Frigidaire PRMC2285AF Service Data Sheet

4 (1)
Frigidaire PRMC2285AF Service Data Sheet

SYSTEM DIAGNOSTIC MODE

Activate:

 

Press and hold + and - buttons for 10 secs. Navigate through tests with +/- buttons

 

Deactivate:

Press and hold + and - buttons for 10 secs.

 

 

 

Display

 

Test

Activation/Deactivation

 

Display

Passing result

--

 

First Screen

--

Turn on all LEDS on main UI, VCZ UI, and external dispenser UI

---

--

 

Second Screen

--

Turn off all LEDS on main UI, VCZ UI, and external dispenser UI

---

2

 

FZR Defrost Heater

Press FREEZE BOOST to change status of load

Heater on when display reads “on”, off when “oF”

Defrost heater shows temp increase before 5 min have passed or

 

 

 

 

FRZ Evap Defrost sensor temp is flashed on display, watch for increase in temperature. May

reaches 45°C cutout

 

 

 

 

take up to max 5 min for evap to warm up or 45°C sensor threshold

 

8

 

Main Water Valve

Press FREEZE BOOST to change status of load

Main valve is activated when “on”, stops when “oF”

Valve is able to turn on and off

11

 

Cube/Crush Solenoid

Press FREEZE BOOST to change status of load

Solenoid activated when “on”, deactivated when “oF”

Solenoid is able to turn on and off

 

 

 

 

DO NOT LEAVE SOLENOID ACTIVATED FOR MORE THAN 1 MINUTE

 

53

 

Water Valve Dispenser + Main

Press FREEZE BOOST to change status of load

Water dispenses when “on”; stops when “oF”

Water is dispensed successfully at dispenser

 

 

Valve

 

Be prepared to collect water at dispenser

 

56

 

IM Water Valve + Main Valve

Press FREEZE BOOST to change status of load

Remove ice tray to collect water into a container to measure water fill

Water is dispensed at ice tray for configured time setting

 

 

 

 

If collecting water into ice tray, perform test 50 first to empty tray.

 

 

 

 

 

Water flows in the tray when “on”, test is correspondent to Ice tray water fill setting;

 

 

 

 

 

automatically goes to “oF” state once configured time has elapsed

 

71

 

FF Defrost Heater

Press FREEZE BOOST to change status of load

Heater on when display reads “on”, off when “oF”

Defrost heater shows temp increase before 5 min have passed or

 

 

 

 

FF Evap Defrost sensor temp is flashed on display, watch for increase in temperature. May

reaches 45°C cutout

 

 

 

 

take up to max 5 min for evap to warm up or 45°C sensor threshold

 

72

 

FFIM Defrost Heater +

Press FREEZE BOOST to change status of load

Heater on when display reads “on”, off when “oF”

Defrost heater shows temp increase before 5 min have passed or

 

 

Fill Tube Heater

 

FFIM Evap Defrost sensor temp is flashed on display, watch for increase in temperature. May

reaches 45°C cutout

 

 

 

 

take up to max 5 min for evap to warm up or 45°C sensor threshold

 

74

 

VCZ Balance Heater

Press FREEZE BOOST to change status of load

Heater on when “on”, off when “oF”; Maximum of 5 minutes on continuous

Defrost heater is successfully turned on and off; temperature increase is

 

 

 

 

 

 

noted in VCZ compartment

91

 

FRZ IM Fill Tube Heater

Press FREEZE BOOST to change status of load

Heater on when “on”, off when “oF”; Maximum of 5 minutes on continuous

Defrost heater is successfully turned on and off; temperature increase is

 

 

 

 

 

 

noted in fill tube area

10

 

Auger Motor

Press FREEZE BOOST to change status of load

FF DOOR MUST BE CLOSED

Auger motor is successfully activated

 

 

 

 

Motor running when “on”, motor stopped when “oF”

 

13

 

FF Light

Press FREEZE BOOST to change status of load

Fresh Food lights come on when “on”, lights turn off when “oF”

All FF lights come on

14

 

VCZ Light

Press FREEZE BOOST to change status of load

VCZ light come on when “on”, light turn off when “oF”

VCZ light turns on

15

 

FRZ Evaporator Fan Motor

Press FREEZE BOOST to change status of load

Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”

Fan will cycle through all 3 speeds and “Lc” or “Ns” or “Np” is not displayed

 

 

 

 

Locked rotor will show “Lc”

 

 

 

 

 

No PWM signal will show “Ns” when fan is stopped (“oF”)

 

 

 

 

 

No 12V signal or ground will show “Np” when fan is “on” or “Mi”

 

17

 

VCZ Fan Motor

Press FREEZE BOOST to change status of load

Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”

Fan will cycle through all 3 speeds successfully

18

 

Condenser Fan

Press FREEZE BOOST to change status of load

Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”

Fan will cycle through all 3 speeds and “LC” or “nS” or “nP” is not displayed

 

 

 

 

Locked rotor will show “LC”

 

 

 

 

 

No PWM signal will show “nS” when fan is stopped (“oF”)

 

 

 

 

 

No 12V signal or ground will show “nP” when fan is “on” or “Mi”

 

20

 

FRZ Light

Press FREEZE BOOST to change status of load

FRZ light comes on when “on”, light turns off when “oF”

FRZ light turns on

38

 

VCC Compressor

Press FREEZE BOOST to change status of load

Compressor is running at max speed when “on”, stopped when “oF”

Compressor successfully turns on

47

 

Ice Chute Heater

Press FREEZE BOOST to change status of load

Chute heater is activated when “on”, deactivated when “oF”

Heater turns on successfully and difference in temperature is felt around

 

 

 

 

 

 

dispenser ice chute

62

 

FFIM Evap Fan Motor

Press FREEZE BOOST to change status of load

Evap fan motor is activated when “on”, deactivated when “oF”

Fan turns on successfully

63

 

Flipper Mullion DC Heater

Press FREEZE BOOST to change status of load

Flipper mullion heater is activated when “on”, deactivated when “oF”

Heater turns on successfully and difference in temperature is felt around

 

 

 

 

 

 

along flipper mullion

66

 

Dispenser Light

Press FREEZE BOOST to change status of load

Dispenser pocket light turns on when “on”, light turns off when “oF”

Dispenser pocket light turns on successfully

70

 

FF Evap Fan Motor

Press FREEZE BOOST to change status of load

Fan runs at 3 speeds; Max speed “on”, medium speed “Mi”, stopped “oF”

Fan will cycle through all 3 speeds and “LC” or “nS” or “nP” is not displayed

 

 

 

 

Locked rotor will show “LC”

 

 

 

 

 

No PWM signal will show “nS” when fan is stopped (“oF”)

 

 

 

 

 

No 12V signal or ground will show “nP” when fan is “on” or “Mi”

 

76

 

VCZ Damper Heater

Press FREEZE BOOST to change status of load

VCZ damper heater activated when “on”, deactivated when “oF”

Heater turns on successfully and difference in temperature is felt around

 

 

 

 

 

 

along VCZ damper

77

 

VCZ Damper Motor

Press FREEZE BOOST to change status of load

FRZ EVAP FAN WILL TURN ON AT MAX SPEED

Damper opens and closes successfully and no air flow is felt when

 

 

 

 

Damper is open when “OP”, closed when “CL”

damper is in closed (“CL”) position

 

 

 

 

Check for airflow when damper is fully open (“OP”) and no air flow when fully closed (“CL”)

 

 

 

 

 

Screen will blink “1” during damper movement

 

 

 

 

 

Any FRZ evap fan motor errors will display alternatively of damper status during test

 

36

 

Ice Chute Door/Flapper Motor

Press FREEZE BOOST to change status of load

When flapper is closed, shows “CL”, when open “OP”

Flapper door opens and closes successfully, “Er” does not show on display

 

 

 

 

During movement of flapper, screen will blink “1”

 

 

 

 

 

Flapper will open/close for 3 cycles and will show “Er” if any failues are detected

 

50

 

FFIM Twist Tray Harvest Test

Press FREEZE BOOST to change status of load

REMOVE ICE BUCKET IN ORDER TO SEE ROTATION OF TRAY

Tray twists successfully and “Er” is not displayed at the end of the cycle

 

 

 

 

Display will show “Go” when tray is in home position (horizontal)

 

 

 

 

 

During rotation, screen will blink “1”

 

 

 

 

 

In case of failure at end of twisting operation, will show “Er”

 

78

 

FFIM Bail Arm/Ice Level Bucket

Press FREEZE BOOST to change status of load

REMOVE ICE BUCKET IN ORDER TO SEE STATUS OF IM BAIL ARM

Bail arm successfully completes test and “Er” is not displayed at the end

 

 

 

 

Allow bail arm to drop freely, “Em” (empty) will show when tray returns home

of each cycle

 

 

 

 

Hold bail arm up by hand, “Fu” (full) will show when tray returns home

 

 

 

 

 

In case of failure at end of twisting operation, will show “Er”; Screen will blink “1” during rotation

 

61

 

Stepper Motor Valve

Press FREEZE BOOST to change status of load

COMPRESSOR WILL AUTOMATICALLY RUN AT MAX SPEED

Valve successfully cycles through all 4 positions; evap temps are increas-

 

 

 

 

Valve can cycle through 4 states:

ing/decreasing as described

 

 

 

 

1.

“03” - Open position

 

 

 

 

 

2.

“00” - Close position

 

 

 

 

 

3.

“01” - IM/FZ position

 

 

 

 

 

4. “02” - FF/IM/FZ position

 

 

 

 

 

FFIM Evap temp is flashed during 00 and 01 to check if temp is increasing/decreasing in FFIM evap

 

 

 

 

 

FF Evap temp is flashed during steps 03 and 02 to see if temp is increasing/decreasing in FF evap

 

 

 

 

 

During movement

 

23

 

FF Door

Open/Close FF Door

Display shows “CL” when door is closed, “OP” when open

Display reads correctly when door is opened/closed

24

 

FRZ Door

Open/Close FRZ Door

Display shows “CL” when door is closed, “OP” when open

Display reads correctly when door is opened/closed

25

 

VCZ Door

Open/Close VCZ Door

Display shows “CL” when door is closed, “OP” when open

Display reads correctly when door is opened/closed

28

 

Dispenser Paddle

Press paddle

Display shows “oF” when paddle is not pressed or released; shows “on” when paddle is pressed

Display shows “oF” when paddle is not pressed and “on” when paddle

 

 

 

 

 

 

is pressed

29

 

FF Temp Sensor

Activates automatically

Display will show compartment temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

30

 

FRZ Temp Sensor

Activates automatically

Display will show compartment temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

31

 

FF Evaporator Temp Sensor

Activates automatically

Display will show FF evaporator temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

32

 

VCZ Temp Sensor

Activates automatically

Display will show compartment temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

33

 

Ambient Temp Sensor

Activates automatically

Display will show ambient temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

39

 

FRZ Evaporator Temp Sensor

Activates automatically

Display will show FRZ evaporator temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

45

 

FFIM Tray Temp Sensor

Activates automatically

Display will show FFIM tray temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

68

 

FFIM Evaporator Temp Sensor

Activates automatically

Display will show FFIM evaporator temperature in either °C or °F depending on mode

Temperature is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

64

 

Humidity Sensor

Activates automatically

Display will show relative humidity sensed by H&T sensor in %

Humidity is displayed and does not show “OP” or “SH”

 

 

 

 

Display will read “OP” if open circuit, “SH” if short circuit

 

SERVICE DATA SHEET

A17002005

ICE & WATER - AUTOMATIC DEFROST

BOTTOM FREEZER - R600a

IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

This concludes the hardware tests. The following tests correspond to firmware versions. Before each firmware version is displayed “--” will appear on screen followed by each 8-digit string representing firmware version. After the string has been displayed, “--” will appear again before automatically proceeded to the next 8-digit string. Press “+” to advance to the next string at any time

--

Software

Runs automatically scrolling through all digits

Displays digit sequence related to software load-

Software version is able to

 

Version

Press “+” button to skip to next test

ed onto main power board; 8 digit sequence

be recorded from display

--

Main Board

Runs automatically scrolling through all digits

Displays digit sequence related to firmware

Firmware version is able to

 

FirmwareVersion

Press “+” button to skip to next test

loaded onto main power board; 8 digit sequence

be recorded from display

--

In-Door UI

Runs automatically scrolling through all digits

Displays digit sequence related to firmware loaded

Firmware version is able to

 

FirmwareVersion

Press “+” button to skip to next test

onto Jade UI (inside door UI); 8 digit sequence

be recorded from display

--

VCZ UI

Runs automatically scrolling through all digits

Displays digit sequence related to firmware

Firmware version is able to

 

FirmwareVersion

Press “+” button to skip to next test

loaded onto Indigo UI (VCZ UI); 8 digit sequence

be recorded from display

--

Dispenser UI

Runs automatically scrolling through all digits

Displays digit sequence related to firmware

Firmware version is able to

 

FirmwareVersion

Press “+” button to skip to next test

loaded onto external 4 button dispenser UI; 8

be recorded from display

 

 

 

digit sequence

 

--

Lifetime

Press + button to advance to next digit

Displays number of days the appliance has

Lifetime displays success-

 

 

 

been powered up, even not consecutively

fully on display

 

 

 

Range is from 0-9999

 

After Lifetime is displayed, last display is a 1-second counting up timer (0, 1, 2, 3…) this communicates that Service Mode has come to an end To return to normal operation, press and hold “+” and “-” for 10 seconds or plug/unplug the appliance

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING

Type A with Run / Start Capacitor

65°F (18°C) Ambient

 

 

 

90°F (32°C) Ambient

 

Operating Time

 

70 to 90%

 

 

 

90 to 100%

 

Freezer Temp

 

-6° to 6°F (-21° to -14°C)

 

 

-6° to 6°F (-21° to -14°C)

 

Refrigerator Temp

34° to 44°F (1° to 7°C)

 

 

 

34° to 44°F (1° to 7°C)

 

VCZ Temperature

-6° to 45°F (-21° to 7°C)

 

 

-6° to 45°F (-21° to 7°C)

 

Low Side Pressure

-1 to 3 psig (98 to 124 kPa)

 

 

.8 to 3 psig (107 to 120 kPa)

 

High Side Pressure (last 1/3 cycle)

69 to 83 psig (577 to 672 kPa)

 

 

117 to 128 psig (907 to 982 kPa)

Wattage (last 1/3 cycle)

45 to 55

 

 

 

54 to 74

 

Amps (running)

 

.7 to .9

 

 

 

.8 to 1.1

 

Base Voltage

 

115 vac (127 vac max)

 

 

 

 

 

 

 

 

 

DEFROST SPECIFICATIONS

 

 

 

 

 

 

 

Thermal Cutout

 

 

Heater

 

Defrost Thermistor

 

 

 

 

 

 

 

 

 

Termination

Cabinet Size:

 

 

Cut-out

 

Watts

 

Ohms

 

Cut-out

 

 

 

 

 

 

 

 

 

22’ CD

 

FRZ

 

 

220 +/- 5

 

51.3 +/- 5

 

48°F (8°C)

 

 

FF

162°F

 

 

 

38°F (3°C)

 

 

(72.2°C)

 

 

 

 

 

 

 

FFIM

 

 

70 +/- 5

 

189 +/- 5

 

61°F (16°C)

Electronic Timer - (ADC) Defrost 34 minutes every 12-96 hours of compressor run time.

CONDENSER FAN MOTOR

 

Watts

 

RPM

 

Amps

 

.75

1.25

1100 ± 100

 

40 L/S

.104 A Max

Nominal Input Power

Max Input Power

Speed (R/Min)

 

Air Flow in Free Air

 

(@12V DC/20°C)

(W) @ 80% Duty

(W)

*@80% Duty @ 100%

 

(0 Pa)

 

 

 

 

ERROR CODES

 

 

 

Display

 

Interpretation

 

1st message

2nd message

 

 

 

 

 

 

 

Er

t1

 

Fzr Temp Sensor Open/Shorted

 

Er

t2

 

Fzr Defrost Sensor Open/Shorted

 

Er

t3

 

FF Temp Sensor Open/Shorted

 

Er

t4

 

FF Defrost Sensor Open/Shorted

 

Er

t5

 

VCZ Temp Sensor Open/Shorted

 

Er

t6

 

FFIM Tray Sensor Open/Shorted

 

Er

CE

 

Communication Error UI to Main Board

 

No message - Dispenser UI will

 

Chute Flapper Not Closed

 

beep and blink either Cube or

 

 

 

 

 

Crush (whichever is selected at

 

 

 

 

 

the time of the error)

 

 

 

 

 

 

 

 

SPECIAL MODES

 

 

 

Mode

Display

 

Activate

 

Deactivate

Manual

dF

Hold + and Air Filter for 10 secs

 

---

 

Defrost

 

 

 

 

 

 

Cube Size

Settings will ap-

Hold FREEZE BOOST and Ice Maker for 10 secs

 

After 10 secs of no activity

Menu

pear on UI

 

 

 

 

 

 

 

 

Demo /

Demo Light On

Hold - and Water Filter for 10 secs

 

Hold - and Water Filter for 10 secs

Showroom

 

 

 

 

 

 

 

 

 

Sabbath

Sb

Hold - and Temp F-C for 5 secs

 

Hold - and Temp F-C for 5 secs

Service

---

Hold - and + for 10 secs

Hold - and + for 10 secs, or after 10 mins of inactivity

°F/°C Display

Look at UI

Press Temp F-C to alternate between °F and °C

 

---

 

Notes: Always check for pin backouts, pinched or damaged wires before replacing components. Determine whether failure is caused by the component, main control board or wiring. Contact TID before replacing main control board. Refer to Service

Manual for additional information.