IMPORTANT SAFEGUARDS
To prevent overflows, make sure the dispenser is completely
empty before brewing.
Always remove the funnel for manual filling of the dispenser.
Do not use bleach or cleaners containing chlorides.
Use only non-metallic brushes and cleaning pads.
Use only the handle to lift or carry the dispenser.
Do not use the faucet guard to pull or lift the dispenser.
Do not submerge the brew funnel.
CLEANING AND MAINTENANCE
Daily:
Important Notice: To maintain proper operation of the funnel display, clean the funnel stem daily under running water with detergent and a sponge or towel. Do not submerge.
Use any commercial beverage urn cleaner to clean the inside of
the dispenser. Follow the cleaner manufacturer’s instructions. Make sure to thoroughly rinse the dispenser after cleaning.
Wash the drip tray and other plastic parts with dish detergent.
Avoid abrasives.
To sanitize the dispenser before filling, brew a batch of water only
(no coffee) into the dispenser and allow it to rest for 10 minutes.
Weekly, or as needed:
Remove the faucet upper assembly and inspect the seat cup for
wear. Clean or replace if necessary.
BREW FUNNEL DISPLAY
(Display updates every 6 seconds.)
Freshness Timer Volume Display
= 15 minutes.
= 1 hour.
- flashing -
Timer is reset when dispenser is completely emptied, when funnel is removed, or when enough liquid is added to increase the volume by at
= Maximum time has elapsed. (4 hrs.)
- Each bar equals ¼ gallon.
- “V” section is 1
st
bar.
- Example shown is L3D-15. L3D-10 has 4 bars. L3D-15 has 6 bars. L3D-20 has 8 bars.
least one level.
Examples for L3D-15:
15 minutes
Full
1 hour, 45 minutes
¾
Half full –
gallon
3 hours, 30 minutes
¼
gallon
Troubleshooting:
- flashing -
- flashing -
Problem: “V” segment of volume display is
flashing slowly.
Cause: Funnel stem is dirty.
Solution: Clean funnel stem with detergent
and a s
e or towel.
Problem: Every other bar of volume display
is flashing slowly.
Cause: Battery power is low or internal
malfunction.
Solution: Replace with new funnel.
Battery cannot be replaced.
OPENING THE DISPENSER
Squeeze tabs together and lift.
OPENING AND CLOSING THE COVER PLUG
Closed
position
for serving
Open
position
for brewing
REMOVING THE BREW FUNNEL
REMOVING THE DRIP TRAY
Important Notice: To maintain proper operation of the funnel display, clean the funnel stem daily under running water with detergent and a sponge or towel. Do not submerge.
Brew funnel must be removed
for manual filling of dispenser.
Removing the funnel resets
the timer.
To extend battery life, remove
the funnel when not in use. (Battery cannot be replaced.)
latch
release
Press and hold down latch release while sliding drip tray out.
REMOVING THE FAUCET GUARD
Unscrew knob 4 turns and slide faucet guard out.
REMOVING THE FAUCET
knob
Press faucet release latch up.
Rotate faucet 180° and pull it out.
Unscrew faucet upper assembly to clean or replace seat cup.
Reverse procedure to re­install faucet. Press release latch down to lock faucet in place.
Replacement Parts
L3D-10 L3D-15 L3D-20
Part #
funnel assembly, with gasket K001 K002 K003
funnel gasket 24053 24056 24056
faucet guard 23166 23137 23137
faucet guard knob, w/washer K010 K010 K010
faucet assembly, complete K011 K011 K011
faucet upper assembly
(black handle, seat cup, spring assy.)
faucet handle, black 71028 71028 71028
faucet handle, orange 71027 71027 71027
faucet handle, red 71080 71080 71080
faucet handle, green 71085 71085 71085
faucet seat cup 71035 71035 71035
drip tray assembly
(tray & cover)
K013 K014 K014
www.fetco.com
640 Heathrow Drive, Lincolnshire, IL 60069 USA
Phone: (847) 719-3000 Fax: (847) 821-1178 e-mail: sales@fetco.com
Part # Part #
71037 71037 71037
Loading...