Fluke Corporation (Fluke) warrants this product to be free from defects in material and workmanship under normal use and
service for the life of the product. This warranty extends only to the original buyer or end-user customer of a Fluke
authorized reseller, and does not apply to fuses, batteries or to any product which, in Fluke’s opinion, has been misused,
altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software
will operate on appropriate Fluke instruments substantially in accordance with its functional specifications for 90 days and
that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or
operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no
authority to extend a greater or different warranty on behalf of Fluke.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, or free of charge repair or
replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of
the difficulty, postage and insurance prepaid (FCA Destination), to the nearest Fluke authorized service center. Fluke
assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation
prepaid (FCA Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or abnormal
condition of operation or handling, Fluke will provide an estimate of repair costs and obtain authorization before
commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will
be billed for the repair and return transportation charges (FCA Shipping Point).
Warranty service is available outside the United States only if product was purchased through a Fluke Authorized Sales
Outlet in the country of use or the applicable Fluke international price was paid. Product transported from the United
States for which the applicable Fluke international price was not paid must be returned to the U.S. to receive warranty
service, at the shipment expense and risk of Buyer. Fluke reserved the right to invoice Buyer for importation costs of
repair/replacement parts when product purchased in one country is submitted for repair in another country.
THIS WARRANTY IS PURCHASER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA,
WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY
OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of
incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any
provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect
the validity or enforceability of any other provision.
To locate an authorized service center, visit us on the World Wide Web at www.fluke.com or call Fluke using the phone
numbers listed below:
1-888-99-FLUKE (1-888-993-5853) in USA and Canada
+31 402-678-200 in Europe
+81-3-3434-0181 Japan
+65-738-5655 Singapore
+1-425-356-5500 in other countries
Fluke Corporation Fluke Europe B.V.
P.O. Box 9090 P.O. Box 1186
Everett WA 98206-9090 5602 B.D.
U.S.A Eindhoven, The Netherlands
7.Replacement Parts and Accessories...................................................................... 29
v
87 & 89 Series IV
Service Information
vi
Introduction
To avoid shock or injury, do not perform the verification tests
or calibration procedures described in this manual unless you
are qualified to do so.
The information provided in this document is for the use of
qualified personnel only.
The 87 & 89 Series IV Multimeters contain parts that can be
damaged by static discharge.
Follow the standard practices for handling static sensitive
devices.
The information in this manual deals with the Fluke Models 87 & 89 Series IV True
RMS Multimeters, (hereafter referred to as “the meter”). Information provided includes:
• Precautions and safety information
• Specifications
• Basic maintenance (cleaning, replacing the battery and fuses)
• Performance test procedures
• Calibration and calibration adjustment procedures
• Accessories and replaceable parts
Warning
Caution
For complete operating instructions, refer to the Model 87 & 89 Series IVUsers Manual.To contact Fluke, call:
1-888-993-5853 in USA and Canada+31 402-678-200 in Europe+81-3-3434-0181 Japan+65-738-5655 Singapore+1-425-356-5500 in other countries
For additional information about Fluke, its products and services, visit Fluke’s web site
at:
www.fluke.com
1
87 & 89 Series IV
Service Manual
Precautions and Safety Information
International Symbols
Use the Meter only as described in the Users Manual. If you do not do so, the protection
provided by the Meter may be impaired.
Read the “Safety Information” page before servicing this product.In this manual, a Warning identifies conditions and actions that pose hazard(s) to the
user; a Caution identifies conditions and actions that may damage the Meter or the test
instruments.
International symbols used on the Meter and in this manual are explained in Table 1.
Table 1. International Symbols
SymbolMeaningSymbolMeaning
Alternating currentEarth ground
Direct currentAlternating or direct currentConforms to European Union
Refer to the manual. Important
information.
Inspected and licensed by TÜV
Product Services.
Battery
Fuse
directives
Conforms to relevant Canadian
Standards Association directives
Double insulated
Underwriters Laboratories, Inc.
2
Safety Information
Safety Information
Warnings and Precautions
To avoid possible electric shock or personal injury, follow these guidelines:
• Do not use the Meter if it is damaged. Before you use the Meter, inspect the case.
Look for cracks or missing plastic. Pay particular attention to the insulation
surrounding the connectors.
• Inspect the test leads for damaged insulation or exposed metal. Check the test
leads for continuity. Replace damaged test leads before you use the Meter.
• Do not use the Meter if it operates abnormally. Protection may be impaired. When in
doubt, have the Meter serviced.
• Do not operate the Meter around explosive gas, vapor, or dust.
• Do not apply more than the rated voltage, as marked on the Meter, between
terminals or between any terminal and earth ground.
• Before use, verify the Meter’s operation by measuring a known voltage.
• When measuring current, turn off circuit power before connecting the Meter in the
circuit. Remember to place the Meter in series with the circuit.
• When servicing the Meter, use only specified replacement parts.
• Use caution when working above 30 V ac rms, 42 V peak, or 60 V dc. Such voltages
pose a shock hazard.
• Avoid working alone.
• When using the probes, keep your fingers behind the finger guards on the probes.
• Connect the common test lead before you connect the live test lead. When you
disconnect test leads, disconnect the live test lead first.
• Remove test leads from the Meter before you open the battery door.
• Do not operate the Meter with the battery door or portions of the cover removed or
loosened.
•To avoid false readings, which could lead to possible electric shock or personal
injury, replace the batteries as soon as the low battery indicator (
•Use only type AA batteries, properly installed in the Meter case, to power the Meter.Caution
To avoid possible damage to the Meter or to the equipment under test, follow these
guidelines:
•Disconnect circuit power and discharge all high-voltage capacitors before testing
resistance, continuity, diodes, or capacitance.
) appears.
• Use the proper terminals, function, and range for your measurements.
• Before measuring current, check the Meter's fuses and turn power OFF to the
circuit before connecting the Meter to the circuit.
3
87 & 89 Series IV
Service Manual
Specifications
Accuracy
Accuracy is specified for a period of one year after calibration, at 18 °C to 28 °C (64 °F
to 82 °F), with relative humidity to 90 %. Accuracy specifications are given as:
AC mV, AC V, AC µA, AC mA, and AC A specifications are ac-coupled, true rms and are
valid from 5 % of range to 100 % of range. AC crest factor can be up to 3.0 at full-scale, 6.0
at half-scale, except the 3000 mV and 1000 V ranges where it is 1.5 at full scale, 3.0 at halfscale.
Feature Summary
Dual Digital Displays
Analog Bar Graph
Backlight with 2 brightness adjustment Bright-white backlight for clear readings in poorly lighted
Fast Autorange Meter automatically selects best range
AC+DC true rms, ac rms specified to 100
kHz
dBm, dBV User-selectable impedance references for dBm
AutoHOLD Holds readings on display
Continuity / Open test Beeper sounds for resistance readings below threshold, or
Fast Bar Graph 51 segments for peaking and nulling
Duty cycle / Pulse width Measure the time signal is on or off in % or milliseconds
MIN MAX Mode
FAST MN MX with 24-hour time stamp
Close-Case Calibration No internal adjustments needed
Battery / Fuse Access Door Battery or fuse replaceable without voiding calibration
Hi-Impact Overmolded Case Protective holster features
± ( [ % of reading ] + [ number of least significant digits ] )