GE NETWORX NX-108E, NETWORX NX-116E, NETWORX NX-124E, NX-6, NX-8 User Manual

...
NETWORX
TM
NX-4
User manual
NX-4 SYSTEM
KEYPAD
Includes models
NX-108E, NX-116E, NX-
124E
POWER Light is “on” when AC
power is present; flashes to
indicate a low battery condition.
READY Light is “on” when the
system is ready to arm; flashes
if ready to “force arm”.
SERVICE
Light is “on” to indicate a
trouble condition with your system.
ARMED Light is “on” when
armed; “off” when disarmed;
flashes to indicate a previous
alarm.
INSTANT Light is “on” when
there is no entry/exit delay.
FIRE Light is “on” to indicate fire
alarm; flashes to indicate a
trouble condition with your fire
system.
ZONE LIGHTS
are “on” steady to
indicate bypass; slow flash for
zone fault; rapid flash for service
condition.
PULL OUT ZONE ID TAB
NOTE: Some of the features described above may or may not be available for your system.
Check with your installation company to find out how your system is programmed.
5 FUNCTION KEYS perform
various functions.
EMERGENCY ACTIVIATION KEYS
NUMERIC CODE
ENTRY KEYS
1
SECURITY SYSTEM NOTES
Installing/Service Company _________________________________ For Service Call __________________________________________ Central Station ___________________________________________
Duress Code ____________________
FUNCTION CODES
Function Code Controls Function
EMERGENCY ACTIVATION KEYS (check if enabled)
Fire Auxiliary Emergency Police
PROGRAMMED FUNCTIONS
 Abort Delay (s)  Cancel Alarm  Group Bypass (s)  Auto Bypass (s)  Chime  Quick Arm (s)  Auto Instant  Communicator Test  Re Exit  Battery Test  Forced Arming (s)  Siren Test
(s) These features should not be enabled on UL listed systems.
ENTRY / EXIT DELAY TIMES
Exit Delay Time __________ Secondary Exit Delay Time ________ Entry Delay Time _________ Secondary Entry Delay Time _______
ZONE DESCRIPTIONS
01 _______________________ 05 ________________________ 02 _______________________ 06 ________________________ 03 _______________________ 07 ________________________ 04 ________________________ 08 ________________________
Installer: Mark wireless zones with an “u” as required by UL.
2
THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION. ALL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET. FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT WORKING PROPERLY. THIS BOOKLET SHOULD BE KEPT IN AN ACCESSIBLE LOCATION FOR THE LIFE OF THE SECURITY SYSTEM. IF YOU DO NOT UNDERSTAND ANY PART OF THIS MANUAL YOU SHOULD NOTIFY YOUR INSTALLING COMPANY.
The SECURITY CONTROL can be turned on (ARMED) and off (DISARMED) by entering a 4 or 6 digit code into the Keypad Control, which is similar to a telephone keypad. If your Security Control has been so programmed, you may be able to turn on (ARM) your System by simply pressing the [STAY] or [EXIT] key. The system must always be disarmed using a 4 or 6 digit code. The LED keypad includes up to 35 lights and a built-in electronic sounder. These provide specific information relating to the status of the security system which is described in the booklet. Understanding what the lights and sounds mean will help you to easily operate your system.
READ THE ENTIRE MANUAL AND, IF POSSIBLE, PRACTICE ON THE KEYPAD CONTROL WHILE YOUR PROFESSIONAL INSTALLER IS ON SITE.
KEEP IN MIND, THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS:
1. The quantity, quality, and placement of security devices attached to this system.
2. The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system.
YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY/SECURITY PLAN FOR YOUR HOME/BUSINESS.
Your security system is an electronic device and is subject to failure or
malfunction. Do not rely on it as your single source of security.
Your system should be tested weekly. Your system will not work without power. Warning devices will need to be loud enough, wired correctly, and properly
placed to provide notification of an alarm event.
Smoke and heat detectors may not detect heat and smoke in all situations. Use qualified security professionals to install and maintain your security system. It may be possible to arm the security system without the backup battery
connected. Your periodic test should be done with A.C. Power removed to verify the battery is connected and adequately charged.
Care should be taken to plug in and restrain the A.C. Transformer after testing.
PLEASE READ THE FOLLOWING INFORMATION AND INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR SECURITY CONTROL SYSTEM. IF YOU DO NOT UNDERSTAND ANY PORTION OF THIS MANUAL, OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM, CONTACT THE INSTALLING COMPANY LISTED ON PAGE 1 OF THIS BOOKLET.
3
TABLE OF CONTENTS
GLOSSARY OF TERMS....................................................................4
UNDERSTANDING THE LIGHTS.....................................................5
Armed Light......................................................................................5
Bypass Light.....................................................................................5
Cancel Light .....................................................................................5
Chime Light......................................................................................5
Exit Light...........................................................................................5
Fire Light ..........................................................................................5
Instant Light......................................................................................5
Power Light ......................................................................................5
Ready Light......................................................................................5
Stay Light .........................................................................................6
Zone Light ........................................................................................6
EMERGENCY ACTIVATION KEYS.................................................6
KEYPAD FUNCTIONS.......................................................................7
Arming Your System In The “Away” Mode.......................................7
Arming Your System In The “Stay” Mode.........................................7
Using The Quick Arm ......................................................................8
Disarming Your System....................................................................8
Cancel / Abort Feature ....................................................................9
Bypassing Zones..............................................................................9
Group Bypass...................................................................................9
Unbypassing.....................................................................................9
Turning The Door Chime On And Off...............................................9
CHANGING USER CODES.............................................................10
ASSIGNING USER CODE AUTHORITY LEVELS ......................10
OTHER KEYPAD FUNCTIONS......................................................11
Setting The Keypad Tone...............................................................11
View Alarm Memory.......................................................................11
Test Function .................................................................................12
Walk Test .......................................................................................12
Reset Function...............................................................................12
Setting The System Date ...............................................................12
Setting The System Clock..............................................................13
KEYPAD CONTROL TONES (BEEPS).........................................14
SERVICE MENU................................................................................15
EMERGENCY EVACUATION PLANS...........................................16
4
GLOSSARY OF TERMS
Abort Delay: An option that allows a delay in reporting to the central station.
There is a communicator delay of 30 seconds. It can be removed, or increased up to 45 seconds at the option of the end user by consulting with the installer.
Authority Level: The level of access an individual has when using an alarm panel.
Central Station: Location where alarm data is sent during an alarm report. Chime Feature: An option that allows the keypad to sound a ding-dong
whenever an entry/exit door is opened. Codes: Can be either User Codes (relating to a person) or Function Codes (a
toggle switch to turn specific functions on/off). NOTE: A system may have either 8 four (4) digit codes or 8 six (6) digit codes, but not a mixture of the two.
Duress Code: An option that allows a special code to be sent to the central station that indicates the alarm system is being operated under duress. Any arming or disarming operation performed using the Duress PIN (in lieu of the User PIN) will operate normally, without additional audible or visual indicators.
Forced Arming: An option that allows the system to be turned on (ARMED) with one or more zones open. A system that is ready to be “force armed” will flash the ready light. (Note: Those zones that are not ready will not create an alarm.)
Function Code: A Function Code is either a four (4) or six (6) digit code that has been programmed by the installer to operate a device.
Group Bypass: An option that allows the user to bypass multiple zones with a single operation.
Instant/Delay: An option that allows an instant alarm condition for Entry/Exit doors, or grants a delay to allow someone to enter/exit the building without an alarm, or before entering a user code to disarm.
Master Code: A master arm/disarm code that can program other user codes. Perimeter: The outer edge of the protected area. Quick Arm: An option that allows you to turn on (ARM) the security system by
pressing either the [STAY] or [EXIT] key on the keypad control (for ARMING only) as programmed by the installing company.
User Code: A four (4) or six (6) digit entry used to arm or disarm the system.
Loading...
+ 14 hidden pages