding
CH2
details, see page21.
Selects the output channel for level
adjustment. For level setting details,
settings. For details, see page
Turns the output on or off.
Adjusts the output voltage level for
CH1 or CH2. Pressing the knob
switches coarse and fine level setting.
Adjusts the output current level for
CH1 or CH2. Pressing the knob
switches coarse and fine level setting.
Turns On
For power up sequence, see page
OVERVIEW
Control Panel
Memory Keys
CH2/Beep
Keys
CH1/
l/Series
Paralle
Keys
Lock Key
Output Key
Vol t a g e K nobs
Current Knobs
Power Switch
Loading...
+ 18 hidden pages