S A T
www.fagor.com
Nº9882
FILL VALVE
DRAIN PUMP
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
DATE: 11/01/2006
MOTOR DISTIRBUTOR CYCLE
DETERGENTE - RINSE AID
REGENERATION VALVE
C 14
C 15
C 16
C 17
C 18
C 19
C 29
C 30
C 31
C 32
C 33
C 34
C 35
C 36
C 38
C 39
C 40
C 41
C 42
C 43
C 44
C 54 WASH
C 63
C 72
C1 73
C1 74
C1 75
C1 76
C1 77
C1 78
C1 79
C1 80
C1 81
C1 82
C1 83
C1 84
FAGOR INNOVATION 2006 ECO - ALT
AUTOMATIC 55ºC-65ºC
NE
ºC
5
5
ECO
CHECK
+
PROGRAMMES
C
0º
4
S
PRES
EX
MIXED 50ºC
PREWASH
ATE 45ºC
C
DELI
WASH
1
RINSE I
RINSE II
RINSE III
DRY
END OF PROGRAMME
UNNING
R
FAGOR
CE
N
DURA
EN
AUTOMATIC 55ºC-65ºC
RELIABILITY
S DS2 25
S 25 TF 26
CONDITION FOR STEP
TIME
TEMP
65 1020 TI ME_TEMP
55 720 TIME_TEMP
65 480 TIME_TEMP
55 TEMP
65 TEMP
68 TEMP
ACT
25 TF 4
15 TF 20
DS2 21
MNV 22
10 TF 23
20 TF 24
15 TF 27
MNI 28
120 TF
1200 TF
40 TF 48
60 TF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 7 6 5 4 3 2 1 0
USER
C
0º
70ºC
65º
AL
PROGRAMME STEP
1 MNV 1
2 30 TF 2
3 DS2 3
4
5 15 TF 5
6 MNI 6
7 40 480 TIME_TEMP
8 30 TF 8
9 MNV 9
10 30 TF 10
11 25 TF 11
12 15 TF 12
13 MNI 13
14 300 TF
15 180 TF
16 720 TF
17 55 600 TIME_TEMP
18 75 TEMP
19 60 TF
20
21
22
23
24
WASH 1
25
26
27
28
29 60 TF
30 75 TEMP
31 68 720 TIME_TEMP
32
33
34 52 900 TIME_TEMP
35 55 600 TIME_TEMP
36 45 300 TIME_TEMP
37 40 300 TIME_TEMP
38
39 52 1320 TI ME_TEMP R
40 900 TF
41 300 TF
42
43 600 TF
44 180 TF
45 DS2 45
46 MNV 4 6
47 10 TF 47
48
49 20 TF 49
RINSE I
50 DS2 50
51 25 TF 51
52 15 TF 52
53 MNI 53
54 360 TF
55 DS2 55
56 MNV 5 6
57 10 TF 57
58 20 TF 58
RINSE II
59 DS2 59
60 25 TF 60
61 15 TF 61
62 MNI 62
63 360 TF
64 DS2 64
65 MNV 6 5
66 10 TF 66
67 20 TF 67
RINSE III
68 DS2 68
69 25 TF 69
70 15 TF 70
71 MNI 71
72 75 TEMP
73 40 240 TIME_TEMP
74
75
76 55 360 TIME_TEMP
77 45 240 TIME_TEMP
78 240 TF
79 120 TF
80
81
82
83 73 TEMP
84 30 TF
85 DS2 85
86 MNV 8 6
87 20 TF 87
DRY
88 600 TF 88
89 RT 1800 TF 89
90 RT RT RT RT 840 TF 90
91 120 TF 91
92 60 TF 92
END OF PROGRAMME
93 DS2 93
94 MNV 9 4
95 20 TF 95
96 1800 TF 96
97 REIN I O 97
98 STOP Si 98
DOUBLE INTENSIVE 7
PREWASH
HIGYENIZER 75 ºC
INTENSIVE
NORM
RFT RFT RFT RFT RFT RFT
TUR TUR T UR T UR TUR TUR
AS AS AS AS AS AS
AS AS AS AS AS AS
AS AS AS AS AS AS
AS AS AS AS AS AS
SASASASAS
SASASASAS
AS AS AS AS AS AS
AS AS AS AS AS AS
AS | NE+ AS
AL | E+ AL
RE RE RE RE RE RE RE RE RE RE RE RE
RT RT RT RT RT RT
?4:1RE?4:1RE?4:1RE?4:1 RE?4:1RE?4:1RE?4:1RE?4:1RE?4:1 RE?4:1RE?4:1 RE?4:1RE?4:1
RE
4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1
+
NE
+ E+
E
NE
+
HEATING ELEMENT
WASH PUMP
FUNCTIONS
OUTPUTS
MOTOR FAN
??VERSI ON:
OTHERS
PROGRAMME STEP
BASIC FUNCTION
TIME ADJUSTMENT
DRAIN
FILL
7
WASH
DRAIN
FILL
WASH
37
DRAIN
FILL
DRAIN
FILL
WASH
DRAIN
FILL
DRAIN
DRY
DRAIN
END PROGR
Notes on PROGRAMMES:
Temperature mantained at -3ºC
10s/50s
C
Alternate wash
Electronic regeneration
RE
RT Short wash
AS Dirty water
AL Clean water
RFT Water cloudiness
TUR Water cloudiness
4:1 4-in-1 option activated
E+
tion activated
ECO PLUS o
NE+ ECO PLUS option not activated
CHECK
COMPILE
C
Fagor Electrodomesticos, S. Coop. 2004
Programme “Express 40”. Alter loading it only washes with the upper distributor, DS3
Notes on STEP CONDITIONS
DS1, DS2, DS3 and DS4 are the four preset stopping positions for the distributor.
They are all set as the position the distributor reaches 0,1 seconds after a single micro switch contact has opened,
and they are differentiated by the time this contact remains closed.
The nominal contact closing times preceding each stopping position are as follows : :
The motor distributor completes a full turn in 15 seconds
F=50Hz F=60Hz
62 - 0,93 se TDS1 = 0,51 - 0,77 sec
TDS1 =0
00 - 1,35 se TDS2 = 0,83 - 1,12 sec
TDS2 =1
45 - 1,80 se TDS3 = 1,21 - 1,50 sec
TDS3 =1
85 - 2,20 se TDS4 = 1,54 - 1,83 sec
TDS4 =1
Lower
DS2 Open Closed 50s Fill/drain posit.
DS3 Closed Open 50s
DS4 1/2 Open Closed 10s
DS1 Closed 1/2 O
MN full means the level micro switch is indicating full (contact closed)
V (« Monitoring ») : When the MN is full, if this signal is « lost »,
MMN empty means the micro switch level is indicating empty (contact open)
FOR SUPER INTENSIVE, INTENSIVE, AUTOMATIC AND MIXED PROGRAMMES THE CLOUDINESS SENSOR
T BE READ ON PREWASH, TO DECIDE WHETHER TO USE THE SAME WATER
M
FOR WASHING ON AUTOMATIC IT WOULD ALSO WASH AT 55º OR 65º
IF IT DOES NOT HAVE A SENSOR, THE “AS” STEPS ARE PERFORMED
HEATING ELEMENT
The heating element is connected until the step condition temperature setting is reached. It is then switched off.
If the step condition includes another type of condition (e.g. time) apart from a temperature setting:
.- When the temperature setting is reached, the heating element switches off
t when R is indicated, in which case the temperature regulation is done with hysteresis
.- Exce
C
en 10s
the fill valve is activated until the contact closes again
SALT REGENERATION (Regeneration EV)
When Option 4 EN 1 is activated:
.- Subtract 1 from the Regeneration value entered by the User (and store on Power Board-M) ia-M
.- The value entered by the User will appear on the Interface Board (Slave).
:
When this option is activated:
- Skips the RINSE III step
- On WASH 1 phase
.-THE NON-REGENERATION MODELS …skip this step
.-THE REGENERATION MODEL ...performs the step according to the “SALT REGENERATION” note.
Lower Upper
DS2 Open Closed 60s
DS3 Closed Open 120s
DS4 1/2 Open Closed 0s
DS1 Closed 1/2Open 0s
Strictl
eaking, STOP is not a step condition. It means that the step counter is place
Strictl
eaking, RESTART is not a step condition. It means the step counter goes to 0
C1
S A T