Important S afety Instructions

1. Read, follow, and retain instructions – All safety and operating instructions should be read and followed before operating the unit.
Retain instructions for future reference.
2. Heed warnings – Adhere to all warnings on the unit and in the operating instructions.
3. Attachments – Attachments not recommended by the product manufacturer should not be used, as they may cause hazards.
4. Servicing – Do not attempt to service this unit by yourself. Opening or removing covers may expose you to dangerous voltage or
other hazards. Refer all servicing to qualified service personnel.
5. This permanently connected apparatus must have a UL Listed 15-amp circuit breaker incorporated in the electrical installation of
the building.

General Inf ormation and Available Options

This guide covers the installation of the ICS Page/Party
®
Station. Figure 1 shows configurations with the following options:
Universal ac or 24 V
dc power
Single or multi-party
system, or amplifier only
All Call SmartSeries Alternate page
destination
Emergenc y party line Auxiliary jack VLC RTU
70V / 100V speaker
Figure 1. ICS Station with available options (AC Version shown)
All ICS Stations are wired in parallel. Good system layout design minimizes the cable required. Refer to Pub. 42004-717L2 at the “Manuals & Specs” link at www.gai-tronics.com system design information, and warranty.
for detailed explanations of the available configuration options and adjustments,
output
Mounting and Wiring
Mount the enclosure using the four 0.312-inch (8 mm) diameter holes located on the mounting flanges with ¼-inch (M6) hardware. The standard orientation (shown in Figure 1) locates the power supply housing in the upper left co rner. The orientation of the enclosure can be rotated 180º to allow clear access on the top. The Termination PCBA can then be rotated for correct orientation.
Remove front panel and drill or punch wire entry openings in the rear enclosure. See Figure 2 for suggested locations. There must be a minimum of ½ inch (12.7 mm) of material between wire entry holes. The recommended entry is via the enclosure bottom to prevent moisture from dripping onto the terminals. Avoid the top left as it may interfere with the power supply. Basic wiring connections are shown on Figure 3. Use GAI-Tronics 60029 series multi-party cable or 60038 series single party cable terminated with #6 spade lugs. Torque the terminal block screws to 8–10 in-lbs (0.90–1.13 n-m) when attaching the spade lugs.
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
®
A
V
ICS Page/Party
Station Quick Installation Guide Page 2 of 2

Available A djustments

Most optional equipment is preconfigured to a default standard at the factory. The following is a partial list of the available adjustments and settings that may be needed:
Pub. 42004-717L2GQG
Main PCB
Speaker Volume Speaker Volume FSK Transmit Level Receiver Volume VLC Override Address T ransmit Level Test Tone Mutual Muting Page Control
LC Option SmartSeries Option
Termination PCBA
Remote Signaling Speaker Impedance
Figure 2. Suggested wire
entry locations
Figure 3. Typical installation wiring configuration
N
OTE: Station input power can be through system cable or through a separate power source cable.
See Pub. 42004-717L2 for the possible beacon, RTU activation, and speaker impedance configurations.

Front Cov er Reattachment