Giles OVH-10-C User Manual

Operations & Service Manual
OVH-10-C
Giles Enterprises, Inc.
An ISO 9001-2008 Registered Company • Committed to Quality
2750 Gunter Park Drive West • Montgomery, AL 36109 USA Phone: 334.272.1457 • Fax: 334.239.4117 • Website: www.gfse.com
Toll Free: 800.554.4537 (
USA & Canada Only)
LIMITED WARRANTY
Subject to the terms and conditions of this Limited Warranty as herein stated, all Giles Enterprises, Inc., Foodservice Equipment and parts purchased new from an authorized Giles Enterprises, Inc., representative are warranted as to defects in material or workmanship for a period of 24 months from the date of installation, provided, however, that with regard to labor costs in connection with this warranty, see below. All installations must be made by a qualified installing agency in accor­dance with all applicable codes and/or regulations in the jurisdiction in which installed. Limited war­ranty coverage is extended to the original owner only and is void if the unit is resold.
During the Limited Warranty period, Giles Enterprises, Inc. will replace or recondition, at its factory, any part or parts of this unit which Giles Enterprises, Inc. inspectors judge defective, provided the unit has been subjected to normal usage, properly installed, operated and serviced. This Limited Warranty does not cover cosmetic damage, and damage due to acts of God, accident, misuse, alter­ation, negligence, abuse of the Giles Foodservice Equipment or the use of unorthodox repair meth­ods. All parts replaced under this Limited Warranty carry only the unexpired term of this Limited Warranty. Limited Warranty service may be furnished only by an authorized Giles Enterprises, Inc., representative.
If Limited Warranty service is requested, Giles Enterprises, Inc., will send factory-authorized serv­ice representatives to repair, recondition, replace or inspect units of its manufacture with such labor being rendered without cost to owner for 24 months from the date of installation. Otherwise, serv­ice, including labor and transportation charges or other expenses, in connection with the removal or installation of any part or parts supplied under this Limited Warranty, are specified on the original sales contract between the purchaser and the authorized Giles Enterprises, Inc., representative.
Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured.
Giles Enterprises, Inc. makes no further warranties, express or implied including implied warranties of merchantability or fitness for a particular purpose, and has no other obligation or liability not specifically stated herein.
Repair or replacement as provided under this limited warranty is the exclusive remedy. Giles Enterprises, Inc., shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, except to the extent prohibited by applicable law. Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this limited warranty.
Used Giles Enterprises, Inc., Foodservice Equipment or parts or Giles Enterprises, Inc., Foodservice Equipment or parts not purchased from an authorized Giles Enterprises, Inc., representative, carry no warranties, express or implied.
Model: OVH-10-CTable Of Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Safety Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Specific Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-01. Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-02. Standard Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-03. Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-04. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1-04.1. Overall Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1-04.2. Regulatory Listings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1-04.3. Hood Weights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2-01. Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2-02. Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2-02.1. Clearance to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2-03. Cooking Appliance Limitations & Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2-04. Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2-04.1. Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2-04.2 Hood & Appliance Wiring Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2-04.2.1. Connection w/Hood & Appliance on same Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2-04.2.2. Connection w/ 380-480V Appliance Power Separate from 208-240V Hood Power . . . . . . . 11
2-04.2.3. Connection w/120V to 480V Appliance Power Separate from 208-240V Hood Power
using Remote Shunt Trip Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2-05. Air Baffle Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2-06. Final Countertop Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3-01. Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3-02. Hood Front & Filter Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3-03. Accessories (Standard) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3-04. Accessories (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
iii
Model: OVH-10-C Table Of Contents
4. Operation & Filter Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4-01. Hood Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4-01.1. Starting the Hood (Regular) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4-01.2 Starting the Hood (ILS Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4-02. Hood Filter System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4-02.1. Ventless Hood Filter Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4-02.2. Filter Removal, Baffle, EAC, Charcoal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4-02.3. Filter Installation, Baffle, EAC, Charcoal Filter Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4-02.4. Charcoal or Baffle Filter Missing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4-02.5. EAC Filter Missing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4-02.6. EAC Filter Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4-03. Filter Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4-03.1. Baffle Filter Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4-03.2. EAC Filter Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4-03.3. Charcoal Filter Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4-04. Filter Alarm Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5. Hood Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.01. Monthly Interlock Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5-02. Hood Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5-02.1. Weekly Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5-02.2. Quarterly Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5-03. Maintenance and Service Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6-01. Troubleshooting Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7. Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7-01. Parts Ordering and Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7-02. Rear Electrical Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7-03. Hood Front, Filter & Fan Compartment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
iv
Model: OVH-10-CSafety
Safety
Safety Overview
The instructions contained in this manual have been prepared to aid you in learning the proper procedures for installing and servicing the OVH-10-C Counter-Top Hood.
Throughout this manual, safety precautions are identified through the use of safety alert symbols and three key words: DANGER, WARNING and CAUTION. All safety alert information will precede the step(s) to which it applies. Suggested, recommended, or otherwise noteworthy information is identified through the use of NOTES. Additionally, certain words are used to indicate a specific meaning or to add emphasis.
The following words are used as indicated throughout the manual:
Shall: understood to be mandatory. Should: understood to be advisory. May: understood to be permissive. Will: indicates a future event or condition is highly likely to occur.
!!
or
(Safety Alert Symbol) Used in conjunction with key words DANGER, WARNING, or CAUTION to alert you of potential personal injury hazards and to highlight precautionary measures that pertain to subsequent step(s). Adhere to all safety messages following these symbols to avoid possible injury or death. Failure to comply with safety precautions identified by a safety alert symbol may also void the equipment’s warranty.
DANGER
!
Indicates an imminently hazardous situation which, if not avoided, will result in serious injury, or even
death. Use of this is limited to the most extreme situations.
WARNING
!
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury, or even
death.
CAUTION
!
Indicates a potentially hazardous situation which, if not avoided, may result in minor to moderate injury.
Also alerts against unsafe practices.
CAUTION
When used without the safety alert symbol, CAUTION indicates a potentially hazardous situation
which, if not avoided, may result in damage to the equipment or property, and void the warranty.
NOTE:
Identifies suggested, recommended, or otherwise noteworthy information.
v
Model: OVH-10-C Safety
Specific Safety Precautions
For your safety, please observe the following precautions when operating or servicing the OVH-10-C Ventless Hood. Read the following important safety information to avoid personal injury and/or damage to the equipment or property.
DANGER
!
Always disconnect the source of main power before removing any service panel or cover.
Failure to ensure that the Power Switch is in the OFF position during servicing or when replacing filters
could result in damage to the equipment, electrical shock or other serious personal injury.
Failure to comply with these DANGER notices will result in serious injury or even death, equipment or
property damage, and void the warranty.
WARNING
!
DO NOT use or store flammable liquids or materials that produce flammable vapors in the vicinity of
this or any other appliance!
Consult a qualified electrician to ensure that all electrical requirements are met and that the unit is prop-
erly grounded.
Before installing or servicing this equipment, read the contents of this manual thoroughly.
Improper installation, adjustments or alterations, or improper service/maintenance could result in seri-
ous injury or even death, damage to equipment or property, and void the warranty.
Failure to comply with these WARNING notices could result in serious injury or even death, and equip-
ment or property damage.
WARNING
!
UV MODEL ONLY
An internal ultraviolet radiation source is present on these models during operation.
Keep protective covers and panels in place during normal operation. Replace any removed after servic-
ing.
An interlock circuit in the hood reduces potential for exposure to excessive ultraviolet radiation. DO
NOT attempt to disconnect or bypass this interlock.
Looking directly at a UV light source without proper eye protection can cause serious eye injury.
vi
Model: OVH-10-CSafety
CAUTION
!
Maintain a minimum clearance of 18” (457.2mm) between the hood’s exhaust outlet and the ceiling, or
other overhead obstruction.
Exercise care when lifting or moving the unit. See Section 1-4.4, Hood Weights.
Exercise care when removing the unit from the shipping skid.
CAUTION
!
DO NOT operate the unit unless you fully understand its components and their intended function.
DO NOT bend the collection fins or break the ionizer wires of the Electrostatic Air Cleaner (EAC).
Doing so will prevent it from working properly and cause a shutdown of power to the appliance being operated under the hood.
Failure to comply with these CAUTION notices may result in minor to moderate injury, damage to equipment or property, and void the warranty.
CAUTION
The electronic components of the Control Panel are somewhat impact-sensitive. Exercise care when
performing tasks near the unit’s Control Panel to prevent possible unintentional damage.
After cleaning the EAC, DO NOT attempt to dry the EAC cell by installing it in the hood and running the
fan to force air dry, or by running the appliance under the hood to heat dry. This could potentially dam­age the EAC power system, leading to failure and voiding the warranty. The EAC filter must air dry at ambient room temperature, preferably overnight.
When cleaning the Hood, Hood Skirt or Stand ...
•• DO NOT steam clean.
•• DO NOT spray with water from a hose.
•• DO NOT use products containing chlorine.
•• DO NOT use abrasive products, steel wool or scouring pads.
Failure to comply with these CAUTION notices may result in damage to equipment or property, and
void the warranty.
vii
Model: OVH-10-C Safety
NOTE:
Giles’ responsibility for the damage to the unit ends once the freight shipment is loaded onto the carri-
er’s truck. Upon delivery, if the palletized unit showed any signs of damage, the entire load, including the supplied accessories, should have been inspected immediately and any damage to the equipment should have been promptly reported to the freight company.
As an aid for electricians and installers, an electrical wiring diagram is provided with the unit. Refer to
the wiring diagram during installation or while servicing.
Comply with all appropriate state and/or local heath regulations regarding cleaning and sanitation of
foodservice equipment.
Giles recommends the use of mild, bio-degradable, non-toxic degreasers, such as Clear Magic or
Simple Green, for cleaning parts of the hood where excessive grease film accumulation is present.
Always ensure the unit is installed and electrically grounded in accordance with local codes, or in the
absence of local codes, in accordance with the National Electrical Code ANSI/NFPA No. 70-1984.
NOTE:
The approximate sound level of the hood while operating is 65 dB.
NOTE:
For some installations, it may be necessary to consult a HVAC specialist to con-
firm that proper room air exchange is occurring and that the on-site A/C system is capable of handling the anticipated heat load.
Exhaust ventilation is recommended for areas in which recirculating hoods are operated. Giles recom-
mends 50 CFM per linear foot of hood space. This amount could vary based on local codes and
site-specific situations.
viii
Introduction
Model: OVH-10-C
1. Introduction
Thank You! for purchasing the OVH-10-C Ventless Hood System manufactured by Giles Enterprises, Inc., Montgomery, Alabama, USA. The OVH-10-C is a Limited Type-1 Hood designed specifically for use on counter-top spaces and is listed for use with a variety of small commercial appliances ... Toasters, Conveyor Ovens, Ovens and Rotisseries.
With proper care and maintenance, this unit will provide years of trouble-free service. To help protect your investment in this equipment, we recommend taking a few moments to familiarize yourself with the installation, operation, cleaning, and maintenance procedures described in this manual. We urge you to read this manual before installing or operating the hood. Adherence to these recommended procedures will minimize future potential for costly downtime and equipment repairs. Please retain this manual for later reference.
1-1. Construction
The OVH-10-C Hood is constructed of 16-Ga to 20-Ga Stainless Steel.
1-2. Standard Features
Control Panel
LED light cluster indicates the status and condition of the Electronic Air Cleaner (EAC) cell.
Appliance Powered light indicates that power is being supplied to the interlocked appliance(s)
operating under the hood.
Filter Missing light indicates that the Baffle Filter and/or the Charcoal Filter is missing or not properly
installed.
Filter Clogged light indicates that the Baffle Filter and/or the Charcoal Filter is possibly clogged and
requires attention.
Filters
• Baffle Filter - captures and collects large particulate entrained in the air stream.
• Electronic Air Cleaner (EAC) - captures and collects fine particulate air contaminates.
• Charcoal Filter - activated carbon filter helps to eliminate cooking odors.
1-3. Optional Features
Inter-Locked Start (ILS)
• This system prevents the hood and the served appliance(s) from restarting after a power interruption
without being attended by an operator. This optional provision is required by code in certain cities and/or states.
1
Model: OVH-10-C Introduction
27 1/8
688.24
INSIDE
28 1/16
712.41 26 11/16
677.49
45 5/16
1151.59
29 15/16
760.4
27 5/16
693.9
1 1/16
26.62
9 1/2
241.8
5 13/16
147.57
4 3/8
111.25
7 3/8
187.38
POWER CONNECTION
20 5/16
516.69
1-4. Specifications
1-4.1. Overall Dimensions
2
1-4.2.Regulatory Listings
1-4.3.Hood Weight
Hood Crated Weight Uncrated Weight
Model: OVH-10-CIntroduction
OVH-10-C 245 lbs [111 kg] 175 lbs [79 kg]
3
Model: OVH-10-C Installation
2. Installation
This section summarizes the procedures necessary to install your new OVH-10-C Countertop Hood. Before installing and attempting to operate, please read the contents of this manual thoroughly. Following these procedures will help ensure safe and proper installation.
2-01. Unpacking
!! IMPORTANT NOTE:
If the palletized unit showed any signs of damage, you should have immediately inspected the
equipment and any other packed accessories, and promptly notified the freight company of any and all
damages. Typically, it is the customer’s responsibility to claim freight damage.
The unit is shipped on a wooden skid with protective framing, secured to the skid by high-tensile plastic strapping and wrapped with machine applied stretch-wrap. Perform the following steps to unpack the unit:
1. Position the palletized unit in an area with sufficient space for unpacking.
2. Cut and remove stretch-wrap and all strapping.
3. Use appropriate tools to remove the wooden crate from around the unit.
3. Remove any packed accessories and/or parts from the skid and set aside.
4. The unit is extremely heavy. Using suitable lifting equipment or adequate manpower, lift the unit and
remove it from the shipping skid. See Section 1-4.3, Hood Weights.
5. Properly dispose of all shipping materials.
CAUTION
!
The unit is extremely heavy and somewhat top-heavy! Exercise due caution when handling to avoid
personal injury or damage to the equipment. Take precautions not to damage the hood’s Base or Skirting.
Exercise care when removing the wooden framing from around the unit to avoid any exposed nails or staples.
Failure to comply with these CAUTION notices may result in minor to moderate injury, damage to
equipment or property, and void the warranty.
4
Model: OVH-10-C
Model: OVH-10-C
2-02. Location
CAUTION
!
DO NOT MODIFY OR ALTERTHIS EQUIPMENT, OR ADD ATTACHMENTS OF ANY KIND.
NOTE:
For some installations, it may be necessary to consult a HVAC specialist to
confirm that proper room air exchange is occurring and that the on-site A/C system is capable of handling the anticipated heat load.
Exhaust ventilation is recommended for areas in which recirculating hoods are operated. Giles
recommends 50 CFM per linear foot of hood space. This amount could vary based on local codes
and site-specific situations.
NOTE:
The sound level of the hood while operating will be approximately 65 dB.
1. Do not obstruct the exhaust air outlet. Maintain a minimum clearance of 18 inches (457.2 mm)
between the air outlet and the ceiling, or any other overhead obstruction.
2. The OVH-10-C Hood model is designed to sit atop a counter space. Ensure that the intended site is structurally sound and capable of supporting the hood’s weight plus that of the appliance(s) to be placed under it. See Section 1-4.3, Hood Weight.
5
Model: OVH-10-C Installation
27 1/8
688.24
INSIDE
28 1/16
712.41 26 11/16
677.49
45 5/16
1151.59
29 15/16
760.4
27 5/16
693.9
1 1/16
26.62 20 5/16
516.69
0" CLEARANCE TO COMBUSTIBLES
0" CLEARANCE TO COMBUSTIBLES
18" CLEARANCE TO COMBUSTIBLES
18
457.2
MIN.
EXHAUST CLEARANCE
0" CLEARANCE TO COMBUSTIBLES
0" CLEARANCE TO COMBUSTIBLES
2-02.1 Clearance to Combustibles
6
HEATING
AREA
HEATING
AREA
27 1/8
688.24
INSIDE
28 1/16
712.41
26 11/16
677.49
45 5/16
1151.59
29 15/16
760.4
27 5/16
693.9
1 1/16
26.62
20 5/16
516.69
18
457.2
MIN.
EXHAUST CLEARANCE
A
MAX.
4
101.6
MIN.
4
101.6
MIN.
4
101.6
MIN.
APPLIANCE RESTRICTIONS
APPLIANCE TYPE
MAX. ELECTRIC
INPUT, kW (WATTS)
A
CONVEYOR OVENS 11.5 (11,500) 19* [482.6] OVENS 6.2 (6200) 6 [152.4] ROTISSERIE 6.2 (6200) 6 [152.4] CONVEYOR TOASTERS (VERTICAL AND
HORIZONTAL)
11.5 (11,500) 19* [482.6]
FLAT TOASTERS 11.5 (11,500) 1 9 [482.6]
* - M EASURED TO TOP OF CONVEYOR BELT
2-03. Cooking Appliance Limitations & Clearances
Hood is listed for Electric Appliances ONLY.
Model: OVH-10-CInstallation
* Appliance(s) exceeding 50 Amps must have a separate circuit from the Hood, but be intelocked
through the Hood contactor coil.
7