Fisher Paykel CPV2485GDLN Planning guide

48" PROFESSIONAL
COOKTOPS & BACKGUARDS
CPV2-485, CPV2-486GD, CPV2-486GL, CPV2-488,
BGCV2-1248, BGCV2-3048, BGCV2-3048H models
PLANNING GUIDE
CONTENTS
48" Professional Cooktop CPV2-485, CPV2-486GD, CPV2-486GL, CPV2-488
Key Design Decisions 5 23
Ventilation Requirements 6 24
48" Professional Cooktop CPV2-485
Product & Cavity Dimensions 7 25
Clearance Dimensions 8 26
Cavity Preparation 9 27
48" Professional Cooktop CPV2-486GL
Product & Cavity Dimensions 10 28
Clearance Dimensions 11 29
PAGE
in mm
Cavity Preparation 12 30
48" Professional Cooktop CPV2-486GD
Product & Cavity Dimensions 13 31
Clearance Dimensions 14 32
Cavity Preparation 15 33
CONTENTS (continued)
48" Professional Cooktop CPV2-488
Product & Cavity Dimensions 16 34
Clearance Dimensions 17 35
Cavity Preparation 18 36
48" Professional Range Backguard BGCV2-1248
Product Dimensions 19 37
48" Professional Range Backguard BGCV2-3048
Product Dimensions 20 38
PAGE
in mm
48" Professional Range Backguard BGCV2-3048H
Product Dimensions 21 39
IMPERIAL
KEY DESIGN DECISIONS
48" Professional Range
1
INSTALL TYPE
WALL
2
REAR SURFACE
COMBUSTIBLE
3
BACKGUARD OPTIONS
NO BACKGUARD
MIN 6"
CLEARANCE
Model no:
CPV2-485, CPV2-486GD,
CPV2-488, CPV2-486GL
HIGH SHELF
HIGH BACKGUARD
BGRV2-1248
BGCV2-3048H
BGCV2-3048
LOW SHELF
HIGH BACKGUARD
ISLAND
NON COMBUSTIBLE
NO BACKGUARD
LOW BACKGUARD
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
MIN 30"
CUSTOM FABRICATED* BACKGUARD
*Fabricated from non combustible materials only
CUSTOM
BACKGUARD*
MAX 15/16"
VENTILATION REQUIREMENTS
Wall Installation
2'' Deep x Unit Width
1200 CFM
Island Installation
0'' Deep x Unit Width
1200 CFM
48" Professional Gas Cooktop
1
INSTALL TYPE
WALL
HOOD SURROUND MATERIAL
23"
NON COMBUSTIBLE
30"
MIN 30" MAX 36"
2
23"
COMBUSTIBLE
30"
MIN 36"
Model no:
CPV2-485, CPV2-486GD,
CPV2-488, CPV2-486GL
Note: CPV2-66 illustrated but all dimensions apply to the above models
Specifications
Ventilation Unit
Hood
Blower
Ventilation Unit
Hood
Blower
Note: A suitable hood must be installed above the cooktop. The above indicates the minimum blower capacity recommended for hood ventilation.
ISLAND
MIN 30" MAX 36"
NON COMBUSTIBLE
COMBUSTIBLE
MIN 36"
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CABINET FACE FOR
in
8''
9 15/16''
47 7/8''
28 1/8''
1 15/16''
/8''
8 /8''
24 /16''
''
2 1/2''
''
10 1/2''
1 5/8''
in
8''
min 48''
max
24 /16''
max
26 11/16''
INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
C
47 7/8''
D
28 1/8''
PRODUCT & CAVITY DIMENSIONS
48" Professional Gas Cooktop
Model no:
CPV2-485
Product Dimensions
A Height below countertop datum to bottom of chassis
B Overall height of product (bottom of chassis to top of grates)
C Overall width of cooktop
D Overall depth of cooktop
E Height above countertop datum to top of grates
F Height from countertop datum to chassis top surface
G Height of chassis
H Depth from rear of chassis to cabinetry datum - projecting
I Depth from rear of chassis to cabinetry datum - flush
J Depth of control panel
K Distance from left edge of chassis to center line of gas inlet
L Distance from left edge of chassis to center line of power cord
M Distance from rear edge of chassis to center line of gas/power
26 11/16
DATUM :
TOP OF COUNTERTOP
DATUM :
CABINET SURFACE BELOW COOKTOP
B
K
L
0 5 10 20
inches
PLAN VIEW
FRONT VIEW
E
F
A
8''
J
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
H
I
PROFILE VIEW
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
Cutout Dimensions
Overall height of cutout
Overall width of cutout
Overall depth of cutout for projecting control panel
Overall depth of cutout for flush control panel
G
M
INDICATES CABINETRY DATUM -----------------------------------------
INDICATES CUTOUT -------------------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
in
48''
18''
12''
54''
6'' 0''
1''
MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
MINIMUM CLEARANCE:
CC
NEAREST VERTICAL COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
D
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
E
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
D
VENTILATION HOOD
MINIMUM CLEARANCE:
D
NON-COMBUSTIBLE SURFACE
CLEARANCE DIMENSIONS
48" Professional Gas Cooktop
Model no:
CPV2-485
Cabinetry Dimensions
A Minimum width of ventilation hood installed above cooktop
- not shown*
B Minimum vertical distance between countertop and cabinet
extending above counter
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
D Minimum clearance from cooking surface to:
– combustible surface centered above the cooking surface – combustible covering for ventilation hood centered above
the cooking surface
– non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
0 5 10 20
inches
PLAN VIEW
MINIMUM CLEARANCE:
B
ADJACENT OVERHEAD CABINET
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
in
8''
min 48''
max
24 /16''
max
26 11/16''
in
6''
12''
48" Models
120 VAC, 60Hz
15 amp
15 amp circuit
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
48" Professional Gas Cooktop
Model no:
CPV2-485
Cavity Dimensions
A Overall height of cutout
C
e
D
ELECTRICAL & GAS SUPPLY CUTOUT
A
B
B Overall width of cutout
C Overall depth of cutout for projecting control panel
Overall depth of cutout for flush control panel
Electrical and Gas Supply Cutout
D Depth of supply area from rear of cutout
E Width of supply area from left side of cutout
Specifications
Electrical
Supply
Max. Current Draw
Service
Gas – Natural
Connection
Supply Pressure
Gas – LP
Connection
Supply Pressure*
A regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the cooktop regulator.
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CABINET FACE FOR
in
8''
9 15/16''
47 7/8''
28 1/8''
1 15/16''
/8''
8 /8''
24 /16''
''
2 1/2''
''
10 1/2''
1 5/8''
in
8''
min 48''
max
24 /16''
max
26 11/16''
INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
C
47 7/8''
D
28 1/8''
PRODUCT & CAVITY DIMENSIONS
48" Professional Gas Cooktop
Model no:
CPV2-486GD
Product Dimensions
A Height below countertop datum to bottom of chassis
B Overall height of product (bottom of chassis to top of grates)
C Overall width of cooktop
D Overall depth of cooktop
E Height above countertop datum to top of grates
F Height from countertop datum to chassis top surface
G Height of chassis
H Depth from rear of chassis to cabinetry datum - projecting
I Depth from rear of chassis to cabinetry datum - flush
J Depth of control panel
K Distance from left edge of chassis to center line of gas inlet
L Distance from left edge of chassis to center line of power cord
M Distance from rear edge of chassis to center line of gas/power
26 11/16
DATUM :
TOP OF COUNTERTOP
DATUM :
CABINET SURFACE BELOW COOKTOP
B
K
L
0 5 10 20
inches
PLAN VIEW
FRONT VIEW
E
F
A
8''
J
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
H
I
PROFILE VIEW
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
Cutout Dimensions
Overall height of cutout
Overall width of cutout
Overall depth of cutout for projecting control panel
Overall depth of cutout for flush control panel
G
M
INDICATES CABINETRY DATUM -----------------------------------------
INDICATES CUTOUT -------------------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
in
48''
18''
12''
54''
6'' 0''
1''
MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
MINIMUM CLEARANCE:
CC
NEAREST VERTICAL COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
D
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
E
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
D
VENTILATION HOOD
MINIMUM CLEARANCE:
D
NON-COMBUSTIBLE SURFACE
CLEARANCE DIMENSIONS
48" Professional Gas Cooktop
Model no:
CPV2-486GD
Cabinetry Dimensions
A Minimum width of ventilation hood installed above cooktop
- not shown*
B Minimum vertical distance between countertop and cabinet
extending above counter
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
D Minimum clearance from cooking surface to:
– combustible surface centered above the cooking surface – combustible covering for ventilation hood centered above
the cooking surface
– non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
0 5 10 20
inches
PLAN VIEW
MINIMUM CLEARANCE:
B
ADJACENT OVERHEAD CABINET
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
in
8''
min 48''
max
24 /16''
max
26 11/16''
in
6''
12''
48" Models
120 VAC, 60Hz
15 amp
15 amp circuit
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
48" Professional Gas Cooktop
Model no:
CPV2-486GD
Cavity Dimensions
A Overall height of cutout
C
e
D
ELECTRICAL & GAS SUPPLY CUTOUT
B Overall width of cutout
C Overall depth of cutout for projecting control panel
Overall depth of cutout for flush control panel
Electrical and Gas Supply Cutout
D Depth of supply area from rear of cutout
E Width of supply area from left side of cutout
A
Specifications
Electrical
Supply
B
Max. Current Draw
Service
Gas – Natural
Connection
Supply Pressure
Gas – LP
Connection
Supply Pressure*
A regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the cooktop regulator.
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation manual for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
Loading...