WARNING:THIS UNIT IS INTENDED FOR USE IN THE COMMERCIAL HEATING, COOKING AND
HOLDING OF WATER AND FOOD PRODUCTS, PER THE INSTRUCTIONS
CONTAINED IN THIS MANUAL. ANY OTHER USE COULD RESULT IN SERIOUS
PERSONAL INJURY OR DAMAGE TO THE EQUIPMENT AND WILL VOID
WARRANTY.
WARNING:KETTLE MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY. IMPROPER INSTALLATION CAN RESULT IN INJURY TO
PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
DANGER:ELECTRICALLY GROUND THE UNIT AT THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN ELECTROCUTION AND DEATH.
WARNING:AVOID ALL DIRECT CONTACT WITH HOT EQUIPMENT SURFACES. DIRECT SKIN
CONTACT COULD RESULT IN SEVERE BURNS.
WARNING:AVOID ALL DIRECT CONTACT WITH HOT FOOD OR WATER IN THE KETTLE.
DIRECT CONTACT COULD RESULT IN SEVERE BURNS.
CAUTION:DO NOT OVER FILL THE KETTLE WHEN COOKING, HOLDING OR CLEANING.
KEEP LIQUIDS A MINIMUM OF 2-3” (5-8 cm) BELOW THE KETTLE BODY RIM TO
ALLOW CLEARANCE FOR STIRRING, BOILING AND SAFE PRODUCT TRANSFER.
WARNING:TAKE SPECIAL CARE TO AVOID CONTACT WITH HOT KETTLE BODY OR HOT
PRODUCT WHEN ADDING INGREDIENTS, STIRRING OR TRANSFERRING
PRODUCT TO ANOTHER CONTAINER.
WARNING:WHEN TILTING KETTLE FOR PRODUCT TRANSFER:
1) WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON.
2) USE CONTAINER DEEP ENOUGH TO CONTAIN AND MINIMIZE PRODUCT
SPLASHING.
3) PLACE CONTAINER ON STABLE, FLAT SURFACE, AS CLOSE TO KETTLE AS
POSSIBLE.
4) STAND TO LEFT OR RIGHT SIDE OF KETTLE (DEPENDING ON TILTING
HANDLE PLACEMENT) WHILE POURING . DO NOT STAND DIRECTLY IN POUR
PATH OF HOT CONTENTS.
5) POUR SLOWLY, MAINTAIN CONTROL OF KETTLE BODY HANDLE AT ALL
TIMES, AND RETURN KETTLE BODY TO UPRIGHT POSITION AFTER
CONTAINER IS FILLED OR TRANSFER IS COMPLETE.
6) DO NOT OVER FILL CONTAINER. AVOID DIRECT SKIN CONTACT WITH HOT
CONTAINER AND ITS CONTENTS.
WARNING:FAILURE TO CHECK SAFETY VALVE OPERATION PERIODICALLY COULD RESULT
IN PERSONAL INJURY AND/OR DAMAGE TO EQUIPMENT.
WARNING:WHEN TESTING, AVOID ANY EXPOSURE TO THE STEAM BLOWING OUT OF THE
SAFETY VALVE. DIRECT CONTACT COULD RESULT IN SEVERE BURNS.
WARNING:TO AVOID INJURY, READ AND FOLLOW ALL PRECAUTIONS STATED ON THE
LABEL OF THE WATER TREATMENT COMPOUND.
WARNING:BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC
POWER SUPPLY.
2
OM/SM-TDB/7
IMPORTANT — READ FIRST — IMPORTANT
WARNING:KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND ELECTRICAL
EQUIPMENT. NEVER SPRAY OR HOSE THE SUPPORT HOUSING OR ELECTRICAL
CONNECTIONS.
CAUTION:MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES
AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN. WEAR RUBBER GLOVES,
GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ
THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE
CLEANER TO BE USED.
The Groen TDB/7 is a table top, tilting, steam
jacketed kettle with a thermostatically controlled,
self-contained, electrically-heated steam supply
and appropriate controls, mounted on a sturdy
base. The Model TDB/7 is available in 20 or 40 quart capacity.
The body of the TDB/7 Kettle is constructed of
stainless steel, welded into one solid piece. The
kettle is furnished with a reinforced rim and a
butterfly shaped pouring lip. It has a steam
jacket rated for working pressures up to 50 PSI.
Kettle finish is 180 emery grit on the inside and
bright semi-deluxe on the outside. A tilt handle
allows the operator to manually tilt the kettle
body in a controlled manner. Pouring height
accepts pans up to 4 inches high on a table top.
A built-in steam generator, sized for the kettle
capacity and heated by electricity, delivers steam
into the jacket. “Airless” operation of the steam
jacket permits uniform, efficient heating at
temperatures as low as 150°F and as high as
295°F. In addition to the adjustable thermostat
for operating control, the unit has a tilt cut-off
switch, low water cut-off, safety valve, and highlimit pressure switch as safety features. A
heating indicator light, pressure gauge, and sight
glass are provided for monitoring kettle
operation.
A single electrical connection is required for
installation. The unit may be ordered for use with
208/240 or 480 volt power. All kettles are wired
for three-phase operation. For single-phase
conversion, see the wiring diagrams in this
manual.
1. Stand that supports the unit and holds a pan in position for filling
2. Lift-off cover
3. Basket insert
4. Fill faucet
5. Manual stirrers
6. Motor driven agitator
6
Inspection & Unpacking
OM/SM-TDB/7
The unit will arrive in a heavy shipping carton
and will be attached to a skid. Immediately upon
receipt, inspect the carton carefully for exterior
damage.
CAUTION
SHIPPING STRAPS ARE UNDER TENSION
AND CAN SNAP BACK WHEN CUT. TAKE
CARE TO AVOID PERSONAL INJURY OR
DAMAGE TO THE UNIT BY STAPLES LEFT
IN THE WALLS OF THE CARTON.
Carefully cut the polyester straps around the
carton and detach the sides of the box from the
skid. Pull the carton up off the unit.
Thoroughly inspect the unit for concealed
damage. Report any shipping damage or
incorrect shipments to the delivery agent.
Write down the model number, serial number,
and installation date, and retain this information
for future reference. Space for these entries is
provided at the top of the Service Log at the
back of this manual. Keep this manual on file
and available for operators to use.
CAUTION
THIS UNIT WEIGHS 140 TO 163 LB. (64 TO
74 KG). INSTALLER SHOULD OBTAIN
HELP AS NEEDED TO LIFT THIS WEIGHT
SAFELY.
When installation is to begin, carefully cut the
straps which hold the unit on the skid. Lift the
unit straight up off the skid. Examine packing
materials to be sure loose parts are not
discarded with the materials.
Attach the tilt handle (normally shipped inside
the kettle) by carefully threading it into the socket
on the trunnion support. Be careful to avoid
cross-threading fine socket threads.
The TDB/7 is shipped from the factory strapped on a
pallet. The tilt handle is inside the kettle.
7
OM/SM-TDB/7
Installation
The Groen Kettle is provided with
complete internal wiring. It is
ready for immediate connection. A
wiring diagram is provided in this
manual and on the inside of the
control housing service panel. Any
mechanical or electrical changes must be
approved in by Groen’s Food Service
Engineering Department.
WARNING
INSTALLATION OF THE KETTLE MUST BE
DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY. IMPROPER
INSTALLATION CAN RESULT IN INJURY
TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT.
The completed unit has been operated at the
factory to test all controls and heater elements.
1. Set the kettle in place and level it. The
base should be securely fastened to a
table or work surface. Four 3/8”-16 N.C.
threaded couplings are provided in the
base of unit. Installation under a ventilation
hood is recommended.
2. Provide electrical power as specified on
the electrical information plate attached to
the equipment. Observe local codes
and/or The National Electrical Code in
accordance with ANSI/NFPA 70 - (current
edition).
3. The equipment is shipped ready for
three phase operation. Refer to the
wiring diagram for single phase
operation.
4. Bringing the electrical service through
the entrance at the rear of the support
housing, making a watertight connection
with the incoming lines. (A BX
connection is not recommended.)
DANGER
ELECTRICALLY GROUND THE UNIT AT
THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN
ELECTROCUTION AND DEATH.
5. Confirm that the jacket water level is
above mid point of sight glass. If the
level is low, follow the instructions under
“Jacket Filling and Water Treatment” in
the “Maintenance” section of the
manual.
6. The open end of the elbow on the outlet
of the safety valve must be directed
downward on old models. If it is not, turn
the elbow to the correct position. On new
models the safety valve points down.
7. Any mechanical or electrical change
must be approved by the Groen Food
Service Engineering Department.
TDB/7 ELECTRICAL SPECIFICATIONS
VOLTAGE PHASEKWAMPSKWAMPS
20816.33110.852
20836.31810.830
24018.43514.460
24038.42014.435
48016.31312.025
48036.3812.015
40037.811.213.219
20 QUARTS 40 QUARTS
TDB/7 SUPPLY WIRE REQUIREMENTS
Copper only, THHN (90°C)
20 QUARTS 40 QUARTS
VOLTAGEPHASEAWGmmAWGmm
2081
3
2401
3
4801
3
4003—1.8—
8
12——
8
3.0
10
—
1414——10
8
12
6
—
8
—
4
3.5
8
—
2.5
OM/SM-TDB/7
Initial Start-Up
IMPORTANT:
BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING
INSTRUCTIONS, CAUTIONS, AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL.
Now that the kettle has been installed, you
should test it to ensure that the unit is operating
correctly.
1. Remove all literature and packing
materials from inside and outside of the
unit.
2. Turn on the electrical service to the unit.
3. Pour 1-2 quarts of water into the kettle.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT
COULD RESULT IN SEVERE BURNS.
4. Following “To Start Kettle” instructions in
the “Operation” section of this manual,
begin heating the water at the highest
thermostat setting. The heating indicator
light should come on immediately, and
heating should continue until the water
boils.
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE.
DIRECT CONTACT COULD RESULT IN
SEVERE BURNS.
5. To shut down the unit, turn the thermostat
dial to “OFF”.
If the unit functions as described above, it is
ready for use. If the unit does not function as
intended, contact your local Groen Certified
Service Agency.
A simple turn of the thermostat controls the Groen TBD/7 Kettle