Application Notes
When used in GAI- Tronic s SmartS eries ca binet, this unit can p ower 40 M onitored Inp ut Modules (MI M)
or eight Monit ored Relay Modules (MRM) or 4 0 Audio Distr ibution Modules (AD M). I f MRMs a re used
in combinat ion with MIMs or ADMs, the total load r equ irement must be calculated to ensure that the
8.3A output is not exceeded.
• A line cord is att ached to t he u nit for c onnection to a standard 120 V ac duplex output. Do not change
or alter the line cord.
• The power supply module inside the chassis is equipped with an internal fuse protection which is not
accessible. Do not attempt to repair or replace the fuse—call GAI-Tronics for service.
Figure 1. Power Supply—Front View
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 800-492-1212 Fax : 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42004-282
Model F95090E 12 V dc @ 8.3 A Rack-Mount Power Supply Page:
Figure 2. Power Supply—Rear T erminations
Installation
2 of 2
WARNING
Disconnect ac power during wiring. This device can present a shock haz ard. Please use c are when
handling this device and be sure that the ac p ower is not c onnec ted during wiring.
Wiring
Depth c learance behind the mounting rails should be at least twelve to fourteen inches for wiring.
1. Run p ower c ord to t he ac power ou tlet which will power this unit , but do not connect power unt il the
entire installa tion is complete.
2. Run the dc power conduct ors from the devices requiring 12 V dc p ower, t o the output terminals as
shown in Figure 2.
Specifications
Input power ....................................................Nominal: 120 V ac; Range: 85-264, 50/60 Hz, single phase
Output power....................................................................................................12 V dc @ 8.3A maximum
Output type...............................................................................................................Switched @ 120 kHz
Efficiency ....................................................................................................76% typical @ maximum load
Controls................................................................................................ On/off toggle switch on f ront p anel
Indicators ................................................................. Red LED on front panel (illuminates when operating)
Material/Finish..............................................16 gauge cold rolled steel with gray polyurethane paint finish
Mounting....................................................................Standard 3U (5.25 inch) 19-inch EIA rack mounting
Connections .................................................................................................... Barrier-type terminal blocks
Dimensions...............................................................5.25 (133) H × 19 (483) W × 6 (152) D; inches (mm)
Temperature range................................................................................0º C to +49º C (+32º F to +120º F)
Humidity......................................................................................................... 0% to 85% non-condensing
Weight.........................................................................................................Approximately 5 lbs (2.26 kg)
\\s_eng\gtc proddoc s \ s t andard iom s - current release\42004 inst r. m anuals \ 42004-282. doc
3/98