Regulations require at least two SSAS alert units.
FELCOM 15
ANTENNA
UNIT
IC-115
DGPS
100-115/200-230 VA C
1φ, 50/60 Hz
24 VDC
12-24 VDC
24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
FELCOM 16
AC-DC Power Supply
PR-240-CE*1
Printer
PP-510
Mini Keyboard
SSAS Alert Unit
IC-307
(Max. 3 units)
TERMINAL UNIT
IC-215
GPS receiver
OP16-24
JUNCTION
BOX
IC-315
*1 Any AC-DC power supply
fulfilling requirements of
IEC 60945 may be used.
ANTENNA
UNIT
IC-116
EGC Printer
PP-505
Personal
Computer
(PC/AT compatible)
Shipboard LAN (Ethernet)
Distress Alert/
Received Call Unit
IC-305
Alarm Unit
IC-306
Navigator
: Standard Supply
: Option
: Local Supply
24 VDC
Printer
100-115/200-230 VA C
1φ, 50/60 Hz
24 VDC
12-24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
AC-DC
Power Supply
PR-240-CE*1
IC-307
INMARSAT MINI-C MOBILE EARTH STATION
FURUNO
POWER
I
O
SSAS Alert Unit
IC-307
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
LOGIN
POWER
TX
ERROR
PERSONAL
COMPUTER
(PC/AT compatible)
JUNCTION BOX
IC-315
PRINTER
: Standard
: Option
: Local Supply
(Max. 3 units)
2
Page 5
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting specified
addresses (for example, your ship’s company) that your ship is under attack by intruders.
The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01
July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by
other than the ship’s captain or authorized personnel.
Inmarsat System
Ship Name, MMSI No.,
Ship Position, etc.
USCG station
3
Page 6
SSAS operation flow
1.
Open the cover and press button one second.
SSAS report is immediately transmitted.
↓
2.
An LES sends acknowledgement to your ship.
3.
SSAS report is automatically sent to multiple addresses if applicable.
↓
4.
Repeated transmission of the SSAS report begins. The interval at
which to transmit the SSAS report to each address can be specifed.
The SSAS report is continuously transmitted at the interval selected.
↓
5.
To cancel repeated transmission:
Terminal unit: Turn off the communication unit. Press and hold down
the button on the SSAS unit while turning on the communication unit.
Release the button when the test mode starts. (The FELCOM 16 goes
into the button test mode.)
Note that if there are any unsent messages they are sent and then the
system goes into normal operation; namely, the test mode is not
activated.
PC: Open the SSAS manager (see page 12) and input the command
TERMINATE SSAS ALERT.
4
Page 7
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16)
The juncti on box IC-315 is required when installing the SSAS on the FELCOM 16; it is
already installed on the FELCOM 15.
Separate t he junction box from a magnetic com pass by the distances shown bel ow to
prevent deviation to a magnetic compass.
Standard compass : 1.0 m
St eer ing compass: 0.7 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the m ounting location with four self-tapping screws (4x 16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
±
0.5
70
The junc tion box is connected to the
connector ( at the
of the
communication unit.
communi c at ion unit). Therefore, locat e t he junction box wit hin two meters
120 ±0.5
Junction box IC-315
communi c at ion unit with a 2 meter cable, with D-sub
5
Page 8
2.1.2 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviati on to a magnetic compas s.
Standard compass : 0.70 m
St eer ing compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location shoul d be
known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove f our s cr ews from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (suppli ed) .
3. The cable can be lead in from the bottom or the rear p anel. For rear panel entrance,
change the clamp orientation as follow s :
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Clamp
Rotate
Fasten three screws.
4. Run the cable thru one of the c able entrances and connect it to terminal board.
6
Page 9
5. Attach the swit c h c over as shown below. Note that t he c over may also be rotated 180
degrees.
Switch cover
Flush mounting
The optional flush mount ki t OP16-28 (Code No. 004- 448-010) is required.
Fixture 16-018-7201-1 100-317-9311
Pan head screw M3x6 000-800-3624
Self-tapping screw 4x16 000-802-0804
Name Type Code No. Qty Remarks
1. Cut out the mounting position referring to the outline draw ings at the back of this
manual.
2. Fix the unit to the fix ture with four pan head s cr ews (suppli ed) .
3. Fasten the fixture with the unit to the mount ing location wi th four self-tapping screws
(supplied).
4. Attach switch c over as shown above.
7
Page 10
2.2 Wiring
2.2.1 Junction box (for FELCOM 16)
Use the juncti on box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten
four screws to remove the cover to connect cables to terminal board. For detailed wiring
informat ion see the interconn ec tion diagram.
For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equi valent , see
next page for sectional view of t his cable) or the CO-SPEVV-SB-C 0.2x5P. When using the
CO-SPEVV -SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with the juncti on box . For connecting the communicati on unit
IC-216, us e cable 16S0344.
Vcc
1
GND
2
TD/RD-A
Communication
Unit
Cable clamp
Terminal
board
Cover
Cable clamp
(top)
Cable clamp
(bottom)
3
TD/RD-B
4
NC
5
TD-A(NAV)
6
TD-B(NAV)
7
RD-A(NAV)
8
RD-B(NAV)
9
GND
10
DMC OUT-H
11
DMC OUT-C
12
DMC IN-H
13
DMC IN-C
14
DMC CTR
15
IC-305/306
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
1
2
3
Core 7 mm
16S0344
Fold back braided shield onto
sheath and fix by cable clamp.
90mm15mm7mm
Junction box IC-315
3. Insert cable core to 3 .
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Note 2: Pull each cable slightly to confirm that they are in their holes securely.
8
Page 11
2.2.2 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnect ion diagram at t he bac k of this manual. For the terminal unit (FELCOM 15) and
the communicati on unit (FELCOM 16), the wiring of the SSAS is monitored and if in error
“TROUBLE: SSAS UNI T connection abnormal ity .” is displayed. Further the ERROR lamp
(FELCOM 16) flashes.
Junction
Box
IC-307
(No.1)
IC-307
(No. 2)
IC-307
(No. 3)
Connect wiring to the terminal board 16P0229 inside the SSAS alert unit. To differentiate
between units in case of multiple unit installation, change jumper block set tings as shown
below, in accordance with how many units are installed.
Jumper settings for two IC-307
Unit
Jumper
JP1
JP2
No. 1 unit: Unit with two cables connnected to it.
No. 2 unit: Unit with one cable connnected to it.
Two IC-307: No. 2 unit
Three IC-307: No. 3 unit
16P0229
JP1
12345
No.1 unit*No. 2 unit
No
Yes
JP2
Yes
No
Three IC-307: No. 1 and No. 2 units
6
*: Default
setting
Two IC-307: No. 1 unit
16P0229
Jumper settings for three IC-307
Unit
Jumper
JP1
JP2
No. 1 and No. 2 units: Units with two cables connnected to them.
No. 3 unit: Unit with one cable connnected to it.
JP2
JP1
12345
No.1 unit*
No
Yes
6
No. 2 unit*
No
Yes
No. 3 unit
Yes
No
Clamp for cable
CO-SPEVV-SB-C
0.2x5P
Clamp for cable
TTYCS-4
or equivalent
IC-307
IC-307
Cable Fabrication
Twist shield.
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Cut and tape
unused wires
to prevent short.
f = 16.3
mm
Conductor
Sectional view of cable TTYCS-4
Wiring inside the SSAS alert unit
9
15 mm 40 mm 10 mm
Armor
Sheath
Shield
S = 0.75 mm
φ = 1.11 mm
2
Page 12
2.3 Enabling USCG Version
1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Ent er ] key.
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
3. Type “furunoservice” ( without quot ation marks) in the Ent er J O B No. field and then press
the [Enter] key. The prompt PAS SWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [ E nt er] key. Then,
the item M ain Menu is display ed in reverse video.
5. Press [1], [Enter], [1], [Enter]. O ne of the following wi ndows appears.
[ DMC ]
1. SSAS(IC-307)
2. DMC
3. OFF
4: SSAS(Momentary SW) E: Exit
Enter No.:
FELCOM 15
[ SSAS ]
1. ON(IC-307)
2. OFF
3: Momentary SW (for USCG)
E: Exit
Enter No.:
FELCOM 16
6. Press [4] (FELCOM 15) or [3] (FELCOM 16) to enable the USCG v ers ion.
7. Press the [Esc] key several times to clos e the menu.
10
Page 13
3. OPERATION
3.1 Operation Mode
There are two menu operating m odes :
Normal mode: Menus other than SSAS-related menus are displayed.
SSAS manager mode: The mode is activated by t he password entered by the ship’s
captain or aut horized personnel. The indication “SSAS Manager
Mode” is s hown at the top of the scr een when this mode is
activated, and it is flashing. All SSAS-related menus are available.
Transmission of the SSAS report may be cancelled in this mode.
The equipm ent starts up in the normal mode, regar dless of the
mode in use when the power i s tur ned off.
3.1.1 Changing the password
The default password is “ship security alert”. Ship’s captain or authorized personnel m ay
change the p as s word as follows:
1. FELCOM 15: Press [F8], [2] to show the System Setup m enu.
FELCOM 16: Press [F8], [1] to show the Sys tem Setup menu.
2. Press [↓] to choose Command Window and then press the [Ent er ] key.
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
3. On the Enter JOB No. field, type “ssas password” (without quotat ion marks) and then
press the [Ent er ] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW
PASSWORD appears.
5. Enter new pas sword, using at least six characters, and then press the [Ent er ] key. The
prompt RETYPE NEW PASSWORD app ear s .
Note: I f less than six characters ar e entered, the mes s age “Please use a longer
password.” appears. Enter a longer password.
6. Enter new pas sword again and then pres s the [Enter] key. The message “Password
changed” appears.
7. Press the [Esc] key several times to close the menu.
Note: The SSAS manager mode cannot be acc essed without the correct password.
11
Page 14
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the f ollowing to access
this mode.
1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
3. On the Ent er JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
Note: If there is no SSAS equipment connected, t he m essage "Command Ignored: No
SSAS button is installed." appears.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode
is activated, and it is flashing.
5. Press the [Esc] key several times to close the menu. This enables the SSAS manager
mode, which allows you to execute the proced ure in paragraph 3.2.
Note: Turn the power off and on again whenever changing SSAS-related settings.
12
Page 15
3.2 Setting SSAS Report Destination and
Message Contents
When the SSAS is acti vated, t he SSAS report is sent according to the addresses (max. 5)
and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu.
Note 1: The dest ination and message c ontent of an SSAS repor t vary according to
Adminis tration. T her ef or e, set them as requested by ship’s authorities. For
informat ion other than ship’s name, MM SI no. and IMN no., set it manually with
“Other Inf.”
Note 2: The equi pment must be in the SSAS manager mode to exec ute this procedure.
See paragr aph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports
1. Data Report
2. Message Report
3. Data Network ID
4. SSAS Report
2. Press the [4] key to shown the SSAS Report menu.
SSAS Report
1. SSAS Report 1
2. SSAS Report 2
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
6. Message Contents
3. Press [1], [2], [3] , [4] or [5] key as appropri ate and then window below appears.
SSAS Report
Status
Mode
Station Name
Destination Type
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Subject
LES ID
Report Interval
ON
Real+Test
TELEX
02:00 (hh: mm)
13
Page 16
4. Press the [↓] key to choos e Mode and then press the [Enter] key.
Real+Test
Real Only
Test Only
5. Press the [↑] or [↓] key to choose mode des ired and then press the [Enter] key.
“Mode” defines what SSAS report(s) a stati on is to receive:
Real+Test: Actual SSAS report and test SSAS report.
Real Only: Actual SSAS report only.
T est Only: Test SSAS report only.
6. Press the [↓] key to choos e Station Name and then press the [Enter] k ey.
7. Press the [↑] or [↓] key to choose appropriate station and then press the [ E nter] key.
You may sort the list by group name, station name or communic ation type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or
descending or der.
Station name: Each press of [Ctrl] + [ N] s orts the list by station name, in ascendi ng or
descending or der.
Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in
ascending or des cending order.
8. Press the [↓] key to choos e LE S ID and then press t he [Enter] key.
9. Press the [↑] or [↓] key to choose LES a nd then press the [Ent er ] key.
Note: Cha nge the LES whenev er sea area has changed. However, the equipment
automatic ally searches for an LES with which you can c om municate and t he
SSAS report is transmi t ted to that LES.
10. Press the [↓] key to choose Report Interval and then press the [Enter] key.
11. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
12. Press the [Esc] key to open the Update window .
SSAS Report
Status
Mode
Station Name
Destination Type
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Subject
LES ID
Report Interval
ON
Real+Test
TELEX
02:00 (hh: mm)
Yes
Update
No
13. Yes is selected; press the [Enter] key to close the SSAS report wi ndow.
14
Page 17
14. Press the [6] key to display t he SSAS Message Cont ents menu.
15. Press the [Enter ] key to open the Vessel Name window.
16. Enter vessel’s name and then press the [Enter] key.
17. Press the [↓] key to choose MMSI and t hen press the [Enter] k ey.
18. Enter MMSI num ber and then press the [Ent er ] k ey.
19. Press the [↓] key to choose IMN and then press the [Enter] key.
20. Enter IMN and t hen pr es s t he [Enter] key.
21. Press the [↓] key to choose Other I nf. and then press the [Enter] key
22. Enter appropri ate message (thre e lines) and then pres s the [Enter] key.
Note: To shift between lines, use the [↑] or [↓] key.
23. Press the [Esc] key to open the Update window.
24. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
25.Press the [ E s c ] key twice to ret ur n t o the standby display.
Note 1: To delete entered subscr iber’s data, choose “Remove” f r om “ Status .”
Note 2: SSAS report setti ngs may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window .
FELCOM 16: [F8], [8], [6] to show the Save/Load window .
Save to FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
Load from FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
*: Availlable only in SSAS manager mode
("5.SSAS Report" is added in the SSAS
manager mode and item numbers are shifted.)
Note 3: To confirm the sett ings, follow par agr aph 3.5.
15
Page 18
3.3 Transmitting SSAS Report
The SSAS report i s sent one second after the but t on on the SSAS is pressed. Repeate d
transmiss ion can only be stopped from the SSAS m anager mode.
1. Open the cover of the SSAS alert button.
Cover
2. Push the button one second. The but ton is a momentary switch, meaning it is activated
as soon as it is pressed one second.
3. The SSAS report is transmitted after the button is pushe d one second. Below are the
contents of t he SSAS report.
Ship's Name
MMSI No.
IMN No.
Desired message
Own ship postion in latitude
Own ship position in longitude
Time of position data
Course
Speed
Time of course and speed data
4. An LES sends acknowledgement to y our s hip.
5. For multiple dest inations, steps 3 and 4 are automatically repeated (it is not necessary to
push the button again).
Cancelling repeated trans mi ssion
T erminal Unit: Turn off the communicat ion unit. Press and hold down the butt on on the
SSAS unit while turning on the communication u nit. Release the button when the test mode
starts. (The FELCOM 16 goes into the button test mode.) Note that if there are any unsent
messages t hey are sent and then t he system goes into nor m al operation; nam ely, the test
mode is not act ivated.
PC: Open the SSAS manager (see p age 12) and input the command TERMINATE SSAS
ALERT.
16
Page 19
3.4 Testing the Button
The SSAS buttons can be tested as below .
Note 1: An actual SSAS report cannot be transmitt ed during the testing.
Note 2: The equipment must be in t he SSAS manager mode to conduct the test .
FELCOM 15
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ( [6] key when the FELCOM functions as an EGC rec eiver) to displ ay
the Test menu.
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test
3. Press the [4] key.
Test
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Yes
Start
No
4. Press the [Enter] k ey to start the test.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
Distress/SSAS buttons are under test mode.
3. Self Test
5. Ocean Region
INF: Distress/SSAS Buttons entered into TEST MODE.
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Press any key to escape.
<Press ESC key to continue>
CAUTION
The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT w orks
correctly.” appears if the unit is functioni ng pr operly.
7. Five seconds after pressing t he button the SSAS test report is aut omatically sent to
stati on whose Mode set on the SSAS Report w indow is “Real+Test” or “Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appro priate button.
17
Page 20
8. To escape from the test, press t he [Esc] key twice on the terminal unit . The test mode is
stopped and the message shown below appears t o notify you that norm al operation has
been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
9. Press the [Esc] key three times to return to the standby display.
18
Page 21
FELCOM 16, no PC
Turn off communication unit.
Press button of No.1 SSAS
while turning on communication
unit. Continue pressing button.
30 s
When POWER, LOGIN and TX
lamps flash, release button.
Press and hold down button
of No.1 SSAS.
POWER, LOGIN and TX lamps
flash and then go off.
Send SSAS
test report?
Yes (TX starts after button is
pressed and held 5 s.)
SSAS report is sent to station(s)
whose mode is "Real+Test" or "Test
Only". (See paragraph 3.2.)
Lamps flash rapidly during TX.
Test
successful?
Yes
POWER, LOGIN and TX lamps
flash in that order.
Release button of No.1 SSAS.
POWER, LOGIN and TX lamps
flash in that order and go off.
No
ERROR lamp flashes rapidly.
No
T est TX
Press and hold down button
of No.2 SSAS.
Same procedure as No.1 SSAS.
Release button of No.2 SSAS.
Turn communication unit off and
on again.
Note: If a 3rd SSAS unit is
installed test it by
procedure used to test No.2
19
Page 22
FELCOM 16, PC version
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ( [6] key when the FELCOM functions as an EGC rec eiver) to displ ay
the Test menu.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test
3. Press the [4] key.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Test
SSAS Button Test
Yes
Start
No
4. Press the [Enter] k ey to start the test.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
Distress/SSAS buttons are under test mode.
3. Self Test
5. Ocean Region
INF: Distress/SSAS Buttons entered into TEST MODE.
4. Distress Alarm Button Test
6. Test
Test
Distress/SSAS Button Test
Press any key to escape.
CAUTION
<Press ESC key to continue>
The display shows the message (in red) “SSAS buttons are u nder test. Cancel the test
mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT works
correctly.” appears if the unit is functioni ng pr operly.
7. Five seconds after the button is pushed the SSAS test report is automatically sent to the
stati on(s) whose Mode set on the SSAS Report w indow is “Real+Test” or Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appro priate button.
8. To escape from the test, press t he [Esc] key twice on the terminal unit . The test mode is
stopped and the message shown below appears t o notify you that norm al operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
9. Press the [Esc] key three times to return to the standby display.
20
Page 23
3.5 SSAS Report Test
You can test for successful transmission of the SSAS report to the address you specify,
without using the button. The test report m essage states “!!! Test Call !!!” to alert the
receiver of the message that i t is a test call.
Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then f ollow this procedur e.
1. Press the [F5] key to open the Reports menu.
2. Press the [4] key to choose the SSAS Report m enu.
3. Press the [1], [2], [3], [4] or [5] key as appropriat e, and the SSAS report setting menu
appears.
4. Set destination w her e to transmit the test.
5. Press the [↑] key to choose Status and then press the [ E nter] key.
6. Press the [↓] key to choose TEST and then pr ess the [Ent er ] key.
7. Press the [Esc] key to open the Update window.
8. Yes is selected; press the [Enter] key. The test report is transmitt ed. Af ter it is
transmit ted, “Status” is automatically set to O N.
9. Press the [Esc] key twice to return to the s tandby display.