On/Off Learn
Quick Start Guide
45129
The Control Center operates in three ways:
Armed/Alarm Mode | Notification Mode | Dedicated Alert Mode
AC Power Adapter
Control Center
Creating a new security code
Step 1 - On the Control Center press and hold the “Learn” button, then press and hold the “Arm” button together until a long beep sounds. Release buttons, the green power button will begin to flash.
Step 2 - Enter the current code (default is 1234) Step 3 - Enter new code
Step 4 - Re-enter new code to confirm
Arm
Armed Power
1 2 3 4
Zone
1 2 3 4
Zone
4 “AAA” Batteries
+
+
+
-
-
+
-
-
1 2 3 4
(Not Included)
Recommended for back-up situations
Zones 1,2, & 3 - Activating HOME or AWAY Mode
Step 2
Step 3
Step 4
1 2 3 4
Arm
Armed Power
Input DC 12V
-
Mute
Learn
Alert
Chime
Off
+
Step 1
Learn
Add a Sensor to any Zone
Step 1 - Press and hold the “Learn” button, for three seconds, the Control Center will sound a long beep. Release the button.
Step 2 - Select the Zone number, the Zone LED will begin to flash.
Step 1
Input DC 12V
Step 2
Arm
Armed Power
1 2 3 4
Zone
1 2 3 4
Step 3 - Activate the Sensor
+
-
Mute
Learn
Step 3
Alert
Chime
Off
Window/Door Sensor
Learn
Garage Door Sensor
Armed/Alarm Mode
Alarm System
- Only Sensors in Zones 1, 2, 3 will trigger alarm
- Arm/HOME - Instant alarm
- Arm/AWAY - Delay ALARM allows for exit
and re-entry
Note: Motion Sensor will only trigger alarm in AWAY Mode
Arm
Armed Power
1 2 3 4
Zone
Zones
Armed
HOME Mode
Step 1 - Enter four digit Security Code Step 2 - Press and Hold “Arm ” button
button until the Armed LED indicator turns on Note: Motion Sensors do not operate in
HOME Mode
To disarm Alarm, enter four digit Security Code. The Armed LED indicator will turn off.
Step 1 Step 2
Arm
Armed Power
1 2 3 4
Zone
Zones
1 2 3 4
AWAY mode
Step 1 - Enter four digit Security Code Step 2 - Press “Arm” button twice. The Armed
LED indicator begins flashing. You have 45 seconds to exit before Alarm is active
To disarm Alarm, enter four digit Security Code. The Armed LED indicator will turn off.
Step 1
Step 2
Arm
Armed Power
1 2 3 4
Zone
Zones
1 2 3 4
Armed
Notification Mode
- Only Sensors in Zones 1, 2, 3 will activate notifications
- Select from visual alert, single chime or continuous alert (beeping) when Sensor is activated
Three Mode settings
“Alert” - Continuous Tone “Chime” - Single Tone “Off” - Lights only
1 2 3 4
1 2 3 4
Zone
Zones
Example
Zone 1 - Front door & back door
Zone 2 - All windows Zone 3 - Gates & sheds
Input DC 12V
+
-
Mute
Learn
Arm
Armed Power
Alert
Chime
Off
Notification switches
Zone 4 - Alert OnlyZone 1, 2, & 3 Visual/Audio Alert
Dedicated Alert Mode
Zone 4 is designed to continuously monitor select areas. Sensors assigned to Zone 4 will immediately and automatically start monitoring. No special settings are required.
Note: Zone 4 is not controlled by Notification Mode switch, and does not activate alarm
Examples - water heater, garage door, back gate
Arm
Armed Power
1 2 3 4
Zone
1 2 3 4
Zone
Sensors in Zone 4
- When a Sensor is activated, the amber LED will flash and a continuous 4 beeps
will sound.
- To temporarily stop Alert (beeping) once Sensor has been activated, press “Mute”
button on Control Center.
- Sensor must be closed (i.e. door closed, water leak stopped) to discontinue Zone 4 notification
Input DC 12V
+
-
Mute
Mute
Learn
Arm
Armed Power
Alert
Chime
Off
1 2 3 4
Zone
Zone
Alarm SirenSilent Alert
Adding a Silent Alert
Install batteries Plug-in AC Adapter Step 1 - Press and hold the “Learn”
Input DC 12V
-
Mute
Learn
Alert
Chime
Off
Step 2
+
Mute
button on inside of the Silent Alert. The LED’s will begin to flash
Step 1
Step 2 - Press and hold the “Mute”
button on the Control Center for three seconds. The Control Center will sound 5 beeps, release “Mute” button
If the Silent Alert is in range, the LED’s will stop flashing. This indicates the Silent Alert has been added to the Control Center.
Adding an Alarm Siren
Step 1 - Press and hold the “Learn” button on inside of the Alarm Siren. The LED’s will begin to flash
Bottom of Alarm Siren
Step 2 - Press and hold the “Mute” button on the Control
Input DC 12V
-
Mute
Learn
Alert
Chime
Off
+
Mute
Center for three seconds. The Control Center will sound 5 beeps, release “Mute” button
If the Alarm Siren is in range the LED’s will stop flashing. This indicates the Alarm Siren has been added to the Control Center.
AC Adapter
Step 1
Zone indicators - Each number indicates a unique
zone. Each Zone can hold up to four Sensors. Any combination of Sensors types can be assigned to any of the four Zones.
Learn Button - Used to link Sensors and Accessories to the Control Cneter. Also sed to
change the Security Code. Number Buttons - Used to assign Sensors to Zone,
bypass Zones, and Arm/Disarm Alarm. Mute Button - Used to silence the Notification Alert.
Also used to send test signals to accessories. ARM Button - Used to ARM/DISARM. Also used for.
Also used for changing the Security Code.
See User’s Manual for more information.
Choice
Choice
Easy wireless alert products
ALERT
ALERT
for any budget!
Loading...