GW Instek GOC-6200 Data Sheet

200MHz CURSOR READOUT ANALOG OSCILLOSCOPE
The GOS-6200 is a 200MHz two-channel, dual-trace, portable oscilloscope designed for general purpose use. A microprocessor-based operating system controls most of the functions of the instrument, including cursor readout and convenient digitized panel settings. On-screen alphanumeric readout and cursor functions are provided for voltage, time, frequency and phase measurement to extraordinary operational convenience. It also has the function of TV Line select for trigger settings for NTSC, PAL and SECAM. Auto-measurements include frequency, period, pulse width and duty cycle with auto-setting function. Ten different user defined instrument settings can be saved and recalled without restriction.
OSCILLOSCOPES
The vertical deflection system has two input channels, each with 11 different basic deflection factors from 2mV to 5V per division. The horizontal deflection system provides single, dual or delayed sweeps from 20ns to 0.5s per division (delayed sweep, 50ms to 20ns per division). The trigger system provides
GOS-6200 (200MHz)
stable triggering over the full bandwidth of the vertical deflection.
FEATURES
* 200MHz Bandwidth, Dual Channel, Delayed Sweep * Auto Set * Built-in 6 digits Universal Counter * Cursor Readout with 7 Measurements * 10 Sets Memory for Front Panel Setting Save & Recall * TV-Line Selection (NTSC, PAL, SECAM) * Panel Setup Lock of Digital-Control Functions * Buzzer Alarm * LED Indicators * Trigger Signal Output
* Z-axis Modulation Input * SMD Technology, High Stability and Reliability
CRT Type
Accelerating Potential Illumination Z-axis input
VERTICAL SYSTEM
Sensitivity Sensitivity Accuracy Vernier Vertical Sensitivity Bandwidth(-3dB) Rise Time Signal Delay Max. Input Voltage Input Coupling Input Impedance Vertical Mode Bandwidth Limited Common-Mode Rejection Ratio Dynamic Range
HORIZONTAL SYSTEM
Horizontal Modes A(main) Sweep Time B(delay) Sweep Time Accuracy Sweep Magnification Hold Off Time Delay Time Delay Jitter Alternate Separation
TRIGGER
Trigger Modes Trigger Source Trigger Coupling Trigger Slope
Trigger Sensitivity
Trigger Level Range TV Triggering
TV-Line Selection
Max. External Input Voltage External Input Impedance
X-Y OPERATION
Mode Sensitivity Accuracy X-axis Bandwidth Phase Error
6-inch rectangular type with internal graticule; 8 x 10 div (1 div = 1 cm) 14 kV approx. Continuously adjustable Coupling : DC Sensitivity: 5V or more Maximum input voltage : 30V (DC + AC peak) at 1kHz or less Bandwidth : DC ~ 5 MHz
2mV~5V/div, 11 step in 1-2-5 sequence
_
<
3% (5div at the center of display) Continuously variable to 1/2.5 or less of panel-indicated value DC~200MHz (5mV/div:DC~150MHz) ; (2mV/div:DC~20MHz)
1.75ns (5mV/div:2.33ns, 2mV/div:17.5ns) Leading edge can be monitored 400V(DC+AC peak) at 1kHz or less AC, DC, GND
+
1M 2% // approx. 25pF
_
CH1,CH2,DUAL(CHOP/ALT), ADD, CH2 INV. 20MHz 50:1 or better at 50kHz 8 div at 100MHz; 5div at 200MHz
MAIN(A), ALT, DELAY(B) 20ns~0.5s/div, continuously variable (UNCAL) 20ns~50ms/div
+ +
_ _
3% ( 5% at x 10 MAG) x 10 (maximum sweep time 2ns/div) Variable 1 s~5s Better than 1:20000 Variable
AUTO, NORM, TV CH1, CH2, LINE, EXT, EXT/10 AC, DC, HFR, LFR, NR "+" or "-" polarity or TVsync polarity
Mode
AUTO
NORM
TV
_
+
INT : 4div or more; EXT : 0.4V or more; EXT/10 : 4V or more Mode : TV-V, TV-H, TV-LINE
NTSC (525H) PAL (625H)
SECAM (625H)
400V(DC+AC peak) at 1kHz
_
+
1M 5% // approx.25pF
W
X-axis: selectable CH1, EXT, EXT/10 ; Y-axis: selectable CH1, CH2, CH1 and CH2 2mV~5V/div 3%;EXT : 0.1V/div 5%; EXT/10 : 1V/div 5% DC~500kHz(-3dB) 3 or less from DC~50kHz
Frequency
10 Hz ~ 20 MHz 20 MHz ~ 200 MHz
DC ~ 20 MHz 20 MHz ~ 200 MHz
sync signal
Standard
_
+
_
+
_
+
0%, 10%, 90% and 100% markers
INT
0.35 div
1.5 div
0.35 div
1.5 div 1 div
Field 1
1H ~ 263H
1H ~ 313H 1H ~ 312H
EXT
50 mV
150 mV 1.5 V
50 mV
150 mV
200 mV
_
+
_
+
pp
Field 2
1H ~ 262H
EXT/10
500 mV
500 mV
1.5 V
2 V
pp
A27
SPECIFICATIONSSPECIFICATIONS
OUTPUT SIGNAL
Trigger Signal Output Calibrator Output
CURSOR READOUT FUNCTION
Cursor Measurement Function
Cursor Resolution Effective Cursor Range Panel Setting Display
AUTO MEASUREMENT FUNCTION
Parameter Function Display Digits Frequency Range Accuracy Measuring Sensitivity
SPECIAL FUNCTION Auto Set
Panel Setting Save & Recall Panel Setups Lock
POWER SOURCE
AC 100V/120V/230V 10% , 50/60Hz
DIMENSIONS & WEIGHT
310(W) x 150(H) x 470(D) mm ; Approx. 9kg
Voltage : approx. 25mV/div into 50 ; 1kHz square wave, 2Vpp 2%
V, V%, VdB, T, 1/ T, T%, 1/100 div
_
+
Vertical: 3div; Horizontal: 4 div Vertical: V/div(CH1,CH2),UNCAL,ALT/CHOP/ADD,INV, probe factor,AC/DC/GND Horizontal: s/div(MTB, DTB), UNCAL, x 10MAG, delay time , Hold-off Trigger: source, coupling, slope, level, TV-V, TV-H Others: X-Y, lock, save/recall MEM 0-9
FREQ, PERIOD, WIDTH, DUTY (+ or - polarity selected by trigger slope) Max. 6-digits, decimal 50Hz ~ 200MHz 1kHz ~ 200MHz : 0.01%; 50Hz ~ 1kHz : 0.05% > 2 DIV (Measuring source selected from CH1 and CH2 as synchronous signal sources)
Input Channel: CH1, CH2; Frequency Response 50Hz ~50MHz 10 sets Provided
_
+
GOS-6200
_
+
_
+
_
_
+
+
_
+
Frequency response : DC ~ 10MHz
_
+
AUTO AND CURSOR MEASUREMENT FUNCTIONS
AUTO Mode : Frequency
RISE Time ( T)
AUTO Mode : Period
Voltage ( V)
AUTOSET FUNCTION
OSCILLOSCOPES
ORDERING INFORMATION
GOS-6200
ACCESSORIES : User manual x 1, Power cord x 1
Probe-GTP-250A : 250MHz ( 10 : 1/1 :1 ) Switchable Passive Probe (one per channel)
OPTIONAL ACCESSORIES
GTC-001 Instrument Cart, 450(W) x 430(D) mm (120V Input Socket) GTC-002 Instrument Cart, 330(W) x 430(D) mm (120V Input Socket)
GTL-110 Test Lead, BNC-BNC Heads
200MHz Cursor Readout Analog Oscilloscope
Before AUTOSET
Screen after unknown signal input.
After AUTOSET
Optimum screen display after pressing a button.
TV-H, TV-V, FIELD/LINE SELECTOR
TV - H
Made to Measure. Good Will Instrument Co., Ltd.
TV - L
A28
Loading...