GAI-Tronics DHS-201 User Manual

Pub. 42004-453C
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model DHS/DHF 200 Series

T ABLE OF C ONTENTS

Confidentiality Notice .....................................................................................................................1
General Information .......................................................................................................................1
Product Overview ................................................................................................................................... 1
System Requirements and Limitations ................................................................................................. 1
Features and Functions .......................................................................................................................... 2
Model Chart ............................................................................................................................................ 2
Available Models ..................................................................................................................................... 3
Wall-Mount Handset Intercoms (Indoor/Outdoor) ............................................................................................... 3
Wall-Mount Hands-free Intercoms (Indoor/Outdoor) ........................................................................................... 3
Flush-Mount Hands-free Intercoms ...................................................................................................................... 3
Description of Major Components ........................................................................................................ 4
Installation ......................................................................................................................................5
General Information ............................................................................................................................... 5
General Installation Guidelin es ............................................................................................................. 5
Security Hardware .................................................................................................................................. 5
Conduit Installation Details ................................................................................................................... 6
Mounting .................................................................................................................................................. 7
Models DHS-201, DHF-201, and DHF-202 ......................................................................................................... 7
Models DHF-203 and DHF-204 ........................................................................................................................... 8
Field Wire Installation .......................................................................................................................... 10
Power .................................................................................................................................................................. 10
System ................................................................................................................................................................. 12
Audio .................................................................................................................................................................. 12
Audio Level Adjustments ................................................................................................................................... 13
Switch Configuration .......................................................................................................................................... 16
Inputs .................................................................................................................................................................. 17
Outputs ................................................................................................................................................................ 17
Operation .......................................................................................................................................19
Hands-free Operation ........................................................................................................................... 19
Handset Operation ................................................................................................................................ 19
Headset Operation ................................................................................................................................ 20
Paging ..................................................................................................................................................... 20
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Table of Contents Pub. 42004-453C
MODEL DHS/DHF 200 SERIES DIGITAL INTERCOM STATIONS
Alarms and Music ................................................................................................................................. 20
Status Indication ................................................................................................................................... 21
Call Status ........................................................................................................................................................... 21
Controls .................................................................................................................................................. 21
Keypad ................................................................................................................................................................ 21
Single Button Dialing ......................................................................................................................................... 21
Talk/Listen Control ............................................................................................................................................. 21
Call Cancel .......................................................................................................................................................... 21
Master Volume ................................................................................................................................................... 21
Maintenance ..................................................................................................................................22
General Information ............................................................................................................................. 22
Troubleshooting .................................................................................................................................... 22
Service ................................................................................................................................................................ 23
Replacement Parts ................................................................................................................................ 23
Specifications ................................................................................................................................24
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
ii
Pub. 42004-453C
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model DHS/DHF 200 Series

Confidential ity Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI­Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

General Information

Product Overview

The GAI-Tronics DHS/DHF 200 Series Digital Intercom Stations are designed for use in hazardous and non-hazardous area communications, both indoors and outdoors, and in high noise areas.
The DHS/DHF 200 Series Intercom Stations are ideal for both large and small intercom systems. Communication and security systems can be networked to include up to 120 intercom servers with the capability to support a corresponding maximum of 5,760 stations. The systems can be upgraded to include alarms, radio interface, telephone interface, music, etc. All communication to the stations is via a two-wire digital communication line.
These intercom stations provide all-call, group call, hands-free, handset and headset communication, input/output controls, and a variety of other functions. These stations also contain integrated functions such as door and gate control, and control desk functions.
Figure 1. Digital Intercom Station
System Requirements and Limitations
As a minimum, the DHS/DHF 200 Series Stations require a system central to supply power for operation for basic functions. A local 24 V ac or dc power source is required for full functionality (external speaker, audio line driver and headset operation). Remote amplifiers can be installed with these stations to broadcast additional audio. Refer to Pub. 42004-452, “Model DSA-201 Remote Speaker Amplifier.”
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Pub. 42004-453C
ODEL DHS/DHF 200 SERIES DIGITAL INTERCOM STATIONS Page 2 of 25
M

Features and Functions

Central power (limited functionality) or
local power operation (full functionality)
Two-wire digital communication 24 V ac or dc power Footswitch input 12-watt, Class D speaker amplifier 0 dBm, 600-ohm audio line driver Volume control 16-button keypad Optional talk/listen control Configurable buttons Call status indicator Noise-canceling handsets Hands-free operation Two configurable inputs

Model Chart

Direct dial, auto-dial, group call, and all-call
capability
Suitable for high noise areas Optional footswitch Optional headset Optional noise-canceling gooseneck microphone Protection against feedback Simplex, switched duplex, and full-duplex capable Call transfer Conference calling Two configurable outputs Suitable for Div. 2 Hazardous Areas (selected models) UL Listed CE Mark
Feature Model
DHS-201
DHS­201HS
DHF-201
DHF­201HS
DHF­201GN
DHF­201HSGN
DHF-202 DHF-
202HS DHF
202GN DHF-
202HSGN DHF-203 DHF-204
Surface
Mount
Flush
Mount
UL
Div. 2
Hand-
set
Hands-
free
Single
Button
Dual
Button
Full
Keypad
Goose-
neck
Mic
Head-
set
Jack
f:\standard ioms - current release\42004 instr. manuals\42004-453c.doc 10/12
Pub. 42004-453C
ODEL DHS/DHF 200 SERIES DIGITAL INTERCOM STATIONS Page 3 of 25
M

Available Models

Wall-Mount Handset Intercoms (Indoor/Outdoor)

The Model DHS-201 Wall-mou n t Hand se t Inter com has a built-in speaker amplifier and external audio
output with an optional headset jack.

Wall-Mount Hands-free Intercoms (Indoor/Outdoor)

The wall-mount hands-free intercoms include a built-in speaker amplifier and external audio output. They are available with an optional gooseneck mic or a headset jack.
Models DHF-201 (NEC Div. 2) Single Button Wall- mount Hand s- free Interc om includes a single
programmable push button for call-in only.
Models DHF-202 (NEC Div. 2) Wall-mount Hands-free Intercom with 16-Button Keypad includes
two programmable push buttons.
Figure 2. Model DHS-201

Flush-Mount Hands-free Intercoms

The flush-mount hands-free models include a built-in speaker amplifier and external audio output, and are available with an optional gooseneck microphone.
Model DHF-203 Single Button Flush-Mount Hands-free Intercom includes a single
programmable push button for call-in only.
Model DHF-204 Flush-Mount Hands-free Intercom with 16-Button Keypad includes two
programmable push buttons.
Figure 3. Models DHF-201 and DHF-202
Figure 4. Models DHF-203 and DHF-204
f:\standard ioms - current release\42004 instr. manuals\42004-453c.doc 10/12
Pub. 42004-453C
ODEL DHS/DHF 200 SERIES DIGITAL INTERCOM STATIONS Page 4 of 25
M

Description of Major Components

The 200 Series Digital Intercom Stations are made up of a front panel assembly and a rear enclosure. The following assemblies are mounted on the interior side of the front panel:
69539-10x Audio/Interface PCB Assembly 69547-10x Intercom PCB Assembly
Refer to Figure 5 below. The front panel contains the user interface components (microphone, speaker,
status LED, keypad, and handset) in addition to the 69539-10x Audio/Interface PCBA that provides all
terminations except earth ground. This PCBA also contains controls for volume, gain, and switch configuration.
The 69547-10x Intercom PCBA connects to the Audio Interface PCBA from below to transmit/receive
audio, data, and control information to and from the central control cabinet. The rear enclosure protects the electronics from the harsh environment, and also contains the termination for earth ground.
Figure 5. Front Panel Assembly with Intercom and Audio Interface PCBAs
f:\standard ioms - current release\42004 instr. manuals\42004-453c.doc 10/12
Pub. 42004-453C
ODEL DHS/DHF 200 SERIES DIGITAL INTERCOM STATIONS Page 5 of 25
M

Installation

General Information

WARNING
D, Class II Division 2, Groups F, and G, Class III OR non-hazardous locations only. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation.
WARNING
been removed or the area is known to be non-hazardous.
WARNING
for Class I, Division 2. Averttissement – Risque d’explosion - la substitition de composants peut rendre ce matériel
inacceptable pour les em-placements de Classe 1, Division 2. Averttissement – Risque d’explosion – avant de déconnector l’equipment, couper le courant ou
s’assurer que l’emplacement est désigné non dandereux.
Install equipment without modification and according to all applicable local and national electrical codes.
USA and Canada Consult the National Electrical Code (NFPA 70), Canadian Standards Association
(CSA 22.1), and local codes for specific requirements regarding your installation. Class 2 circuit wiring must be performed in accordance with NEC 725.55.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and
EXPLOSION HAZARD – Do not disconnect equipment unless power has
EXPLOSION HAZARD - Substitution of components may impair suitability

General Installation Guidelines

This station contains a high gain amplifier, which enables operation in high noise environments. To prevent feedback problems in the system, the ambient noise levels, volume settings, and station placement must be taken into consideration. Unpleasant feedback problems can be reduced by taking the following measures:
Pointing the speaker away from nearby Intercom Stations Placing the speakers in separate rooms from Intercom Stations Reducing volume levels

Security Hardware

The stations in the manual are vandal resistant. The front panel is attached to its enclosure with security screws. A GAI-Tronics Model 233-001 Security Screwdriver or Torx T-25 security head tip (sold separately) is required for installing or removing the front panel.
f:\standard ioms - current release\42004 instr. manuals\42004-453c.doc 10/12
Pub. 42004-453C
ODEL DHS/DHF 200 SERIES DIGITAL INTERCOM STATIONS Page 6 of 25
M

Conduit Installation Details

GAI-Tronics recommends installing wiring in conduit to protect against accidental damage and vandalism. To prevent moisture from entering the enclosure, we strongly recommend the following:
Conduit should enter the enclosure from the bottom. If entered from the top, the conduit must
be internally sealed to prevent moisture ingress.
Sealed fittings should be installed at all cable entry points. Silicone sealant or equivalent should be applied around and inside all conduit entries.
Figure 6. Bottom entry conduit installation details
for metallic enclosures
Figure 7. Top entry conduit installation details for
metallic enclosures (NOT recommended)
f:\standard ioms - current release\42004 instr. manuals\42004-453c.doc 10/12
Pub. 42004-453C
ODEL DHS/DHF 200 SERIES DIGITAL INTERCOM STATIONS Page 7 of 25
M

Mounting

Models DHS-201, DHF-201, and DHF-202

The mounting and wiring instructions for the model listed above are as follows:
1. Remove the four security screws from the front of
the intercom station, and separate the front panel from the rear enclosure. Place the front panel and screws in a safe location.
2. Secure the rear enclosure to the mounting surface
using the four 0.28-inch (7.11-mm) mounting holes provided along with four ¼-inch (M6) diameter bolts of the appropriate length for the mounting surface.
3. Install the field wiring according to the
instructions provided on page 10.
Figure 8. Model DHF-202
Figure 9. Model DHS-201
4. Using the appropriate section of this manual,
make the necessary set-up changes:
Adjust the audio levels as described in the
“Audio Level Adjustments” section beginning on page 13.
Make any necessary hardware configuration
changes as described in the “Switch Configuration” section on page 16.
Refer to page 17 for the initial programming
options.
5. Complete the installation by reattaching the front
panel assembly to the rear enclosure using the four security screws. Use a torque setting of 30 in-lbs. or 35 cm-kg.
6. Verify that the unit is operating as described in the
“Operation” section beginning on page 19.
OTE: When using the GAI-Tronics Model 231-001
N
Pole Mounting Kit, follow the mounting instructions provided in the kit.
f:\standard ioms - current release\42004 instr. manuals\42004-453c.doc 10/12