Thank you for purchasing the fi-5110C Duplex Color
Scanner.
This document describes how to handle fi-5110C
Duplex Color Scannerand basic operation methods.
Before you start using fi-5110C Duplex Color Scanner,
be sure to thoroughly read this manual to ensure correct
use.
ATTENTION
The use of a shielded interface cable
is required to comply with the Class B
limits of Part 15 of FCC rules.
The length of the AC cable must be 2
meters (6.6 feet) or less.
The "Operator’s Guide" is stored on the Setup Disk.
The guide provides useful and detailed information on
Operations when you would like to using advanced features, daily maintenance of the scanner, replacement of
consumables.Please also read the Operator’s Guide for
your reference.
■ Regulatory Information
FCC declaration
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation. This equipment generates,
uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not
occur in a particular installation. If this equipment
does cause harmful interference to radio or
television reception, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
•Reorient or relocate the receiving antenna.
Canadian DOC Regulations
This digital apparatus does not exceed the Class B
limit for radio noise emissions from digital
apparatus set out in the Radio interference
Regulations of the Canadian Department of
Communications.
This Class B digital apparatus complies with
Canadian ICES-003.
Le présent appareil numérique n'émet pas de
parasites radioélectriques dépassant les limites
applicables aux appareils numériques de la classe
B et prescrites dans le Règlement sur le brouillage
radioélectrique dictées par le Ministère des
Communications du Canada.
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
Bescheimigung des Herstellers /
Importeurs
Für den fi-5110C wird folgendes bescheinigt:
•In Übereinsstimmung mit den Bestimmungen
der EN45014(CE) funkentstört
•Maschinenlärminformationsverordnung 3.
GPSGV: Der höchste Schalldruckpegel beträgt
70 dB (A) oder weniger, gemäß EN ISO 7779.
•Increase the separation between the equipment
and receiver.
•Connect the equipment into an outlet on a circuit
different from that to which the receiver is
located.
•Consult your dealer or an experienced radio/TV
technician.
FCC warning: Changes or modifications not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
ii
International ENERGY STAR® Program
As an ENERGY
®
STAR
LIMITED has
determined that this
product meets the
ENERGY STAR
guidelines for energy
efficiency.
The International
Equipment Program is an international program
that promotes energy saving through the
Partner, PFU
®
ENERGY STAR
®
Office
penetration of energy efficient computers and
other office equipment. The program backs the
development and dissemination of products with
functions that effectively reduce energy
consumption. It is an open system in which
business proprietors can participate voluntarily.
The targeted products are office equipment such
as computers, monitors, printers, facsimiles,
copiers, scanners, and multifunction devices.
Their standards and logos are uniform among
participating nations.
Use in High-safety Applications
This product has been designed and manufactured
on the assumption that it will be used in office,
personal, domestic, regular industrial, and
general-purpose applications. It has not been
designed and manufactured for use in applications
(simply called "high-safety applications" from
here on) that directly involve danger to life and
health when a high degree of safety is required,
for example, in the control of nuclear reactions at
nuclear power facilities, automatic flight control
of aircraft, air traffic control, operation control in
mass-transport systems, medical equipment for
sustaining life, and missile firing control in
weapons systems, and when provisionally the
safety in question is not ensured. The user should
use this product with adopting measures for
ensuring safety in such high-safety applications.
PFU LIMITED assumes no liability whatsoever
for damages arising from use of this product by
the user in high-safety applications, and for any
claims or compensation for damages by the user
or a third party.
About the Use of Mercury
Lamp(s) inside this product contain
mercury and must be recycled or
g
H
To avoid unexpected injury, read the following
carefully.
Doing the following actions may result in serious
personal injuries:
disposed of according to local, state,
or federal laws.
Trademarks
Microsoft, Windows, and Windows NT are
registered trademarks of Microsoft Corporation in
the United States and/or other countries.
ISIS and QuickScan are trademarks or registered
trademarks of EMC Corporation in the United
States.
Adobe, the Adobe logo, and Acrobat are either
registered trademarks of Adobe Systems
Incorporated in the United States and/or other
countries.
Other product names are the trademarks or
registered trademarks of the respective companies.
How Trademarks Are Indicated In
This Manual
References to operating systems (OS) and
applications are indicated as follows:
Windows 95
Windows 98
Windows Me
Windows NT 4.0
Windows 2000
Windows XP
Microsoft
operating system
Microsoft
operating system.
Microsoft
Millennium Edition operating
system.
Microsoft
Server operating system,
Microsoft
Workstation operating system.
Microsoft
Professional operating system.
Microsoft
Professional operating system,
Microsoft
Home Edition operating system.
Where there is no distinction between the different
versions of the above operating system, the
general term "Windows " is used.
Adobe
Acrobat 7.0
Adobe® Acrobat® 7.0 Standard
®
Windows® 95
®
Windows® 98
®
Windows®
®
Windows® NT 4.0
®
Windows® NT 4.0
®
Windows® 2000
®
Windows® XP
®
Windows® XP
•Do not put the substance contained in the lamp
in your mouth as it has mercury.
•Do not breathe the chemical liquid contained in
the scanner lamps.
•Do not incinerate, crush, or shred the lamps or
scanner parts.
fi-5110C Image Scanner Getting Started iii
Manufacturer
PFU LIMITED
International Sales Dept., Imaging Business
Division, Products Group
Solid Square East Tower, 580 Horikawa-cho,
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,
Japan
Phone : (81-44) 540-4538
This symbol alerts operators to
particularly important information. Be
sure to read this information.
This symbol alerts operators to helpful
advice regarding operation.
■ Note, Liability
BEFORE USING THIS PRODUCT, PLEASE
READ THIS MANUAL CAREFULLY. IF THIS
PRODUCT IS NOT USED CORRECTLY,
UNEXPECTED INJURY CAN OCCUR TO
USERS OR BYSTANDERS.
Keep this manual in a safe place so that it can be
easily referred to during use of this product.
While all efforts have been made to ensure the
accuracy of all information in this manual, PFU
assumes no liability to any party for any damage
caused by errors or omissions or by statements of
any kind in this manual, its updates or
supplements, whether such errors are omissions or
statements resulting from negligence, accidents,
or any other cause. PFU further assumes no
liability arising from the application or use of any
product or system described herein; nor any
liability for incidental or consequential damages
arising from the use of this manual. PFU disclaims
all warranties regarding the information contained
herein, whether expressed, implied, or statutory.
Warning Indications Used In This
A TRIANGLE symbol indicates that special
care and attention is required.
The drawing inside the triangle shows the
specific caution.
A CIRCLE with a diagonal line inside
shows action which users may not perform.
The drawing inside or under the circle
shows the specific action that is not
allowed.
Outline characters on a colored
background show instructions users should
R
follow.
It may also include a drawing that shows
the specific instruction.
Warning Label
The glass surface inside the ADF becomes
hot during the operation. Be careful not to
touch the glass surface inside the ADF.
ATTENTION
Do NOT remove from the scanner,
stain or scratch the warning labels.
Manual
WARNING
CAUTION
iv
This indication alerts operators
to an operation that, if not strictly
observed, may result in severe
injury or death.
This indication alerts operators
to an operation that, if not strictly
observed, may result in safety
hazards to personnel or damage
to equipment.
Screen Examples In This Manual
The screen examples in this manual are subject to
change without notice in the interest of product
improvement. If the actual displayed screen
differs from the screen examples in this manual,
operate by following the actual displayed screen
while referring to the User's Manual of the scanner
application you are using.
The screenshots in this manual were captured
from FUJITSU TWAIN32 scanner driver,
ScandAll 21 Image Capturing Utility Software,
FUJITSU ISIS scanner driver, QuickScan™
®
image capturing software and Adobe
Acrobat®.
Wipe any dust from the power plug.
About Maintenance
The user must not perform repairs on this scanner.
Contact the store where you purchased the scanner
or an authorized FUJITSU Image Scanner service
provider to have repairs done on this product.
■ Safety Precautions
WARNING
Do not damage the AC cable.
A damaged AC cable may cause fire or
electric shock. Do not place heavy objects
on AC cables, or pull, bend, twist, heat,
damage or modify AC cables.
Do not use damaged AC cables or power
plugs, or install any cables or power plugs
to loose wall sockets.
Use only specified AC cables and
connector cables.
Use only specified AC cables and
connector cables. Failure to use the
correct cables might cause electric shock
and/or equipment failure.
Use this scanner only at the
indicated power voltage. Do not
connect to multiple-power strips.
Wipe off any dust from metal parts on the
power plug or metal fittings with a soft, dry
cloth. Accumulated dust can cause fire or
electric shock.
Do not install the device in locations
that hasoil smoke, steam, humidity,
and dust.
Do not install the scanner in locations
subject to oil smoke, steam, humidity, and
dust. Doing so might cause a fire or
electric shock.
Turn the scanner OFF if it is damaged.
If the scanner is damaged for any reason,
turn the scanner off and unplug the power
cable. Contact the store where you
purchased the scanner.
Do not put liquids inside the scanner.
Do not insert or drop metal objects in to the
scanner. Do not scan wet documents or
documents with paper clips or staples. Do
not splash or allow the scanner to get wet.
If foreign objects (water, small metal
objects, liquids, etc.) get inside the scanner,
immediately turn off the scanner and disconnect the power plug from the power outlet. Then, contact the store where you
bought the scanner or the Maintenance Service Center. Pay particular attention to this
warning in households where there are
small children.
Use this scanner only at the indicated
power voltage and current. Improper
power voltage and current might cause
fire or electric shock. Do not connect to
multiple-power strips.
Do not touch the AC cable with wet
hands.
Do not touch the power plug with wet
hands. Doing so might cause electric
shock.
fi-5110C Image Scanner Getting Started v
Do not touch the inside of the
scanner unless necessary.
Do not take apart or modify the scanner.
The inside of the scanner contains highvoltage components. Touching these
components might cause electric shock or
fire.
Do not use the scanner if you smell a
Avoid any contact when scanner is in
strange odor.
If you detect heat coming from the device or
detect other problems such as smoke,
strange smells or noises, immediately turn
off the scanner and then disconnect its
power plug. Make sure that any smoke
coming from it has stopped, before
contacting the store where you bought the
scanner or an authorized FUJITSU scanner
service provider.
CAUTION
Do not install the scanner on
unstable surfaces.
Make sure that the scanner is installed on
a flat, level surface and that none of its
parts extend beyond the surface top, such
as a desk or table. Do not install the
scanner on unstable surfaces. Install the
scanner on a level surface that is free of
vibration to prevent it from falling.
Install the scanner on a strong surface that
will support the weight of the scanner and
other devices.
Do not block the ventilation ports.
Do not block the ventilation ports. Blocking
the ventilation ports generates heat inside
of scanner, which may resultin fire or
scanner failure.
use.
Avoid touching any scanner mechanism
during scanning since this may cause
injuries.
Do not use the scanner immediately
after moving it from a cold place into
a warm room.
Do not use the device immediately after
moving it from a cold place into a warm
room. Condensation may occur, which
might lead to scanning errors. Let the
device dry about one or two hours before
you use it.
Before moving the scanner,
disconnect the power plug from the
power outlet.
Do not move the scanner with the power
and interface cables connected as this can
damage the cables, which can later cause
fire, electric shock as well as injury.
Before moving the scanner, be sure to
disconnect the power plug from the power
outlet, and all other data cables.
Make sure that the floor is free of any
obstructions.
Protect the scanner from static
electricity.
Do not place heavy objects or climb
on top of the scanner.
Do not place heavy objects on the scanner
or use the scanner's surface top to
perform other work. Improper installation
might cause injuries and equipment
failure.
Firmly insert the power plug.
Firmly insert the power plug as far it can
go into the power outlet.
vi
Install the scanner away from strong
magnetic fields and other sources of
electronic noise. Also, protect the scanner
against any static electricity, which can
cause the scanner to malfunction.
Do not use aerosol sprays near the
scanner.
Do not use aerosol sprays to clean the
scanner. Aerosol sprays can blow dirt and
dust inside the scanner, resulting in scanner
failure or malfunction.
Disconnect the power plug from the
power outlet when the scanner is not
used for a long period of time.
When the scanner is not going to be used
for a long period of time, be sure to
disconnect the power plug from the power
outlet for safety.
Do not install the scanner in direct
sunlight.
Do not install the scanner under direct
sunlight or near heating apparatus. Doing so
might cause excessive heat to build up
inside the scanner, which can cause
scanner trouble or even fire.Install the
scanner in a well-ventilated location.
fi-5110C Image Scanner Getting Started vii
Chapter 1PREPARING THE SCANNER
1.1 Checking the Contents of
the Scanner Package
When you open the scanner package, please handle the
main unit and its attachments carefully.
Make sure it contains all the parts listed in the package
contents list that is included in the package box.
If any parts are missing or defective, contact your sales
representative.
1.2 Names of Parts
This section describes the scanner parts.
■ Front
ADF paper chute
Automatic document
feeder(ADF)
ADF open lever
Side guide
■ Rear
USB Interface
connector
DC inlet
Security
Cable Slot
■ Removable Parts
Parts that can be removed from the scanner are displayed below.
ADF paper chute
Sheet Guide
Stacker
Operator
panel
Pad ASSY
Pick Roller
1
1.3 Operator Panel
The operator panel is located on the right side of the
scanner. This panel is comprised of a Function Number
display, four buttons and a LED.
Function No
display
Function
Send to
Scan
Power button
■ Indications on the Function
Number display
■ 8
Blinks only one time upon turning on the scanner.
■ P
Indicates that the scanner has been turned ON
and is being initialized.
■ 0
Indicates that initialization will soon end.
NameFunction
Function Number
display
ButtonFunctionChanges the Function acti-
Send toLaunches the linked appli-
Scan
Power
button
LED-Lights when the scanner is
*)
About the settings on the launcher, refer to
Indicates the function
Number and error status.
vated by the Send to button
(*).
cation software (*).
Turns the scanner ON and
OFF.
turned ON.
LED
FUJITSU TWAIN32 scanner driver help and the
"fi-5110C Operator’s Guide" in the Setup CDROM.
■ 1
Indicates that initialization has ended successfully.
The scanner is now in "Ready Status".
■ U
Indicates that a temporary error occurred when
documents were being scanned. A number
appearing in alternation following the U (i.e.,
1, 2 and 4) refers to the type of error.
To return the scanner to the ready status ("1"),
press "Scan" or "Send to" button.
■ E
Indicates that a device (hardware) alarm has
occurred during scanning of documents.
"E" and the alarm Number (2 to 9 and c) will
appear alternately.
To return the scanner to the ready status ("1"),
press "Scan" or "Send to" button.
If this alarm occurs, turn the power off and on
again. If the alarm continues after turning the
power on again, contact your service engineer.
fi-5110C Image Scanner Getting Started 2
Chapter2 INSTALLATION OF THE SCANNER
2.1 Installing the Scanner
Application
Both the scanner driver and image capturing application
software (called "application" hereafter) must be
installed on your PC.
There are two types of drivers for scanner, The
FUJITSU TWAIN 32 Scanner Driver and FUJITSU
ISIS Scanner Driver, as well as two software applications, ScandAll 21 and QuickScan Pro™, are provided
with this product. The following sections describe how
to install each driver and application.
ATTENTION
Please install the scanner driver
before connecting the scanner to your
PC.
If you connect the scanner before
installing the scanner driver, the scanner will not operate correctly.
If you have connected the scanner
beforehand, the "Found New Hardware Wizard" screen appears (this
screen might differ slightly according
to the used OS) . On this screen, click
the [Cancel] button to close the
Wizard screen and install the scanner
driver first.
■ Installing the FUJITSU TWAIN32
Scanner Driver
ATTENTION
1. Turn on your PC and log on to Windows.
ATTENTION
2. Insert the Setup CD-ROM into the CD drive.
⇒ <SETUP DISK START UP SCREEN> appears.
ATTENTION
3. Click [INSTALL PRODUCTS].
Windows XP screenshots are used in
this sectionas examples. The windows and operations may slightly vary
depending on your OS
When using Windows 2000 or Windows XP, log on as a user with
"Administrator" privileges.
This screen may not appear when the
"Autoplay" setting of your PC is OFF.
In this case, run "Install.exe" in this
CD-ROM directly from the "Explorer"
or "My Computer".
.
For FUJITSU TWAIN32 Scanner Driver
■ Preparation
Confirm the following items before installing the application.
• Remove the Setup CD-ROM from its package.
• Uninstall any older version of FUJITSU
TWAIN 32 driver if already installed.
ATTENTION
Uninstall [Scanner Utility for Microsoft
Windows] from [Add/Remove Programs]of the control panel.
3
4. Click [TWAIN Driver] on the window below.
5. Error Recovery Guide Installation window
appears.
Error Recovery Guide is a software that displays
troubleshooting information on screen when any
scanner error occurs. Although this software’s
installation is highly recommended, the performance of the scanner would not be affected if
not installed.
8. When the [InstallShield Wizard Complete] window appears, click [Finish].
9. Your computer will be restarted.
Do not remove the Setup CD-ROM from the CD
drive until your PC has completely restarted.
Installation of the scanner driver is completed.
■ Installing ScandAll 21
ATTENTION
When you select [Yes] for installing
the Error Recovery Guide, [Choose
Setup Language] window appears.
Select a language and follow the
instructions on the window. Error
Recovery Guide will automatically
continue finishing its installation.
Please wait until the installation of
TWAIN driver automatically starts.
6. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
"Scandall 21" is an image capturing software that complies with the TWAIN standard. The FUJITSU TWAIN
32 scanner driver enables you to capture images with a
FUJITSU image scanner fi-series product.
ATTENTION
When using Windows 2000 or Windows XP, log on as a user with
"Administrator" privileges.
1. Insert the Setup CD-ROM into the CD drive.
⇒ <SETUP DISK START UP SCREEN> appears.
2. Click [INSTALL PRODUCTS].
7. Follow the instructions on the window to install
the application.
fi-5110C Image Scanner Getting Started 4
3. Click [ScandAll 21] on the window below.
For FUJITSU ISIS Scanner Driver
■ Preparation
Remove the Setup CD-ROM from its package.
■ Installing the FUJITSU ISIS
Scanner Driver
4. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
5. Install the application following the instructions
on the window.
6. When the [InstallShield Wizard Complete] window appears, click [Finish].
ATTENTION
Windows XP screenshots are used in
this section as examples. The windows and operations may vary slightly
depending on your OS.
1. Turn your PC on and log on to Windows.
ATTENTION
When using Windows 2000 or Windows XP, log on as a user with
"Administrator" privileges.
2. Insert the "Setup CD-ROM" into the CD drive.
⇒ <SETUP DISK START UP SCREEN> appears.
ATTENTION
This screen may not appear when the
"Autoplay" setting of your PC is OFF.
In this case, run "Install.exe" in this
CD-ROM directly from the "Explorer"
or "My Computer".
5
ATTENTION
3. Click [INSTALL PRODUCTS].
For finishing the installation, it may be
necessary to restart your computer.
Follow the instructions on the window.
4. Click [ISIS Driver] on the window below.
■ Installing QuickScan Pro™
"QuickScan Pro™" is an image capturing software that
complies with the ISIS standard. The FUJITSU ISIS
scanner driver enables you to capture images with a
FUJITSU image scanner fi-series product
5. Error Recovery Guide Installation window
appears.
Error Recovery Guide is a software that displays
troubleshooting information on screen if any
scanner error occurs. Although this software’s
installation is highly recommended, the performance of the scanner would not be affected if
not installed.
ATTENTION
When you select [Yes] for installing
Error Recovery Guide, the [Choose
Setup Language] window appears.
Select a language and follow the
instructions on the window. The Error
Recovery Guide will automatically
continue finishing its installation.
Please wait until the installation of
ISIS driver automatically starts.
ATTENTION
• When using Windows 2000 or Win-
dows XP, log on as a user with
"Administrator" privileges.
• If an older version of QuickScan has
already been installed on your PC,
uninstall it before installing this version.
1. Insert the Setup CD-ROM into a CD drive.
⇒ <SETUP DISK STARTUP SCREEN> appears.
2. Click [INSTALL PRODUCTS].
6. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
7. Follow the instructions on the window to install
the application.
8. When the [InstallShield Wizard Complete]
window appears, click [Finish].
9. Your computer will be restarted. Do not remove
the Setup CD-ROM from the CD drive until your
PC has completely restarted.
Now the installation of the scanner driver is completed.
3. Click [QuickScan PRO (Trial)] on the window
below.
4. Continue to install the application following the
instructions on the window.
fi-5110C Image Scanner Getting Started 6
5. Enter the required information, then click
[Next >] button.
1. Insert the Setup CD-ROM in your CD drive.
The <SETUP DISK STARTUP SCREEN> will
appear.
2. Click [Install Products].
3. Click [Error Recovery Guide] on the next screen.
ATTENTION
"QuickScan Pro™" included in the
Setup CD-ROM is an evaluation version. For further use after the expiration of its evaluation period of up to 30
launches, it is necessary to purchase
a fully functional version of QuickScan
Pro™. (When you install the evaluation version, do not change the Serial
Number already displayed.)
6. Install the application following the instructions
on the window.
Error Recovery Guide
If you did not install together the Error Recovery Guide
with the driver, please proceed with the procedures
given below for installing it.
Error Recovery Guide is a software that displays troubleshooting information on screen if any scanner error
occurs.
4. Select a language to use for the installation in
the <Choose Setup Language> window and
click [OK].
5. Install the application following the instructions
in the window.
7
6. When the [InstallShield Wizard Complete]
screen displays, click [Finish].
Image Processing Software Option
(Trial)
ATTENTION
This window is not displayed aoutomatically when the "Auto play" setting of your computer is deactivated.
In this case, please run "Auto
play.exe" of this CD-ROM directly
using the "Explore" or "My computer".
2. Select the language and Click [OK] button.
To install the image processing software option (trial
version), please refer to the "Image Processing Software
Option User's Guide".
Adobe
®
Acrobat
®
Install Adobe Acrobat from the "Adobe Acrobat 7.0
CD-ROM" provided with this scanner.
ATTENTION
HINT
Adobe Acrobat 7.0 Standard is not
supported by Microsoft Windows 95,
Microsoft Windows 98/98SE,
Microsoft Windows NT4.0, Microsoft
Windows Me.
Adobe Acrobat is required for displaying the manuals stored in the CDROM.
* Installation of Adobe Acrobat 7.0 is
not necessary if it has already been
installed in your PC.
3. Select "Install Adobe Acrobat 7.0 Standard".
4. Click the [Next] button. The set up window
appears.
1. Insert the "Adobe Acrobat 7.0 CD-ROM" into the
CD-ROM drive.
⇒ The "Adobe Acrobat 7.0 Standard - Setup" win-
dow appears.
fi-5110C Image Scanner Getting Started 8
5. Follow the instructions to install the software.
HINT
Select "How to install" on the "Adobe
Acrobat 7.0 Standard" window to learn
more about Adobe Acrobat 7.0 installation. Refer to "Adobe Acrobat Help"
about how to use Adobe Acrobat7.0.
ATTENTION
Support and User registration for
Adobe products:
Refer to the technical support information stored in the [Customer Support]
folder on Adobe Acrobat 7.0 Standard
CD-ROM. (Note that free person-toperson support is not available for this
bundled product.)
ATTENTION
Notes for using Adobe Acrobat 7.0
When scanning a paper document
and converting the image to PDF
using Acrobat 7.0, unexpected images
may be output when:
1. Setting "Edge Shadow Removal" in
Acrobat, and setting "Digital
Endorser" or "Black Background"
options in the TWAIN driver at the
same time. Letter strings embedded in the image or the background
may be missed.
Solution 1: Set "Edge shadow
removal" to "OFF" or set any option
other than "Adaptive" for
"Color/Grayscale" and/or "Monochrome" under "Compression" by
selecting [File]->[Create PDF]->
[From Scanner...]-> [Image Settings...] in Acrobat.
Solution 2: Adjust the scanning
density in the TWAIN driver.
2. Setting "Adaptive" for "Color/Grayscale" and/or "Monochrome" under
"Compression" in Acrobat and
scanning in a resolution lower than
the resolution recommended for
Acrobat.
Solution: Set OPTION to something other than "Adaptive" under
"Compression."
3. Scanning a document longer than
the double letter (11x17) or A3 size,
when setting "Overscan" in the
TWAIN driver, the scan may fail.
Solution: When scanning a double
letter (11x17) or A3 size of document, do not set "Overscan" in
TWAIN driver.
*As for detailed usage and information
of Acrobat, refer to "Create a PDF file
from a scanned document" in Acrobat
Help.
2.2 Installing the Scanner
After the computer has been restarted, connect the scanner.
1. Place the scanner at its installation site.
For details on the scanner's dimensions and required
installation space, refer to "fi-5110C Operator’s
Guide" "9.2 Installation Specifications" in the Setup
CD-ROM.
2. Attach the ADF Paper Chute.
Hold the ADF paper chute and insert its tabs into the
corresponding slots in the scanner as shown in the
figure below.
The Side guides of the ADF paper chute have to face
up.
ADF paper chute
Tab
Side guide
9
3. Connect the AC adapter.
2.3 Connecting the USB Cable
ATTENTION
Use only the AC adapter provided by
the manufacturer.
1) Connect the AC cable to the AC adapter.
2) Connect the AC adapter connector to the
scanner’s DC inlet.
Follow the procedure below to connect the USB cable.
1. Connect the USB interface cable to the USB
interface connector.
2. Connect the other end of the USB interface
cable to the PC.
ATTENTION
• Be sure to use the USB cable which
comes as an accessory with this
scanner.
Correct operation with commercially
available cables is not guaranteed.
• When connecting to an USB hub,
use the first stage USB hub that is
closest to the computer. If you use
the second or later hub stages, the
scanner may not operate correctly.
3) Plug the AC cable into the outlet.
3. Press the power button to turn ON the scanner.
Your scanner will be automatically detected.
For Windows 98:
HINT
The Function Number Display and the
LED may flash for an instant when
plugging the AC cable into the scanner.
When a request for inserting the CD-ROM for
Windows 98 appears, insert it into the CD drive and
click the [OK] button.
For Windows 2000:
When [Digital Signature not Found] appears, click
[Yes].
The installation of the scanner is completed.
fi-5110C Image Scanner Getting Started 10
2.4 Confirming Installation
To confirm whether the installation was successful, perform a scanning operation with an application that complies with either the TWAIN regulations, such as
ScandAll 21 or the ISIS regulations such as QuickScan
TM
.
Pro
■ Confirming with ScandAll 21
1. Load the documents on the scanner.
For details on loading documents, refer to "2.2 Loading Documents on the ADF for Scanning" in the fi5110C Operator's Guide on the Setup CD-ROM.
2. Start ScandAll21.
6. Set scanning resolution, document size, etc. on
the [TWAIN driver] window (for setting details of
scanning) and click the [Scan] button.
Select [Start] - [Programs] - [Scanner Utility for
Microsoft Windows] - [ScandAll 21].
3. Specify the scanner (that you will use)
Select [Select Source...]from the [Scan] menu of
ScandAll 21.
4. Select "FUJITSU fi-5110Cdj" on the dialog box.
5. Select [To View...] from the [Scan] menu.
HINT
For details on [TWAIN driver], refer to
the "FUJITSU TWAIN32 Scanner
Driver User’s Guide" provided in the
Setup CD-ROM.
7. Documents are scanned, and the scanned
images are displayed on the [ScandAll 21] window.
If the scanning completes without any trouble, the
installation performed successfully.
11
For details on various types of scanning, refer to the
"fi-5110C Operator’s Guide" on the Setup CD-ROM.
■ Confirming with QuickScan Pro™
1. Load the documents on to the scanner.
For details on loading documents, refer to "2.2 Loading Documents on the ADF for Scanning" in the fi5110C Operator's Guide on the Setup CD-ROM
.
2. Start QuickScan Pro™.
From the [Start] menu, select [Programs]-[QuickScan]-[QuickScan].
3. Select [Select Scanner...] from [Scan] menu in
QuickScan Pro™.
And, select fi-5110C from the list of [Scanner:], and
then click the [OK] button.
4. Select [Preview Settings...] from the [Scan]
menu. Set the scan resolution, paper size and
other scanning requirements, and then click
[OK].
HINT
Refer to "QuickScan Overview" or
"QuickScan Help" for information about
QuickScan Pro™ functions and operations. On the [Start] menu, point to
[Programs]-[QuickScan] and click the
file.
5. Select [Preview Scan] from the [Scan] menu.
And then the document is scanned.
If the scanning completes without any trouble, the
installation performed successfully.
fi-5110C Image Scanner Getting Started 12
Appendix 1TROUBLESHOOTING
■ Troubleshooting checklist
SymptomCheck this itemRemedy
Scanner does not turn
on.
Scanning does not
commence.
Vertical lines appear in
the printed image.
The scanned printed
image appears shifted or
distorted.
Quality of the scanned
image is not satisfactory.
Have you pressed the power
button on?
Are the AC cable and AC adapter
properly connected to the scanner?
Are you using the correct AC cable
and AC adapter supplied with the
scanner from the manufacture?
Are the documents loaded properly
on to the ADF paper chute?
Is the ADF closed completely?Close the ADF completely.
Is the USB cable cable connected
securely?
Does the Function Number display
indicates an alarm or an error?
The alarm status remain displayed
even after the scanner has been
turned off and on again?
Is the glass dirty?Clean the glass as instructed in the Opera-
Have the documents been loaded
correctly?
Isthe glass clean?Clean glass and otther dirty locations
Push the power button in to turn the scanner.
Correctly connect the AC cable and the AC
adapter.
Disconnect the AC cable and the AC
adapter from the scanner, then connect
them again.
If this does not restore the power supply,
contact the store where you purchased the
scanner or an authorized FUJITSU scanner
service provider.
You must use the AC adapter and cable
supplied with your scanner by the
manufacture. Please get the correct AC
adapter and cable to connect to your scanner.
Realign and reload the documents on to
ADF paper chute.
Connect the cable. (When a USB hub is
used, check the hub's power supply.)
When the Function Number display indicates an alarm or an error, refer to "Chapter 6 TROUBLESHOOTING" in the fi5110C Operator’s Guide for removing the
alarm or the error.
Turn off and on the power button.
If this does not eliminate the alarm status,
contact the store where you purchased the
scanner or an authorized FUJITSU scanner
service provider.
tor's Guide "4. Daily Care".
Reload the documents correctly.
around glass and ADF.
AP-1
SymptomCheck this itemRemedy
Paper frequently multi
feeds.
Paper does not feed
(pick error occurs frequently, or document
stops midway).
Have the document requirements
of the fi-5110C Operator’s Guide’s
"Document Quality" and the "multi
feed Detection Conditions" of chap-
ter 7 been satisfied?
Are the documents placed properly
in the ADF paper chute?
Is the stack of document thicker
than 5 mm?
Is the Pad ASSY dirty?Clean the Pad ASSY. Refer to Operator's
Is the Pad ASSY worn out?Replace the Pad ASSY. Refer to Opera-
Have the document requirements
of the fi-5110C Operator’s Guide’s
"Document Quality" and the "Multi
Feed Detection Conditions" of
chapter 7 been satisfied?
Use document conditions that meet the
"Document Quality" and the "Multi Feed
Detection Conditions" in chapter 7 of the fi5110C Operator’s Guide.
Fan the documents before scanning. Correctly align the document stack and load
them on the ADF paper chute. Refer to "2.2
Installing the Scanner" on page 9 for
details.
Reduce the number of sheets of the stack
to a thickness of 5 mm or less.
Guide in "Chapter 4 Daily Care".
tor's Guide in "5.2. Replacing the Pad
ASSY".
Use document conditions that meet the
"Document Quality" and the "Multi Feed
Detection Conditions" in the chapter 7 of
the fi-5110C Operator’s Guide.
Are the scanned images
elongated?
Is there a shadow on the
top or bottom edge of
the scanned image?
Is the Pick roller dirty?To clean the pick roller, refer to Operator's
Guide in "Chapter 4 Daily Care".
Is the Pick roller worn out?Change the Pick roller. Refer to Operator's
Guide in "5.3. Replacing the Pick Roller".
Is there any dirt or dust in the document feed path?
Are the Feed rollers dirty?Clean the Feed rollers. Refer to Operator's
Have you adjusted the scan scale?Select "Scanners and Cameras" in the con-
Are the Feed rollers dirty?Clean the Feed rollers. Refer to Operator's
Is the offset adjusted?On [Scanners and Cameras] in the control
Remove any dirt or dust from the document feed path.
Guide in "Chapter 4 Daily Care".
trol panel, then click the [Device Set] tab to
adjust scale.
Guide in "Chapter 4 Daily Care".
panel, adjust the [Sub-scan Setting] (in
case there is a shadow in the top edge) or
adjust the [Bottom] (in case there is a
shadow in the bottom edge).
fi-5110C Image Scanner Getting Started AP-2
■ Temporary error
■
Device alarm (Non-Temporaryerror)
IndicationMeaning
U1Paper feed error
U2Multi Feed error
U4The ADF has been opened during
scanning.
To troubleshoot the indicated errors above:
• "U1" error
Remove all jammed documents.
Confirm that the documents meet the paper conditions for scanning.
Refer to fi-5110C Operator’s Guide "7.2 Document
Quality" on the Setup CD-ROM.
• "U2" error
Remove all jammed documents.
Confirm that the documents are within the required
paper preconditions for scanning.
Refer to fi-5110C Operator’s Guide "7.2 Document
Quality" on the Setup CD-ROM.
IndicationMeaning
E2Trouble in the optical system (front).
E3Trouble in the optical system (back).
E4The motor’s fuse has blown out.
E6Trouble with the operator panel.
E7Trouble occurred with the EEPROM.
E9An error in the image memory.
EcAn alarm in the memory.
When you encounter any alarm on the display, turn
the scanner off and on. If the alarm is still displayed
on the Function Number display, contact the store
where you purchased the scanner or an authorized
FUJITSU scanner service provider.
• "U4" error
Close the ADF cover completely. For the details,
refer to "6 TROUBLESHOOTING" in the "fi5110C Operator's Guide" on the Setup CD-ROM.
AP-3
Appendix 2DAILY CARE
When operating the scanner, the
WARNING
ADF’s inside glass becomes
very hot.
Before you clean inside the
scanner, turn off its power and
unplug the AC adapter from the
outlet. Wait for at least
15 minutes.
Do not turn off the scanner when
you clean the Feed rollers or
Eject rollers.
■ Cleaning Materials
Cleaning
Materials
Cleaner F1
(or isopropyl
alcohol)
Lint-free dry
cloth
Parts
Number
CA995010013
Commercially available one
Remarks
1 bottle
Moisten the cloth
with this fluid and
wipe the scanner
clean.(*)
■ Parts to Clean and When
Part to cleanStandard Cleaning Cycle
Pad ASSYClean these parts after every
Pick roller
Feed rollers
Plastic rollers
Glass
ATTENTION
The scanner must be cleaned
frequently if you scan any of the
following type of paper sheets:
• Documents of coated paper
• Documents that are almost completely
• Chemically treated documents such as
• Documents containing a large amount
• Handwritten documents
1,000 scans.
covered with printed text or graphics
carbonless paper
of calcium carbonate
* For details about cleaning materials, contact the
FUJITSU scanner dealer where you purchased the
scanner.
■ Cleaning Method
The ADF must be cleaned with a lint-free cloth
moistened with the Cleaner F1.
ATTENTION
Do not use aerosol sprays to clean
the scanner. Aerosol sprays can blow
dirt and dust inside the scanner,
resulting in scanner failure or
malfunction.
For details on the cleaning the ADF, refer to "Chapter 4
Daily Care
" in fi-5110C Operator’s Guide in the Setup
CD-ROM".
fi-5110C Image Scanner Getting Started AP-4
Appendix 3REPLACING CONSUMABLES
During its operation, the inside
WARNING
glass of the ADF becomes very
hot .
Before replacing the
consumables, turn the scanner
off and unplug the AC adapter
from the outlet. Wait at least
15 minutes.
■ Consumables and Replacement
Cycles
Below are specifications of consumable items and
their recommended replacement cycles.
Standard
Replacement
Cycle
Description
Parts
Number
The illustration below demonstrates the locations of the
replacement parts. Refer to "Chapter 5 Replacing
Consumables" fi-5110C Operator’s Guide on the Setup
CD-ROM.
■ Replacing the Pad ASSY
■ Replacing the Pick Roller
Pad ASSYPA03360-
0002
Pick rollerPA03360-
0001
To purchase consumables, contact the store where you
purchased the scanner or an authorized FUJITSU scanner service provider.
The replacement cycles above are rough guidelines
when using A4 or Letter woodfree or wood containing
paper 64 g/m
type of paper and how frequently the scanner is used and
cleaned.
ATTENTION
2
(17 lb). This cycle varies according to the
Use only the consumables specified
by PFU Limited.
After 50,000 scans
or one year
After 100,000
scans or one year
Pick Roller Bushing
Pick Roller Shaft
AP-5
Pick Roller Shaft
Pick Roller
fi-5110C Image Scanner Getting Started
P3PC-1072-03EN
Date of issuance: June, 2006
Issuance responsibility: PFU LIMITED
Printed in China
z Copying of the contents of this manual in whole or in part and
copying of the scanner application is forbidden under the copyright
law.
z The contents of this manual are subject to change without notice.
z PFU LIMITED. is not liable whatsoever for any damages resulting
from use of this scanner and procedures described in this manual,
profit due to defects, and any claims by a third party.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.