t
∫
Touch Function Selector Technology
f
NOTICE TO INSTALLER: Please leave this book with the machine.
®
User’s Guide
HWD-2110
Hot Water Dispenser
Temperature On Demand US design patent applied for. Other Temperature On Demand US patents applied for.
FETCO®, is a trademark of Food Equipment Technologies Company.
© 2011 Food Equipment Technologies Company Part Number P117 April 2013
FETCO® Hot Water Dispenser
FETCO®
Food Equipment Technologies Company
600 Rose Road
Lake Zurich • IL • 60047-0429 • USA
Internet: www.fetco.com
Phone: (800) 338-2699 (US & Canada)
(847) 719-3000
Fax: (847) 719-3001
Email: sales@fetco.com
techsupport@fetco.com
Description & Features
Contact Information
Water temperature selectable to 158°-204°F/70-96°C English and Metric temperature ranges selectable
Maximum single dispense is 24ounces/700cc in 15 seconds maximum dispense time
Non-Temperature on Demand and Temperature on Demand (TOD) configurations is available as separate equipment.
Specifications
.
Electrical Configurations-DOMESTIC
Configuration
Code
H211011 1 X 5 kW 200-240 1 2+G NEMA 6-30P plug 3.6-5.1 17.4-21 9.5-13.5gallon*/36-51 liter
H211021 1 X 5 kW 200-240 1 2+G Cord Only† 3.6-5.1 17.4-21 9.5-13.5gallon*/36-51 liter
*NOTE: Temperature ranges selectable from 158°-204°F/70-96°C based on 207°F/97°C hot water tank temperature. † For EXPORT, Cord without plug will be attached
Temperature of dispensed hot water may vary up to 3 ½ % of displayed temperature selection.
*Flow rate per hour based on 65-70°F/18-21°C mains water supply temperature at lowest possible electrical supply current
*Factors affecting temperature accuracy include quantity of hot water dispensed, ambient air temperature, distance of container from hot water faucet (pouring over longer distance causes more cooling)
Water Requirements:
Dispenser Model Height Width Depth Water tank capacity Empty Weight Filled Weight Shipping Weight
Heater
Configuration
Voltage Phase Wires
Electrical
Connection
Electrical Configurations-EXPORT & CANADA
Pressure: 40-75 psig, (276-517kPa)
Minimum Flow Rate: 1½gpm (5.7lpm)
Water connection inlet: ¼ inch male flare fitting.
Weights and Capacities
KW
Maximum
Amp Draw
Power Plug Configurations
NEMA PLUG CONFIGURATION
NEMA 6-30P
Gallons/Hour
HWD-2110 24 1/2 in/62 cm 10 in/25.4 cm 19 1/2 in/49.5 cm 4.6 gallon/17.4 liter 30 lbs/13.6 kg 68.3 lbs/31 kg 44 lbs/20 kg
NEW TECHNOLOGICAL FEATURES
The FETCO hot water dispenser uses new
t
The
∫
Touch Function Selector buttons (above and below display screen) alternately dim and brighten when selection is not active.
f
Dispensing and Feature Selections activate when touched. The front panel is clean and uncluttered.
Programming, display and error codes are interactive and more intuitive.
Float indicator is built into drip tray to help simplify maintenance and cleaning.
NOTE:
The HWD-2110 Digital Hot Water Dispenser cannot be modified into a HWD-2110 TOD Temperature on Demand Hot Water Dispenser
t
∫
Touch Function Selector Technology to operate the hot water dispenser.
f
2
Dimensions & Utility Connections
Drawing # 1201.00004.00
Water inlet fitting: ¼ inch male flare fitting
The installation must comply with applicable federal, state, and local codes having jurisdiction at your location. Utilize only
qualified beverage equipment service technicians for installation.
A Service Company Directory may be found on our website, http://www.fetco.com.
Setup
1. Before placing the unit, verify that it will fit in the space intended for it, and that
the counter or table will support the weight of the HWD-2110 when filled.
2. When the unit is in position, use a bubble level to level it front to back and side
to side by adjusting the legs.
Water Connection
1. Water inlet is a ¼ inch male flare fitting.
2. Install a shut off valve near the unit to facilitate service.
3. Install a backflow prevention device, a spring loaded double check valve such as a
WATTS® SD-2 or SD-3, two models accepted by most zoning authorities.
The check valve should be as close to the water supply inlet as possible.
4. An inline water filter is highly recommended. It should be installed after the water
shutoff valve and in a position to facilitate filter replacement.
5. Flush the water supply line and filter before connecting it to the unit.
6. Verify that the water line provides at least 1½ gpm (5.7lpm), and that the water
pressure is between 40-75 psig (276-517kPa).
Electrical Connection
1. Check serial number plate for the maximum wattage and verify that the actual
voltage at the electrical outlet is compatible with the unit’s specifications.
2. Plug unit in. Note that the plug is NEMA 6-30P,is for 30 amp 240 volt supply.
3. The temperature and water tank fill level are pre-set at the factory and there is
no need to turn off the heater during the installation process.
The heating process will start automatically when the tank is filled with enough
water to safely cover the heating element.
WARNING
-Do not plug in this equipment or attempt to operate without all covers in place and all screws fastened.
Installation
Warning: Legs are to be adjusted
only to level the unit. Do not extend
them higher than necessary
!
Back panel of HWD-2110
Power
Switch
Tank
Drain
!
To prevent electrical shock, this
unit must be properly grounded.
Warning:
Tank
Vent
ppliance Inlet
(attach power cord)
Water
Supply
Inlet
3
Final Setup-Fill and Initial Heating
1. Turn on the incoming water supply line and inspect both inside and outside of
the unit for leaks in all fittings and tubes.
2. Plug the unit into the appropriate electrical outlet.
3. Turn on the unit’s main power switch (located on the back).
Screen one-the FETCO Home Screen will display.
4. Within 6 seconds, the water tank will begin filling until tank probe senses water
Screen two, the “FILLING” will display.
5. Water will cover heating element or when tank water is heating from cold,
Screen three-the “HEATING” Screen will display.
The upper and lower “Touch Function Selector” will not light.
6. After the water has reached the lowest of the four set temperatures, the lower
“Touch Function Selector” will light red color to signal that at least one
temperature range is READY
(The touch selector buttons will alternately dim and brighten when selection is not active)
7. The display will read the four temperature settings as the tank temperature
rises. More detailed operation information follows
8. The upper “Touch Function Selector” will light if one or more temperature level
is available during heating
9. Re- inspect for leaks.
Operating Instructions
1. Turn the main power switch on.
2. Touch the upper “Touch Function Selector”, tapping finger to scroll to select
3. When a temperature is enlarged and brightened - that temperature is available.
Touch the lower red selector to dispense hot water.
4. Maximum continuous “ON” is fifteen (15) seconds in a single activating touch
5. Maximum dispense is approximately 22ounces/700cc.
Approximately three full 15 second batches may be dispensed in succession.
6. Unit returns to inactive “Enabled Screen” if no water is dispensed in 3 seconds
7. Steam and condensation from the water tank is released into the vent
whenever the unit is on. Access the vent barbed fitting located on the upper
back to run gravity drain. For venting to a drain, tubing requirement is ¼” I.D.
(To prevent vacuum backflow, do not place discharge end of vent drain tube
into drain sump)
Operator Training
Review the operating procedures with everyone who will be using the unit.
Pay particular attention to the following areas:
1. Selecting and dispensing water at all four levels
2. How to change temperature settings (See page 7)
3. Scrolling and selecting temperatures and operating the hot water faucet.
Pay particular attention to the safety warnings. (See page 6 & 7)
4. Refer to cleaning procedures and drip tray, listed on the following page.
5. Show the location of the on/off switch, water shut off valve and the utility power
supply circuit breaker for the unit. (See page 3)
DISPENSE
ENABLED
SCREEN
Icon appears after
tank fill and
heating. At least
one temperature
is available for
dispensing
Upper Touch
Function Selector
scrolls the menu
selection option
Lower Touch
Function Selector
selects and
activates selected
4
The three primary screens for HWD-2110 start up
Home Screen
when power is
turned on.
(Three screens in
“Standby Mode”Controls inoperative)
Above-Screen One-FETCO Home Screen
Below-Screen Two
Hot Water Tank is
filling.
Upper and lower
Touch Function
Selectors will
disappear, dim, or
brighten while in
standby or while
filling or heating.
(Controls inoperative)
Hot Water Tank is
heating.
Icon appears from
first fill or during
reheating from an
unheated state or
depleted tank.
(Controls inoperative)
Above-Screen Three-HWD Status Screen
-HWD Status Screen