SPECIFICATIONS
Remote Control Unit
RCU-015
RCU-016
1.5 m
5/10 m
250V-TTYCS
250V-TTYCS/
MPYC
MU-201CE/
231CE
10/20/30 m 10/20/30 m
2.5 m
10/20/30 m
LAN Adapter
EC-1010
24 VDC
1.5 m
100-230 VAC
Option Shipyard Supply
Display UnitControl Unit
ECDIS for 2nd station
Processor Unit
EC-1000C
HUB
HUB-100
AIS
Track Pilot *
AMWSS
Route Backup
GPS Navigator
Anemometer
Echo Sounder
Log/Dual Axis Log
Gyrocompass
Engine Control
Water T emp Indicator
Alarms
B Adapter
EC-1020
24 VDC
x8
x2
x8
5 m
Conning Monitor
Gyrocompass (Synchro)
Log (200 p/nm)
Alarms
Analog Sensors
Radar/ARPA*
HUB
HUB-100
INTERCONNECTION DIAGRAM
RCU-018
or
FAR-21x7
series
FAR-28x7
series
Standards IMO Resolution A.817(19), IEC 61174 ed2
Display Unit FEA-2107: MU-201CE, 20.1" color LCD, SXGA (1280 x 1024 pixels)
FEA-2807: MU-231CE, 23.1" color LCD, UXGA (1600 x 1200 pixels)
Operating System Windows XP
Useable Charts IHO/S-57 v.3 vector chart, ARCS raster chart, C-MAP CM93 ed3*
*available in the near future
Presentation Modes True/Relative Motion Noth-up, True/Relative Motion Course-up
Relative Motion Head-up, Relative Motion Route-up
Display of data
Own ship : Position, SOG, COG, Heading
Route : Planned route, Monitoring route
ARPA targets : Range, Bearing, Speed, Course, CPA and TCPA
Others :
EBL, VRM, Parallel index line, Cursor position, Navigation
and pilot data notebook
Route/Waypoint Route: more than 100 routes
Waypoints: 200 waypoints/route
Voyage Calculation The following data can be calculated
Range/Bearing to destination, TTG, ETA, Fuel consumption
Route Navigation Monitoring
Off track, Waypoint, Arrival, Grounding, Depth
Alarms
Off track, Channel limit, Waypoint approach, Depth
Other Functions Night/day presentation colors, ARPA target display, Radar overlay,
User chart function, Position optimization, MOB, Log book,
Pilot data function,
Track control system (TCS)*
* Please contact the local dealers in your area for details.
Interface
Input/output
AIS : IEC 61162-2 (ABM, BBM)
Radar signal : Ethernet 100 Base-TX or RAW Video
Input
Gyrocompass : IEC 61162-1 (HDT) or Synchro
SDME (Speed log) : IEC 61162-1 (VBW) or Pulse type
EPFS : IEC 61162-1 (GLL, GGA, VTG, ZDA, DTM)
Echo Sounder : IEC 61162-1 (DBT, DPT)
Anemometer : IEC 61162-1 (MWV)
Water temp Indicator : IEC 61162-1 (MTW)
Current Indicator : IEC 61162-1 (VDR)
Output
Alarms : Relay output
Printer : Parallel
Power Supply
Display Unit: 100 - 230 VAC, 1 ø, 50/60 Hz
Processor Unit: 100 - 230 VAC, 1 ø, 50/60 Hz
LAN Adapter: 24 VDC
B Adapter: 24 VDC
Environment (IEC 60945 test method)
Temperature
All Units:
-
15˚C to +55˚C
Equipment List
Standard
1.
Display Unit FEA-2107: MU201CE, FEA-2807: MU-231CE
1 unit
2. Control Head RCU-018 or
Trackball Control Unit RCU-015 (Specify when ordering)
1 unit
3. Processor Unit EC-1000C 1 unit
4. LAN Adapter EC-1010 1 unit
5. Power Supply Cable for Processor Unit, 1.5 m 1 pc
6. Power Supply Cable for Display Unit, 1.5 m 1 pc
7.
DVI Cable between Display Unit and Processor Unit, 5 m 1 pc
8.
Cable between Control Unit and Processor Unit, 10 m 1 pc
9. LAN Cable, 2 m
1 pc
10. Standard Spare Parts and Installation Materials 1 set
Option
1. LAN Adapter EC-1010
2. B Adapter EC-1020 for equipment with analog interface
3. Remote Control Unit RCU-016
4. Cable between Control Unit and
Remote Control Unit 03S9610, 1.5/10/20/30 m
5. Hub HUB-100
6.
Radar Overlay Kit for FAR-21x5 series and FAR-28x5 series
7. Video Card for Conning Display Unit
8. Cable between Control Unit and Processor Unit, 20/30 m
9. DVI Cable between Display Unit and Processor Unit, 10 m
10. Armored LAN Cable OP03-186-10/20/30
11. Printer PP-510
12. USB-Parallel Printer Cable for PP-510
13. Hand Grip
14. Bracket
15. Connection Stand
16. Pedestal slim/standard Type
The future today with FURUNO's electronics technology.
9-52 Ashihara-cho, Nishinomiya City, Japan Phone: +81 (0)798 65-2111
Fax: +81 (0)798 65-4200, 66-4622 URL: www.furuno.co.jp
TRADE MARK REGISTERED MARCA REGISTRADA
Catalogue No. L-161b
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
TRADE MARK REGISTERED
MARCA REGISTRADA
05015U Printed in Japan
Ethernet
Ethernet
250V-TTYCS-1T
250V-
TTYCS-1
Serial
554 21.8"
570 22.4"
313 12.3"
471 18.5"
598 23.5"
590 23.2"
Hand Grip
(option)
92 3.6"
398 15.7"
308 12.1"
136 5.4"
180 7.1"
4- 4
54 2.1"
39 1.5"
110 4.3"
4- 4
160 6.3"
136 5.4"
180 7.1"
89 3.5"
50 2.0"
35 1.4"
110 4.3"
4- 4
160 6.3"
136 5.4"
180 7.1"
89 3.5"
50 2.0"
35 1.4"
110 4.3"
5
0
5
1
9
.
9
"
451 17.8"
35
287 11.3"
352 13.9"
Bracket
(option)
534 21.0"
526 20.7"
Hand Grip
(option)
490 19.3"
296 11.7"
420 16.5"
506 19.9"
110 4.3"
4
5
4
1
7
.
9
"
409 16.0"
35
287 11.3"
352 13.9"
Bracket
(option)
440 17.3"
470 18.5"
150
5.9"
150
5.9"
50
2.0"
486 19.0"
395 15.6"
10
0.4"
179 7.1"
6- 8
Display Unit Processor Unit
Control Head
Trackball Control Unit
Remote Control Unit
RCU-015 2.4 kg 5.3 lb
RCU-016 2.4 kg 5.3 lb
EC-1000C 15 kg 33.1 lb
RCU-018 3.7 kg 8.2 lb
MU-201CE 18.3 kg 40.4 lb
MU-231CE 23.5 kg 51.8 lb
20.1" color LCD
23.1" color LCD
*
Up to two LAN
adapters connectable
*Please contact the local dealers in your area for details.
Digitizer
Printer
PP-510
With 8 ports
With 18 ports
*Up to four systems can
be connected
58 669 02 20
FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
Phone: +1 360-834-9300
Fax: +1 360-834-9400
FURUNO (UK) LIMITED
Denmead, Hampshire, U.K.
Phone: +44 2392-230303
Fax: +44 2392-230101
FURUNO FRANCE S.A.
Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00
Fax: +33 5 56 13 48 01
FURUNO ESPAÑA S.A.
Madrid, Spain
Phone: +34 91-725-90-88
Fax: +34 91-725-98-97
FURUNO DANMARK AS
Hvidovre, Denmark
Phone: +45 36 77 45 00
Fax: +45 36 77 45 01
FURUNO NORGE A/S
Ålesund, Norway
Phone: +47 70 102950
Fax: +47 70 127021
FURUNO SVERIGE AB
Västra Frölunda, Sweden
Phone: +46 31-7098940
Fax: +46 31-497093
FURUNO FINLAND OY
Espoo, Finland
Phone: +358 9 4355 670
Fax: +358 9 4355 6710
FURUNO POLSKA Sp. Z o.o.
Gdynia, Poland
Phone: +48
Fax: +48 58 669 02 21