TS-1001, BulkStik, AutoStik (except AutoStik II 8Ch) Ribbon Cable (P/N 600-0077 & 600-0032):

Cable glossy side up / to the right silver conductor side down / to the left.

Diagram: 1

Removal (with all Tank Gauge power OFF):

Remove ribbon cable by pulling it straight out of its connector (see above). NOTE: The 26 conductor printer cable is P/N 600-0032 and the 20 conductor Display and Keypad cable is P/N 600-0077.

Installation (with all Tank Gauge power OFF):

Install the cables back into the appropriate connector gloss side up or to the right

(silver conductor side down or to the left). Do this by grasping the flat ribbon cable near the end and pushing it straight into its connector.