EVCO EVC70S40X7XXX03 User Manual

Evco S.p.A. • Code 104C30S40E02 • page 1/6
EVC30S40 / EVC70S40 2 output digital modules for electric bread and pizza ovens version 1.02
E ENGLISH
1 IMPORTANT
1.1 Important
Read these instructions carefully before installation and commissioning and follow all recommendations for installation and for the electric
connection; keep these instructions with the instrument for future consultation.
The instrument must be disposed of according to local Standards regarding electric and electronic appliances.
2.1 Dimensions and installation
Dimensions in mm (in); back-panel installation using M3 studs.
The diagram illustrates the model with the greatest supply of hardware.
2.2 Recommendations for installation
• make sure that the working conditions (temperature of use, humidity, etc.) lie within the limits indicated in the technical data
• do not install the instrument in proximity of heat sources (heaters, hot air pipes etc.) appliances withe strong magnets (large diffusers etc.), places
subject to direct sunlight, rain, humidity, excessive dust, mechanical vibrations or shocks
• in compliance with Safety Standards, the protection against any contact with the electric parts must be ensured via correct installation of the
instrument. All parts that ensure protection must be fixed in a way such that they cannot be removed without the aid of a tool.
3 ELECTRIC CONNECTION
3.1 Electric connection
The diagram illustrates the model with the greatest supply of hardware.
4 MODELS AVAILABLE
4.1 Models available
With reference to the electric connection illustrated in paragraph 3.1.
CODE FUNCTION PROBE 1 PROBE 2 LOAD 1 LOAD 2 NUMBER OF KEYS
EVC30S40J7XXX00 simple regulation chamber probe not used regulation of the not used 0
of the temperature temperature (yes)
EVC30S40J7XXX01 simple regulation chamber probe not used regulation of the auxiliary 4
of the temperature temperature (no)
EVC30S40J7XXX02 top-floor top probe floor probe top floor 4
regulation (no)
of the temperature
EVC30S40J7XXX03 top-floor top probe floor probe top floor 6
regulation (no)
of the temperature
EVC30S40J7XXX04 top-floor top probe floor probe top floor 0
regulation (yes)
of the temperature
EVC30S40J7XXX05 top-floor top probe floor probe top floor 2
regulation (yes)
of the temperature
EVC70S40X7XXX00 cooking timer not used not used acoustics not used 4
EVC70S40X7XXX01 steam injection not used not used timer 1 timer 2 4
EVC70S40X7XXX02 steam injection not used not used timer 1 timer 2 6
EVC70S40X7XXX03 cooking timer not used not used acoustics not used 0
3.2 Recommendations for installation
• do not operate on the terminal boards using electric or pneumatic
screwdrivers
• if the instrument has been taken from a old place to a hot one, the
humidity could condense inside. Wait about one hour before
applying power
• make sure that the power supply voltage, frequency and operational
electric power correspond to those of the local power supply
•disconnect the power supply before performing any type of
maintenance
• equip the probes with a protection able to insulate them against any
contact with metal parts or use isolated probes
• do not use the instrument as a safety device
• for repairs and information regarding the instrument, contact the
Evco sales network.
(ENCODER YES/NO)
(no)
(no)
(no)
(yes)
4.2 Management of the utilities
Temperature regulation.
The output activity depends mainly on the temperature of the
chamber, the work set point and the parameter P5.
Top.
If functioning with 1 measurement input (parameter P3 = 1):
• the out put is measured in a cyclical mode, preferably when the floor
output is off (the parameter P10 establishes the cycle time. Using the
procedure given in paragraph 6.2.1 it is possible to set the duration
of output switch-on, intended as a percentage of the time established
with the parameter P10)
• the cyclical activation is subordinate to the temperature of the
chamber (chamber probe), at the work set point and parameter P4.
If functioning with 2 measurement inputs (parameter P3 = 0):
• the output activity will mainly depend on the temperature of the top
(top probe), the top set point and the parameter P4.
Floor.
If functioning with 1 measurement input (parameter P3 = 1):
• the out put is measured in a cyclical mode, preferably when the top
output is off (the parameter P10 establishes the cycle time. Using the
procedure given in paragraph 6.2.2 it is possible to set the duration
of output switch-on, intended as a percentage of the time established
with the parameter P10)
• the cyclical activation is subordinate to the temperature of the
chamber (chamber probe), at the work set point and parameter P4.
If functioning with 2 measurement inputs (parameter P3 = 0):
• the output activity will mainly depend on the temperature of the
floor (floor probe), the floor set point and the parameter P4.
Timer 1.
The output is on continuously during the count of the time P0.
Timer 2.
The output is on continuously during the count of the time P6.
Acoustics.
The output is on continuously on the conclusion of the count of
the cooking timer.
Auxiliary.
The activity of the output depends mainly on parameters P6 and P7.
5 USER INTERFACE
5.1 Preliminary considerations
The diagram illustrates the model with the greatest supply of hardware.
For all models.
The following functioning states exist:
• the “on” status (the instrument is powered and “on”: the regulators
can be switched on)
• the “stand-by” status (the instrument is powered but is “off” via software:
the regulators are off
• the “off” state (the instrument “is not powered”).
Successively, the term “switch-on” means that the passage from the
stand-by status to the on status; the term “switch-off” means the passage
from the on status to the stand-by status.
When the instrument is powered it re-proposes the status in which it
found itself at the time when the power supply was disconnected.
If there is a power cut during a time count, the count will start again
from the beginning when the power supply is restored.
5.2 Switching the instrument on
For EVC30S40J7XXX01 / 02 / 03 and for EVC70S40X7XXX00 / 01 / 02.
• make sure no procedure is in progress
• press B1 : the L4 LED will switch-off.
For EVC30S40J7XXX00 / 04 / 05 and for EVC70S40X7XXX03.
• make sure no procedure is in progress
• press the encoder button: the L4 LED will switch-off.
5.3 Switching the instrument off
For EVC30S40J7XXX01 / 02 / 03 and for EVC70S40X7XXX00 / 01 / 02.
• make sure no procedure is in progress
• press B1 for 4 s: the L4 LED will switch-on.
For EVC30S40J7XXX00 / 04 / 05 and for EVC70S40X7XXX03.
• make sure no procedure is in progress
• press the encoder button for 4 s: the L4 LED will switch-on.
5.4 The display
For EVC30S40J7XXX00 / 01.
If the instrument is on, the display will show the size established with
parameter P10:
• if P10 = 0, the display will show the work set point
• if P10 = 1, the display will show the chamber temperature
If the instrument is off:
• the display will be off
• the L4 LED will be on
Evco S.p.A. • Code 104C30S40E02 • page 2/6
For EVC30S40J7XXX02 / 03 / 04 / 05.
If the instrument is on, the display will show the size established
with parameter P16:
• if P16 = 0, if functioning with 2 measurement inputs, the display will
show the temperature of the top (otherwise the temperature of the
chamber)
• if P16 = 1, if functioning with 2 measurement inputs, the display will
show the temperature of the floor (otherwise the temperature of the
chamber)
• if P16 = 2, if functioning with 2 measurement inputs, the display will
show the average temperature (otherwise the temperature of the
chamber)
• if P16 = 3, if functioning with 2 measurement inputs, the display will
show the top set point (otherwise the work set point)
• if P16 = 4, if functioning with 2 measurement inputs, the display will
show the floor set point (otherwise the temperature of the chamber)
If the cooking timer count is in progress, the display shows the value,
the L3 LED will flash and the min LED will be on.
If the instrument is off:
• the display will be off
• the L4 LED will be on
For EVC70S40X7XXX00 / 03.
If the instrument is on, the display will show the value of the cooking
timer and the min LED will be on.
If the cooking timer count is in progress, the display shows the value,
the L3 LED will flash and the min LED will be on
If the instrument is off:
• the display will be off
• the L4 LED will be on
For EVC70S40X7XXX01 / 02.
If the instrument is on, the display will show “ - - - “.
If the steam sequence times count is in progress, the display will show
the value, the L1, L2 or L3 LED will flash and if parameter P9 is set at 1
the min LED will be on.
If the instrument is off:
• the display will be off
• the L4 LED will be on
5.5 Silencing the buzzer
For all models.
• make sure no procedure is in progress
• press a key (or turn the encoder): the first press of the key (or rotation
of the encoder) does not cause the associated effect.
6 SETTINGS
6.1.1 Setting the work set point
For EVC30S40J7XXX00.
• make sure that the instrument is in on status and that no procedure
is in progress
• press the encoder button: the display will show the corresponding
value
• turn the encoder within 15 s; see also parameters P2, P3 and P4
• press the encoder button or do not operate for 15 s: the instrument
will leave the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX01.
• make sure that the instrument is in on status and that no procedure
is in progress
• press B1 : the display will show the corresponding value
• press B2 or B5 within 15 s; see also parameters P2, P3 and
P4
• press B1 or do not operate for 15 s: the instrument will leave the
procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX02 (if the parameter P3 is set at 1).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B2 and B5 for 4 s: the display will show the
corresponding value
• press B2 or B5 within 15 s; see also parameters P5, P6 and
P11
• do not operate for 15 s: the instrument will leave the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX03 (if parameter P3 is set at 1).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B2 : the display will show the corresponding value
• press B2 or B5 within 15 s; see also parameters P5, P6 and
P11
• do not operate for 15 s: the instrument will leave the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX04 / 05 (if parameter P3 is set at 1).
• make sure that the instrument is in on status and that no procedure
is in progress
for EVC30S40J7XXX05 # press the encoder button: the display will
show the corresponding value; turn the encoder clockwise within
15 s to show in succession the power supplied at the top and the
one supplied at the floor (after 5 s the display will show the work set
point again)
• press the encoder button during the showing of the work set point:
the display will show the corresponding value
• turn the encoder within 15 s; see also parameters P5, P6 and P11
• press the encoder button three times or do not operate for 15 s: the
instrument will leave the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
6.1.2 Setting the top set point
For EVC30S40J7XXX02 (if the parameter P3 is set at 0).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B2 : the display shows the corresponding value and the
L1 LED will flash
• press B2 or B5 within 15 s; see also parameters P5, P6 and P7
• do not operate for 15 s: the L1 LED will switch-off and the instrument
will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX03 (if parameter P3 is set at 0).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B3 : the display shows the corresponding value and the
L1 LED will flash
• press B2 or B5 within 15 s; see also parameters P5, P6 and P7
• press B3 or do not operate for 15 s: the L1 LED will switch-off and
the instrument will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX04 / 05 (if parameter P3 is set at 0).
• make sure that the instrument is in on status and that no procedure
is in progress
for EVC30S40J7XXX05 # press the encoder button: the display will
show the corresponding value; turn the encoder clockwise within
15 s to show the floor set point (after 5 s the display will show the top
set point again)
• press the encoder button during the showing of the top set point: the
display will show the corresponding value and the L1 LED will flash
• turn the encoder within 15 s; see also parameters P5, P6 and P7
• press the encoder button twice or do not operate for 15 s: the instru-
ment will leave the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
6.1.3 Setting the floor set point
For EVC30S40J7XXX02 (if the parameter P3 is set at 0).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B5 : the display shows the corresponding value and the L2
LED will flash
• press B2 or B5 within 15 s; see also parameters P5, P6 and P8
• do not operate for 15 s: the L2 LED will switch-off and the instrument
will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX03 (if parameter P3 is set at 0).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B4 : the display shows the corresponding value and the L2
LED will flash
• press B2 or B5 within 15 s; see also parameters P5, P6 and
P8
• press B4 or do not operate for 15 s: the L2 LED will switch-off and
the instrument will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX04 / 05 (if parameter P3 is set at 0).
• press the encoder button during the setting of the top set point: the
display will show the corresponding value, the L1 LED switches-off
and the L2 LED will flash
• turn the encoder within 15 s; see also parameters P5, P6 and P8
• press the encoder button or do not operate for 15 s: the L2 LED will
switch-off and the instrument will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
6.2.1 Setting the power supplied at the top
For EVC30S40J7XXX02 (if the parameter P3 is set at 1).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B2 : the display shows the corresponding value and the L1
LED will flash
• press B2 or B5 within 15 s; see also parameters P9, P10
and P12
• do not operate for 15 s: the L1 LED will switch-off and the instrument
will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX03 (if parameter P3 is set at 1).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B3 : the display shows the corresponding value and the L1
LED will flash
• press B2 or B5 within 15 s; see also parameters P9, P10
and P12
• press B3 or do not operate for 15 s: the L1 LED will switch-off and
the instrument will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX04 / 05 (if parameter P3 is set at 1).
• press the encoder button during the setting of the work set point:
the display shows the corresponding value and the L1 LED will
flash
• turn the encoder within 15 s; see also parameters P9, P10 and P12
• press the encoder button twice or do not operate for 15 s: the
instrument will leave the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
6.2.2 Setting the power supplied at the floor
For EVC30S40J7XXX02 (if the parameter P3 is set at 1).
• make sure that the instrument is in on status and that no procedure
is in progress
•press B5 : the display shows the corresponding value and the L2
LED will flash
• press B2 or B5 within 15 s; see also parameters P9, P10
and P13
• do not operate for 15 s: the L2 LED will switch-off and the instrument
will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX03 (if parameter P3 is set at 1).
• make sure that the instrument is in on status and that no procedure
is in progress
• press B4 : the display shows the corresponding value and the
L2 LED will flash
• press B2 or B5 within 15 s; see also parameters P9, P10 and P13
• press B4 or do not operate for 15 s: the L2 LED will switch-off and
the instrument will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
For EVC30S40J7XXX04 / 05 (if parameter P3 is set at 1).
• press the encoder button during the setting of the power supplied
at the top: the display will show the corresponding value, the L1 LED
switches-off and the L2 LED will flash
• turn the encoder within 15 s; see also parameters P9, P10 and P13
• press the encoder button or do not operate for 15 s: the L2 LED will
switch-off and the instrument will exit the procedure.
To exit the procedure in advance:
• do not operate for 15 s (any modifications will be saved).
6.3 Setting the configuration parameters
For EVC30S40J7XXX00 / 04 / 05 and for EVC70S40X7XXX03.
To access the procedure:
• make sure that the instrument is in off status and that no procedure
is in progress
• press the encoder button for 4 s: the central display will show “PA”
• press the encoder button: the display will show the corresponding
value
• turn the encoder within 15 s to set “-19”
• press the encoder button or do not operate for 15 s
• press the encoder button for 4 s: the display will show “P0”.
To select a parameter:
• turn the encoder.
To modify a parameter:
• press the encoder button: the display will show the corresponding
value
• turn the encoder within 15 s
• press the encoder button or do not operate for 15 s
• turn the encoder.
To exit the procedure:
• press the encoder button for 4 sor do not operate for 60 s (any
modifications will be saved).
For EVC30S40J7XXX01 / 02 / 03 and for EVC70S40X7XXX00 / 01 / 02.
To access the procedure:
• make sure that the instrument is in off status and that no procedure
is in progress
• press B2 and B5 for 4 s: the central display will show “PA
• press B1 : the display will show the corresponding value
• press B2 or B5 within 15 s to set “-19
• press B1 or do not operate for 15 s
• press B2 and B5 for 4 s: the display will show “P0”.
To select a parameter:
• press B2 or B5
To modify a parameter:
• press B1: the display will show the corresponding value
• press B2 or do not operate for 15 s
• press B1 or do not operate for 15 s
• press B2 or B5
To exit the procedure:
• press B2 and B5 for 4 s or do not operate for 60 s (any
modifications will be saved).
7 COOKING TIMER (for EVC30S40J7XXX02 / 03 /
04 / 05 and for EVC70S40X7XXX00 / 03)
7.1 Preliminary considerations
For EVC30S40J7XXX02 / 03 / 04 / 05.
The cooking timer allows to start the countdown.
The display shows the value during counting (
for EVC30S40J7XXX05
# the display will show the size established with parameter P24), the
L3 LED will flash and the min LED is on.
Loading...
+ 4 hidden pages