Garmin FA168CPS User Manual

FA168CPS / FA168CPSSIA
S
S
r
r
S
S
FA168CPS / FA168CPSSIA
FA168CPS / FA168CPSSIAFA168CPS / FA168CPSSIA
FA148CP / FA148CPSIA
FA148CP / FA148CPSIA
FA148CP / FA148CPSIAFA148CP / FA148CPSIA
u
eeccu
READY
D E
M R A
R
STAY
3
AWAY
2
OFF
1
BYPASS
A
6
TEST
5
MAX
4
CHIME
B
9
CODE
8
INSTANT
7
C
#
0
READY
D
FA260
ON
ARMED
R E
A D
Y
R
A
W
A
Y
OFF
1
AWAY
2
STAY
3
S
T
A Y
MAX
4
TEST
5
BYPASS
6
INSTANT
7
CODE
8
CHIME
9
P
A
G
E
READY
0
#
FA560
y
iitty
yysstteem
mss
K5309-5V5 11/08 Rev. A
Users Guide
1
IMPORTANT!
PROPER INTRUSION PROTECTION
For proper intrusio n coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include an y skylights that may be
present, and the upper windows in a multi-l ev el bu il din g. In addition, we recommend that radio backup be used in a security system so that
alarm signals can still be s ent to the Central Monitoring Station in the e vent that the telephone lines are out of order (alarm signals are normally sent over the phone lines).
EARLY WARNING FIRE DETECTION
Early warning fire d etection is important in a hom e. Smoke and heat detectors have played a key role in reducing fire deaths in the United States. With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations c ontain ed in the Nati onal F ire Pro te ction As soc iation's Na tiona l F ire Alarm Code (NFPA 72). These recommendations can be found on page 45 of this manual.
SYSTEM COMPATIBILITY NOTICE
Your Honeywell secur ity system is designe d for use with devices manufactured or approved by Honeywell f or use with your securit y system. Your Hone ywell security system is not designed for use with any device that may be attached to your security system's keypad or other communicating bus if Honeywell has not approved such device for use with your security system. Use of any such unauthorized device may cause damage or compromise the performance of your security system and aff ec t the val idit y of your Hon e ywe ll l imited warranty. When you purchase devices that have been manufactured or approved by Honeywell, you acquire the assurance that these devices have been thoroughly tested to ensure optimum performance when used with your Honeywell security system.
About This Manual
This manual is a step-b y-step guide that will acquaint you with the system's features and benefits. It def ines the components and their func tions, desc ribes their o peration, and provides clear step-by-step instructions for normal and emergency procedures. Keep this manual in a convenient place so that you can refer to it as necessary.
– 2 –
Table of Contents
Table of Contents
Table of ContentsTable of Contents
System Overview....................................................................................................................5
Introduction ..........................................................................................................................5
System Basics .......................................................................................................................5
Using the Voice Message Center.........................................................................................7
About The Keypads.............................................................................................................. .. 8
General Information.............................................................................................................8
Functions of the Keypads...................................................................................................10
Entry/Exit Delays .................................................................................................................12
Exit Delay............................................................................................................................12
Entry Delay.........................................................................................................................12
Exit Alarms.........................................................................................................................13
Checking For Open Zones..................................................................................................14
Using the [∗] Key................................................................................................................14
Arming the System...............................................................................................................15
Stay Mode: Arms Perimeter Only, Entry Delay On.........................................................15
Night-Stay Mode: Arms Perimeter Only, Plus Selected Zones ....................................... 15
Instant Mode: Arms Perimeter Only, Entry Delay Off....................................................15
Away Mode: Arms Entire System, Entry Delay On.........................................................15
Maximum Mode: Arms Entire System, Entry Delay Off.................................................15
Arming Commands.............................................................................................................16
Single Button Arming ........................................................................................................17
Single-Button “Step” Arming............................................................................................. 17
Using the Keyswitch............................................................................................................18
Using the Keyswitch........................................................................................................... 18
Disarming and Silencing Alarms .....................................................................................19
Using the [OFF] key...........................................................................................................19
Bypassing Protection Zones ..............................................................................................20
Using the BYPASS Key......................................................................................................20
Quick Bypass ......................................................................................................................21
Chime Mode...........................................................................................................................22
Date and Time.......................................................................................................................23
Viewing the Current Date and Time.................................................................................23
Setting the Date and Time................................................................................................. 23
– 3 –
Table of Contents
Table of Contents
Table of ContentsTable of Contents
Panic Keys..............................................................................................................................24
Macro Key Programming & Usage...................................................................................25
About Macro Keys............................................................................................................... 25
Example of Macro Programming....................................................................................... 26
Using a Programmed Macro Key....................................................................................... 26
Using Device Commands....................................................................................................27
Paging Feature .....................................................................................................................28
About Automatic Paging ....................................................................................................28
Manual Paging....................................................................................................................29
Latch Key Paging ...............................................................................................................29
Security Codes & Authority Levels..................................................................................30
About Security Codes .........................................................................................................30
Authority Level Definitions ...............................................................................................30
How To Assign Security Codes and Attributes................................................................. 31
Accessing Other Partitions (GOTO Command and Multi-Partition Arming)......32
About Accessing Partitions................................................................................................32
Using the GoTo Command.................................................................................................33
Multi-Partition Arming......................................................................................................33
Common Zone Operation.................................................................................................... 34
Scheduling .............................................................................................................................35
About Scheduling................................................................................................................35
Creating Schedules.............................................................................................................35
Event Logging Procedures.................................................................................................37
About Event Logging..........................................................................................................37
Viewing the Event Log ....................................................................................................... 37
Testing the System (To Be Conducted Weekly)............................................................38
Trouble Conditions..............................................................................................................39
Maintaining Your System...................................................................................................42
Fire Alarm System (If Installed).......................................................................................43
Quick Guide to Basic System Functions ........................................................................ 47
Summary of Audible/Visual Notifications......................................................................48
Regulatory Statements and Warnings ............................................................................50
Charts of Your System's Features....................................................................................52
– 4 –
Introduction
Introduction
IntroductionIntroduction
Congratulati ons on your ownership of a Fir st Alert Profession al S ecu r ity Sy st em. You' ve made a wise decision in choosing it, for it represents the latest in security protection technology today. This system provides:
Three forms of protection: burglary, fire* and emergency
At least one keypad which provides control of system and displays system status
Various sensors for perimeter and interior burglary protection
Smoke or combustion detectors* designed to provide early warning in case of fire. Your system may also have been programmed to automatically send alarm or status messages over the phone lines to a Central Monitoring Station.
* Commercial installations and some residential systems may not include fire protection – check with your installer.
NOTE: The features and procedures described in this manual apply to the FA168CPS/FA168CPSSIA (referred to as FA168CPS) and FA148CP/FA148CPSIA (referred to as FA148CP) security systems. Differences are noted where applicable.
System Basics
System Basics
System BasicsSystem Basics
Burglary Protection
Several modes of burglary protection: Stay, Night-Stay, Away, Instant, Maximum. STAY: arms perimeter zones only and entry delay is on INSTANT: same as STAY, except entry delay is off NIGHT-STAY: arms perimeter zones and selected interior zones; entry delay on AWAY: arms perimeter and all interior zones, entry delay is on MAXIMUM: same as AWAY, except entry delay is off
You can BYPASS selected zones while leaving the rest of the system armed.
CHIME mode alerts you to the opening of protected doors and windows while the system is disarmed .
Fire Protection
Fire protection is always active (if installed) and an alarm sounds if a fire condition is detected
If programmed, you can manually initiate a fire alarm using the keypad.
Refer to the Fire Alarm System section for information regarding fire protection, smoke detectors and planning emergency exit routes.
Security Codes
You were assigned a 4-digit security code (master code) during installation.
Use your security code when arming and disarming the system, and when performing other system fun ctions.
Other users can be assigned different security codes, each with different authority levels, which define the system functions a particular user can perform.
Sys
System Overview
SysSys
tem Overview
tem Overviewtem Overview
– 5 –
System Overview
System Overview
System Overview System Overview
Zones and Partitions
The system sensing devices have been assigned to various “zones,” which are specific areas of protection (e.g., front door, kitchen window, etc.).
Zone numbers are displayed at the keypad when an alarm or trouble condition occurs on a sensor.
Partitions (FA168CPS) provide two independent areas of protection, with each partition containing a group of zones that can be armed and disarmed without affecting other z on e s or us ers.
Partitioned systems (FA168CPS) can include a common zone area, which is an area shared by users of both partitions (such as a lobby in a building).
Arming, Step-Arming and Disarming Burglary Protection
The system must be armed before the burglary protection can sense intrusions.
To arm your system, enter your security code followed by the desired arming key.
If programmed, you can press the [#] key in place of your security code when arming the system (e.g., instead of entering your 4-digit security code + [3-STAY] to arm the system in STAY mode, you can press [#] + [3-STAY]).
You can use the step-arming key, if programmed, to arm the system, which lets you arm the system in one of three modes by simply pressing the key repeatedly.
To disarm the system, enter your security code then press the [OFF] key.
Alarms
When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm.
If your system is connected to a Central Monitoring Station, an alarm message is also sent. (Delayed Reporting Note: Message reporting is delayed 30 seconds by default to reduce false alarms. If desired, this delay can be removed or can be increased to 45 seconds. See your installer if you want the delay time changed.)
To stop the alarm sound in g , simply di sarm th e sys te m .
Memory of Alarm
When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (e.g., “FIRE”).
The message remains displayed even after disarming the system, but can be cleared with another “off” sequence.
Function Keys
The “A”, “B”, “C”, and “D” keys on the keypad can be programmed to perform various functions.
Functions include: activate a Panic alarm; arm the system; provide step arming; switch lights on/off; send a message to a pager; display Time/Date; start a Macro.
Scheduling
Your system can be programmed to automatically perform certain functions (e.g., arm the system) at a predetermined time each day.
(Continued)
(Continued)
(Continued)(Continued)
– 6 –
System Overview
t
System Overview
System Overview System Overview
(Continued)
(Continued)
(Continued)(Continued)
Phone Access
If included, a Phone Module permits you to access the system via a touch-tone phone, either on-premises or by calling-in when aw a y .
You can receive synthesized voice messages over the telephone regarding the status of the secur ity sy st em .
You can arm and disarm the system and perform most function commands remotely via the telephone, with voice confirmation provided after each command.
Refer to the Phone Access User's Guide supplied with the Phone Module for information regarding the use of this feature.
Paging Feature
If programmed, the system can automatically send certain system condition messages to up to four (FA168CPS) or two (FA148CP) pagers.
The system can also automatically alert a pager if the system has not been disarmed by a certain time (e.g., can let you know a child has not arrived home).
You can also manually send a message to designated pagers.
Using the Voice Message Center (if Voice Keypad is installed)
Using the Voice Message Center (if Voice Keypad is installed)
Using the Voice Message Center (if Voice Keypad is installed)Using the Voice Message Center (if Voice Keypad is installed)
The Voice Keyp ads fe ature a voic e mess age cen ter
LEDS
that lets you record and playback one message.
The message can be up to 2.5-minutes long
The message remains in the keypad’s memory
until a new message is recorded.
The volume control of the message is adjustable.
Refer to the procedures below when using the
Message Center fu n ct i ons.
SPEAKER
RECORD
FUNCTION
KEYS
KEY
ARMED MESSAGEREADY
AWAY1OFF
A
2
VOLUME
RECORD
MAX
TEST
4
B
5
CODE
INSTANT
7
C
8
READY
0
D
STATUS
VOICE
*
FA560
LCD DISPLAY
VOLUME KEY
PLAY KEY AND UP VOLUME
STAY
3
PLAY
BYPASS
6
9
#
FUNCTION
DOWN
CHIME
VOLUME
FUNCTION KEY
STATUS
KEY
MICROPHONE
VOICE
KEY
FA560VKP-004-V0
Message Center Functions
To… Press these keys… Notes…
record a message
[#] FUNCTION + [0] VOICE + [1] RECORD
The red MESSAGE LED lights. Message remains in memory
until a new message is recorded.
end recording
play a message
adjust the volume
[1] RECORD
[#] FUNCTION + [0] VOICE + [3] PLAY
[#] FUNCTION + [0] VOICE + [2] VOLUME keys, then press volume key [3] (up) or [6] (down)
The red MESSAGE LED flashes, indicating message waiting.
The recorded message plays and
he red MESSAGE LED turns off.
Adjusting message volume also adjusts status volume. Volume cannot be adjusted while playing.
– 7 –
About T
About The Keypads
About TAbout T
he Keypads
he Keypadshe Keypads
General Information
General Information
General InformationGeneral Information
Your keypads allow you to control all syste m functi ons. The keypads feature the following:
A telephone style (digital) keypad
Liquid Crystal Display (LCD) which shows the nature and location of all
occurrences
Built-in sounder which will sound during alarms and troubles. The sounder also
"beeps" during certain system functions and when depressing any of the keys (to acknowledge the key press).
Backlighting of the LCD display windows. Backlighting turns on when any key is
pressed, and when opening an entry/exit door while the system is armed. This feature is helpful when a keypad is located in a dimly lit area.
IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
Your keypads are functionally the same, but may have different types of displays, depending on the type installed with your system.
Alpha Display 2-line alpha display keypads feature a 2-line, 32-character
alphanumeric LCD which can display system messages in friendly English. These keypads can also be programmed with
Fixed-Word Display Fixed-Word display keypads are functionally identical to Alpha
Voice Keypads Voice Keypads (if installed), are functionally the same as other
Voice announcements of system status (see Checking for
Voice chime, which can alert you to the opening of doors and
Message center, which lets you record and pla yback
custom zone descriptors.
display keypads, but the LCD display uses pre-designated words to identify the nature and location of occurrences.
keypads, except that these keypads can provide the following:
Open Zones section)
windows while the system is disarmed (see Voice Chime in Chime mode section)
messages (see Using the Voice Message Center in the System Overview section).
– 8 –
About The Keypads (Continued)
ALARM CHECK
NIGHTFIRE
NOT READY
STAY INSTANT
BYPASS
NO AC
CHIME
BAT
CANCELED
AWAY
00
About The Keypads (Continued)
About The Keypads (Continued)About The Keypads (Continued)
Fixed-Word Display Keypad
AWAY: All burglary zones, interior and
perimeter, are armed.
STAY: Perimeter burglary zones, such as
protected windows and doors, are
ALARM
CHECK INSTANT CANCELED
FIRE
armed. INSTANT: Entry delay is turned off: Lit with STAY = Instant mode
Lit with AWAY = Maximum mode BYPASS: This appears when one or more
burglary protection zones have been
bypassed.
FIXED-WORD DISPLAYS
NOT READY: Appears when burglary portion of the system is not ready for arming
(due to open protection zones). The system is ready to arm when this
message disappears and the READY indicator light comes on.
NO AC: Appears when AC power has been cut off. System is operating on
backup battery power.
AC: Appears when AC power is present. CHIME: Appears when the CHIME feature is acti vated.
BAT: Low battery condition in a wireless sensor (if zone number displayed)
or low system battery (if no zone number displayed).
ALARM: Appears when an intrusion has been detected and the system is armed
(also appears during a fire alarm or audible emergency alarm).
Accompanied by the protection zone in alarm.
CHECK: Appears when a malfunction is discovered in the system at any time or
if an open is detected in a FIRE zone at any time or a fault in a
DAY/NIGHT burglary zone during a disarmed period. Accompanied by
a display of zone number in trouble.
FIRE: Appears when a fire alarm is present. Accompanied by a display of the
zone in alarm.
A FIRE display also appears when a fire alarm is manually activated,
accompanied by a display of emergency key zone number programmed
for fire.
NIGHT: Appears with “STAY” when the system is armed in Night-Stay mode
(perimeter burglary zones and pre-selected interior zones are armed).
CANCELED: Appears when an alarm has been canceled (see Exit Alarm section on
page 13 for more information on canceled alarms and displays).
AWAY
BYPASS
STAY
FA260KP
FA215KP
NIGHT NO AC
PHONE TEST
NOT READY
CHIME BAT
– 9 –
Functions of the Keypads
Functions of the Keypads
Functions of the KeypadsFunctions of the Keypads
NOTE: The functions printed directly on the keys indicate their primary purpose; the functions printed u nder some of th e keys (sh own in brackets under the respective key), indicate their alternate or secondary purpose.
DISPLAY WINDOW
Alpha Display Keypads: 2-line, 32-character
Liquid Crystal Display (LCD) keypads that display protection point identification, system status, and messages.
Fixed-Word Display Keypads: Display
protection zone ID and system status messages using pre-designated words in the LCD display area.
1 OFF
silences alarms and audible trouble indicators, and clears visual display after problem's correction.
Disarms burglary portion of the
[RECORD] On Voice keypads, used in conjunction
with the FUNCTION and VOICE keys to record up to a 2.5-minute message.
2 AWAY
perimeter and interior.
Arms the entire burglary system,
[VOLUME] On Voice keypads, used in conjunction
with the FUNCTION and de sired volume control keys [3] or [6] to adjust the volume of a recorded message or voice system status.
3 STAY Arms perimeter portion of burglary
system only. Interior protection is not armed, allowing movement within premises without causing an alarm. If pressed twice in succession, arms system in Night­Stay mode.
[PLAY] On Voice keypads, used in conjunction with
the FUNCTION and VOICE keys to play the recorded message.
[ ] On Voice keypads, used in conjunction with the
FUNCTION and VOLUM E ke ys t o rai se th e m essa ge and voice system status volume.
4 MAXIMUM
perimeter and interior, but without entry delay feature. Entering via an entry/exit door will cause an alarm.
Arms the entire burglary system,
5 TEST Tests the system and alarm sounder if
disarmed. Refer to Testing The System section for test procedures.
system,
6 BYPASS Removes individual pro te ction zones
from being monitored by the system.
[ ] On Voice keypads, used in conjunction with the
FUNCTION and VOLUME keys to lower the message and voice system status volume.
7 INSTANT Arms in manner similar to the STAY
mode, but without the entry delay feature.
9 CHIME Turns
the opening of windows or doors while the system is disarmed sounds 3 beeps at the keypad(s).
KEYS 0–9: Used to enter your security code(s).
READY Used to display open protection zones.
[STATUS]: On Voice keypads, one press of the
STATUS key annunciates the current system status. Pressing the STATUS key a second time annunciates and displays system and/or zone faults (if they exist).
0 [VOICE] On Voice keypads, enables t he
RECORD, VOLUME and PLAY functions.
# This key can be used for "Quick Arming" of the
system withou t us e of a security code (if programmed).
[FUNCTION] On Voice keypads, enables the desired
voice or volume function.
FUNCTION KEYS: Keys A, B, C, D may have been
set for certain functions, such as panic (emergency) functions. For details, see the Fun ction Keys section.
ARMED LED INDICATOR: (RED) Lit when the
system has been armed.
READY LED INDICATOR: (GREEN) Lit when
the system is ready to be armed (no faults present). While the system is disarmed, this indicator will go on and off as protection zones are closed and opened.
MESSAGE LED INDICAT OR: (RED) On Voice
keypads, flashes red when message waiting or lights red (steady) when in record mode.
MIC: On voice keypads, microphone for Message
Center recordings.
INTERNAL SPEAKER: The built-in speaker
mimics the alarm sounder during alarms, and will also "beep" during certain system functions. The speaker also provides voice playback for any recorded messages.
8 CODE Used to assign additional security codes
and attributes for other users of the system.
CHIME mode on and off.
When on,
– 10 –
Functions of the Keypads (Continued)
Functions of the Keypads (Continued)
Functions of the Keypads (Continued)Functions of the Keypads (Continued)
LEDS
LCD DISPLAY
ARMED MESSAGEREADY
SPEAKER
STAY
AWAY
OFF
1
RECORD
MAX
4
INSTANT
7
READY
STATUS
*
FA560
2
VOLUME
5
8
0
VOICE
TEST
CODE
3
PLAY
BYPASS
6
CHIME
9
#
FUNCTION
FUNCTION
KEYS
A
B
C
D
MICROPHONE
FA560VKP-003-V0
Voice-capable 2-line Alpha keypad
IMPORTANT!
When entering codes and commands, sequential key depressions must be made within 4-5 seconds of one another. If 4-5 seconds elapse without a key depression, the entry will be aborted and must be repeated from its beginning. Be sure to observe this precaution when performing any of the procedures in this manual.
If you make a mistake while entering a security code, stop, press the [] key, and then start over. If you stop in the middle while entering a code, and then immediately start the entry over, an erroneous code might be entered.
– 11 –
Entry/Exit Delays
Entry/Exit Delays
Entry/Exit DelaysEntry/Exit Delays
Exit Delay
Exit Delay
Exit DelayExit Delay
Exit delay gives you time to leave through the designated exit door(s) without setting off an alarm. Exit delay begins immediately after arming your system in any arming mode and Alpha Display keypads display the message “You May Exit Now.” When “You may exit now” disappears, the system is fully armed. If programmed, a slow beeping will sound during the exit delay period until the last 10 seconds, which then changes to fast beeping (alerting you to the end of exit delay). If you cannot leave by this time, you should st op , disarm the system, and start over to avoid a false alar m .
Exit Delay Restart. If you wish to open the entry/exit door to let someone in after arming STAY, you can re-start the exit delay at any time – simply press the [] key, then let that person in (the perimeter zones remain armed). The system
automatically re-arms the entry/exit door when exit delay expires, which avoids having to disarm the system and then re-arm it again. In addition, when the system is armed AWAY, reopening and closing the entry/exit door before exit delay time expires (e.g., reentering to get a forgotten item) will reset the exit delay time once.
Entry Delay
Entry Delay
Entry DelayEntry Delay
Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. There are two entry delays (if programmed). The first is for your primary entrance and the second can be used for a secondary entrance, where a longer delay is required to walk to the keypad to disarm the system.
You must disarm the system before the entry delay period ends, or an alarm will occur. The keypad beeps during the entry delay period, reminding you to disarm the system. The beeps stop when a code is entered, but will restart after about 15 seconds if an invalid code is entered.
You can also arm the system with no entry delay at all by using the INSTANT or MAXIMUM arming modes. These modes provide greater security while on the premises or while away for extended periods of time.
You can also arm the system with no entry delay at all by using the INSTANT or MAXIMUM arming mode. This mode provides greater security while on the premises or while away for extended periods of time.
See your installer for your delay times.
Partition 1____________________________________________________________________________
– 12 –
Exit Delay:
Partition 2 (FA168CPS)_______________________________________________________________
Exit Delay: seconds Entry Delay 1: seconds Entry Delay 2: seconds
seconds; Entry Delay 1: seconds; Entry Delay 2: seconds
NOTE: Entry/Exit times set for partition 1 also apply to the common zone (FA168CPS).
Exit Alarms
Exit Alarms
Exit AlarmsExit Alarms
Exit Error Conditions
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted before exit delay expires and remains faulted (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the message "ALARM CANCELED " or "CA" is displayed on the keypad, along with a zone number indicating the faulted zone. No message is sent to the Central Monitoring Station.
To clear the exit error condition, the open zone must be made intact; to clear the display, enter your code plus OFF.
If you do not disarm the system before the entry delay ends and the faulted zone remains open, the alarm sound continues and an "exit alarm" message is sent to the Central Monitoring Station (after the installer-programmed dial delay expires). T he message "EXIT ALARM" or "EA" is displayed on the keypad, along with a zone number indicating the faulted zone. To stop the alarm, the system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF a second time.
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay.
Your system may have been programmed for this feature to minimize false alarms sent to the Central Monitoring Station. Ask your installer if "Exit Alarm" is active i n your syst em. If so, check thi s box.
FA168CPSSIA/FA148CPSIA: The Exit Error condi t ion works the same as described above, except that in addition to the “EXIT ALARM” message, a “zone alarm” message is also sent to the Central Monitoring Station. In addition, if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay, a “Recent Closing” cond ition occurs instead of the “exit alarm.” Refer to the next paragraph for details.
“Recent Closing” Condition (FA168CPSSIA/FA148CPSIA)
A Recent Closing condition is similar to the Exit Error condition described a bove, but occurs if an entry/exit door or interior zone is faulted within two minutes after the initial exit delay expires. If you disarm the system within the two minutes, the alarm sound stops and the message "ALARM CANCELED " or "CA" is displayed on the keypad, along with a zone number indicating the faulted zone. No message is sent to the Central Monitoring Station.
If you do not disarm the system within two minutes and the faulted zone remains open, the alarm sound continues and a “recent closing” and a “zone alarm” message are sent to the Central Monitoring Station (after the installer-programmed dial delay expires). The alarm message along with a faulted zone number is displayed on the keypad. To stop the alarm, the system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF a second time.
Entry/Exit Delays
Entry/Exit Delays
Entry/Exit Delays Entry/Exit Delays
(Continued)
(Continued)
(Continued)(Continued)
– 13 –
Checking For Open Zones
Checking For Open Zones
Checking For Open ZonesChecking For Open Zones
Using the [
Using the [∗∗∗] Key
Using the [Using the [
] Key
] Key] Key
Before arming your system, all protected doors, windows and other protection zones
must be closed or bypassed, otherwise the keypad will display a "Not Ready" message. Use the READY key to display all faulted zones, making it easier for you to identify
and secure any open zone.
1. Press [] (do not enter code first) to display faulted zones.
2. Secure or bypass the zones displayed.
3. The keypad’s READY indicator lights when all
protection zones have been either closed or bypassed.
4. Arm the system as desired.
Voice Status: Voice Keypads (if installed), can announce system status and faulted zones (up to 3 zone descriptors) if the Voice Status feature is turned on.
To turn the Voice Status feature on/off:
(also turns on Voice Chime mode; see Chime mode section)
To announce Status: Press [#] FUNCTION + [0] VOICE + [] STATUS key. (Announces current system status; e.g., “Disarmed Ready to
Arm.”)
To announce faults Press [#] FUNCTION + [0] VOICE + [] STATUS + [] again. and Status: (Announces up to three faulted zones with their zone
descriptors, if programmed.)
# + 0 + 2 + 4
Alpha Display:
DISARMED HIT FOR FAULTS
Fixed-Word Display:
Zone no. and “NOT READY”
– 14 –
Arming the System
Arming the System
Arming the SystemArming the System
Stay Mode: Arms Perimeter Only, Entry Delay On
Stay Mode: Arms Perimeter Only, Entry Delay On
Stay Mode: Arms Perimeter Only, Entry Delay OnStay Mode: Arms Perimeter Only, Entry Delay On
Used when you want to arm the system with persons staying inside (or if you have pets that are moving throughout the premises).
The perimeter sensors are armed, but interior sensors are left disarmed.
Exit delay begins (you can leave through the entry/exit door, if desired).
An alarm sounds if any protected window or non-entry/exit door is opened.
You may otherwise move freely within the premises.
Persons entering later can enter through an entry/exit door, but they must disarm
the system within th e entry delay period to avoid sounding an alarm.
Night
Night----Stay Mode: Arms Perimeter Only, Plus Selected Zones
NightNight
Instant Mode: Arms Perimeter Only, Entry Delay Off
Instant Mode: Arms Perimeter Only, Entry Delay Off
Instant Mode: Arms Perimeter Only, Entry Delay OffInstant Mode: Arms Perimeter Only, Entry Delay Off
Away Mode: Arms Entire System, Entry Delay On
Away Mode: Arms Entire System, Entry Delay On
Away Mode: Arms Entire System, Entry Delay OnAway Mode: Arms Entire System, Entry Delay On
Maximum Mode: Arms Entire System, Entry Delay Off
Maximum Mode: Arms Entire System, Entry Delay Off
Maximum Mode: Arms Entire System, Entry Delay OffMaximum Mode: Arms Entire System, Entry Delay Off
Stay Mode: Arms Perimeter Only, Plus Selected Zones
Stay Mode: Arms Perimeter Only, Plus Selected ZonesStay Mode: Arms Perimeter Only, Plus Selected Zones
Use Night-Stay mode to provide increased security while staying inside.
Arms same as Stay mode, but also arms pre-selected interior sensors (programmed
by your installer), while other interior sensors are left disarmed.
Persons entering later can use entry/exit doors but they must disarm the system and must not violate any of the programmed interior zones to avoid sounding an alarm.
IMPORTANT: When Night-Stay mode is on, the selected interior zones are armed and cause an alarm if anyone enters those areas (e.g., waking in the middle of the night). To avoid sounding an alarm, you must disarm the system before any activity takes place in those interior zones.
Used when staying inside and do not expect anyone to use an entry/exit door.
Arms same as Stay mode.
An alarm sounds immediately if any protected perimeter window or any door is
opened, including entry/exit doors.
IMPORTANT: Arming in this mode greatly increases the chance of false alarms. Use extreme care in selecting this mode of arming.
Used when nobody will be staying ins ide (including pets).
The entire system (interior and perimeter) is armed.
Exit delay begins letting you leave through the entry/exit door.
An alarm sounds if a protected window or any door is opened, or if any movement
is detected inside your premises.
You can reenter through an entry/exit door, but you must disarm the system within the entry delay period to avoid sounding an alarm.
Used when leaving the premises for extended periods (e.g., vacation).
Arms same as Away mode, but entry delay is off.
An alarm sounds same as Away mode, and sounds upon opening entry/exit doors.
– 15 –
Arming the System
Arming the System
Arming the SystemArming the System
Arming Commands
Arming Commands
Arming CommandsArming Commands
Before arming, close all perimeter doors and windows and make sure the Ready to Arm message is displayed.
Modes of Arming
Mode Press these keys… Keypad Confirms By…
Stay security code + [3] (STAY)
Night-Stay security code + [3] + [3]
Instant security code + [7] (INSTANT)
Away security code + [2] (AWAY)
Maximum security code + [4] (MAXIMUM)
Arming Ding: In addition to the keypad beeps, the external sounder emits a short “ding” sound after arming, if
programmed to do so. T he ding confirms that the system is arme d, and may occur immediately after t he command or be delayed (until arm/disarm report is sent or exit delay expires). Ask your installer about how this feature is set for your system.
Quick Arming
If "Quick Arming " was pr ogramm ed by th e insta ller, th e of the security code wh en arm ing the system in any of its armi ng m odes (exc ept Nig ht­Stay). However, the security code must always be used when manually
disarming the system. Function Key Arming
For any arming command , a function key may have also been programmed for your system. If so, you can press and hold the appropriate function key for 2 seconds to arm the system. See your installer for the designated functions (see Single Button Arming section).
Refer to the Accessing Other Partitions section for information on mu lti-partition arming (FA168CPS).
three beeps
armed STAY message displayed
red ARMED indicator lights
three beeps
NIGHT-STAY message displayed
red ARMED indicator lights
three beeps
armed STAY message displayed
red ARMED indicator lights
also note that entry delay is turned off.
two beeps
duration of exit dela y
armed AWAY message displayed
red ARMED indicator lights
Leave the premises through an entry/exit door during the exit delay period to avoid causing an alarm. The keypad beeps rapidly during the last 1 0 seconds of the exit delay to warn you that it is ending.
same as Away (described above) Note that entry delay is turned off.
, or, if programmed, beeping for
[#] key can be pressed in place
– 16 –
Single Button Arming
Single Button Arming
Single Button ArmingSingle Button Arming
The “A”, “B”, “C”, and/or “D” keys on your keypad may have been programmed for single-button arming. Note that while it is not necessary to use a security code for arming (by using the Quick Arm method described previously), a security code must always be used when manually disarming the system.
If Single-Button Arming is programmed:
A function key has been assigned to a specific type of arming: STAY mode,
Night-STAY mode, AWAY mode, or STEP-ARMING (see Step-Arming paragraph).
You DO NOT need to enter your security code before pressing the function key
(but you always need your security code to DISARM the system).
Before arming, close all perimeter doors and windows.
1. Press and hold the assigned function key for 2 seconds (no code is required). Function key s are shown below.
A
B
C
D
2. The keypad begins beeping and displays the armed message. The red ARMED indicator also lights.
Step Arming Feature
Step Arming Feature
Step Arming FeatureStep Arming Feature
Single-Button “Step” arming may have been programmed into one of the lettered keys (A, B, C, or D). Check with your installer to see if this has been done in your system.
If Step-Arming is programmed:
The assigned key provides a choice of three levels of security.
The selected key can be pressed once, twice, or three times, increasing the level of security with each press, as follows
Key
Ø
A, B, C, D
Arming the System
Arming the System
Arming the SystemArming the System
Alpha Display:
DISARMED
OFF
AWAY
STAY
321
TEST
CODE
BYPASS
654
CHECK
987
#0
keypad_keys-00-001-V0
MAX
INSTANT
READY
*
READY TO ARM
Fixed-Word Display: READY
Alpha Display:
ARMED***AWAY*** YOU MAY EXIT NOW
Fixed-Word Display: AWAY
First Press
Ø
Armed-STAY Armed Night-STAY
Second Press
Ø
(if programmed)
Third Press
Ø
Armed-AWAY
– 17 –
Using the Keyswitch
Using the Keyswitch
Using the KeyswitchUsing the Keyswitch
Using the Keyswitch
Using the Keyswitch
Using the KeyswitchUsing the Keyswitch
Your system may be equipped with a keyswitch for use when arming and disarming. Red and green lights on the keyswitch plate indicate the status of your system as follows: Green Light: Lights when the system is disarmed and ready to be armed (no
open zones). If the system is disarmed and the green light is off, it indicates the system is not ready (one or more zones are open).
Red Light: Lights or flashes when system is armed in AWAY or STAY mode.
See your installer for the meanings of the lit red light:
Lit Steady = system arm ed AWAY or
system armed STAY and exit delay has e xpired Flashing = system armed STAY and exit delay timer active Rapid flashing = an alarm has occurred (memory of alarm).
Before arming, close all perimeter doors and windows.
To arm in the AWAY mode:
Turn the key to the right for 1/2 second and release.
Keypads beep twice and the red indicator lights or flashes.
To arm in the STAY mode:
Turn the key to the right and hold for longer than 1
second, then release. Keypads beep three times and the red indicator lights or flashes.
To disarm the system:
Turn the key to the right and release. The red light
turns off
– 18 –
Using the [OFF] key
Using the [OFF] key
Using the [OFF] keyUsing the [OFF] key
The OFF key is used to di sar m th e sy s tem, silence alarm and trou b le sou n ds, and clear alarm memories.
IMPORTANT: If you return and the main burglary sounder is o n, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location. If you return after an alarm has occ urr ed and t he main sounder has shut its elf off , the keypad will
beep rapidly upon your entering, indicating that an alarm has occurred during your absence.
LEAVE AT ONCE, and CONTACT THE POLICE from a nearby safe location.
1.
+ 1
Disa
Disarming and Silencing Alarms
DisaDisa
rming and Silencing Alarms
rming and Silencing Alarmsrming and Silencing Alarms
Alpha Display:
(Security Code) OFF
The “READY” indicator light will be lit if all zones
are secure, and the keypad will emit a single tone to confirm that the system is disarmed.
NOTE: If entry delay has started (you’ve opened the
entry door), you do not need to press the OFF key; simply enter your security code. The system will disarm in about 15 second s aft er the las t dig i t of the code is entered.
2. To Silence a Burglary Alarm and Clear a Memory of Alarm Enter your security code. This disarms the system and silences the alarm (or
warning tones of a Memory of Alarm).
Note the zone in alarm on the keypad display, and make that zone intact (close
door, window, etc.). Now enter the security code plus OFF to clear the keypad’s Memory of Alarm display.
3. To Silence a Fire Alarm or Carbon Monoxide Alarm and Clear Memory of Alarm
Simply press the OFF key to silence the alarm. Then enter the security code plus
OFF sequence to clear the keypad's Memory of Alarm display. See the Fire Alarm
System section.
DISARMED READY TO ARM
Fixed-Word Display: READY
– 19 –
Bypassing Protection Zones
Bypassing Protection Zones
Bypassing Protection ZonesBypassing Protection Zones
Using the BYPASS Key
Using the BYPASS Key
Using the BYPASS KeyUsing the BYPASS Key
Use this key when you w ant t o arm y our syst em wi th on e or mor e zon es in ten tion ally
unprotected. Vent Zones: Your system m ay have certain wind ows set as “vent” zon es, which are
automatically bypassed if left open when arming the system (you do not need to manually bypass them). However, if a vent zone window is closed after arming, it becomes protected and will cause an alarm if opened again while the system is armed.
When bypassing zone s:
The system must be disarmed before you can bypass zones.
Bypassed zones are unprotected and will not cause an alarm if violated.
The system will not allow fire zones to be bypassed.
Zones are automatically unbypassed when the system is disarmed.
1.
+ 6 + zone numbers (see below)
Alpha Display:
(Security Code) BYPASS
Enter the 2-digit zone number(s) for the zone(s) to be
bypassed (e.g., 06, 10, 13, etc.). Single digit zone numbers must be preceded by a zero (e.g. 05, 06).
2. When finished, the keypad will momentarily display a "Bypass" message for each bypassed zone number. Wait for all bypassed zones to be displayed.
Arm the system as usual. When armed, the arming
message is displayed with “ZONE BYPASSED.”
To display bypassed zones prior to arming, enter
your security code and press the [6] BYPASS key.
DISARMED HIT * FOR FAULTS
Fixed-Word Display: NOT READY
Alpha Display:
DISARMED BYPASS READY TO ARM
Fixed-Word Display: BYPASS
ARMED: STAY ZONE BYPASSED
Typical armed alpha display after bypassing zones.
– 20 –
Loading...
+ 44 hidden pages