Page 3
Programming Mode
(The main power switch is on the back of the unit.)
Press and hold the STOP button while turning the main power
switch ON.
Release the STOP button when the software version is displayed.
The STOP button is used to advance from one setting to the next.
It is illuminated green when in Programming mode.
The BREW buttons are used to change each setting up or down.
To exit Programming, press and hold the HOT WATER button for
approximately 2 seconds.
The ON/OFF switch may be used to exit programming without saving
new settings.
Example: VER 32.A
Page 4
Batch Settings
Press STOP to continue. Batches are numbered
1 (top switch)
and 2 (bottom switch)
Next, the first batch parameter is displayed – batch 1, brew volume
Use the UP and DOWN buttons to adjust. Display: 1.1 64
Press the STOP button to go to the next parameter – brew time. Display: 1.2 04.00
Repeat the last step until all parameters are programmed for batch #1.
(See the chart below for an explanation of each parameter.)
Next, batch #2 programming begins. Display: 2.0 OFF
Batch 2 may be disabled by leaving it set to “OFF”. Change to “ON” to enable. Batch 1 cannot be disabled.
After both batches are programmed, the temperature settings are next.
Display: 7 200
Page 5
Batch Parameters (X = Batch Number)
Parameter Name Range Default Comment
X.0 Batch Enabled
or Disabled
X.1 Brew Volume
ounces:
X.2 Brew Time
(Min: Sec)
X.3 Bypass Percent Off – 30% Off Percentage of total
X.4 Prewet Percent Off – 25.% Off Percentage of total
X.5 Prewet Delay
(Min:Sec)
X.6 Drip Delay
(Min:Sec)
On/Off On This option is for batch
liters:
32 – 80
0.92 – 2.32 01:30 – 05:00
00:00 – 03:00
01:00 – 03:00
64 oz.
1.9 ltr. 04:00
00:00 The time between
1:30 The time to allow for
2 only. To change from ounces to liters, see Advanced Setting 59.
brew volume.
brew volume.
prewetting and start of brew cycle.
dripping after the brew cycle.
Page 6
Temperature Settings
Parameter Name Range Default Comment
7 Water Temp.
8 Hot Water
Service
9 Brew
Temperature Protection
176°- 204°F
Auto Off On
On / Off On ON= Will brew only at set
201°F
Inside tank. Will be slightly lower at spray head. To display in Celsius, see # 58 in Advanced Settings.
ON Auto= Faucet will
dispense only when not brewing.
On=Faucet always
enabled.
Off=Faucet always
disabled.
temperature.
OFF= Will brew at any
temperature.
Note: Changes will not
take effect until the next brew cycle is complete.
Page 7
10 Enter Advanced
Settings & Diagnostics
Important! After programming, you must press and hold the HOT WATER
button to save the settings and exit programming mode, or changes will be lost.
On / Off Off OFF = Skip Advanced
Settings & Diagnostics. Loop back to start of batch programming. ON = Enter Advanced Settings & Diagnostics. Press STOP to continue.
Page 8
Advanced Settings and Diagnostics
Address Description Range Default Comment
50 Water Resistance
(K)
0 - 200 Displays the electrical
resistance of the water in kilohms as measured between the water level probe and the tank. If greater than 200, or if the tank is not full, the display will read – – – .
51 Water Level
Sensitivity
LO - HI LO
LO – 50 K +/- 5K HI – 130 K +/- 5K If water resistance (address
50) is greater than 25 KΩ, set on HI to prevent unwanted filling of tank.
Page 9
55 Tank
Temperature
XXX°X
Displays current tank
temperature in °F or °C.
57 Reload Defaults 0 - 1 0 Changes all settings to
default factory settings. 0 = Do not reload defaults 1 = Reload all defaults If 1 is selected, you must advance to the next address for this change to take effect.
58 Temperature
Scale
59 Water Volume
Scale
F or C F F = Fahrenheit
C = Celsius
oz or LTR
oz oz = Displays volume in
ounces.
LTR = Displays volume in
liters.
Page 10
60 Brew Valve
Flow Rate
62 Bypass Valve
Flow Rate
17 – 51
If #59 is oz.
0.50 –
1.50
If #59 is LTR.
17 – 51
If #59 is oz.
0.50 –
36
Use this to compensate for
1.05
minor discrepancies in actual volume versus programmed volume. Set lower to increase volume, higher to decrease
44
volume.
1.30
1.50
If #59 is