Follett 110CR400A-W-L Service Manual

110 Series
Ice and Water Dispensers
Installation, Operation and Service Manual
110CT400A/W-L
110CR400A/W-L
Following installation, please forward this manual
to the appropriate operations person.
801 Church Lane • Easton, PA 18040, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com
110FB400A/W-L
208597R06
Follett Corporation Equipment Return Policy
Follett equipment may be returned for credit under the following conditions:
1. The equipment is new and unused.
2. A return authorization number has been issued by customer service within 30 days after shipment.
3. Follett receives the equipment at the factory in Easton, PA within 30 days after issuance of the return authorization number.
4. The equipment must be returned in Follett packaging. If the packaging has been damaged or discarded, Follett will forward, at the customer’s expense, new packaging.
Note: Return freight charges are the responsibility of the customer. If equipment is returned and is damaged because of
improper packaging, Follett Corporation will not be held responsible.
Credit will be issued when: The equipment has been inspected by Follett and deemed suitable to be returned to stock.
Note: A 15% restocking charge will be deducted from the credit. If the cost to return the product to stock exceeds 15%, the
actual cost will be deducted.
2
Table of contents
Before you begin Speci cations Field wiring Installation
Installing freestanding dispensers Installing wall mount dispensers Installing Satellite- ll
Installing top mount icemakers
User information
Cleaning and sanitizing procedures
Service Information
Wiring diagram – lever models Wiring diagram – SensorSAFE™ models Dispenser troubleshooting Troubleshooting SensorSAFE board and sensors Disassembly and replacement instructions Thermostat locations
Parts
Dispenser exterior Dispense chute and splash panel areas – lever models Electrical box – lever models Dispense chute and splash panel areas – SensorSAFE models Electrical box – SensorSAFE models Wheel motor and drive system Hopper components Chilled water components Solenoid dispense assembly
icemakers
4 5 6 8
8 10 12 12 14 14 16 16 17 18 19 20 23 24 24 25 25 26 27 27 28 29 30
3
Welcome to Follett
!
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this equipment delivers that same degree of service, we ask that you review the installation portion of this manual before beginning to install the unit. Our installation instructions are designed to help you achieve a trouble-free installation. Should you have any questions or require technical help at any time, please call our technical service group toll free at (800) 523-9361 or (610) 252-7301.
Before you begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage is found, notify your shipper immediately and contact Follett Corporation for help in  ling a claim, if necessary.
Check your paperwork to determine which model you have. Follett model numbers are designed to provide information about the type and capacity of Follett equipment. Following is an explanation of model numbers:
110CT400A-L
L = Lever dispensing, S = SensorSAFE infrared dispensing Condenser type – A = air-cooled, W = water-cooled
Icemaker capacity and refrigerant – 400 = 400 lbs (181kg)/day, R404A refrigerant
Icemaker location – R = Satellite- ll icemaker, T = integral icemaker in top of cabinet, B = icemaker in base of freestanding units
Dispenser con guration – C = countertop, F = freestanding
Approximate storage capacity in lbs
Important cautions
• Do not tilt any unit further than 30° off vertical during uncrating or installation
• Dispenser bin area contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If access to this area is required, power to unit must be disconnected  rst.
• Follett recommends a Follett QC4-FL4S water  lter system (item# 00130229) be installed in the icemaker inlet water line
• Prior to operation clean and sanitize the dispenser in accordance with instructions found in this manual
• Ice is slippery. Be sure counters and  oors around dispenser are clean, dry and free of ice.
4
Speci cations
Electrical
1. Models with Satellite- ll icemakers (110CR400A/W)
Icemaker Max. fuse Dispenser Max. fuse Basic electrical: 115V/60Hz/1 phase 11.0 amps 20 amps 4.0 amps 20 amps
2. Freestanding models and models with integral icemakers (110FB400A/W, 110CT400A/W)
Total system Max. fuse Basic electrical: 115V/60Hz/1 phase 14.0 amps 20 amps
3. Dispensers and Satellite- ll icemakers are supplied with 7-foot power cord with NEMA 5-20 hospital grade plug. Connect to 20 amp circuit fuse or breaker.
Note: It is preferred that circuit be protected by a GFCI.
Ambient
Air temp 100 F/38 C max. 50 F/10 C min. (best performance below 80 F/27 C) Water temp 90 F/32 C max. 40 F/4 C min. (best performance below 70 F/21 C) Water pressure 70 P.S.I. max. 10 P.S.I. min.
Plumbing
110CR with 110CT with 110FB with
Satellite- ll icemaker integral icemaker icemaker in base
Dispenser drain 3/4" FPT 3/4" FPT 3/4" FPT
Icemaker drain 3/4" MPT 3/4" MPT 3/4" MPT
Dispenser water inlet 3/8" FPT 3/8" FPT 3/8" FPT
Icemaker water inlet 3/8" FPT
Satellite- ll IM water inlet 3/8" OD push-in
Cond. inlet – w/c only 3/8" FPT 3/8" FPT 3/8" FPT
Cond. drain – w/c only 3/8" FPT 3/8" FPT 1/2" FPT
Note: Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard piped and insulated, and maintain slope of at least 1/4" per foot (6mm per 305mm run) of slope. All plumbing connections must be made in accordance with local building codes.
Ventilation clearances
Countertop models with Satellite- ll icemaker (110CR400A/W) — none. 12" (775mm) at top advised for service.
Countertop models with integral icemaker (110CT400A/W) — 6" (153mm) at top. 6" (153mm) each side advised for service.
Freestanding models (110FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top advised for service.
5
Field wiring for countertop and wall mount dispensers with Satellite- ll
!
!
icemakers
All  eld wiring must be installed in accordance with NEC and local electrical codes. Field wiring diagram is intended only to aid electrician or technician in understanding how equipment works.
Field wiring for countertop and wall mount dispensers with Satellite- ll icemakers
Attention – Should local codes require a hard-wired connection and/or shielded wiring, eliminate the cord and plug(s) and follow the appropriate  eld wiring diagram on the following page.
See Icemaker Installation and Operation manual for recommended junction box preparation of hard­wired Satellite- ll icemakers.
Model Electrical connection Circuits required
110FB400A/W cord & plug provided 115/60/1, 20 amp max. fuse size
110CT400A/W cord & plug provided 115/60/1, 20 amp max. fuse size
110CR400A/W cord & plug provided 115/60/1
dispenser: 20 amp max. fuse size
icemaker: 20 amp max. fuse size
6
Field wiring diagrams
Freestanding dispensers and countertop dispensers with integral icemakers
LEGEND
WIRENUT
EQUIPMENT
X
GROUND
B - BLACK
W - WHITE R - RED
IMPORTANT
FIELD WIRING DIAGRAM IS INTENDED TO AID ELECTRICIAN OR TECHNICIAN IN UNDERSTANDING HOW EQUIPMENT WORKS. ALL FIELD WIRING MUST BE INSTALLED IN ACCORDANCE WITH NEC AND LOCAL ELECTRICAL CODES.
DISPENSER JUNCTION BOX
GRN
GND
X
B
W
R
Electric Power Source
GND
X
GRN
GRN - GREEN
Countertop dispensers with Satellite- ll icemakers
LEGEND
WIRENUT
X
EQUIPMENT GROUND
B - BLACK
W - WHITE
R - RED
GRN - GREEN
DISPENSER JUNCTION BOX
GRN
GND
X
B
W
R
Standard electric - 115V, 60 Hz, 1 Ph, Max. fuse size per circuit - 20 amps
Electric Power Source
BW
GND
X
GRN
FUSED DISCONNECT
FIELD WIRING DIAGRAM IS INTENDED TO AID ELECTRICIAN OR TECHNICIAN IN UNDERSTANDING HOW EQUIPMENT WORKS. ALL FIELD WIRING MUST BE INSTALLED IN ACCORDANCE WITH NEC AND LOCAL ELECTRICAL CODES.
LOWER ICEMAKER JUNCTION BOX (BIN SIGNAL)
W
B
BW
FUSED DISCONNECT
IMPORTANT
Electric Power Source
W
B
Standard electrical - 115V, 1 Ph, 60 Hz, max. fuse size 20 amps
GND
X
GRN
UPPER ICEMAKER JUNCTION BOX
FUSED DISCONNECT
(POWER)
GND
GRN
X
W
B
7
Installation procedures
!
Before you begin
All dispensers must be installed level in both directions to ensure proper operation
Required ventilation and recommended service clearances:
• Countertop models with Satellite- ll icemaker (110CR400A/W) — none. 12" (305mm) at top recommended for service.
• Countertop models with integral icemaker (110CT400A/W) — 6" (153mm) at top. 6"(153mm) each side recommended for service.
• Freestanding models (110FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top recommended for service.
All countertop dispensers provide the option of taking utilities out the bottom or back of the dispenser. See counter cutout on page 10 (Fig. 2) for bottom exiting utilities on units with and without drain pans. For installations where utilities will exit through back of dispenser, refer to back view drawings.
SensorSAFE dispensers are shipped with a plastic, protective  lm on sensor lenses. For proper operation, plastic  lm
must be removed after installation.
Installing freestanding dispensers
1. Carefully tip dispenser back to expose underside and block up in place.
Do not tilt unit further than 30° off vertical.
2. Remove legs from shipping box (taped to drain pan of dispenser) and screw into dispenser bottom, taking care to seat legs securely against underside of dispenser.
3. Position dispenser in desired location and adjust legs to level in both directions.
4. Connect water supply to 3/8" FPT  tting on back of dispenser (Fig. 1A).
5. Remove 3/4" dispenser drain line plug from back of unit and discard. Connect separate drain lines to 3/4" FPT dispenser drain  tting and 3/4" MPT icemaker drain  tting on back of dispenser (Fig. 1B and 1C.)
6. Run drain lines to wall or  oor drain. Provide an air break between the drain lines and drain. If icemaker drain  tting is below an intended wall drain, a condensate pump must be used.
7. If icemaker is water-cooled, connect water-cooled condenser supply line to 3/8" FPT condenser inlet  tting on back of dispenser (Fig. 1D).
Note: Do not run condenser supply water through icemaker water  lter system.
8. Connect condenser drain line to 3/8" FPT condenser outlet  tting on back of dispenser (Fig. 1E).
Important: Do not connect condenser drain line to any other drain lines.
9. Plug dispenser into 20 amp rated NEMA 5-20 wall socket.
10. Remove front cover of base section by removing two screws at bottom corners of cover. Allow cover to drop approximately 3/8" (5mm) and pull forward.
11. Turn on water supply and check that water level in  oat reservoir (when full) is within 1/4" (6mm) of mark on side of reservoir and that  oat moves freely. Check for leaks.
8
Fig. 1 – Rear connections, freestanding models
(B) 3/4” FPT drain
(A) 3/8" FPT
water inlet (A)
access panel
(D) 3/8" FPT condenser inlet location (water-
cooled only)
water inlet
(E) 3/8" FPT
condenser drain
location (water-
cooled only)
(C) 3/4" MPT
icemaker drain
location (air­cooled only)
(800mm)
10.25"
(260mm)
31.5"
(800mm)
(C) 3/4" MPT
icemaker drain
location (water-
cooled only)
31.5"
12. Verify that water sensor tabs are immersed in water in reservoir.
13. Remove top front cover by removing two screws at bottom corners of cover. Lift cover slightly and pull forward.
14. If dispenser is equipped with SensorSAFE, remove protective plastic coating from dispense sensor labels.
15. Turn on dispenser power and bin signal rocker switches. Check dispenser and icemaker operation.
16. Sanitize icemaker according to instructions in icemaker manual. Discard sanitized ice.
17. Turn off icemaker bin signal switch.
18. Remove dispenser hopper lid; clean and sanitize dispenser according to instructions beginning on page 14.
19. Turn icemaker bin signal switch on and replace front covers, securing with screws.
9
Installing countertop dispensers
24.5"
(622mm)
23.75"
(603mm)
6.54"
(167mm)
17.375"
(441mm)
21.375"
(543mm)
3/8"
12.25"
(311mm)
.5" (13mm)
1.625" (41mm)
.5" (13mm)
9" X 14" (227mm x 356mm)
DRAIN PAN
CUT OUT
!
Dispensers with top mount icemakers cannot be mounted on legs. They must be bolted to counter. Use gloves when lifting icemaker to protect hands from sheet metal edges.
1. Position dispenser in desired location, mark dispenser outline on counter and remove dispenser.
2. Drill four 3/8" (5mm) holes in counter (Fig. 2) to anchor dispenser to counter.
Follett countertop dispensers can have any or all
utilities run directly through counter or out rear of dispenser. For dispensers with any utilities exiting through counter, make counter cut-out as shown in Fig. 2.
3. If ice transport tube will exit out rear of dispenser,
remove ice transport tube knock-out (Fig. 5G) from rear of dispenser.
Note: Utility connections can be accessed through
front of dispenser by removing stainless steel splash panel on front of dispenser, or by removing access panel (Figs. 4, 5) on back of dispenser.
4. If any electric utilities or water line will be connected through rear of dispenser, remove utility knock-out (Fig. 5H) from rear of dispenser and install supplied protective grommet.
5. If power is to be supplied through counter cut-out, complete steps 6-9. If power is to be supplied through rear of dispenser, proceed to step 10.
6. Temporarily remove rear access panel (Figs. 4, 5) from rear of dispenser.
7. Loosen junction box mounting screws. Lift junction box and power cord up until cord and mounting screws clear notches on rear panel of dispenser. Remove Phillips head screws from right side of junction box.
8. Rotate junction box 90 degrees so that screw holes on right side of junction box align with holes on rear dispenser panel. Resecure junction box to dispenser using Phillips head screws.
9. Place power cord inside dispenser and replace access panel (Figs. 4 and 5) on rear of dispenser.
Note: For dispensers installed with utilities connected
through rear of dispenser, it may be easier to make preliminary connections before dispenser is set in place.
Fig. 2 – Counter cut-out, all models
Fig. 3 – Top view, dispenser plumbing connections countertop and wall mount units with drain pan
(K) 3/4" FPT dispenser drain
(L) alternate 3/4" dispenser drain location
(J) 3/8" FPT water inlet
drain pan
10