ISO 9001 Registered Company • Committed to Quality
2750 Gunter Park Drive West • Montgomery, AL 36109 USA
Phone: 334.272.1457 • Fax: 334.239.4117 • Website: www.gfsequipment.com
Service Hotline (Toll Free): 800.554.4537 (USA & Canada Only)
•Subject to the terms and conditions of this Limited Warranty as herein stated, all Giles Enterprises,
Inc., Foodservice Equipment and parts purchased new from an authorized Giles Enterprises, Inc.,
representative are warranted as to defects in material or workmanship for a period of 12 months
from the date of installation, provided, however, that with regard to labor costs in connection with
this warranty, see below. All installations must be made by a qualified installing agency in accordance with all applicable codes and/or regulations in the jurisdiction in which installed. Limited warranty coverage is extended to the original owner only and is void if the unit is resold.
•During the Limited Warranty period, Giles Enterprises, Inc. will replace or recondition, at its factory,
any part or parts of this unit which Giles Enterprises, Inc. inspectors judge defective, provided the
unit has been subjected to normal usage, properly installed, operated and serviced. This Limited
Warranty does not cover cosmetic damage, and damage due to acts of God, accident, misuse, alteration, negligence, abuse of the Giles Foodservice Equipment or the use of unorthodox repair methods. All parts replaced under this Limited Warranty carry only the unexpired term of this Limited
Warranty. Limited Warranty service may be furnished only by an authorized Giles Enterprises, Inc.,
representative.
•If Limited Warranty service is requested, Giles Enterprises, Inc., will send factory-authorized service representatives to repair, recondition, replace or inspect units of its manufacture with such labor
being rendered without cost to owner for ninety (90) days from the date of installation. Otherwise,
service, including labor and transportation charges or other expenses, in connection with the
removal or installation of any part or parts supplied under this Limited Warranty, are specified on the
original sales contract between the purchaser and the authorized Giles Enterprises, Inc., representative.
•Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way
without obligation to alter such equipment or parts previously manufactured.
•Giles Enterprises, Inc. makes no further warranties, express or implied including implied warranties
of merchantability or fitness for a particular purpose, and has no other obligation or liability not
specifically stated herein.
•Repair or replacement as provided under this limited warranty is the exclusive remedy.Giles
Enterprises, Inc., shall not be liable for any incidental or consequential damages for breach of any
express or implied warranty on this product, except to the extent prohibited by applicable law. Any
implied warranty of merchantability or fitness for a particular purpose on this product is limited in
duration to the duration of this limited warranty.
•Used Giles Enterprises, Inc., Foodservice Equipment or parts or Giles Enterprises, Inc., Foodservice
Equipment or parts not purchased from an authorized Giles Enterprises, Inc., representative, carry
no warranties, express or implied.
The instructions contained in this manual have been prepared to aid you in learning the proper procedures
for installing and servicing your unit.
Throughout this manual, safety precautions are identified through the use of the safety alert symbol and
three signal words: DANGER, WARNING, and CAUTION. All safety alert information precedes the
step(s) to which they apply. Suggested, recommended, or other noteworthy information is identified
through the use of NOTES. Additionally, certain words are used to indicate a specific meaning or to add
emphasis.
The following words are used as indicated throughout the manual:
Shall: understood to be mandatory.
Should: understood to be advisory.
May: understood to be permissive.
Will: indicates a future event/condition to occur.
!!
or
(Safety Alert Symbol)
Used in conjunction with signal words (DANGER, WARNING, or CAUTION) to alert you of potential personal injury hazards, immediately preceding precautionary measures that pertain to subsequent step(s).
Obey all safety messages that follow this symbol to avoid possible injury or death. Failure to adhere to
safety precautions identified by the safety alert symbol may also void the warranty.
DANGER
!
• Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Use of this is limited to the most extreme situations.
WARNING
!
• Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
!
• Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Also used to alert against unsafe practices.
CAUTION
• When used without the safety alert symbol, CAUTION indicates a potentially hazardous situation
which, if not avoided, may result in equipment/property damage, and void the warranty.
NOTE:
•Identifies suggested, recommended, or other noteworthy information.
v
Model: EH-5 & EH-6Safety
Specific Safety Precautions
For your safety, please observe the following precautions when operating or servicing your Environmental
Hood, Model EH-5 or EH-6. Read the following important safety information to avoid personal injury
and/or damage to the equipment.
DANGER
!
• Always disconnect the source of the main power before removing the service entrance box cover.
• Failure to ensure the Power switch is in the “OFF” position during servicing and when replacing filters
could result in equipment damage, electrical shock and/or personal injury.
• Failure to comply with these DANGER notices will result in death or serious injury, equipment/property
damage, and void the warranty.
WARNING
!
• DO NOT use or store flammable liquids or items that produce flammable vapors, in the vicinity of this
or any other appliance!
• Consult a qualified electrician to ensure all electrical specifications have been met and the unit is prop-
erly grounded.
• Before installing or servicing this equipment, read the contents of this manual thoroughly.
• Improper installation, adjustment, alteration, service or maintenance could result in death or serious
injury, equipment or property damage, and void the warranty.
• Failure to comply with these WARNING notices could result in death or serious injury and equipment
or property damage.
WARNING
!
Internal ultraviolet radiation source present.
•
for UV Models
• Keep protective barrier in place.
• Replace all removable parts after servicing.
• An interlock is in place to reduce the potential of exposure to excessive ultraviolet radiation. DO NOT
attempt to defeat or by-pass this interlock system.
vi
Model: EH-5 & EH-6Safety
CAUTION
!
• Exercise care when lifting or moving the unit. See Section 1-4.4 for Hood weights.
• Exercise care when removing the wooden crate from around the unit.
CAUTION
!
• DO NOT operate the unit unless you fully understand the components and their intended function.
• Be careful not to bend the fins or break the ionizer wires on the EAC (Electrostatic Air Cleaner), as this
will prevent it from working properly and will possibly shut down power to the appliance being used
with the hood.
•
Failure to comply with these CAUTION notices may result in minor or moderate injury, equipment or property damage, and void the warranty.
CAUTION
• The electronic components of the Control Panel are impact-sensitive. Exercise care around the Control
Panel to maintain proper operation.
• Do not try to dry the EAC either by running the hood to air dry or by operating an appliance below to
heat dry. This could potentially damage the EAC causing improper operation and voiding the warranty.
• When cleaning:
•• DO NOT steam clean.
•• DO NOT use products containing chlorine.
•• DO NOT use abrasive products, steel wool or scouring pads.
• Failure to comply with these CAUTION notices may result in equipment or property damage and void
the warranty.
vii
Model: EH-5 & EH-6Safety
NOTE:
• Upon arrival, if the palletized unit shows any signs of damaged, immediately inspect the Hood and all
other components contained on the pallet, and notify the freight company of any damage to the unit.
• To aid electricians and technicians, an electrical wiring diagram is contained in this manual. Refer to the
wiring diagram during installation or servicing.
• Comply with all appropriate state and/or local heath regulations regarding the cleaning and sanitation of
equipment.
• For difficult areas with excessive particulate build up, a mild bio-degradable non-toxic degreaser (such as
Clear Magic or Simple Green) may be used.
• Always ensure the unit is electrically grounded and installed in accordance with local codes, or in the
absence of local codes, in accordance with the National Electrical Code ANSI/NFPA No. 70-1984.
viii
Model: EH-5 & EH-6Introduction
1.Introduction
Congratulations on the purchase of your new Giles Environmental Hood System (EH-5 or EH-6) manufactured by Giles Enterprises, Inc., Montgomery, Alabama (USA), hereafter referred to as "Giles". Two different
models (EH-5 and EH-6) are available, both ceiling mounted. Proper care and maintenance of this unit will
ensure years of trouble-free service.
To help protect your investment in this equipment, we recommend taking a few moments to familiarize
yourself with the installation, cleaning and maintenance procedures contained in this manual. Read these
instructions before installation and use. Adherence to these recommended procedures minimizes the
potential for costly "down-time" and equipment repairs. Please retain this manual for future reference.
1-1.Construction
The Environmental Hood System exterior is constructed of stainless steel.
1-2.Standard Features
Control Panel
• Control panel LED indicators display the status of the Left and Right EAC filters.
• Missing Filter Light indicates if one (or more) Baffle Filter, Pre-Filter, and/or Charcoal Filter is missing or
improperly installed.
Filters
• Baffle Filters capture large grease particulate.
• Pre-Filters capture smaller grease particulate.
• Electronic Air Cleaners (EAC) capture smoke & other fine contaminates in the air stream.
• Charcoal Filters help eliminate cooking odors from the air stream.
1-3.Optional Features
Inter-Locking Start System (ILS)
• Inter-Locking Start System (ILS) - Should there be a power interruption to the the hood, this system will
not allow the Hood and the Appliance(s) below it to restart without the attendance of an operator. This
system is required by code in some cities and/or states. Please consult with your local code officials to
see if this option is required.
Ultra-Violet Light
• Ultra Violet lamp working in conjunction with Giles proven air filtration system further reduces exhaust
emissions and improves odor control, as well as keeping the unit’s fan, plenum and discharge duct free
from grease build up.
1
Model: EH-5 & EH-6Introduction
1-4.Specifications
1-4.1. Overall Dimensions for EH-5
2
1-4.2. Overall Dimensions for EH-6
Model: EH-5 & EH-6Introduction
3
Model: EH-5 & EH-6Introduction
1-4.3. Regulatory Listings
1-4.4. Hood Weights
HoodCrated WeightUncrated Weight
EH-5664 lbs [302 kg]464 lbs [211 kg]
EH-6733 lbs [333 kg]553 lbs [251 kg]
4
Model: EH-5 & EH-6Installation
2.Installation
This section provides a summary of procedures necessary to install your new EH-5 or EH-6 Environmental
Hood. Before installing or servicing this equipment, please read the contents of this manual thoroughly.
Following these procedures will help ensure a safe and proper installation.
NOTE:
The Giles Environmental Hood is a traditional style ventilation hood that must be connected by ductwork
to an appropriately sized exhaust fan that discharges to the outside atmosphere. It is recommended that
a qualified ventilation specialist be consulted prior to installation to assess the site to determine fan and
ductwork requirements, as well as address any local regulatory permit requirements. If desired, a “Fan
Quotation Form” is available from Giles Services to help guide customers through this process. It is the
responsibility of the customer/end-user to supply the appropriate exhaust fan, ductwork, installation, all
permits, and any consulting services deemed necessary.
2-01. Unpacking
Your Environmental Hood should arrive palletized with a wooden protective frame, wrapped in machine
applied stretch-wrap, and secured to by means of high-tensile plastic strapping. Perform the following
steps to unpack the unit:.
1. Position the palletized unit in an area that has sufficient space for unpacking.
!! IMPORTANT NOTE:
• If the palletized unit shows any signs of damage, immediately inspect the equipment and other packed
components, and notify the freight company of any and all damages.
2. Cut and remove stretch-wrap and all strapping.
3. Use a hammer and pry-bar to remove the wooden framing from around the unit
CAUTION
!
• Use suitable equipment to lift the hood and carefully move it away from the pallet ... see Section 1-4.4
for hood weights. Take precautions not to damage to the hood’s bottom skirting. If possible, it is
advisable to rig and lift the hood from the topside, utilizing the hood’s hanging brackets.
•
Exercise care when removing the wooden framing from around the unit.
• Failure to comply with these CAUTION notices may result in minor or moderate injury, equipment or
property damage, and void the warranty.
5
Model: EH-5 & EH-6Installation
2-02. Location
CAUTION
!
• DO NOT MODIFY, ALTER OR ADD ATTACHMENTS TOTHIS EQUIPMENT
1. Ensure intended mounting site is structurally sound and capable of supporting the hood’s weight.
See Section 1-4.4 for hood weights
2-03. Hood Mounting Detail
1/2” All thread
1/2” Nut
1/2” Lock washer
1/2” Flat washer
1/2” Flat washer
1/2” Lock washer
1/2” Nut
1. Ensure the hood is level, left to right and front to back.
Exhaust Air Outlet
2. Ensure all mounting fasteners are secure.
6
Model: EH-5 & EH-6Installation
2-03. Hood Skirt Installation
NOTE:
• All hood Skirts MUST be installed to ensure proper and effective capture of vapors.
1. Apply a bead of Hi-Temp Silicone (tube enclosed) to the top flanges of both Side Skirts.
2. Attach Left and Right Side Skirts to hood with enclosed fasteners (do not tighten completely).
3. Apply a bead of the Hi-Temp Silicone to the top flange of the Rear Skirt.
4. Attach Rear Skirt to hood with enclosed fasteners (do not tighten completely) .
5. Fasten Left and Right Skirts to Rear Skirt.
6. Completely tighten all fasteners and wipe any excess silicone from the assembled Skirt.
NOTE: Peel all protective film from parts before assembling.
(21) 1/4-20 Nut
Bead of enclosed
Hi-Temp Silicone
Bead of enclosed
Hi-Temp Silicone
(21) 1/4-20 X 3/8 Screw
Left Skirt
Rear Skirt
Right Skirt
7
Model: EH-5 & EH-6Installation
2-04. Cooking Appliance limitations and clearances
HoodMax. Temp.
EH-5400775/1107@1.25 wc6 In.12 In.
EH-6400846/1208@1.25 wc6 In.12 In.
2-04.1.Griddle Limitations
HoodMax. Temp.Max. KW InputMax. Cooking Surface
EH-54002548 x 26
EH-64002560 x 26
2-04.2.Griddle Clearances
Recommended
Exhaust Airflow CFM
Side OverhangFront Overhang
Inches [Millimeters]
8
12” min.[304.8]
2-04.3.Range limitations
HoodMax. Temp.Max. kW InputMax Burners
EH-5400258
EH-6400258
2-04.4.Range clearances
Model: EH-5 & EH-6Installation
Inches [Millimeters]
12” min.[304.8]
33” min.[304.8]
42” max [1066.8]
9
Model: EH-5 & EH-6Installation
2-04.5.Oven limitations
HoodMax. Temp.
EH-550055
EH-650055
2-04.6.Oven clearances
Max. kW Input
(Total all Ovens)
Inches [Millimeters]
10
EH-6
EH-5
33” min.[304.8]
42” max [1066.8]
Loading...
+ 46 hidden pages