Fisher & Paykel RH900 User Manual

INSTALLATION INSTRUCTION
APEX MODEL RH900 CQ SS NZ/AUS Code 87947 UK Code 88793 EU Code 88955
APEX MODEL RH900 CM SM NZ/AUS Code 87948 UK Code 88794 EU Code 88956
PLEASE READ THE ENTIRE INSTRUCTION BEFORE INSTALLING THE CANOPY
PRODUCT DIMENSIONS
290
330
CANOPY OPERATION
Thank you for purchasing a quality stainless steel or iridium canopy rangehood. We have a high standard of quality control and each rangehood is tested and approved before it leaves the factory.
IMPORTANT: Please read prior to installation or operation
Always switch power off prior to installing, servicing or cleaning the appliance.
Never use the appliance without filters.
• Please read the notes on general cleaning, especially the filters.
• Exhaust air must not be discharged into a heating flue or wall cavity, unless the cavity is designed for that purpose.
• Areas where the rangehood is installed that also have gas, oil or coal fired heaters, must be well ventilated to prevent a partial vacuum in the room. This includes gas hobs. (A partial vacuum in the room could result in too high a concentration of gas in the air).
• The appliance is supplied with an approved power cable which must not be changed. If the supply cord of this equipment is damaged, it must only be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid hazard.
MAINTENANCE
Particular care must be taken with grease filters which must be periodically cleaned (at least every two months). Remove the grease filters and wash them either by hand or in the dishwasher using mild detergent. In case of Charcoal Filter, it is a disposable item and should be replaced when cleaning the rangehood. Use lukewarm water and mild detergent to clean stainless steel components. In high humidity and coastal environments, cleaning should be carried out frequently. CAUTION: Never use abrasive or oil based liquid cleaners.
USE Care and attention should always be taken when cooking with oils, alcohol, etc; which give off flammable vapours. Pre-used oil is especially dangerous in this respect. Do not use uncovered electrical grill. To avoid possible risks of fire always comply with the maintenance instruction above.
When making the electrical connection, check that the socket has an earth connection and that the voltage values correspond to those indicated on the rating plate inside the appliance. The appliance must be positioned so that the electrial plug is accessible.
All Dimensions in mm
897
CONTROL PANEL
Left Push Button = Light On/Off Switch Second Push Button = Fan On High Speed Third Push Button = Fan On Second Speed Fourth Push Button = Fan On Low Speed Fifth Push Button = Fan Off
INSTALLATION OF UNIT
780 min
21
115
488
528
The unit is designed for 2.4 to 2.65 metre high ceiling. The decorative chimney cover is telescopic and is designed for 665 to 950mm adjustment.
Note: Ducting accessories are not supplied. Please refer to the optional ducting kits. The air outlet from the motor requires 150mm round ducting which requires 160mm diameter round hole in the ceiling. This hole will be covered by the decorative chimney. Care should be taken to align canopy with decorative chimney allowing sufficient clearance to accommodate the flexible ducting.
Before starting assembly, read the instructions carefully and remove the filters from canopy to allow access to wall mounting holes. To remove the filters, pull the relative catch and tilting it downwards until it disengages from the supports. Reverse these instructions when refitting the filters.
Stainless steel/iridium is very easily damaged during installation if abraided or knocked by tools.
104385 issue H ECN: 04 036
INSTALLATION OF THE UNIT
DUCTING
OPTION
A
200mm
WARNING: The distance between the hob and the mounting holes of the canopy to be at least 900mm to ensure that the fully installed canopy has a clearance of 700mm (recommended height) between the lower part of the hood and the cooking hob. Before drilling any holes check the wall and the ceiling are clear of any electrical cables, pipes etc. Fixing to a solid stud is recommended. A
Fix the mounting washers in position shown in diagram. 1 Check with spirit level accross the washers to ensure they are level.
INSTALLING DUCTING NOTE: All ducting must comply with local requirements and building codes. Mark the position of decorative chimney at ceiling and wall, cut cornice moulding away if necessary to enable panels to fit flat against the wall and ceiling. 2 Mark and cut the hole in the ceiling to fit the ducting (155 to 160mm dia). 3 This is positioned centrally with the canopy and 100mm from the wall.
INSTALLING CEILING BRACKET Using the supplied screws, fix the ceiling bracket 4 to the wall, checking that it is aligned with the hood.
RECIRCULATING
2.4 TO 2.65 METRE HIGH CEILING
OPTION
700mm
UNDERSIDE OF HOOD
TO COOKING SURFACE
FINAL ASSEMBLY Remove protective plastic covering from all parts including filters. Now fit the canopy on the fixed mounting washers. 5 Plug in power cord at power supply. Check function of rangehood light and motor, before continuing assembly. Fix safety screw 5 connect 150mm ducting 6 to top of motor flange secure with cable tie. Assemble the telescopic ducting covers (chimney) 7 to accurately suit the dimension required, 8 fit black plastic extrusion to the base and top of the chimney and cut to length. 9 Mounting screws and plastic cover caps are applied on top and bottom of the chimney.
DUCTING
RECIRCULATING
TOP
GUIDE
Lamp Replacement
a)Switch off the power to the rangehood. b)Use a small bladed screwdriver to prise off the light cover (note slot). c) Use a cloth to remove the bulb. Do not touch the bulb with fingers. d)Replace with a new bulb and “snap” the cover back into place. e)Halogen bulb 12Volt/20W att required.
BULB
Parts & Service
FILTERS Aluminium Filter - No. R104163 (Ducted models) Charcoal Filter No. R104165 (Recirculated models) The use of charcoal filter is recommended on recirculating model rangehoods.
DUCTED UNIDUCT FLEXI DUCT FIT is recommended. 1569 Flexi Duct Kit (150mm)
RECIRCULATED Use manufacturer Part No. 89504
NOTE: TAB ON
DETAIL 1
For other Accessories, Parts or Service, please contact your local supplier. (Refer to the Warranty Certificate)
BOTH SIDES TO BE BENT IN TO LOCK DUCT IN PLACE
WARNING
• This appliance is not intended for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the appliance.
• There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances burning gas or other fuels.
• You must read the details concerning the method and frequency of cleaning.
• There is a fire risk if cleaning is not carried out in accordance with the instructions.
• Do not flambé under the rangehood.
• Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels.
• The minimum distance between the hob surface and the lowest part of the rangehood is 600mm. This distance shall be at least 650mm (recommended 700mm) if the rangehood is installed over a gas hob.
• Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air is fulfilled.
• If the supply cord of this equipment is damaged, it must only be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard.
MANUFACTURED FOR
Electrical Rating: 346W (1.44A) Max. at 230-240V 50Hz
RECOMMENDED UNIDUCT DUCTING
SYSTEMS FOR RANGEHOODS
BY:
ROBINHOOD LIMITED
6 ZELANIAN DRIVE, EAST TAMAKI
AUCKLAND, NEW ZEALAND
ISO9001 Certified
SEE DETAIL
Rercirculating Kit 89504
6
104385 issue H ECN: 04 036
1
Loading...