Fisher & Paykel DD60SCHW7, DD60SCB7, DD60SCHB7, DD60SCM7, DD60SDFX7 Installation Instructions Manual

...
Page 1
NZ AU GB IE
590200D 04.13
DD60S 7 & DD60ST 7 models
INSTALLATION INSTRUCTIONS
DishDrawer
TM
dishwasher
Page 2
2
FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL
1
DD60SHI7 DD60SLI7
(not available in GBIE, only NZAU)
Classic
PRODUCT & CABINETRY
DIMENSIONS
(STANDARD HEIGHT)
PRODUCT & CABINETRY
DIMENSIONS
(STANDARD HEIGHT)
PRODUCT & CABINETRY
DIMENSIONS
(STANDARD HEIGHT)
PRODUCT & CABINETRY
DIMENSIONS
(TALL HEIGHT)
PRODUCT & CABINETRY
DIMENSIONS
(TALL HEIGHT)
PRODUCT & CABINETRY
DIMENSIONS
(TALL HEIGHT)
DD60SC(H)X7 DD60SC(H)W7
DD60SDF(H)X7 DD60SDFM7
DD60SC(H)B7 DD60SCM7
Designer
DD60SI7
DD60SC(H)TX7 DD60SC(H)TW7
DD60SDF(H)TX7 DD60SDFTM7
DD60SC(H)TM7
Integrated with remote control Integrated with badge control Integrated with remote control Integrated with badge control
Classic
Designer
DD60STI7 DD60SHTI7
CUSTOM FRONT
PANEL CALCULATIONS
CUSTOM FRONT
PANEL CALCULATIONS
PARTS SUPPLIED
CAVITY PREPARATION
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
SECURE WITHOUT
DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
CHOOSE
DRAINAGE OPTION
FINAL CHECKLIST
CONNECT TO WATER & ELECTRICITY
TROUBLESHOOTING
FINAL CHECKLIST
CONNECT TO WATER & ELECTRICITY
PARTS SUPPLIED
CAVITY PREPARATION
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
PARTS SUPPLIED +
EXTERNAL VENTING KIT
PARTS SUPPLIED +
EXTERNAL VENTING KIT
CAVITY PREPARATION
ATTA CH
CAVITY BRACKET
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
SECURE WITHOUT
DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
CHOOSE
DRAINAGE OPTION
FINAL CHECKLIST
TROUBLESHOOTING
FINAL CHECKLIST
TROUBLESHOOTING
SECURE WITHOUT DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
PARTS SUPPLIED
CAVITY PREPARATION
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
SECURE WITHOUT
DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
CHOOSE
DRAINAGE OPTION
FINAL CHECKLIST
CONNECT TO WATER & ELECTRICITY
CHOOSE
DRAINAGE OPTION
TROUBLESHOOTING
PARTS SUPPLIED
CAVITY PREPARATION &
EXTERNAL VENTING
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
FOLLOW STEPS
FOR THE
EXTERNAL
VENTING KIT
INSTALL THE FRONT PANEL
INSTALL THE FRONT PANEL
CONNECT TO WATER & ELECTRICITY
CONNECT TO WATER & ELECTRICITY
CHOOSE
DRAINAGE OPTION
CONNECT TO WATER & ELECTRICITY
CHOOSE
DRAINAGE OPTION
CONNECT TO WATER & ELECTRICITY
CHOOSE
DRAINAGE OPTION
TROUBLESHOOTING
FINAL CHECKLIST
TROUBLESHOOTING
FOLLOW STEPS
FOR THE
EXTERNAL
VENTING KIT
SECURE WITHOUT
DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
480 mm CAVITY
ONLY - ATTACH
CAVITY BRACKET
FINAL CHECKLIST
CHOOSE
DRAINAGE OPTION
CONNECT TO WATER & ELECTRICITY
TROUBLESHOOTING
SECURE WITHOUT
DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
FOLLOW STEPS
FOR THE
EXTERNAL
VENTING KIT
FOLLOW STEPS
FOR THE
EXTERNAL
VENTING KIT
CAVITY PREPARATION &
EXTERNAL VENTING
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
456mm CAVITY
480mm CAVITY
PRODUCT & CABINETRY
DIMENSIONS
(TALL HEIGHT)
CUSTOM FRONT
PANEL CALCULATIONS
PARTS SUPPLIED
480 mm CAVITY
ONLY - ATTACH
CAVITY BRACKET
FINAL CHECKLIST
TROUBLESHOOTING
SECURE WITHOUT
DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
CAVITY PREPARATION
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
456mm CAVITY 480mm CAVITY
PRODUCT & CABINETRY
DIMENSIONS
(STANDARD HEIGHT)
CUSTOM FRONT
PANEL CALCULATIONS
PARTS SUPPLIED
CAVITY PREPARATION
MAXIMUM DISTANCE OF HOSES
& CORD FROM CHASSIS EDGE
INSTALL THE FRONT PANEL
& BADGE CONTROLS
INSTALL THE FRONT PANEL
& BADGE CONTROLS
SECURE WITHOUT
DRAWER REMOVAL
RECOMMENDED
METHOD (a)
ALTERNATIVE
METHOD (b)
SECURE BY
DRAWER REMOVAL
STANDARD HEIGHT SINGLE MODELS
TALL HEIGHT SINGLE MODELS
ONLY AVAILABLE IN NZ AU ONLY AVAILABLE IN NZ AUONLY AVAILABLE IN GB IE ONLY AVAILABLE IN GB IE
Page 3
3
SAFETY AND WARNINGS - ALL MODELS
ADDITIONAL SAFETY AND WARNINGS - INTEGRATED MODELS ONLY
2a
2b
WARNING!
Electrical shock hazard
Before installing the dishwasher, remove the house fuse or open the circuit
breaker.
This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug. The plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances. WARNING- Improper connection of the equipment­earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly earthed.
Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box.
Failure to follow this advice may result in electrical shock or death.
WARNING!
Cut hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.
IMPORTANT SAFETY INSTRUCTIONS!
Installation of this dishwasher requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the dishwasher installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the dishwasher. This dishwasher is manufactured for indoor use only. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations. The dishwasher MUST be installed to allow for future removal from the enclosure if service is required.
The switched power outlet must be outside the dishwasher cavity, so that it is accessible after
installation.
Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord and hoses. If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage.
Make sure only new hoses are used for connection (supplied with the dishwasher). Old hoses should
not be reused. Failure to install the dishwasher correctly could invalidate any warranty or liability claims.
If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle,
boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS!
Read these instructions completely and carefully. Ensure the product is not plugged in. Installation of custom panels requires basic mechanical and electrical skills. Installation must comply with your local building and electricity regulations. Failure to install the custom panels correctly could invalidate any warranty or liability claims.
SAVE THESE INSTRUCTIONS
Electrical Shock Hazard
WARNING: To reduce the risk of electrical shock, fire, or injury to persons, the installer must ensure that the dishwasher is completely enclosed at the time of installation. Before fitting the front panels and connecting the integrated badges (where present), the installer must ensure that the dishwasher is disconnected from the power supply. After installing the front panel, the installer must ensure that the following components are electrically earthed: the panel bracket, the integrated badge (where present) and any custom metal component (e.g. handle) that extends past the rubber seal.
Failure to follow these warnings may result in electrical shock, injury or fire.
WARNING!
Fitting integrated front panels requires access to electrical service areas. This work must be performed and certified by a qualified electrical service technician.
Page 4
4
PARTS SUPPLIED - ALL MODELS
3a
If the Drain hose supplied is not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose by 3.6m. The kit is available from the nearest Fisher & Paykel Authorised Service Centre or through our local website listed at the end of this document.
Clamp (1) (for securing
Drain hose joiner)
Wire clip (1) (for securing
Drain hose joiner)
Phillips 16 mm screws (7)
38 mm bottom fixing screws & metal washers (2)
Drain hose support (1)
Moisture protection tape (1)
(to prevent moisture damage)
Cavity bracket kit (1)
supplied with Tall height Designer and Integrated models only
Drain hose joiner (1)
Rubber washer for inlet hose (1)
(comes already
fitted)
Side mounting bracket kit (A and B) (2)
OPTIONAL
Page 5
5
ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS
3b
External Venting kit (1)
supplied with Integrated models with remote only
Panel mounting screws (6)
Panel bracket (1)
(attached to product)
Integrated rectangular badge (1)
(Satin chrome supplied)
supplied with Integrated models with badge only
Page 6
6
4
PRODUCT DIMENSIONS
AHI
J
K
Side
Plan
G
F
B
CD
E
Product dimensions (mm)
STANDARD HEIGHT MODELS TALL HEIGHT MODELS
Classic
Designer
Integrated
Remote
control
Integrated
Badge
control
Classic
Designer
Integrated
Remote
control
456 mm cavity
Integrated
Badge
control
456 mm cavity
Integrated
Remote
control
480 mm cavity
Integrated
Badge
control
480 mm cavity
A
overall height1 of product (incl. front panel height) 410 410 410 410 454 478
2
454 454 478
2
478
2
B
overall width of product 599 599 599 599 599 599 599 599 599 599
C
overall depth of product (excl. handle) 582 571 571
3
571
3
582 571 571
3
571
3
571
3
571
3
D
depth of chassis (to back of front panel) 553 553 553 553 553 553 553 553 553 553
E
maximum extension of drawer (excl. handle) 556 545 545
3
545
3
556 545 545
3
545
3
545
3
545
3
F
depth of front panel (excl. handle) 29 18 16-20 16-20 29 18 16-20 16-20 16-20 16-20
G
height1 of chassis 410 410 410 410 454 454 454 454 454 454
H
depth of handle n/a 41 n/a n/a n/a 41 n/a n/a n/a n/a
I
height of front panel 394 398 4084min. 398 438 470 4525min. 442 4765min. 470
J
height of ventilation gap below front panel 7 8 min. 2 min. 8 7 8 min. 2 min. 8 min. 2 min. 8
K
height from top of handle to top of front panel n/a 64 n/a n/a n/a 64 n/a n/a n/a n/a
1
includes 2mm high bracket slots 2Includes cavity bracket 3Assuming front panel thickness of 18 mm
4
Recommended for a 2 mm ventilation gap below panel, if cavity height is 412 mm 5Recommended for a 2 mm ventilation gap below panel
Page 7
7
5
CABINETRY DIMENSIONS
min.
412mm
456mm 480mm
LL L
dishwasher dishwasher dishwasher
Standard height models
Tall height Classic models
Tall height Integrated models
Compact
Oven
Single Oven
Tall height Designer models
Plan
Side
L
N
M
Cavity height options allow you to match dishwasher with your cabinetry or companion products
Minimum clearances from adjacent cabinetry
You may choose to install Tall height Integrated models into either a 456 mm or a 480 mm high cavity. Note: the minimum height of the custom drawer front
panel will also be different for these two options.
Cabinetry dimensions (mm)
STANDARD HEIGHT MODELS TALL HEIGHT MODELS
Classic
Designer
Integrated
Remote
control
Integrated
Badge
control
Classic
Designer
Integrated
Remote
control
456 mm cavity
Integrated
Badge
control
456 mm cavity
Integrated
Remote
control
480 mm cavity
Integrated
Badge
control
480 mm cavity
L
inside height of cavity min. 412 min. 412 min. 412 min. 412 456 480 456 456 480 480
M
inside width of cavity 600 600 600 600 600 600 600 600 600 600
N
inside depth of cavity min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min. 560 min. 560
min. 13 mm clearance from a corner
min. 2 mm clearance to adjacent cupboard door
Page 8
8
The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry:
WIDTH OF THE PANEL
Measure
A (
the width between adjacent door/drawer fronts)
and write it in the  rst box below, then complete the equation.
HEIGHT OF THE PANEL
Measure B and write it in the  rst box below, then complete the equation.
min. 2 mm
min. 2 mm
min. 2 mm ventilation gap with external venting kit installed
min. 2 mm ventilation gap with
external venting kit installed
min. 2 mmmin. 2 mm
WIDTH OF PANEL
HEIGHT OF PANEL
A
B
A
B
clearance to adjacent cabinet front (min. 2 mm)
ventilation gap
(min. 2 mm)
WIDTH OF PANEL
(min. 596 mm)
HEIGHT OF PANEL
- 2x
-
=
=
FRONT PANEL SPECIFICATIONS
16 -20 mm panel thickness Maximum weight of panel: 9 kg Adequately sealed to withstand moisture (50
O
C @ 80% RH). Because of it being a hot and wet environment generally, the back and sides of the panel should be completely sealed with a waterproof vapour barrier (ie polyurethane) to prevent damage to the panel. The back of the panel (including any integrated handle) should be completely flush so that the seal between the panel and the rubber trim is maintained.
6a
Note: when the top of the dishwasher has to be lower than the adjacent cabinetry, the panel can be increased in height.
INTEGRATED MODELS WITH REMOTE ONLY - CUSTOM FRONT PANEL CALCULATIONS
Page 9
9
The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry:
WIDTH OF THE PANEL
Measure
A (
the width between adjacent door/drawer fronts)
and write it in the  rst box below, then complete the equation.
HEIGHT OF THE PANEL
Measure B and write it in the  rst box below, then complete the equation.
min. 2 mm
min. 2 mm
min. 8 mm ventilation gap
min. 8 mm ventilation gap
min. 2 mmmin. 2 mm
WIDTH OF PANEL
HEIGHT OF PANEL
A
B
A
B
clearance to adjacent cabinet front (min. 2 mm)
ventilation gap
(min.8 mm)
WIDTH OF PANEL
(min. 596 mm)
HEIGHT OF PANEL
- 2x
-
=
=
FRONT PANEL SPECIFICATIONS
16 -20 mm panel thickness Maximum weight of panel: 9 kg Adequately sealed to withstand moisture (50
O
C @ 80% RH). Because of it being a hot and wet environment generally, the back and sides of the panel should be completely sealed with a waterproof vapour barrier (ie polyurethane) to prevent damage to the panel. The back of the panel (including any integrated handle) should be completely flush so that the seal between the panel and the rubber trim is maintained.
6b
Note: when the top of the dishwasher has to be lower than the adjacent cabinetry, the panel can be increased in height.
INTEGRATED MODELS WITH BADGE ONLY - CUSTOM FRONT PANEL CALCULATIONS
Page 10
10
7a
CAVITY PREPARATION
Water Connection
Recommended COLD (Maximum 60°C).
¾ “ BSP (GB20) to suit flat washer.
Water Pressure
Water softener models
Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi)
Models without water softener
Max. 1 MPa (145 psi) Min. 0.03 MPa (4.3 psi)
Important!
Adjacent cabinetry must not extend above cavity base
Important!
The power outlet must be located in a cabinet adjacent to the dishwasher cavity.
220-240 VAC min. 4.8 A
min.
ø
60 mm
min. 200 mm
Moisture
protection
tape must
be applied.
Services can be located either side of the dishwasher.
These marks indicate formed bracket screw locations, if securing by drawer removal.
10 mm
BENCHTOP
Page 11
11
7b
7c
ø
60 mm
ø
60 mm
max.
5 mm
max.
5 mm
220 mm
220 mm
100 mm
100 mm
ø
60mm
Services can be located either side of dishwasher
VENT HOSE
VENT HOSE & SERVICES
SERVICES
Services can be located either side of dishwasher
Shelf cutouts
Shelf cutouts
The ø60 mm services hole should be enlarged to accomodate the extra venting hose by cutting out some material from the bottom corner.
External Venting kit (1)
External Venting kit (1)
INTEGRATED MODELS WITH REMOTE ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET
INTEGRATED MODELS WITH REMOTE ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET
min. 100 mm
min.100 mm
Important!
To prevent pooling of condensation from the vent hose, a toekick height of no less than 100 mm is required.
Important!
To prevent pooling of condensation from the vent hose, a toekick height of no less than 100 mm is required.
Page 12
12
8
MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE
Left hand side Right hand side
Drain hose - 2000 mm
Inlet hose - 1650 mm
Venting hose - 1525 mm
(Integrated wireless models only) (Integrated wireless models only)
Venting hose - 1925 mm
Power cord
(excl. plug)
- 1650 mm
Drain hose - 1800 mm
Inlet hose - 1250 mm
Power cord
(excl. plug)
- 1650 mm
Drain hose - 2000 mm
Drain hose - 1800 mm
Inlet hose - 1650 mm
Inlet hose - 1250 mm
Venting hose - 1525 mm
Venting hose - 1925 mm
(Integrated models with remote (NZ AU) only)
(Integrated models with remote (NZ AU) only)
Power cord (excl. plug) - 1650 mm
Power cord (excl. plug) - 1650 mm
Page 13
13
TALL HEIGHT DESIGNER & INTEGRATED MODELS FOR 480 mm CAVITY ONLY - ATTACH CAVITY BRACKET
9
The enclosed cavity bracket is  tted before installation in order to conceal the gap at the top of the cavity left after installation.
2
1
Ensure the cavity panel bracket is positioned so that the “F” arrow is pointing towards the front of the chassis.
Firmly push the bracket so that the prongs engage with the top tabs and it clicks into place.
Ensure the top trim seal is facing forward after attaching the bracket.
Important!
Ensure the prongs have not been driven down into the chassis as this will damage the lid below.
12
Page 14
14
RECOMMENDED METHOD (a) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY)
11a10a
ATTACH SIDE MOUNTING BRACKETS
Fitted Elbow
Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity.
The mounting slots are in pairs, one on each side diagonally across the product. A bracket must match A slot and B bracket must match B slot.
Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the venting hose is securely attached to it.
NOW CHOOSE WHICH INSTALLATION METHOD (a) or (b)
IS MORE SUITABLE FOR YOUR CABINETRY...
B
B
B
A
A
A
A
B
INTEGRATED MODELS WITH REMOTE ONLY ­ATTACH VENTING HOSE
Page 15
15
12a 13a
PULL THROUGH HOSES & MOVE INTO THE CAVITY SECURE THE DRAWER
As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted.
Important!
If product cannot be pushed in far enough, pull out again and rearrange hoses and cord. Do not use excessive force, as doing so may squash the hoses and lead to incorrect operation.
vent either through same cabinet or adjacent cabinet as per step 7b or 7c
1
32
Open the
drawer halfway.
Using a flat-bladed
screwdriver, prise
the grey
rubber plug out
of the trim moulding.
Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward.
Repeat for all four brackets.
Using a small Philips
screwdriver,
screw through the trim
moulding, securing the
side mounting bracket
to the cabinetry.
Do not damage the
rubber trimseal.
14a
2
1
After routing the vent hose through and out the hole cutout, attach and secure the vent by tightening the four screws provided.
Airflow
Vent Hose (Integrated models with remote (NZAU) only)
INTEGRATED MODELS WITH REMOTE ONLY - SECURE THE EXTERNAL VENT
Page 16
16
11b10b
PULL THROUGH HOSES & MOVE INTO THE CAVITY
Fitted Elbow
Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the venting hose is securely attached to it.
vent either through same cabinet or adjacent cabinet as per step 7b or 7c
ALTERNATIVE METHOD (b) - SECURE BY DRAWER REMOVAL
INTEGRATED MODELS WITH REMOTE ONLY ­ATTACH VENTING HOSE
As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted.
Important!
If product cannot be pushed in far enough, pull out again and rearrange hoses and cord. Do not use excessive force, as doing so may squash the hoses and lead to incorrect operation.
Vent Hose (Integrated models with remote (NZAU) only)
Page 17
17
12b 13b
14b 15b
REMOVE THE DRAWER SECURE THE DRAWER TO THE CABINETRY
REFIT THE DRAWER ONTO THE RUNNERS
2
1
4
5
3
Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.
Ensure the release tabs on both sides are reset fully.
Ensure the drawer is now rotated clockwise back.
2
100 mm
1
3
4
5
100 mm
To prevent kinked hoses, we recommend rotating the drawer anti-clockwise and resting it on its side after removal.
Press the release tabs in on either side and push back to release drawer from runners
Push drawer runners back in.
Product may move. Mark chassis position on cavity
1
2
The product has three pairs of fixing points:
Ensure the sound insulation is repositioned correctly.
a pair of fixing holes either side on the bottom (use 38 mm fixing screws & washers)
two pairs of formed brackets on either side of the chassis (use 16 mm screws)
2
1
After routing the vent hose through and out the hole cutout, attach and secure the vent by tightening the four screws provided.
Airflow
Pull forward the release tabs on both sides 100
mm
INTEGRATED MODELS WITH REMOTE ONLY ­SECURE THE EXTERNAL VENT
Page 18
18
1
2
16 mm x6
2
2
1
Important!
Ensure the rubber seal between the drawer and panel is kept in place.
REMOVE BRACKET FROM PRODUCT
ATTACH PANEL TO PRODUCT
ATTACH PANEL TO PANEL BRACKET
There must be at least
3 screws used each side
When refitting the door pins, ensure they are orientated as shown.
Align bottom of panel
with bottom of bracket
16a
18a
17a
19a
INTEGRATED MODELS WITH REMOTE ONLY - INSTALLING THE FRONT PANEL
1
1
2
3
Electrical Shock Hazard
Before continuing, ensure that the product is disconnected from the power supply.
Failure to follow this warning may result in electrical shock, injury or re.
WARNING!
EARTH THE PANEL
WARNING!
WARNING!
To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g. handle) that extends past the rubber seal must be earthed too.
Failure to follow these warnings may result in electrical shock, injury or  re.
Electrical Shock Hazard
Repeat for the other drawer
Page 19
19
ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS
With the front panel fitted, insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panel up or down to align the gaps in your cabinetry.
Repeat on the other side if necessary.
The panel has a maximum travel of 2 mm up or down.
Important!
Ensure that you maintain a minimum of 2 mm ventilation gap below the panel.
+ or - 2 mm
20a
INTEGRATED MODELS WITH REMOTE ONLY - INSTALLING THE FRONT PANEL
Page 20
20
1
2
16 mm x6
DETERMINE BADGE CUTOUT LOCATION
ROUTE BADGE WIRING THROUGH PANEL ATTACH PANEL TO PANEL BRACKET
REMOVE BRACKET & DISCONNECT BADGE
16b
18b 19b
17b
There must be at least
3 screws used each side
Align bottom of panel
with bottom of bracket
228.5 mm
228.5 mm
127 mm
255 mm
30 mm
25 mm
1
3
4
1
2
1
2
Badge zone
INTEGRATED MODELS WITH BADGE ONLY - INSTALLING THE FRONT PANEL & BADGE CONTROLS
Electrical Shock Hazard
Before continuing, ensure that the product is disconnected from the power supply.
Failure to follow this warning may result in electrical shock, injury or re.
WARNING!
Page 21
21
2
2
1
ATTACH PANEL TO PRODUCT
ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS
20b
22b
21b
With the front panel fitted, insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panel up or down to align the gaps in your cabinetry.
Repeat on the other side if necessary.
The panel has a maximum travel of 2 mm up or down.
Important!
Ensure that you maintain a minimum of 8 mm ventilation gap below the panel.
+ or - 2 mm
Important!
Ensure the rubber seal between the drawer and panels is kept in place.
When refitting the door pins, ensure they are orientated as shown.
Push the panel in then up to locate.
INTEGRATED MODELS WITH BADGE ONLY - INSTALLING THE FRONT PANEL & BADGE CONTROLS
REATTACH BADGE & EARTH THE PANEL
1
2
WARNING!
Electrical Shock Hazard
Connect the integrated badge earth wire to one of the two tabs provided on the panel bracket.
To earth the panel bracket, connect the earth wire from the product to the other tab. Any custom metal component (e.g. handle) that extends past the rubber seal must be earthed too.
Failure to follow these warnings may result in electrical shock, injury or  re.
Page 22
22
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE.
23
1
3
2
750-882.5 mm
1
2
38 mm
max. 120 mm
750-882.5 mm
**
3 4
5
If space is limited for fixing, push hose through drain hose support to required height
If space is limited for fixing, push hose through drain hose support to required height
Dishwasher using sink trap with drain hose joiner
750 - 882.5 mm
750 - 882.5 mm
min. R 200 mm
min. R 200 mm
Supplied drain hose joiner 19 mm waste tee
HIGHLOOP
min. 150 mm
Ensure drain hose is routed straight to joiner. Remove excess drain hose material if necessary.
Do not shorten the inlet hose.
Dishwasher and Standpipe Ø 38 mm
Ensure the supplied rubber washer is fitted inside the coupling.
Tighten coupling with spanner.
180
o
No leaks!
CONNECT INLET HOSE TO COLD WATER PLUG PRODUCT IN
24 25
1 2
24 24see see
Important!
Do not connect the drain hose to a waste disposal unit, as this type of connection may lead to a blockage in the drain hose.
Page 23
23
27
26
FINAL CHECKLIST TROUBLESHOOTING
Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have
been conducted in accordance with local electrical regulations.
Ensure product is level, securely fastened to the cabinetry and opens and
closes freely. The drawer must be free to fully close with no resistance from the
cabinetry.
Ensure inlet hose to water supply has supplied rubber washer fitted, and that
it’s tightened a further half turn after seal contact.
Ensure any knockouts or plugs in drain connection have been drilled out and
drain connection has been made.
The drain hose joiner must not support the weight of excess hose material.
Keep drain hose as fully extended as possible to prevent sagging. Any excess
length of drain hose should be kept on the dishwasher side of the highloop.
If connecting the drain hose to the sink trap, ensure the Highloop is a minimum
150 mm higher than the drain hose joiner.
Ensure any packaging or tape securing the racks is removed from the drawer.
Turn on the power and water supplies, then open the drawer. You should hear a
beep and see a program indicator light up on the internal control panel.
Check the spray arm is in place and free to rotate.
Add three cups of water into the drawer. Press
on the internal control panel
until the indicator of the ‘Rinse’ program lights up. Close the drawer and press
to start the program.
After the Rinse program has finished, ensure the dishwasher has run and
drained correctly.
Check water supply and drainage connection for leakage.
Spray arm
Excessive water remaining above the filter plate, after the rinse cycle
Check for a kinked drain hose, blocked waste connection, highloop not properly installed, drain hose not routed correctly or spray arm not in place.
No water supply (This is displayed as a ‘U1’ fault -- see section ‘If there is a fault’ in the User guide for how to recognise this fault on models without a display.)
Check water is connected and turned on.
The dishwasher is beeping continuously
There is a fault. See section ‘If there is a fault’ in the User guide for further
information and instructions.
No program indicator lights up when the drawer is opened
Ensure power is connected and is switched on. If it is and still no indicator ligths up, see the ‘Preference options’ section of the ‘Quick start guide’. An option called ‘Open drawer auto power-on’ may need to be turned on.
Water around water supply and drainage connections
Check connections, existing plumbing and hoses for leaks. Check rubber washer and hose clamp are correctly fitted.
If product is tipping
Ensure the product is secured to the cabinetry.
If front panels are misaligned
Check and relevel product. Check the cabinetry is square. For Integrated models, check and adjust front panel alignment if necessary.
Drawer doesn’t close properly
Ensure nothing is obstructing the drawer from closing properly eg sound insulation, hoses or drawer latches. If a problem occurs, consult the ‘Troubleshooting’ section of the User guide. If after checking these points you still need assistance, please refer to the Service & Warranty book for warranty details and your nearest Authorised Service Centre, or contact us through our website, listed below.
Important!
SAVE THESE INSTRUCTIONS
The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our website listed at the end of this document or contact your local Fisher & Paykel dealer.
www. sherpaykel.com