Fujitsu fi-5110C User Manual

fi-5110C Image Scanner
P3PC-1072-03EN
Getting Started
fi-5110C Image Scanner
Getting Started

CONTENTS

Note, Liability ....................................................................... iv
Safety Precautions ................................................................ v
Chapter 1 PREPARING THE SCANNER.................................. 1
1.1 Checking the Contents of the Scanner Package............. 1
1.2 Names of Parts ................................................................... 1
1.3 Operator Panel.................................................................... 2
Chapter2 INSTALLATION OF THE SCANNER...................... 3
2.1 Installing the Scanner Application ................................... 3
2.2 Installing the Scanner ........................................................ 9
2.3 Connecting the USB Cable .............................................. 10
2.4 Confirming Installation .................................................... 11
Appendix 1 TROUBLESHOOTING........................................ AP-1
Appendix 2 DAILY CARE ...................................................... AP-4
Appendix 3 REPLACING CONSUMABLES.......................... AP-5
fi-5110C Image Scanner Getting Started i

INTRODUCTION

Thank you for purchasing the fi-5110C Duplex Color Scanner. This document describes how to handle fi-5110C Duplex Color Scannerand basic operation methods. Before you start using fi-5110C Duplex Color Scanner, be sure to thoroughly read this manual to ensure correct use.
ATTENTION
The use of a shielded interface cable is required to comply with the Class B limits of Part 15 of FCC rules. The length of the AC cable must be 2 meters (6.6 feet) or less.
The "Operator’s Guide" is stored on the Setup Disk. The guide provides useful and detailed information on Operations when you would like to using advanced fea­tures, daily maintenance of the scanner, replacement of consumables.Please also read the Operator’s Guide for your reference.

Regulatory Information

FCC declaration
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Canadian DOC Regulations
This digital apparatus does not exceed the Class B limit for radio noise emissions from digital apparatus set out in the Radio interference Regulations of the Canadian Department of Communications. This Class B digital apparatus complies with Canadian ICES-003.
Le présent appareil numérique n'émet pas de parasites radioélectriques dépassant les limites applicables aux appareils numériques de la classe B et prescrites dans le Règlement sur le brouillage radioélectrique dictées par le Ministère des Communications du Canada. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Bescheimigung des Herstellers / Importeurs
Für den fi-5110C wird folgendes bescheinigt:
In Übereinsstimmung mit den Bestimmungen
der EN45014(CE) funkentstört
Maschinenlärminformationsverordnung 3.
GPSGV: Der höchste Schalldruckpegel beträgt 70 dB (A) oder weniger, gemäß EN ISO 7779.
Increase the separation between the equipment
and receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is located.
Consult your dealer or an experienced radio/TV
technician.
FCC warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
ii
International ENERGY STAR® Program
As an ENERGY
®
STAR
LIMITED has determined that this product meets the
ENERGY STAR
guidelines for energy efficiency.
The International Equipment Program is an international program
that promotes energy saving through the
Partner, PFU
®
ENERGY STAR
®
Office
penetration of energy efficient computers and other office equipment. The program backs the development and dissemination of products with functions that effectively reduce energy consumption. It is an open system in which business proprietors can participate voluntarily. The targeted products are office equipment such as computers, monitors, printers, facsimiles, copiers, scanners, and multifunction devices. Their standards and logos are uniform among participating nations.
Use in High-safety Applications
This product has been designed and manufactured on the assumption that it will be used in office, personal, domestic, regular industrial, and general-purpose applications. It has not been designed and manufactured for use in applications (simply called "high-safety applications" from here on) that directly involve danger to life and health when a high degree of safety is required, for example, in the control of nuclear reactions at nuclear power facilities, automatic flight control of aircraft, air traffic control, operation control in mass-transport systems, medical equipment for sustaining life, and missile firing control in weapons systems, and when provisionally the safety in question is not ensured. The user should use this product with adopting measures for ensuring safety in such high-safety applications. PFU LIMITED assumes no liability whatsoever for damages arising from use of this product by the user in high-safety applications, and for any claims or compensation for damages by the user or a third party.
About the Use of Mercury
Lamp(s) inside this product contain mercury and must be recycled or
g
H
To avoid unexpected injury, read the following carefully. Doing the following actions may result in serious personal injuries:
disposed of according to local, state, or federal laws.
Trademarks
Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation in the United States and/or other countries. ISIS and QuickScan are trademarks or registered trademarks of EMC Corporation in the United States. Adobe, the Adobe logo, and Acrobat are either registered trademarks of Adobe Systems Incorporated in the United States and/or other countries. Other product names are the trademarks or registered trademarks of the respective companies.
How Trademarks Are Indicated In This Manual
References to operating systems (OS) and applications are indicated as follows:
Windows 95
Windows 98
Windows Me
Windows NT 4.0
Windows 2000
Windows XP
Microsoft operating system
Microsoft operating system.
Microsoft Millennium Edition operating system.
Microsoft Server operating system,
Microsoft Workstation operating system.
Microsoft Professional operating system.
Microsoft Professional operating system,
Microsoft Home Edition operating system.
Where there is no distinction between the different versions of the above operating system, the general term "Windows " is used.
Adobe Acrobat 7.0
Adobe® Acrobat® 7.0 Standard
®
Windows® 95
®
Windows® 98
®
Windows®
®
Windows® NT 4.0
®
Windows® NT 4.0
®
Windows® 2000
®
Windows® XP
®
Windows® XP
Do not put the substance contained in the lamp
in your mouth as it has mercury.
Do not breathe the chemical liquid contained in
the scanner lamps.
Do not incinerate, crush, or shred the lamps or
scanner parts.
fi-5110C Image Scanner Getting Started iii
Manufacturer
PFU LIMITED
International Sales Dept., Imaging Business Division, Products Group Solid Square East Tower, 580 Horikawa-cho, Saiwai-ku, Kawasaki-shi Kanagawa 212-8563, Japan Phone : (81-44) 540-4538
All Rights Reserved, Copyright© PFU LIMITED 2006
Symbols Used In This Manual
ATTENTION
HINT
This symbol alerts operators to particularly important information. Be sure to read this information.
This symbol alerts operators to helpful advice regarding operation.

Note, Liability

BEFORE USING THIS PRODUCT, PLEASE READ THIS MANUAL CAREFULLY. IF THIS PRODUCT IS NOT USED CORRECTLY, UNEXPECTED INJURY CAN OCCUR TO USERS OR BYSTANDERS.
Keep this manual in a safe place so that it can be easily referred to during use of this product.
While all efforts have been made to ensure the accuracy of all information in this manual, PFU assumes no liability to any party for any damage caused by errors or omissions or by statements of any kind in this manual, its updates or supplements, whether such errors are omissions or statements resulting from negligence, accidents, or any other cause. PFU further assumes no liability arising from the application or use of any product or system described herein; nor any liability for incidental or consequential damages arising from the use of this manual. PFU disclaims all warranties regarding the information contained herein, whether expressed, implied, or statutory.
Warning Indications Used In This
A TRIANGLE symbol indicates that special care and attention is required. The drawing inside the triangle shows the specific caution.
A CIRCLE with a diagonal line inside shows action which users may not perform.
The drawing inside or under the circle shows the specific action that is not allowed.
Outline characters on a colored background show instructions users should
R
follow. It may also include a drawing that shows
the specific instruction.
Warning Label
The glass surface inside the ADF becomes hot during the operation. Be careful not to touch the glass surface inside the ADF.
ATTENTION
Do NOT remove from the scanner, stain or scratch the warning labels.
Manual
WARNING
CAUTION
iv
This indication alerts operators to an operation that, if not strictly observed, may result in severe injury or death.
This indication alerts operators to an operation that, if not strictly observed, may result in safety hazards to personnel or damage to equipment.
Screen Examples In This Manual
The screen examples in this manual are subject to change without notice in the interest of product improvement. If the actual displayed screen differs from the screen examples in this manual, operate by following the actual displayed screen while referring to the User's Manual of the scanner application you are using. The screenshots in this manual were captured from FUJITSU TWAIN32 scanner driver, ScandAll 21 Image Capturing Utility Software,
FUJITSU ISIS scanner driver, QuickScan™
®
image capturing software and Adobe
Acrobat®.
Wipe any dust from the power plug.
About Maintenance
The user must not perform repairs on this scanner. Contact the store where you purchased the scanner or an authorized FUJITSU Image Scanner service provider to have repairs done on this product.

Safety Precautions

WARNING
Do not damage the AC cable.
A damaged AC cable may cause fire or electric shock. Do not place heavy objects on AC cables, or pull, bend, twist, heat, damage or modify AC cables. Do not use damaged AC cables or power plugs, or install any cables or power plugs to loose wall sockets.
Use only specified AC cables and connector cables.
Use only specified AC cables and connector cables. Failure to use the correct cables might cause electric shock and/or equipment failure.
Use this scanner only at the indicated power voltage. Do not connect to multiple-power strips.
Wipe off any dust from metal parts on the power plug or metal fittings with a soft, dry cloth. Accumulated dust can cause fire or electric shock.
Do not install the device in locations that has oil smoke, steam, humidity, and dust.
Do not install the scanner in locations subject to oil smoke, steam, humidity, and dust. Doing so might cause a fire or electric shock.
Turn the scanner OFF if it is damaged.
If the scanner is damaged for any reason, turn the scanner off and unplug the power cable. Contact the store where you purchased the scanner.
Do not put liquids inside the scanner.
Do not insert or drop metal objects in to the scanner. Do not scan wet documents or documents with paper clips or staples. Do not splash or allow the scanner to get wet.
If foreign objects (water, small metal objects, liquids, etc.) get inside the scanner, immediately turn off the scanner and dis­connect the power plug from the power out­let. Then, contact the store where you bought the scanner or the Maintenance Ser­vice Center. Pay particular attention to this warning in households where there are small children.
Use this scanner only at the indicated power voltage and current. Improper power voltage and current might cause fire or electric shock. Do not connect to multiple-power strips.
Do not touch the AC cable with wet hands.
Do not touch the power plug with wet hands. Doing so might cause electric shock.
fi-5110C Image Scanner Getting Started v
Do not touch the inside of the scanner unless necessary.
Do not take apart or modify the scanner. The inside of the scanner contains high­voltage components. Touching these components might cause electric shock or fire.
Do not use the scanner if you smell a
Avoid any contact when scanner is in
strange odor.
If you detect heat coming from the device or detect other problems such as smoke, strange smells or noises, immediately turn off the scanner and then disconnect its power plug. Make sure that any smoke coming from it has stopped, before contacting the store where you bought the scanner or an authorized FUJITSU scanner service provider.
CAUTION
Do not install the scanner on unstable surfaces.
Make sure that the scanner is installed on a flat, level surface and that none of its parts extend beyond the surface top, such as a desk or table. Do not install the scanner on unstable surfaces. Install the scanner on a level surface that is free of vibration to prevent it from falling.
Install the scanner on a strong surface that will support the weight of the scanner and other devices.
Do not block the ventilation ports.
Do not block the ventilation ports. Blocking the ventilation ports generates heat inside of scanner, which may result in fire or scanner failure.
use.
Avoid touching any scanner mechanism during scanning since this may cause injuries.
Do not use the scanner immediately after moving it from a cold place into a warm room.
Do not use the device immediately after moving it from a cold place into a warm room. Condensation may occur, which might lead to scanning errors. Let the device dry about one or two hours before you use it.
Before moving the scanner, disconnect the power plug from the power outlet.
Do not move the scanner with the power and interface cables connected as this can damage the cables, which can later cause fire, electric shock as well as injury. Before moving the scanner, be sure to disconnect the power plug from the power outlet, and all other data cables.
Make sure that the floor is free of any obstructions.
Protect the scanner from static electricity.
Do not place heavy objects or climb on top of the scanner.
Do not place heavy objects on the scanner or use the scanner's surface top to perform other work. Improper installation might cause injuries and equipment failure.
Firmly insert the power plug.
Firmly insert the power plug as far it can go into the power outlet.
vi
Install the scanner away from strong magnetic fields and other sources of electronic noise. Also, protect the scanner against any static electricity, which can cause the scanner to malfunction.
Do not use aerosol sprays near the scanner.
Do not use aerosol sprays to clean the scanner. Aerosol sprays can blow dirt and dust inside the scanner, resulting in scanner failure or malfunction.
Disconnect the power plug from the power outlet when the scanner is not used for a long period of time.
When the scanner is not going to be used for a long period of time, be sure to disconnect the power plug from the power outlet for safety.
Do not install the scanner in direct sunlight.
Do not install the scanner under direct sunlight or near heating apparatus. Doing so might cause excessive heat to build up inside the scanner, which can cause scanner trouble or even fire. Install the scanner in a well-ventilated location.
fi-5110C Image Scanner Getting Started vii

Chapter 1 PREPARING THE SCANNER

1.1 Checking the Contents of the Scanner Package

When you open the scanner package, please handle the main unit and its attachments carefully.
Make sure it contains all the parts listed in the package contents list that is included in the package box. If any parts are missing or defective, contact your sales representative.

1.2 Names of Parts

This section describes the scanner parts.
Front
ADF paper chute
Automatic document feeder(ADF)
ADF open lever
Side guide
Rear
USB Interface connector
DC inlet
Security Cable Slot
Removable Parts
Parts that can be removed from the scanner are dis­played below.
ADF paper chute
Sheet Guide
Stacker
Operator panel
Pad ASSY
Pick Roller
1

1.3 Operator Panel

The operator panel is located on the right side of the scanner. This panel is comprised of a Function Number display, four buttons and a LED.
Function No display
Function
Send to
Scan
Power button
Indications on the Function Number display
8
Blinks only one time upon turning on the scan­ner.
P
Indicates that the scanner has been turned ON and is being initialized.
0
Indicates that initialization will soon end.
Name Function
Function Number display
Button Function Changes the Function acti-
Send to Launches the linked appli-
Scan
Power button
LED - Lights when the scanner is
*)
About the settings on the launcher, refer to
Indicates the function Number and error status.
vated by the Send to button (*).
cation software (*).
Turns the scanner ON and OFF.
turned ON.
LED
FUJITSU TWAIN32 scanner driver help and the "fi-5110C Operator’s Guide" in the Setup CD­ROM.
1
Indicates that initialization has ended success­fully. The scanner is now in "Ready Status".
U
Indicates that a temporary error occurred when documents were being scanned. A number appearing in alternation following the U (i.e., 1, 2 and 4) refers to the type of error. To return the scanner to the ready status ("1"), press "Scan" or "Send to" button.
E
Indicates that a device (hardware) alarm has occurred during scanning of documents. "E" and the alarm Number (2 to 9 and c) will appear alternately. To return the scanner to the ready status ("1"), press "Scan" or "Send to" button. If this alarm occurs, turn the power off and on again. If the alarm continues after turning the power on again, contact your service engineer.
fi-5110C Image Scanner Getting Started 2

Chapter2 INSTALLATION OF THE SCANNER

2.1 Installing the Scanner Application

Both the scanner driver and image capturing application software (called "application" hereafter) must be installed on your PC.
There are two types of drivers for scanner, The FUJITSU TWAIN 32 Scanner Driver and FUJITSU ISIS Scanner Driver, as well as two software applica­tions, ScandAll 21 and QuickScan Pro™, are provided with this product. The following sections describe how to install each driver and application.
ATTENTION
Please install the scanner driver before connecting the scanner to your PC. If you connect the scanner before installing the scanner driver, the scan­ner will not operate correctly. If you have connected the scanner beforehand, the "Found New Hard­ware Wizard" screen appears (this screen might differ slightly according to the used OS) . On this screen, click the [Cancel] button to close the Wizard screen and install the scanner driver first.
Installing the FUJITSU TWAIN32 Scanner Driver
ATTENTION
1. Turn on your PC and log on to Windows.
ATTENTION
2. Insert the Setup CD-ROM into the CD drive.
<SETUP DISK START UP SCREEN> appears.
ATTENTION
3. Click [INSTALL PRODUCTS].
Windows XP screenshots are used in this section as examples. The win­dows and operations may slightly vary
depending on your OS
When using Windows 2000 or Win­dows XP, log on as a user with "Administrator" privileges.
This screen may not appear when the "Autoplay" setting of your PC is OFF. In this case, run "Install.exe" in this CD-ROM directly from the "Explorer" or "My Computer".
.
For FUJITSU TWAIN32 Scanner Driver
Preparation
Confirm the following items before installing the appli­cation.
Remove the Setup CD-ROM from its package.
Uninstall any older version of FUJITSU
TWAIN 32 driver if already installed.
ATTENTION
Uninstall [Scanner Utility for Microsoft Windows] from [Add/Remove Pro­grams] of the control panel.
3
4. Click [TWAIN Driver] on the window below.
5. Error Recovery Guide Installation window appears. Error Recovery Guide is a software that displays troubleshooting information on screen when any scanner error occurs. Although this software’s installation is highly recommended, the perfor­mance of the scanner would not be affected if not installed.
8. When the [InstallShield Wizard Complete] win­dow appears, click [Finish].
9. Your computer will be restarted. Do not remove the Setup CD-ROM from the CD drive until your PC has completely restarted.
Installation of the scanner driver is completed.
Installing ScandAll 21
ATTENTION
When you select [Yes] for installing the Error Recovery Guide, [Choose Setup Language] window appears. Select a language and follow the instructions on the window. Error Recovery Guide will automatically continue finishing its installation. Please wait until the installation of TWAIN driver automatically starts.
6. Select a language used for installation on [Choose Setup Language] window and click [OK].
"Scandall 21" is an image capturing software that com­plies with the TWAIN standard. The FUJITSU TWAIN 32 scanner driver enables you to capture images with a FUJITSU image scanner fi-series product.
ATTENTION
When using Windows 2000 or Win­dows XP, log on as a user with "Administrator" privileges.
1. Insert the Setup CD-ROM into the CD drive.
<SETUP DISK START UP SCREEN> appears.
2. Click [INSTALL PRODUCTS].
7. Follow the instructions on the window to install the application.
fi-5110C Image Scanner Getting Started 4
3. Click [ScandAll 21] on the window below.
For FUJITSU ISIS Scanner Driver
Preparation
Remove the Setup CD-ROM from its package.
Installing the FUJITSU ISIS Scanner Driver
4. Select a language used for installation on [Choose Setup Language] window and click [OK].
5. Install the application following the instructions on the window.
6. When the [InstallShield Wizard Complete] win­dow appears, click [Finish].
ATTENTION
Windows XP screenshots are used in this section as examples. The win­dows and operations may vary slightly depending on your OS.
1. Turn your PC on and log on to Windows.
ATTENTION
When using Windows 2000 or Win­dows XP, log on as a user with "Administrator" privileges.
2. Insert the "Setup CD-ROM" into the CD drive.
<SETUP DISK START UP SCREEN> appears.
ATTENTION
This screen may not appear when the "Autoplay" setting of your PC is OFF. In this case, run "Install.exe" in this CD-ROM directly from the "Explorer" or "My Computer".
5
ATTENTION
3. Click [INSTALL PRODUCTS].
For finishing the installation, it may be necessary to restart your computer. Follow the instructions on the window.
4. Click [ISIS Driver] on the window below.
Installing QuickScan Pro™
"QuickScan Pro™" is an image capturing software that complies with the ISIS standard. The FUJITSU ISIS scanner driver enables you to capture images with a FUJITSU image scanner fi-series product
5. Error Recovery Guide Installation window
appears. Error Recovery Guide is a software that displays troubleshooting information on screen if any scanner error occurs. Although this software’s installation is highly recommended, the perfor­mance of the scanner would not be affected if not installed.
ATTENTION
When you select [Yes] for installing Error Recovery Guide, the [Choose Setup Language] window appears. Select a language and follow the instructions on the window. The Error Recovery Guide will automatically continue finishing its installation. Please wait until the installation of ISIS driver automatically starts.
ATTENTION
When using Windows 2000 or Win-
dows XP, log on as a user with "Administrator" privileges.
If an older version of QuickScan has
already been installed on your PC, uninstall it before installing this ver­sion.
1. Insert the Setup CD-ROM into a CD drive.
<SETUP DISK STARTUP SCREEN> appears.
2. Click [INSTALL PRODUCTS].
6. Select a language used for installation on
[Choose Setup Language] window and click [OK].
7. Follow the instructions on the window to install
the application.
8. When the [InstallShield Wizard Complete]
window appears, click [Finish].
9. Your computer will be restarted. Do not remove
the Setup CD-ROM from the CD drive until your PC has completely restarted.
Now the installation of the scanner driver is completed.
3. Click [QuickScan PRO (Trial)] on the window below.
4. Continue to install the application following the instructions on the window.
fi-5110C Image Scanner Getting Started 6
5. Enter the required information, then click [Next >] button.
1. Insert the Setup CD-ROM in your CD drive. The <SETUP DISK STARTUP SCREEN> will appear.
2. Click [Install Products].
3. Click [Error Recovery Guide] on the next screen.
ATTENTION
"QuickScan Pro™" included in the Setup CD-ROM is an evaluation ver­sion. For further use after the expira­tion of its evaluation period of up to 30 launches, it is necessary to purchase a fully functional version of QuickScan Pro™. (When you install the evalua­tion version, do not change the Serial Number already displayed.)
6. Install the application following the instructions on the window.
Error Recovery Guide
If you did not install together the Error Recovery Guide with the driver, please proceed with the procedures given below for installing it. Error Recovery Guide is a software that displays trou­bleshooting information on screen if any scanner error occurs.
4. Select a language to use for the installation in the <Choose Setup Language> window and click [OK].
5. Install the application following the instructions in the window.
7
6. When the [InstallShield Wizard Complete] screen displays, click [Finish].
Image Processing Software Option
(Trial)
ATTENTION
This window is not displayed aou­tomatically when the "Auto play" set­ting of your computer is deactivated. In this case, please run "Auto play.exe" of this CD-ROM directly using the "Explore" or "My computer".
2. Select the language and Click [OK] button.
To install the image processing software option (trial version) , please refer to the "Image Processing Software Option User's Guide".
Adobe
®
Acrobat
®
Install Adobe Acrobat from the "Adobe Acrobat 7.0 CD-ROM" provided with this scanner.
ATTENTION
HINT
Adobe Acrobat 7.0 Standard is not supported by Microsoft Windows 95, Microsoft Windows 98/98SE, Microsoft Windows NT4.0, Microsoft Windows Me.
Adobe Acrobat is required for display­ing the manuals stored in the CD­ROM. * Installation of Adobe Acrobat 7.0 is not necessary if it has already been installed in your PC.
3. Select "Install Adobe Acrobat 7.0 Standard".
4. Click the [Next] button. The set up window appears.
1. Insert the "Adobe Acrobat 7.0 CD-ROM" into the CD-ROM drive.
The "Adobe Acrobat 7.0 Standard - Setup" win-
dow appears.
fi-5110C Image Scanner Getting Started 8
5. Follow the instructions to install the software.
HINT
Select "How to install" on the "Adobe Acrobat 7.0 Standard" window to learn more about Adobe Acrobat 7.0 installa­tion. Refer to "Adobe Acrobat Help" about how to use Adobe Acrobat7.0.
ATTENTION
Support and User registration for Adobe products: Refer to the technical support informa­tion stored in the [Customer Support] folder on Adobe Acrobat 7.0 Standard CD-ROM. (Note that free person-to­person support is not available for this bundled product.)
ATTENTION
Notes for using Adobe Acrobat 7.0 When scanning a paper document and converting the image to PDF using Acrobat 7.0, unexpected images may be output when:
1. Setting "Edge Shadow Removal" in Acrobat, and setting "Digital Endorser" or "Black Background" options in the TWAIN driver at the same time. Letter strings embed­ded in the image or the background may be missed. Solution 1: Set "Edge shadow removal" to "OFF" or set any option other than "Adaptive" for "Color/Grayscale" and/or "Mono­chrome" under "Compression" by selecting [File]->[Create PDF]-> [From Scanner...]-> [Image Set­tings...] in Acrobat. Solution 2: Adjust the scanning density in the TWAIN driver.
2. Setting "Adaptive" for "Color/Gray­scale" and/or "Monochrome" under "Compression" in Acrobat and scanning in a resolution lower than the resolution recommended for Acrobat. Solution: Set OPTION to some­thing other than "Adaptive" under "Compression."
3. Scanning a document longer than the double letter (11x17) or A3 size, when setting "Overscan" in the TWAIN driver, the scan may fail. Solution: When scanning a double letter (11x17) or A3 size of docu­ment, do not set "Overscan" in TWAIN driver.
*As for detailed usage and information of Acrobat, refer to "Create a PDF file from a scanned document" in Acrobat Help.

2.2 Installing the Scanner

After the computer has been restarted, connect the scan­ner.
1. Place the scanner at its installation site.
For details on the scanner's dimensions and required installation space, refer to "fi-5110C Operator’s Guide" "9.2 Installation Specifications" in the Setup CD-ROM.
2. Attach the ADF Paper Chute.
Hold the ADF paper chute and insert its tabs into the corresponding slots in the scanner as shown in the figure below. The Side guides of the ADF paper chute have to face up.
ADF paper chute
Tab
Side guide
9
3. Connect the AC adapter.

2.3 Connecting the USB Cable

ATTENTION
Use only the AC adapter provided by the manufacturer.
1) Connect the AC cable to the AC adapter.
2) Connect the AC adapter connector to the scanner’s DC inlet.
Follow the procedure below to connect the USB cable.
1. Connect the USB interface cable to the USB interface connector.
2. Connect the other end of the USB interface cable to the PC.
ATTENTION
Be sure to use the USB cable which
comes as an accessory with this scanner. Correct operation with commercially available cables is not guaranteed.
When connecting to an USB hub,
use the first stage USB hub that is closest to the computer. If you use the second or later hub stages, the scanner may not operate correctly.
3) Plug the AC cable into the outlet.
3. Press the power button to turn ON the scanner.
Your scanner will be automatically detected.
For Windows 98:
HINT
The Function Number Display and the LED may flash for an instant when plugging the AC cable into the scanner.
When a request for inserting the CD-ROM for Windows 98 appears, insert it into the CD drive and click the [OK] button.
For Windows 2000:
When [Digital Signature not Found] appears, click [Yes].
The installation of the scanner is completed.
fi-5110C Image Scanner Getting Started 10

2.4 Confirming Installation

To confirm whether the installation was successful, per­form a scanning operation with an application that com­plies with either the TWAIN regulations, such as ScandAll 21 or the ISIS regulations such as QuickScan
TM
.
Pro
Confirming with ScandAll 21
1. Load the documents on the scanner.
For details on loading documents, refer to "2.2 Load­ing Documents on the ADF for Scanning" in the fi­5110C Operator's Guide on the Setup CD-ROM.
2. Start ScandAll21.
6. Set scanning resolution, document size, etc. on the [TWAIN driver] window (for setting details of scanning) and click the [Scan] button.
Select [Start] - [Programs] - [Scanner Utility for Microsoft Windows] - [ScandAll 21].
3. Specify the scanner (that you will use)
Select [Select Source...]from the [Scan] menu of ScandAll 21.
4. Select "FUJITSU fi-5110Cdj" on the dialog box.
5. Select [To View...] from the [Scan] menu.
HINT
For details on [TWAIN driver], refer to the "FUJITSU TWAIN32 Scanner Driver User’s Guide" provided in the Setup CD-ROM.
7. Documents are scanned, and the scanned images are displayed on the [ScandAll 21] win­dow.
If the scanning completes without any trouble, the installation performed successfully.
11
For details on various types of scanning, refer to the "fi-5110C Operator’s Guide" on the Setup CD-ROM.
Confirming with QuickScan Pro™
1. Load the documents on to the scanner.
For details on loading documents, refer to "2.2 Load­ing Documents on the ADF for Scanning" in the fi­5110C Operator's Guide on the Setup CD-ROM
.
2. Start QuickScan Pro™.
From the [Start] menu, select [Programs]-[Quick­Scan]-[QuickScan].
3. Select [Select Scanner...] from [Scan] menu in QuickScan Pro™.
And, select fi-5110C from the list of [Scanner:], and then click the [OK] button.
4. Select [Preview Settings...] from the [Scan] menu. Set the scan resolution, paper size and other scanning requirements, and then click [OK].
HINT
Refer to "QuickScan Overview" or "QuickScan Help" for information about QuickScan Pro™ functions and opera­tions. On the [Start] menu, point to [Programs]-[QuickScan] and click the file.
5. Select [Preview Scan] from the [Scan] menu. And then the document is scanned.
If the scanning completes without any trouble, the installation performed successfully.
fi-5110C Image Scanner Getting Started 12

Appendix 1 TROUBLESHOOTING

Troubleshooting checklist
Symptom Check this item Remedy
Scanner does not turn on.
Scanning does not commence.
Vertical lines appear in the printed image.
The scanned printed image appears shifted or distorted.
Quality of the scanned image is not satisfactory.
Have you pressed the power button on?
Are the AC cable and AC adapter properly connected to the scan­ner?
Are you using the correct AC cable and AC adapter supplied with the scanner from the manufacture?
Are the documents loaded properly on to the ADF paper chute?
Is the ADF closed completely? Close the ADF completely.
Is the USB cable cable connected securely?
Does the Function Number display indicates an alarm or an error?
The alarm status remain displayed even after the scanner has been turned off and on again?
Is the glass dirty? Clean the glass as instructed in the Opera-
Have the documents been loaded correctly?
Is the glass clean? Clean glass and otther dirty locations
Push the power button in to turn the scan­ner.
Correctly connect the AC cable and the AC adapter.
Disconnect the AC cable and the AC adapter from the scanner, then connect them again. If this does not restore the power supply, contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider.
You must use the AC adapter and cable supplied with your scanner by the manufacture. Please get the correct AC adapter and cable to connect to your scan­ner.
Realign and reload the documents on to ADF paper chute.
Connect the cable. (When a USB hub is used, check the hub's power supply.)
When the Function Number display indi­cates an alarm or an error, refer to "Chap­ter 6 TROUBLESHOOTING" in the fi­5110C Operator’s Guide for removing the alarm or the error.
Turn off and on the power button. If this does not eliminate the alarm status, contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider.
tor's Guide "4. Daily Care".
Reload the documents correctly.
around glass and ADF.
AP-1
Symptom Check this item Remedy
Paper frequently multi feeds.
Paper does not feed (pick error occurs fre­quently, or document stops midway).
Have the document requirements of the fi-5110C Operator’s Guide’s "Document Quality" and the "multi feed Detection Conditions" of chap-
ter 7 been satisfied?
Are the documents placed properly in the ADF paper chute?
Is the stack of document thicker than 5 mm?
Is the Pad ASSY dirty? Clean the Pad ASSY. Refer to Operator's
Is the Pad ASSY worn out? Replace the Pad ASSY. Refer to Opera-
Have the document requirements of the fi-5110C Operator’s Guide’s "Document Quality" and the "Multi Feed Detection Conditions" of
chapter 7 been satisfied?
Use document conditions that meet the "Document Quality" and the "Multi Feed Detection Conditions" in chapter 7 of the fi­5110C Operator’s Guide.
Fan the documents before scanning. Cor­rectly align the document stack and load them on the ADF paper chute. Refer to "2.2 Installing the Scanner" on page 9 for details.
Reduce the number of sheets of the stack to a thickness of 5 mm or less.
Guide in "Chapter 4 Daily Care".
tor's Guide in "5.2. Replacing the Pad ASSY".
Use document conditions that meet the "Document Quality" and the "Multi Feed Detection Conditions" in the chapter 7 of the fi-5110C Operator’s Guide.
Are the scanned images elongated?
Is there a shadow on the top or bottom edge of the scanned image?
Is the Pick roller dirty? To clean the pick roller, refer to Operator's
Guide in "Chapter 4 Daily Care".
Is the Pick roller worn out? Change the Pick roller. Refer to Operator's
Guide in "5.3. Replacing the Pick Roller".
Is there any dirt or dust in the docu­ment feed path?
Are the Feed rollers dirty? Clean the Feed rollers. Refer to Operator's
Have you adjusted the scan scale? Select "Scanners and Cameras" in the con-
Are the Feed rollers dirty? Clean the Feed rollers. Refer to Operator's
Is the offset adjusted? On [Scanners and Cameras] in the control
Remove any dirt or dust from the docu­ment feed path.
Guide in "Chapter 4 Daily Care".
trol panel, then click the [Device Set] tab to adjust scale.
Guide in "Chapter 4 Daily Care".
panel, adjust the [Sub-scan Setting] (in case there is a shadow in the top edge) or adjust the [Bottom] (in case there is a shadow in the bottom edge).
fi-5110C Image Scanner Getting Started AP-2
Temporary error
Device alarm (Non-Temporary error)
Indication Meaning
U1 Paper feed error
U2 Multi Feed error
U4 The ADF has been opened during
scanning.
To troubleshoot the indicated errors above:
"U1" error
Remove all jammed documents. Confirm that the documents meet the paper condi­tions for scanning. Refer to fi-5110C Operator’s Guide "7.2 Document Quality" on the Setup CD-ROM.
"U2" error
Remove all jammed documents. Confirm that the documents are within the required paper preconditions for scanning. Refer to fi-5110C Operator’s Guide "7.2 Document Quality" on the Setup CD-ROM.
Indication Meaning
E2 Trouble in the optical system (front).
E3 Trouble in the optical system (back).
E4 The motor’s fuse has blown out.
E6 Trouble with the operator panel.
E7 Trouble occurred with the EEPROM.
E9 An error in the image memory.
Ec An alarm in the memory.
When you encounter any alarm on the display, turn the scanner off and on. If the alarm is still displayed on the Function Number display, contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider.
"U4" error
Close the ADF cover completely. For the details, refer to "6 TROUBLESHOOTING" in the "fi­5110C Operator's Guide" on the Setup CD-ROM.
AP-3

Appendix 2 DAILY CARE

When operating the scanner, the
WARNING
ADF’s inside glass becomes very hot. Before you clean inside the scanner, turn off its power and unplug the AC adapter from the outlet. Wait for at least 15 minutes.
Do not turn off the scanner when you clean the Feed rollers or Eject rollers.
Cleaning Materials
Cleaning
Materials
Cleaner F1 (or isopropyl alcohol)
Lint-free dry cloth
Parts
Number
CA99501­0013
Commercially available one
Remarks
1 bottle Moisten the cloth with this fluid and wipe the scanner clean.(*)
Parts to Clean and When
Part to clean Standard Cleaning Cycle
Pad ASSY Clean these parts after every
Pick roller
Feed rollers
Plastic rollers
Glass
ATTENTION
The scanner must be cleaned frequently if you scan any of the following type of paper sheets:
Documents of coated paper
Documents that are almost completely
Chemically treated documents such as
Documents containing a large amount
Handwritten documents
1,000 scans.
covered with printed text or graphics
carbonless paper
of calcium carbonate
* For details about cleaning materials, contact the
FUJITSU scanner dealer where you purchased the scanner.
Cleaning Method
The ADF must be cleaned with a lint-free cloth moistened with the Cleaner F1.
ATTENTION
Do not use aerosol sprays to clean the scanner. Aerosol sprays can blow dirt and dust inside the scanner, resulting in scanner failure or malfunction.
For details on the cleaning the ADF, refer to "Chapter 4
Daily Care
" in fi-5110C Operator’s Guide in the Setup
CD-ROM".
fi-5110C Image Scanner Getting Started AP-4

Appendix 3 REPLACING CONSUMABLES

During its operation, the inside
WARNING
glass of the ADF becomes very hot . Before replacing the consumables, turn the scanner off and unplug the AC adapter from the outlet. Wait at least 15 minutes.
Consumables and Replacement Cycles
Below are specifications of consumable items and their recommended replacement cycles.
Standard
Replacement
Cycle
Description
Parts
Number
The illustration below demonstrates the locations of the replacement parts. Refer to "Chapter 5 Replacing Consumables" fi-5110C Operator’s Guide on the Setup CD-ROM.
Replacing the Pad ASSY
Replacing the Pick Roller
Pad ASSY PA03360-
0002
Pick roller PA03360-
0001
To purchase consumables, contact the store where you purchased the scanner or an authorized FUJITSU scan­ner service provider.
The replacement cycles above are rough guidelines when using A4 or Letter woodfree or wood containing
paper 64 g/m type of paper and how frequently the scanner is used and cleaned.
ATTENTION
2
(17 lb). This cycle varies according to the
Use only the consumables specified by PFU Limited.
After 50,000 scans or one year
After 100,000 scans or one year
Pick Roller Bushing
Pick Roller Shaft
AP-5
Pick Roller Shaft
Pick Roller
fi-5110C Image Scanner Getting Started
P3PC-1072-03EN
Date of issuance: June, 2006
Issuance responsibility: PFU LIMITED
Printed in China
z Copying of the contents of this manual in whole or in part and
copying of the scanner application is forbidden under the copyright law.
z The contents of this manual are subject to change without notice. z PFU LIMITED. is not liable whatsoever for any damages resulting
from use of this scanner and procedures described in this manual, profit due to defects, and any claims by a third party.
Loading...