Fisher Paykel CPV2366NN Planning guide

36" PROFESSIONAL
COOKTOPS & BACKGUARDS
CPV2-364GD, CPV2-366,
BGCV2-1236, BGCV2-3036 & BGCV2-3036H models
PLANNING GUIDE
CONTENTS
Key Design Decisions
Ventilation Requirements
36" Professional Cooktop CPV2-364GD
Product & Cavity Dimensions 6 18
Clearance Dimensions 7 19
Cavity Preparation 8 20
36" Professional Cooktop CPV2-366
Product & Cavity Dimensions
Clearance Dimensions
Cavity Preparation
PAGE
in mm
4 16
5 17
9 21
10 22
11 23
36" Professional Range Backguard BGCV2-1236
Product Dimensions 12 24
36" Professional Range Backguard BGCV2-3036
Product Dimensions 13 25
36" Professional Range Backguard BGCV2-3036H
Product Dimensions 14 26
IMPERIAL
KEY DESIGN DECISIONS
6" Professional Gas Cooktop
1
INSTALL TYPE
WALL
2
REAR SURFACE
COMBUSTIBLE
3
BACKGUARD OPTIONS
NO BACKGUARD
MIN 6"
CLEARANCE
Model no:
CPV2-364GD, CPV2-366
BGCV2-3036H
BGCV2-3036
HIGH SHELF BACKGUARD
LOW SHELF BACKGUARD
BGRV2-1236
ISLAND
NON COMBUSTIBLE
NO BACKGUARD
LOW BACKGUARD
DATE: 02.05.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CUSTOM
BACKGUARD*
MIN 30''
MAX 15/16''
CUSTOM FABRICATED* BACKGUARD
*Fabricated from non combustible materials only
VENTILATION REQUIREMENTS
Wall Installation
2'' Deep x Unit Width
600 CFM
Island Installation
0'' Deep x Unit Width
600 CFM
Wall and Island Installation
Unit Width
600 – 1200 CFM
6" Professional Gas Cooktop
1
INSTALL TYPE
WALL
HOOD SURROUND MATERIAL
23"
MIN 30" MAX 36"
NON COMBUSTIBLE
30"
2
23"
COMBUSTIBLE
30"
MIN 36"
Model no:
CPV2-364GD, CPV2-366
Note: CPV2-66 illustrated but all dimensions apply to the above models
Specifications
Ventilation Unit
Wall Chimney Hood
Blower
Ventilation Unit
Island Chimney Hood
Blower
Ventilation Unit
Downdraft*
Blower
Note: A suitable ventilation unit must be installed with the cooktop. The above indicates the minimum blower capacity recommended for ventilation units.
* Not illustrated.
ISLAND
MIN 30" MAX 36"
NON COMBUSTIBLE
COMBUSTIBLE
MIN 36"
DATE: 02.05.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CABINET FACE FOR
in
8''
9 15/16''
5 7/8''
28 1/8''
1 15/16''
/8''
8 /8''
24 /16''
''
2 1/2''
2 1/2''
10 1/2''
1 5/8''
in
8''
min 6''
max
24 /16''
max
26 11/16''
INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
DATUM :
CABINET SURFACE BELOW COOKTOP
PRODUCT & CAVITY DIMENSIONS
6" Professional Gas Cooktop
Model no:
CPV2-364GD
Product Dimensions
A Height below countertop datum to bottom of chassis
B Overall height of product (bottom of chassis to top of grates)
C Overall width of cooktop
D Overall depth of cooktop
E Height above countertop datum to top of grates
F Height from countertop datum to chassis top surface
G Height of chassis
H Depth from rear of chassis to cabinetry datum - projecting
I Depth from rear of chassis to cabinetry datum - flush
J Depth of control panel
K Distance from left edge of chassis to center line of gas inlet
L Distance from left edge of chassis to center line of power cord
M Distance from rear edge of chassis to center line of gas/power
26 11/16
C
D
28 1/8''
5 7/8''
PLAN VIEW
Cutout Dimensions
Overall height of cutout
Overall width of cutout
E
B
A
F
8''
Overall depth of cutout for projecting control panel
Overall depth of cutout for flush control panel
G
K
L
J
H
I
FRONT VIEW
0 5 10 20
inches
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
PROFILE VIEW
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
M
INDICATES CABINETRY DATUM -----------------------------------------
INDICATES CUTOUT -------------------------------------------------------
DATE: 02.05.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
in
6''
18''
12''
54''
6'' 0''
1''
MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
MINIMUM CLEARANCE:
CC
NEAREST VERTICAL COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
D
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
E
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
D
VENTILATION HOOD
MINIMUM CLEARANCE:
D
NON-COMBUSTIBLE SURFACE
CLEARANCE DIMENSIONS
6" Professional Gas Cooktop
Model no:
CPV2-364GD
Cabinetry Dimensions
A Minimum width of ventilation hood installed above cooktop
- not shown*
B Minimum vertical distance between countertop and cabinet
extending above counter
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
D Minimum clearance from cooking surface to:
– combustible surface centered above the cooking surface – combustible covering for ventilation hood centered above
the cooking surface
– non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
0 5 10 20
inches
PLAN VIEW
MINIMUM CLEARANCE:
B
ADJACENT OVERHEAD CABINET
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 02.05.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
in
8''
min 6''
max
24 /16''
max
26 11/16''
in
6''
12''
6" Models
120 VAC, 60Hz
15 amp
15 amp circuit
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
6" Professional Gas Cooktop
Model no:
CPV2-364GD
Cavity Dimensions
A Overall height of cutout
B Overall width of cutout
C Overall depth of cutout for projecting control panel
C
ELECTRICAL & GAS SUPPLY CUTOUT
Overall depth of cutout for flush control panel
Electrical and Gas Supply Cutout
D Depth of supply area from rear of cutout
E Width of supply area from left side of cutout
e
D
A
Specifications
Electrical
Supply
Max. Current Draw
Service
B
Gas – Natural
Connection
Supply Pressure
Gas – LP
Connection
Supply Pressure*
A regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the cooktop regulator.
DATE: 02.05.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CABINET FACE FOR
in
8''
9 15/16''
5 7/8''
28 1/8''
1 15/16''
/8''
8 /8''
24 /16''
''
2 1/2''
2 1/2''
10 1/2''
1 5/8''
in
8''
min 6''
max
24 /16''
max
26 11/16''
INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
DATUM :
CABINET SURFACE BELOW COOKTOP
PRODUCT & CAVITY DIMENSIONS
36" Professional Gas Cooktop
Model no:
CPV2-366
Product Dimensions
A Height below countertop datum to bottom of chassis
B Overall height of product (bottom of chassis to top of grates)
C Overall width of cooktop
D Overall depth of cooktop
E Height above countertop datum to top of grates
F Height from countertop datum to chassis top surface
G Height of chassis
H Depth from rear of chassis to cabinetry datum - projecting
I Depth from rear of chassis to cabinetry datum - flush
J Depth of control panel
K Distance from left edge of chassis to center line of gas inlet
L Distance from left edge of chassis to center line of power cord
M Distance from rear edge of chassis to center line of gas/power
26 11/16
C
D
28 1/8''
5 7/8''
PLAN VIEW
Cutout Dimensions
Overall height of cutout
Overall width of cutout
E
B
A
F
8''
Overall depth of cutout for projecting control panel
Overall depth of cutout for flush control panel
G
K
L
J
H
I
FRONT VIEW
0 5 10 20
inches
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
PROFILE VIEW
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
M
INDICATES CABINETRY DATUM -----------------------------------------
INDICATES CUTOUT -------------------------------------------------------
DATE: 02.05.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com