Gast R7100R-50 User Manual

Post Office Box 97 Benton Habor, MI 49023-0097 Ph: 616-926-6171 Fax: 616-925-8288
INSTALLATION
AND OPERATING
INSTRUCTIONS
DUTY REGENAIR
70-6100/F2-205
AK811 (Rev. G)
FOR GAST
HAZARDOUS
This instruction applies to the following models ONLY: R3105N-50, R4110N-50, R4310P-50, R4P115N-50, R5125Q-50, R5325R-50, R6130Q-50, R6P155Q-50, R6340R-50, R6P355R-50 and R7100R-50.
AUTHORIZED SERVICE FACILITIES
Gast Manufacturing Inc. 2550 Meadowbrook Road Benton Harbor, MI 49022 TEL: 616-926-6171 FAX: 616-925-8288 www.gastmfg.com
Wainbee Limited 215 boul Brunswick Pointe Claire, Quebec Canada H9R 4R7 TEL: 514-697-8810 FAX: 514-697-3070
Gast Manufacturing Inc. 505 W ashington Avenue Carlstadt, NJ 07072 TEL: 201-933-8484 FAX: 201-933-5545 www.gastmfg.com
Wainbee Limited 5789 Coopers Avenue Mississauga, Ontario Canada L4Z 3S6 TEL: 905/568-1700 FAX: 905/568-0083 http://www.wainbee.ca
Brenner Fiedler & Assoc 13824 Bentley Place Cerritos, CA 90701 TEL: 800-843-5558 TEL: 310-404-2721 FAX: 310-404-7975 www.brenner-fiedler.com
Japan Machinery Co., Ltd Central PO Box 1451 Tokyo, 100-91 Japan TEL: 813 3573 5421 FAX: 813 3571 7865 or: 81-3-3571-7896
Gast Manufacturing Co., Ltd. Beech House Knaves Beech Business Centre Loudwater, High Wycombe Bucks, England HP10 9SD TEL: 011-44 1628 532600 F AX: 011-44 1628 532470 http://www.gastltd .com
NOTE: General correspondence should be
sent to—
Gast Mfg. Inc./A Unit of IDEX Corporation P O Box 97 Benton Harbor, MI 49023-0097
SAFETY
This is the safety alert symbol: m. When you see this sym­bol, be aware that personal injury or property damage is possible. The hazard is explained in the text following the symbol.
The following is an explanation of the three different types of hazards:
m DANGER Severe personal injury or death
will occur if hazard is ignored.
m WARNING Severe personal injury or death
can occur if hazard is ignored.
m CAUTION Minor injury or property damage
can occur if hazard is ignored.
Read the information carefully before operating. _____________________________________________
GENERAL INFORMATION
This instruction applies to the following models ONLY: R3105N-50, R4110N-50, R4310P-50, R4P115N-50, R5125Q-50, R5325R-50, R6130Q-50, R6P155Q-50, R6340R-50, R6P355R-50 and R7100R-50. These blowers are intended for use in Soil Vapor Extraction Systems. The blowers are sealed at the factory for very low leakage. They are powered with a U.L. listed electric motor Class 1 Div. 1 Group D for Hazardous Duty locations. Ambient temperature for normal full load operation should not exced 40C (1050F). For higher ambient operation, contact the factory.
Gast Manufacturing Incorporated may offer general application guidance: however, suitability of the particular blower and/or accessories is ultimately the responsibility of the user, not the manufacturer of the blower.
INSTALLATION
m DANGER Models R5325R-50, R6130Q-50,
R6340R-50, R5125Q-50, R6P155Q-50, R6P355R-50 and R7100R-50 use Pilot Duty Thermal Overload Protection. Con­necting this protection to the proper control circuitry is mandated by UL674 and NEC501. Failure to do so could/may result in an EXPLOSION. Se pages 3 and 4 for recommended wiring schematic for these models.
m WARNING Electric shock can result from bad
wiring. A qualified person must install all wiring, conforming to all required safety codes. Grounding is necessary.
m WARNING This blower is intended for use on soil
vapor extraction equipment. Any other use must be approved in writing by Gast Manufacturing, Inc.
Install this blower in any mounting position. Do no block the flow of cooling air over the blower and motor.
PLUMBING
Use the threaded pipe ports for connection only. They will not support the plumbing. Be sure to use the same or larger size pipe to prevent air flow restriction and overheating of the blower. When installing fittings, be sure to use pipe thread sealant. This protects the threads in the blower housing and prevents leakage. Dirt and chips are often found in new plumbing. Do not allow them to enter the blower.
NOISE
Mount the unit on a solid surface that will not increase the sound. This will reduce noise and vibration. We suggest the use of shock mounts or vibration isolation material for mounting.
ROTATION
The Gast Regenair Blower should only rotate clockwise as viewed from the electric motor side. The casting has an arrow showing the correct direction. Confirm the proper rotation by checking air flow at the IN and OUT ports. If needed reverse rotation of three phase motors by changing the position of any two of the power line wires.
OPERATION
m WARNING Solid or liquid material exiting the
blower or piping can cause eye dam­age or skin cuts. Keep away from air stream.
m WARNING Gast Manufacturing, Incorporated will
not knowingly specify, design or build any blower for installation in a hazard­ous, combustible or explosive location without a motor conforming to the proper NEMA or U.L. standards.
Blowers with standard TEFC motors should never be utilized for soil vapor extraction applications or where local, state and / or Federal codes specify the use of explosion-proof motors (as defined by the National Electric Code, Articles 100,500 c1990).
m CAUTION Attach blower to solid surface before
starting to prevent injury or damage from unit movement.
Air containing solid particles or liquid must pass through a filter before entering the blower. Blowers must have filters, other accessories and all piping attached before starting. Any foreign material passing through the blower may cause internal damage to the blower.
2
Loading...
+ 2 hidden pages