EVCO EVC30S40J7XXX09 User Manual

DEEP FRYER WITH TIMER
AND
DIGITAL INPUTS
REV1.2
1/13
1. USER INTERFACE
FUNCTION KEY FUNCTION B1 START B2 MELT B3 DISPLAY B4 TIMER B5 TIMER
LED FUNCTION L1 START LED L2 MELT LED L3 DISPLAY LED L5 ALARM LED °C Celsius LED °F Fahrenheit LED min TIMER LED
1.1. Setting the set-point
To access the procedure
Press the [ENCODER] button, LED L3 flashes.
To modify the value
Turn the encoder within 15 seconds
To exit the procedure
Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
1.2. Setting the timer
The value of the timer can be set within 0 and 99 minutes. To access the procedure
Make sure the timer is in the stop status.
Press the [B4] key, the min LED flashes, the value on the display flashes.
Alternatively
Press the [B5] key, the min LED flashes, the value on the display flashes.
To modify the value
Turn the encoder within 15 seconds
To exit the procedure
2/13
Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
1.3. Timer start
Press the [B4] key for at least 1 second, the min LED flashes.
Alternatively
Press the [B5] key for at least 1 second, the min LED flashes.
1.4. Timer stop
Press the [B4] key for at least 1 second.
Alternatively
Press the [B5] key for at least 1 second.
1.5. Modifying the count
The count value can be set within 0 and 99 minutes. Setting the count value at 0 means putting the timer in the stop status. To access the procedure
Make sure the timer is in the start status.
Press the [B4] key, the min LED flashes, the value on the display flashes.
Alternatively
Press the [B5] key, the min LED flashes, the value on the display flashes.
To modify the value
Turn the encoder within 15 seconds
To exit the procedure
Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
1.6. Setting the configuration parameters
To access the procedure
Make sure that the instrument is in the STOP status.
Press the [ENCODER] button for 4 seconds, the PA label appears on the display.
Press the [ENCODER] button to display the corresponding value
Turn the encoder within 15 seconds to set the value at -19.
Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
Press the [ENCODER] button for 4 seconds, the first parameter label appears on the
display.
To modify a parameter:
Turn the encoder within 60 seconds to select a parameter.
Press the [ENCODER] button to display the corresponding value
Turn the encoder within 15 seconds to set the desired value.
Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
To exit the procedure
Press the [ENCODER] button for 4 seconds or do not operate on the keyboard for 60 seconds
3/13
1.7. Restoring the default parameters
Press the [ENCODER] button for 4 seconds, the PA label appears on the display.
Press the [ENCODER] button to display the corresponding value
Turn the encoder within 15 seconds to set the value at 743.
Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
Press the [ENCODER] button for 4 seconds, the dEF label appears on the display
Press the [ENCODER] button to display the corresponding value
Turn the encoder within 15 seconds to set the 149 value.
Press the [ENCODER] button or do not operate on the keyboard for 15 seconds. The
display will show the flashing dEF message for 4 seconds.
To exit the procedure
Press the [ENCODER] button for 4 seconds.
1.8. Modification of the magnitude shown on the display
The display can show the value of probe 1, the set-point value or the timer value (setting or count in progress). To modify the magnitude shown on the display
Press the [B3] key for 1 second. LED L3 is on if the data shown on the display is the work set-point. The min LED is on if the data shown on the display is the setting of the timer and the timer is in the stop status.
1.9. Silencing the buzzer
Press a key or the [ENCODER] button. The buzzer rings for
probe 1 error
probe 2 error
temperature alarm
board temperature alarm
the first time the temperature reaches the set-point
at the end of timer count
depending on the status of the digital inputs, further details are seen in the following
paragraphs
1.10. Displaying probe 2 temperature
To access the procedure
Make sure the probe is enabled.
Press the [B3] key, the Pb2 label will appear on the display.
To display the board temperature value
Press the [ENCODER] button.
To exit the procedure
Do not operate on the keyboard for 15 seconds
or
Press the [ENCODER] button to go back to display of the Pb2 label.
Press the [B3] key or do not operate on the keyboard for 15 seconds
4/13