Furuno FELCOM 16 USCG, FELCOM 15 USCG Operator's Manual

Page 1
OPERATOR'S MANUAL
SHIP SECURITY
ALERT SYSTEM (SSAS)
USCG Version
MODEL
IC-307
www.furuno.co.jp
Page 2
9‑52Ashihara‑cho,
Fax:
A:AUG
2005
.
A1:JUN.06,2008
Pub.No.
OME‑56352‑A1
*
00015716000
**00015716000
*
(
DAMI
)
IC‑307(USCGVersion)
*
00015716000
**00015716000
*
Nishinomiya,662‑8580,JAPAN
Telephone: +81‑(0)798‑65‑2111
+81‑(0)798‑65‑4200
Thepaperusedinthismanual iselementalchlorinefree.
・FURUNOAuthorizedDistributor/Dealer
Allrightsreserved.
PrintedinJapan
*00015716000*
Page 3

TABLE OF CONTENTS

SYSTEM CONFIGURATION.........................................................................................2
1.
OVERVIEW OF SSAS..............................................................................................3
2. INSTALLATION.........................................................................................................5
2.1 Mounting.........................................................................................................................5
2.1.1 Junction box (for FELCOM 16)...............................................................................5
2.1.2 SSAS aler t u ni t.......................................................................................................6
2.2 Wiring..................................................................................................................... .........8
2.2.1 Junction box (for FELCOM 16)...............................................................................8
2.2.2 SSAS aler t u ni t.......................................................................................................9
2.3 Enabling USCG Version................................................................................................10
3. OPERATION............................................................................................................11
3.1 Operation Mode............................................................................................................ 11
3.1.1 Changing the password........................................................................................ 11
3.1.2 SSAS man ager mode...........................................................................................12
3.2 Setting SSAS Report Destination and Message Contents.............................................13
3.3 Tr a nsmi ttin g SS AS R ep ort............................................................................................16
3.4 Testi ng the Button.........................................................................................................17
3.5 SSAS Report Test.........................................................................................................21
OUTLINE DRAWINGS...............................................................................................D-1
INTERCONNECTION DIAGRAMS...........................................................................S-1
1
Page 4

SYSTEM CONFIGURATION

Regulations require at least two SSAS alert units.
FELCOM 15
ANTENNA
UNIT
IC-115
DGPS
100-115/200-230 VA C 1φ, 50/60 Hz
24 VDC
12-24 VDC
24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
FELCOM 16
AC-DC Power Supply
PR-240-CE*1
Printer PP-510
Mini Keyboard
SSAS Alert Unit
IC-307
(Max. 3 units)
TERMINAL UNIT
IC-215
GPS receiver
OP16-24
JUNCTION
BOX
IC-315
*1 Any AC-DC power supply fulfilling requirements of IEC 60945 may be used.
ANTENNA
UNIT
IC-116
EGC Printer
PP-505
Personal
Computer
(PC/AT compatible)
Shipboard LAN (Ethernet)
Distress Alert/
Received Call Unit
IC-305
Alarm Unit
IC-306
Navigator
: Standard Supply : Option : Local Supply
24 VDC
Printer
100-115/200-230 VA C 1φ, 50/60 Hz
24 VDC
12-24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
AC-DC Power Supply PR-240-CE*1
IC-307
INMARSAT MINI-C MOBILE EARTH STATION
FURUNO
POWER
I
O
SSAS Alert Unit
IC-307
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
LOGIN
POWER
TX
ERROR
PERSONAL
COMPUTER
(PC/AT compatible)
JUNCTION BOX
IC-315
PRINTER
: Standard : Option : Local Supply
(Max. 3 units)
2
Page 5

1. OVERVIEW OF SSAS

The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES FELCOM 15 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting specified addresses (for example, your ship’s company) that your ship is under attack by intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01 July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized personnel. No audible or visible alarm is generated while the SSAS report is being transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by other than the ship’s captain or authorized personnel.
Inmarsat System
Ship Name, MMSI No., Ship Position, etc.
USCG station
3
Page 6
SSAS operation flow
1.
Open the cover and press button one second.
SSAS report is immediately transmitted.
2.
An LES sends acknowledgement to your ship.
3.
SSAS report is automatically sent to multiple addresses if applicable.
4.
Repeated transmission of the SSAS report begins. The interval at which to transmit the SSAS report to each address can be specifed. The SSAS report is continuously transmitted at the interval selected.
5.
To cancel repeated transmission:
Terminal unit: Turn off the communication unit. Press and hold down the button on the SSAS unit while turning on the communication unit. Release the button when the test mode starts. (The FELCOM 16 goes into the button test mode.) Note that if there are any unsent messages they are sent and then the system goes into normal operation; namely, the test mode is not activated.
PC: Open the SSAS manager (see page 12) and input the command TERMINATE SSAS ALERT.
4
Page 7

2. INSTALLATION

2.1 Mounting

2.1.1 Junction box (for FELCOM 16)
The juncti on box IC-315 is required when installing the SSAS on the FELCOM 16; it is already installed on the FELCOM 15.
Separate t he junction box from a magnetic com pass by the distances shown bel ow to prevent deviation to a magnetic compass.
Standard compass : 1.0 m St eer ing compass: 0.7 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the m ounting location with four self-tapping screws (4x 16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
±
0.5
70
The junc tion box is connected to the connector ( at the of the
communication unit.
communi c at ion unit). Therefore, locat e t he junction box wit hin two meters
120 ±0.5
Junction box IC-315
communi c at ion unit with a 2 meter cable, with D-sub
5
Page 8
2.1.2 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent deviati on to a magnetic compas s.
Standard compass : 0.70 m St eer ing compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location shoul d be known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove f our s cr ews from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (suppli ed) .
3. The cable can be lead in from the bottom or the rear p anel. For rear panel entrance, change the clamp orientation as follow s :
a) Unfasten three screws to remove the cable clamp. b) Turn the clamp 90 degrees. c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Clamp
Rotate
Fasten three screws.
4. Run the cable thru one of the c able entrances and connect it to terminal board.
6
Page 9
5. Attach the swit c h c over as shown below. Note that t he c over may also be rotated 180 degrees.
Switch cover
Flush mounting
The optional flush mount ki t OP16-28 (Code No. 004- 448-010) is required.
Fixture 16-018-7201-1 100-317-931 1 Pan head screw M3x6 000-800-362 4 Self-tapping screw 4x16 000-802-080 4
Name Type Code No. Qty Remarks
1. Cut out the mounting position referring to the outline draw ings at the back of this
manual.
2. Fix the unit to the fix ture with four pan head s cr ews (suppli ed) .
3. Fasten the fixture with the unit to the mount ing location wi th four self-tapping screws (supplied).
4. Attach switch c over as shown above.
7
Page 10

2.2 Wiring

2.2.1 Junction box (for FELCOM 16)
Use the juncti on box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten four screws to remove the cover to connect cables to terminal board. For detailed wiring informat ion see the interconn ec tion diagram.
For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equi valent , see next page for sectional view of t his cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV -SB-C 0.2x5P cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the juncti on box . For connecting the communicati on unit IC-216, us e cable 16S0344.
Vcc
1
GND
2
TD/RD-A
Communication Unit
Cable clamp
Terminal board
Cover
Cable clamp (top)
Cable clamp (bottom)
3
TD/RD-B
4
NC
5
TD-A(NAV)
6
TD-B(NAV)
7
RD-A(NAV)
8
RD-B(NAV)
9
GND
10
DMC OUT-H
11
DMC OUT-C
12
DMC IN-H
13
DMC IN-C
14
DMC CTR
15
IC-305/306
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
1
2
3
Core 7 mm
16S0344
Fold back braided shield onto sheath and fix by cable clamp.
90mm15mm 7mm
Junction box IC-315
3. Insert cable core to 3 .
Note 1: Do not insert the cable too deeply, to prevent pinching the sheath.
Note 2: Pull each cable slightly to con­firm that they are in their holes securely.
8
Page 11
2.2.2 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the interconnect ion diagram at t he bac k of this manual. For the terminal unit (FELCOM 15) and the communicati on unit (FELCOM 16), the wiring of the SSAS is monitored and if in error “TROUBLE: SSAS UNI T connection abnormal ity .” is displayed. Further the ERROR lamp (FELCOM 16) flashes.
Junction
Box
IC-307
(No.1)
IC-307 (No. 2)
IC-307 (No. 3)
Connect wiring to the terminal board 16P0229 inside the SSAS alert unit. To differentiate between units in case of multiple unit installation, change jumper block set tings as shown below, in accordance with how many units are installed.
Jumper settings for two IC-307
Unit
Jumper
JP1 JP2
No. 1 unit: Unit with two cables connnected to it. No. 2 unit: Unit with one cable connnected to it.
Two IC-307: No. 2 unit
Three IC-307: No. 3 unit
16P0229
JP1
12345
No.1 unit* No. 2 unit
No Yes
JP2
Yes
No
Three IC-307: No. 1 and No. 2 units
6
*: Default setting
Two IC-307: No. 1 unit
16P0229
Jumper settings for three IC-307
Unit
Jumper
JP1 JP2
No. 1 and No. 2 units: Units with two cables connnected to them. No. 3 unit: Unit with one cable connnected to it.
JP2
JP1
12345
No.1 unit*
No Yes
6
No. 2 unit*
No Yes
No. 3 unit
Yes
No
Clamp for cable CO-SPEVV-SB-C
0.2x5P
Clamp for cable TTYCS-4 or equivalent
IC-307
IC-307
Cable Fabrication
Twist shield.
CO-SPEVV-SB-C 0.2X5P or TTYCS-4
Cut and tape unused wires to prevent short.
f = 16.3
mm
Conductor
Sectional view of cable TTYCS-4
Wiring inside the SSAS alert unit
9
15 mm 40 mm 10 mm
Armor
Sheath
Shield
S = 0.75 mm φ = 1.11 mm
2
Page 12

2.3 Enabling USCG Version

1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16: Press [F8], [1] to show the System Setup menu.
2. Press [] to choose Command Window and then press the [Ent er ] key.
Command Window
RFCONCPU *** [ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
3. Type “furunoservice” ( without quot ation marks) in the Ent er J O B No. field and then press
the [Enter] key. The prompt PAS SWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [ E nt er] key. Then,
the item M ain Menu is display ed in reverse video.
5. Press [1], [Enter], [1], [Enter]. O ne of the following wi ndows appears.
[ DMC ]
1. SSAS(IC-307)
2. DMC
3. OFF 4: SSAS(Momentary SW) E: Exit Enter No.:
FELCOM 15
[ SSAS ]
1. ON(IC-307)
2. OFF 3: Momentary SW (for USCG) E: Exit Enter No.:
FELCOM 16
6. Press [4] (FELCOM 15) or [3] (FELCOM 16) to enable the USCG v ers ion.
7. Press the [Esc] key several times to clos e the menu.
10
Page 13

3. OPERATION

3.1 Operation Mode

There are two menu operating m odes :
Normal mode: Menus other than SSAS-related menus are displayed. SSAS manager mode: The mode is activated by t he password entered by the ship’s
captain or aut horized personnel. The indication “SSAS Manager Mode” is s hown at the top of the scr een when this mode is activated, and it is flashing. All SSAS-related menus are available. Transmission of the SSAS report may be cancelled in this mode. The equipm ent starts up in the normal mode, regar dless of the mode in use when the power i s tur ned off.
3.1.1 Changing the password
The default password is “ship security alert”. Ship’s captain or authorized personnel m ay change the p as s word as follows:
1. FELCOM 15: Press [F8], [2] to show the System Setup m enu. FELCOM 16: Press [F8], [1] to show the Sys tem Setup menu.
2. Press [] to choose Command Window and then press the [Ent er ] key.
Command Window
RFCONCPU *** [ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
3. On the Enter JOB No. field, type “ssas password” (without quotat ion marks) and then press the [Ent er ] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW PASSWORD appears.
5. Enter new pas sword, using at least six characters, and then press the [Ent er ] key. The prompt RETYPE NEW PASSWORD app ear s .
Note: I f less than six characters ar e entered, the mes s age “Please use a longer
password.” appears. Enter a longer password.
6. Enter new pas sword again and then pres s the [Enter] key. The message “Password changed” appears.
7. Press the [Esc] key several times to close the menu.
Note: The SSAS manager mode cannot be acc essed without the correct password.
11
Page 14
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the f ollowing to access this mode.
1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16: Press [F8], [1] to show the System Setup menu.
2. Press [] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU *** [ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
3. On the Ent er JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
Note: If there is no SSAS equipment connected, t he m essage "Command Ignored: No SSAS button is installed." appears.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode is activated, and it is flashing.
CAUTION 04-04-20 05:37 (UTC) SSAS Manager Mode enabled.
<Press ESC key to continue>
5. Press the [Esc] key several times to close the menu. This enables the SSAS manager mode, which allows you to execute the proced ure in paragraph 3.2.
Note: Turn the power off and on again whenever changing SSAS-related settings.
12
Page 15

3.2 Setting SSAS Report Destination and Message Contents

When the SSAS is acti vated, t he SSAS report is sent according to the addresses (max. 5) and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu.
Note 1: The dest ination and message c ontent of an SSAS repor t vary according to
Adminis tration. T her ef or e, set them as requested by ship’s authorities. For informat ion other than ship’s name, MM SI no. and IMN no., set it manually with “Other Inf.”
Note 2: The equi pment must be in the SSAS manager mode to exec ute this procedure.
See paragr aph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports
1. Data Report
2. Message Report
3. Data Network ID
4. SSAS Report
2. Press the [4] key to shown the SSAS Report menu.
SSAS Report
1. SSAS Report 1
2. SSAS Report 2
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
6. Message Contents
3. Press [1], [2], [3] , [4] or [5] key as appropri ate and then window below appears.
SSAS Report
Status
Mode Station Name
Destination Type Prefix Code Country/Ocean Code Station ID Modem Type Address
Subject LES ID Report Interval
ON Real+Test
TELEX
02:00 (hh: mm)
13
Page 16
4. Press the [] key to choos e Mode and then press the [Enter] key.
Real+Test
Real Only Test Only
5. Press the [↑] or [↓] key to choose mode des ired and then press the [Enter] key. “Mode” defines what SSAS report(s) a stati on is to receive:
Real+Test: Actual SSAS report and test SSAS report. Real Only: Actual SSAS report only. T est Only: Test SSAS report only.
6. Press the [] key to choos e Station Name and then press the [Enter] k ey.
7. Press the [↑] or [↓] key to choose appropriate station and then press the [ E nter] key.
You may sort the list by group name, station name or communic ation type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or descending or der. Station name: Each press of [Ctrl] + [ N] s orts the list by station name, in ascendi ng or descending or der. Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in ascending or des cending order.
8. Press the [] key to choos e LE S ID and then press t he [Enter] key.
9. Press the [↑] or [↓] key to choose LES a nd then press the [Ent er ] key. Note: Cha nge the LES whenev er sea area has changed. However, the equipment
automatic ally searches for an LES with which you can c om municate and t he SSAS report is transmi t ted to that LES.
10. Press the [] key to choose Report Interval and then press the [Enter] key.
11. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
12. Press the [Esc] key to open the Update window .
SSAS Report
Status Mode Station Name
Destination Type Prefix Code Country/Ocean Code Station ID Modem Type Address Subject
LES ID
Report Interval
ON Real+Test
TELEX
02:00 (hh: mm)
Yes
Update
No
13. Yes is selected; press the [Enter] key to close the SSAS report wi ndow.
14
Page 17
14. Press the [6] key to display t he SSAS Message Cont ents menu.
SSAS Message Contents
Vessel Name :
MMSI : IMN : Other Inf. :
LAT: LON: Time: COURSE: SPEED: Time:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34: 44. 46N 135: 21. 26E 02/04/2004 04:31:48 (UTC) 071 deg 00 kt 02/04/2004 04:31:48 (UTC)
SSAS report window (F ELCOM 15/16)
15. Press the [Enter ] key to open the Vessel Name window.
16. Enter vessel’s name and then press the [Enter] key.
17. Press the [] key to choose MMSI and t hen press the [Enter] k ey.
18. Enter MMSI num ber and then press the [Ent er ] k ey.
19. Press the [] key to choose IMN and then press the [Enter] key.
20. Enter IMN and t hen pr es s t he [Enter] key.
21. Press the [] key to choose Other I nf. and then press the [Enter] key
22. Enter appropri ate message (thre e lines) and then pres s the [Enter] key. Note: To shift between lines, use the [↑] or [] key.
23. Press the [Esc] key to open the Update window.
24. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
25.Press the [ E s c ] key twice to ret ur n t o the standby display.
Note 1: To delete entered subscr iber’s data, choose “Remove” f r om “ Status .” Note 2: SSAS report setti ngs may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window . FELCOM 16: [F8], [8], [6] to show the Save/Load window .
Save to FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
Load from FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
*: Availlable only in SSAS manager mode
("5.SSAS Report" is added in the SSAS manager mode and item numbers are shifted.)
Note 3: To confirm the sett ings, follow par agr aph 3.5.
15
Page 18

3.3 Transmitting SSAS Report

The SSAS report i s sent one second after the but t on on the SSAS is pressed. Repeate d transmiss ion can only be stopped from the SSAS m anager mode.
1. Open the cover of the SSAS alert button.
Cover
2. Push the button one second. The but ton is a momentary switch, meaning it is activated as soon as it is pressed one second.
3. The SSAS report is transmitted after the button is pushe d one second. Below are the contents of t he SSAS report.
- - -
SSAS ALERT MESSAGE Vessel Name: Queen Elizabeth 2 MMSI: 111660000 IMN: 443100000 Help me! LAT: 34:44.46N LON: 135:21.26E Time: 02/04/2004 04:31:48 (UTC) COURSE: 071 deg SPEED: 00 kt Time: 02/04/2004 04:31:48 (UTC)
- - -
Ship's Name MMSI No. IMN No. Desired message Own ship postion in latitude Own ship position in longitude Time of position data Course Speed Time of course and speed data
4. An LES sends acknowledgement to y our s hip.
5. For multiple dest inations, steps 3 and 4 are automatically repeated (it is not necessary to push the button again).
Cancelling repeated trans mi ssion T erminal Unit: Turn off the communicat ion unit. Press and hold down the butt on on the
SSAS unit while turning on the communication u nit. Release the button when the test mode starts. (The FELCOM 16 goes into the button test mode.) Note that if there are any unsent messages t hey are sent and then t he system goes into nor m al operation; nam ely, the test mode is not act ivated.
PC: Open the SSAS manager (see p age 12) and input the command TERMINATE SSAS ALERT.
16
Page 19

3.4 Testing the Button

The SSAS buttons can be tested as below .
Note 1: An actual SSAS report cannot be transmitt ed during the testing. Note 2: The equipment must be in t he SSAS manager mode to conduct the test .
FELCOM 15
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ( [6] key when the FELCOM functions as an EGC rec eiver) to displ ay the Test menu.
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test
3. Press the [4] key.
Test
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Yes
Start
No
4. Press the [Enter] k ey to start the test.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
Distress/SSAS buttons are under test mode.
3. Self Test
5. Ocean Region
INF: Distress/SSAS Buttons entered into TEST MODE.
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Press any key to escape.
<Press ESC key to continue>
CAUTION
The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT w orks
correctly.” appears if the unit is functioni ng pr operly.
7. Five seconds after pressing t he button the SSAS test report is aut omatically sent to stati on whose Mode set on the SSAS Report w indow is “Real+Test” or “Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appro priate button.
17
Page 20
8. To escape from the test, press t he [Esc] key twice on the terminal unit . The test mode is stopped and the message shown below appears t o notify you that norm al operation has been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
9. Press the [Esc] key three times to return to the standby display.
18
Page 21
FELCOM 16, no PC
Turn off communication unit.
Press button of No.1 SSAS while turning on communication unit. Continue pressing button.
30 s
When POWER, LOGIN and TX lamps flash, release button.
Press and hold down button of No.1 SSAS.
POWER, LOGIN and TX lamps flash and then go off.
Send SSAS
test report?
Yes (TX starts after button is pressed and held 5 s.)
SSAS report is sent to station(s) whose mode is "Real+Test" or "Test Only". (See paragraph 3.2.) Lamps flash rapidly during TX.
Test
successful?
Yes
POWER, LOGIN and TX lamps flash in that order.
Release button of No.1 SSAS.
POWER, LOGIN and TX lamps flash in that order and go off.
No
ERROR lamp flashes rapidly.
No
T est TX
Press and hold down button of No.2 SSAS.
Same procedure as No.1 SSAS.
Release button of No.2 SSAS.
Turn communication unit off and on again.
Note: If a 3rd SSAS unit is
installed test it by procedure used to test No.2
19
Page 22
FELCOM 16, PC version
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ( [6] key when the FELCOM functions as an EGC rec eiver) to displ ay the Test menu.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test
3. Press the [4] key.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Test
SSAS Button Test
Yes
Start
No
4. Press the [Enter] k ey to start the test.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
Distress/SSAS buttons are under test mode.
3. Self Test
5. Ocean Region
INF: Distress/SSAS Buttons entered into TEST MODE.
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Press any key to escape.
CAUTION
<Press ESC key to continue>
The display shows the message (in red) “SSAS buttons are u nder test. Cancel the test mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT works correctly.” appears if the unit is functioni ng pr operly.
7. Five seconds after the button is pushed the SSAS test report is automatically sent to the stati on(s) whose Mode set on the SSAS Report w indow is “Real+Test” or Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appro priate button.
8. To escape from the test, press t he [Esc] key twice on the terminal unit . The test mode is stopped and the message shown below appears t o notify you that norm al operation has been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
9. Press the [Esc] key three times to return to the standby display.
20
Page 23

3.5 SSAS Report Test

You can test for successful transmission of the SSAS report to the address you specify, without using the button. The test report m essage states “!!! Test Call !!!” to alert the receiver of the message that i t is a test call.
Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then f ollow this procedur e.
1. Press the [F5] key to open the Reports menu.
2. Press the [4] key to choose the SSAS Report m enu.
3. Press the [1], [2], [3], [4] or [5] key as appropriat e, and the SSAS report setting menu appears.
4. Set destination w her e to transmit the test.
5. Press the [] key to choose Status and then press the [ E nter] key.
6. Press the [] key to choose TEST and then pr ess the [Ent er ] key.
7. Press the [Esc] key to open the Update window.
8. Yes is selected; press the [Enter] key. The test report is transmitt ed. Af ter it is transmit ted, “Status” is automatically set to O N.
9. Press the [Esc] key twice to return to the s tandby display.
21
Page 24
D-1
Apr.17'07R.Esumi
Page 25
Y.Hatai
D-2
Page 26
Mar.03'05
D-3
Page 27
アンテナユニット
S-1
ANTENNA UNIT IC-115
RW-4747
0.3m TPA5FB0.3NJ5
FBA-5DFB,0.3m
A
船内LAN (HUB) パソコンなど LAN(HUB) OR PC, ETC.
B
VCTF-0.75x3C,5m,φ7
24 VDC
C
100-115/ 200-230 VAC
(16S0084)
12-24 VDC
DPYC-2.5
1φ,50/60Hz
24 VDC
DPYC-4
注記
*1)造船所手配。 *2)オプション。
D
*3)工場にて取付済み。 *4)コネクタクランプでアースに落とす。 *5)TB基板(16P0116)が必要。 *6)終端のIC-307はジャンパー設定を変更する。
*7)アンテナケーブルは切断して使用しないこと。
RH12BPG-3S
*1
*1
+
-
ケーブル/コネクタは選択 SELECT CABLE & CONNECTOR
12D-SFA-CV,100m,φ20: N-P-12DSFA 8D-FB-CV,50m,φ14.3: N-P-8DFB
*7
TP5FBAW-5DFBB,30m,φ10.7
キーボード KEYBOARD BTC-5100C PS/2
REDアカ BLKクロ WHTシロ
AC/DC
AC IN
電源ユニット
+24V
2
0V
3
GND
MJ-A3SPF0018-050ZC,5m,φ11
24VDC
OUT
24VDC
1
AC/DC POWER SUPPLY UNIT
DC IN
PR-240
*2
PE IV-2sq. 保護アース
STP CABLE(CAT5) *1 PC: CROSS CABLE
HUB: STRAIGHT CABLE
プリンタ PRINTER PP-510
+
-
*1
1
*2
36
57-3036
*4
FUSE 15A(12V) 7A(24V)
*3
16S0184,3m,φ8
シロ クロ
RJ-45
P
P
17JE-23250
-02(D8C)
*4
*3
MJ-A3SPF
WHT BLK
ターミナルユニット TERMINAL UNIT
TNCP-NJ
IC-215
ANT
2B02
16P0208A
KEYBOARD
1
KDAT
2
NC
3
GND
4
+5V
5
KCLK
6
NC
LAN
1
E_TD_P
2
E_TD-N
3
E_RD_P
4
NC
5
NC
6
E_RD_N
7
NC
8
NC
*3
PRINTER
1
25
2B03 16P0209
12-24VDC
1
DC(+)
2
DC(-)
3
GND
2B10 16P0214
銅板 COPPER STRAP W=30,1.2m
JUNCTION
Vcc(ALM)
GND TD/RD-A TD/RD-B
TD-A TD-B RD-A RD-B
GND
DMC_OUT-H DMC_OUT-C DMC_CHECK
DMC_IN-C DMC_CTRL
RXD
TXD
GND
DGPS
BNC PLAG
D-sub15P
1 2 3 4 5
NC
6 7 8
9 10 11 12 13 14 15
17JE-13090 17JE-23090
-02(D8C)
DTE
1
2
3
4
5
6
7
8
9
COAX. CABLE(50Ω)
*3
17JE-573-10,5m,φ8 CO-0.2x5P,MAX.15m
*4
17JE-13090
DTE
-02(D8C) 1 2
RXD
3
TXD
4 5
GND
6 7 8
9
2m
*2
CO-0.2x2P,MAX.15m
*4
*1
*2
DGPSデコーダー DGPS DECODER
接続箱 JUNCTION BOX IC-315
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
-02(D8C) 1
2 3 4 5 6 7 8 9
*4
FM14-7P
*4
FM14-5P
*4
TTYCS-4
TTYCS-1(*1) OR CO-0.2x2P(*2)
TTYCS-4(*1) OR CO-0.2x5P(*2)
パソコン
PC
NC RXD TXD DTR GND DSR RTS CTS NC
1
RXD
2
TXD
3
0V
7
NC
1
RXD
2
TXD
3
NC
4
NC
5
0V
I/F BOX OP16-14
*1
または OR
JUNCTION BOX
EGCプリンタ EGC PRINTER PP-505
(+)
*2
(-)
FM14-7P
1 2 3 4 5
*2
6 7
航法装置 NAV EQUIPMENT
P
P
IC-315接続箱
11 12 13 14 15
08S0157,3m
1 2
GND 08S0087
*2
CO-0.2x5P,MAX.100m
*4
アラームユニット ALARM UNIT
16P0213B
1
VCC
P
2
GND
3
TD/RD-A
P
4
TD/RD-B
5
FG
遭難警報器 DISTRESS ALERT/ RECEIVED CALL UNIT
16P0213A
1
VCC
P
2
GND
3
TD/RD-A
P
4
TD/RD-B
5
FG
保安警報発呼器 SSAS ALERT UNIT IC-307 (No.1)
1
SSAS_OUT-H
2
NC
3
SSAS_CHECK
4
SSAS_IN-C
5
SSAS_CTRL
6
GND
TTYCS-4(*1) OR CO-0.2x5P(*2)
*1
TTYCS-4
24VDC
FM14-7P
P
P
*4
P
P
1 2 3 4 5 6 7
IC-306
IC-305
*2 *6
TB5
1
DIST_IN-H
2
DIST_IN-C
3
DIST_OUT-H
4
DIST_OUT-C
5
DIST_CTR
6
GND
RXD-H TXD-H FG TXD-C RXD-C +9V NC
EGCプリンタ EGC PRINTER PP-505
654321
保安警報発呼器 SSAS ALERT UNIT IC-307 (No.2)
P P
PP
合計 :最大200m TOTAL: UP TO 200m
遭難警報装置 DISTRESS MESSAGE CONTROLLER
*2 *5
(+) (-)
DMC-5
1 2
*2 *6
1 2 3 4 5 6
08S0157,3m
GND 08S0087
保安警報発呼器 SSAS ALERT UNIT IC-307 (No.3)
1 2 3 4 5 6
最大3台まで接続可能。 MAX.3 SETS AVAILABLE.
24VDC
*2 *6
NOTE
*1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. *4. GROUND THRU CONNECTOR CLAMP. *5. TB BOARD (16P0116) REQUIRED. *6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*7. DO NOT SHORTEN ANTENNA CABLE.
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
DRAWN
CHECKED
APPROVED
SCALE
DWG No.
Aug. 24 '07
Aug. 24 '07
T.YAMASAKI
T.TAKENO
Aug.27'07R.Esumi
MASS
C5635-C01- M
TITLE
名称
FELCOM 15
インマルサットC船舶地球局
相互結線図
kg
NAME
INMARSAT-C MES
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
Page 28
*2 *5
S-2
12345
SSAS ALERT UNIT
保安警報発呼器
IC-307 (No.3)
*4 *5
12345
SSAS ALERT UNIT
保安警報発呼器
IC-307 (No.2)
43
*4
SSAS_OUT-H
NC
12345
IC-307 (No.1)
SSAS ALERT UNIT
保安警報発呼器
RXD
TXDNCDTR
DSR
CTS
RTS
パソコン
PC
123456789
-02(D8C)-02(D8C)
17JE-23090
*2
17JE-573-10,5m,φ8
*3 *3
GND
NC
*4
IC-315
接続箱
JUNCTION BOX
*3
Vcc
123
2m
GND
TD/RD-A
TD/RD-BNCTD-A
TD-B
45678
RD-A
RD-B 9
DMC_OUT-H
DMC_OUT-C
GND
1011121314
P
P
P
P
SSAS_IN-C
SSAS_CHECK
P
P
DMC_IN-C
DMC_IN-H
6
最大3台まで接続可能
6
SSAS_CTRL
GND
6
DMC_CTR
15
MAX. 3 UNITS AVAILABLE
合計:最大200m
TOTAL: UP TO 200m
TTYCS-4(*1) OR CO-0.2x5P(*2)
FELCOM 16
インマルサットMINI-C携帯移動地球局
相互結線図
INMARSAT MINI-C MES
名称
TITLE
NAME
INTERCONNECTION DIAGRAM
kg
17JE-13090
231
45678
DTE
RXD
TXD
GND
2
IC-216
通信制御ユニット
COMMUNICATION UNIT
TNCP-NJ
ケーブル/コネクタは選択
8D-FB-CV,50m,φ14.3: N-P-8DFB
12D-SFA-CV,100m,φ20: N-P-12DSFA
SELECT CABLE & CONNECTOR
1
*6
ANT
TP58A15W-RG58,15m,φ5
TP5FBAW-5DFBB,30m,φ10.7
9
2B02 16P0208B
D-sub15P
SSAS
12-24VDC
*3
FM-C3FP
FUSE
10A:12VDC
123
GND
TX/RX-A
Vcc(6.5V)
DC(-)
DC(+)
123
BLKクロ
アカ RED
5A:24VDC
FM-C3FPS-002,3.5m,φ7.5
45678
NCNCNCNCNCNCNC
TX/RX-B
GND
16P0227
2B10
9
+
-
OUT
24VDC
AC/DC*2電源ユニット
ACINDC
*1
*1
DPYC-2.5
1011121314
SSAS_OUT-H
SSAS_CHECK
*1
PE
SUPPLY UNIT
AC/DC POWER
PR-240
IN
+
-
DPYC-4
15
SSAS_IN-C
SSAS_CTRL
IV-2sq.
保護アース
銅板 COPPER STRAP
W=30,1.2m
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
T.YAMASAKI
Apr. 24 '07
DRAWN
CHECKED
MASS
T.TAKENO
SCALE
C5638-C01- K
DWG No.
May.9'07R.Esumi
Apr. 24 '07
APPROVED
TPA5FB0.3NJ5
FBA-5DFB,0.3m
ANTENNA UNIT
アンテナユニット
IC-116
RW-4747
0.3m
12-24 VDC
100-115/
A
1φ,50/60Hz
200-230 VAC
B
24 VDC
注記
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)SSAS仕様時標準支給。
*5)終端のIC-307はジャンパー設定を変更する。
*6)アンテナケーブルは切断して使用しないこと。
C
NOTE
*2. OPTION.
*1. SHIPYARD SUPPLY.
*3. FITTED AT FACTORY.
*4. STANDARD SUPPLY FOR SSAS SPEC.
*6. DO NOT SHORTEN ANTENNA CABLE.
*5. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
Loading...