CAUTIONS
This document shall apply only to the product(s) identified herein. No part of this do cu m en t m a y be reproduce d, stored in a re tr ie val system, or tr ans m itted
in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Seiko Epson Corporation.
The contents of this document are subject to change without notice. Please contact us for
the latest information.
While every precaution has been taken in the preparation of this document, Seiko Epson
Corporation assumes no responsibility for errors or omissions.
Neither is any liability assumed for damages resulting from the use of the information
contained herein.
Neither Seiko Epson Corporation nor its affiliate s shall be liable to the pu rch aser of this
product or third parties for damages, losses, costs, or expenses incurred by the purchaser or third parties as a result of: accid ent, misuse, or abuse of this prod uct or unauthorized modifications, repairs, or alterations to this product, or (excluding the U.S.) failure to strictly comply wi th Seiko Epson Corporation's operat ing and maintenance instructions.
Seiko Epson Corpor ation shall not be li a ble against any damages or problems arising
from the use of any options or any consumable products other than those designated as Original EPSON Products or EPSON Approved Products by Seiko Epson Corporation.
TRADEMARKS
EPSON® is a registered trademark of Seiko Epson Corporation. Microsoft Microsoft Corporation.
General Notice: Other product and company names used herein are for identification purposes only and may be trademarks of their respective companies.
®
, MS®, MS-DOS®, Windows
Copyright © 1999 , 2000 by SEIKO EPSON CORPORATION
®,
Windows NT® are registered trademarks of
ii
Page 3
Safety Precautions
This document uses the two headings shown below to call attention to potential hazards. Failure to observe the information provided with these headings may lead to serious or even fatal injury or damage to equipment. Be sure you understand the meaning of each marking before you proceed.
WARNING:
Follow warnings carefully to avoid bodily injury.
CAUTION:
Observe cau tions to avoi d damage to your equipment.
WARNING:
Shut down your equipment immediately if it produces smoke, a strange
odor, or unusual noise. Continued use may lead to fire or electric shock. Immediately turn the power off and contact your dealer or a Seiko Epson
service center for advice. Never disassemble or modify this product. Tampering with this product
may result in injury, fire, or electric shock.
English
Do not allow foreign matter to fall into the equipment. Penetration by
foreign objects may lead to fire or shock. If water or other liquid spills into this equipment, immediately turn the
power off and contact your dealer or a Seiko Epson service center for advice. Continued usage may lead to fire or shock.
iii
Page 4
CAUTION:
Do not use in locations subject to high humidity or dust levels. Exces sive
humidity and dust may cause equipment damage, fire, or electric shock. Do not use the following cards as they may cause damage to the MSR
unit or cause function decline.
A card with a dirty magnetic surface
A card to which an alien substance is attached
A wet card
A chipped or cracked card Do not perform the following actions as they may cause damage to the
MSR unit or cause function decline.
To place heavy objects on top of this product.
Insert an object other than magnetic cards into the MSR unit.
EMC and Safety Standards Applied
Product Name: Magnetic Stripe Reader Type Name: M142B
The following standards are applied only to the units that are so labeled.
Europe: EMC: CE marking
Safety: EN 60950
North America: EMI: FCC/ICES-003 Class A
Safety: UL 1950/ CSA C22.2 No. 950
Japan: EMC: VCCI Class A
JEIDA 52
Oceania: EMC: AS/NZS 3548
WARNING:
The connection of a non-shielded printer interface ca ble to this device wil l invalidate the EMC standards of this device.
You are cautioned that changes or modifications not expressly approved by SEIKO EPSON Corporation could void your authority to operate the equipment.
iv
Page 5
CE Marking
The unit conforms to the following Directives and Norms:
Directive 89/336/EEC
EN 55022 Class A EN 55024
IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11
WARNING:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
FCC CLASS A
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant t o Par t 15 of the FCC Rul es . Thes e limit s are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates , uses, and c an radiate rad io frequenc y energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
English
For Canadian Users
This Class A digital app aratus complies with Canadian ICES-003.
For Taiwanese Users
v
Page 6
Contents
Contents
ContentsContents
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
EMC and Safety Standards Applied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
FCC CLASS A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Connecting the MSR Unit to the IR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Precautions When Using (for IM-300) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
How to Update Keyboard Firmware (for IM-300 only) . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Utilities (for IM-300 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Procedure (for IM-300 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Update File for Keyboard Firmware Update (INSTKBF.BAT) . . . . . . . . . . . . . . . . 5
Windows Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
MS-DOS Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Keyboard Firmware Setting Utility for Windows
(for IM-300 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Keyboard Firmware Setting Utility for MS-DOS
(for IM-300 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
How to Read a Magnetic Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Beep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
vi
Page 7
Overview
The DM-MR123 is an optional magnetic stripe reader (MSR) unit for the IR Series. Data read by the MSR unit is transferred via the IR Series keyboard interface.
The DM-MR123 can read the following magnetic stripe cards (hereafter referred to as magnetic cards):
ISO 7811, JIS X6301 type I, track 1, 2, and 3
An LED on the DM-MR123 and a buzzer indicate whether the unit has read the data correctly or not.
The update of the keyboard firmware and the installation of the attached utilities are required to use the MSR unit.
Unpacking
Please confirm that the package contains these items:
MSR Unit
Setup Utility Diskette
Screws (2)
User’s Manual
Connecting the MSR Unit to the IR Series
To connect the MSR unit to the IR Series(DM-LR104/DM­LR104SV/DM-LR121SV/DM-KR084), follow the next steps:
1. Confirm that the IR Series is turned off.
English
CAUTION:
Turn off the power of the IR Series before attaching or removing the MSR unit, or the unit may be damaged.
1
Page 8
2. Remove the connector cover af the right side of the LCD unit.
Connector cover
3. Connect the MSR unit to the MSR interface.
4. Fix the MSR unit the screws attached to this produ ct.
CAUTION:
Do not tighten the screws too tightly, or the unit may be damaged. (The maximum torque is 1
N•m (10KG f•m)).
To connect the MSR unit to the 28 keyboard unit (DM-KR028), please refer to the “DM-KR028 User’s manual” “
Developer’s Guide.
or IR Series
Precautions When Using (for IM-300)
Pay attention to the following points when you use this product:
Before you use the DM-MR123, be sure to update the keyboard firmware by executing the upda te file (INSTKBF.BAT) which is included in the package.
Pay attention to the following points when you use the DM-MR123 under the configuration of the DM-MR111:
2
Page 9
1. EPSON OPOS ADK Settings When you use this product with the EPSON OPOS ADK, select “DM-MR123” at the model selection. If “ DM-MR123” is not on the list, select “DM-MR111-012” (for track 1 and 2) or “DM-MR111-013” (for track 2 and 3.)
2. Using the DM-MR123 as the former DM-MR111 When you use this product as the former DM-MR111 (DM­MR111-012 or DM-MR 111-013), spec ify read tracks by using the Keyboard Firmware Setting Utility or the following PKMODE command: To use as the DM-MR111-012: To use as the DM-MR111-013:
To disable the buzzer which beeps when the DM-MR123 reads a card, use the Keyboard Firmware Setting Utility or the following PKMODE command: To disable the buzzer: To enable the buzzer:
PKMODE BEEP=OFF
PKMODE BEEP=ON
PKMODE MSR1 PKMODE MSR3
How to Update Keyboard Firmware (for IM-300 only)
Note:
Please do not execute on the IM-310.
English
If you are using the old version of keyboa rd firmwar e (version 2.00 or below), you cannot use the DM-MR123. You must update the keyboard firmware.
The DM-MR123 package provides a update file (INSTKBF.BAT) that checks the version of the keyboard firmware and updates the old version to the newer version. Run this update file before using the DM-MR123. Once it has been run, it is not necessary to run it again. The INSTKBF.BAT update file also is supplied with the 28­key keyboard unit (DM-KR028), but even if you have updated the keyboard firmware with that file, you have to run this update file attached to this product again.
When the keyboard firmware is updated using the attached update file, the key definition data for the DM-KR028/DM-KR084/DM­MR111 and the keylock definition data will be copied and restored automatically and you do not have to worry about losing th em.
3
Page 10
However, syste m variables wil l return to the in itial values ot her than the follo wing:
MSR decode setting flag Trace mode setting (TRON/TROFF) Country setting (US/JP)
Follow the steps below to update the keyboard firmware.
1. Duplicate the Setup Utility diskette attached to ths product. Use the DISKCOPY command or Explorer to make copy. Hereafter, use the duplicate diskette.
2. Turn on the IM-300 in the MS-DOS mode. If your IR Series is Windows 95/98 model (hereafter referred to as 9X model), exit Windows and restart the system in the DOS mode. If Windows NT is installed, restart using a DOS disket te.
Note:
Updating the keyboard firmware cannot be performed from the MS­DOS prompt of the Windows.
3. Insert the duplicate Setup Utility diskette into the floppy disk drive.
Note:
Be sure to remove the write protection from the diskette because key definition data and system variables will be written to the diskette during the keyboard firmware update.
4. Change the current directory to the floppy disk drive by typing the following and pressing
A:
5. Run INSTKBF.BAT on the duplicate Setup Util ity diskette by typing the following and pressing
INSTKBF
Wait a few minutes for the upgrade to finish.
6. Remove the duplicate Setup Utility diskette and reset the IM-300.
Enter:
Enter
:
4
Page 11
CAUTION:
Do not turn off or reset the IR Series during updating the keyboard firmware. This may cause damage to your system.
Utilities (for IM-300 only)
Note:
If your system does not use a pre-installed OS, please obtain the utility from
your vendor. Please use the tool pre-installed to your HDD for the IM-300 utility.
Please refer to the IM-310 Developer's Guide for information on IM-310
software.
The following utilities are stored on the Setup Utility diskette.
Update file for Keyboard Firmware (INSTKBF.BAT)
This update file checks the version of the keyboard firmware and updates it if the keyboard firmware is the old one. This update file must be run before using the DM-MR123. Once it is run, it is not necessary to execute it again.
Keyboard Firmware Utility
This utility sets the keyboard firmware settings for the IR Series. It is also used to set the settings for the MSR unit. There are two types: one is for the MS-DOS (PKMODE.EXE) and the other is for the Windows 9X/NT (PKMODE32.EXE).
English
Installation Procedure (for IM-300 only)
Note:
Please do not execute on the IM-310.
Follow the steps below to install software onto the hard disk.
Update File for Keyboard Firmware Update (INSTKBF.BAT)
You do not need to install this program before running it. Run INSTKBF.BAT directly from the Setup Utility diskette. Please refer to “How to Update Keyboard Firmware” for details.
5
Page 12
Windows Utilities
To install the Windows utilities, run the installation program (SETUP.EXE). The installation program is stored in the \9XNT directory on the Setup Utility diskette.
Install the Windows utilities as follows:
1. When you already installed the Windows utility attached to the 28 keyboard unit (DM-KR028) or the OS, delete “28 Key Configura tion Utilitie s” by using “Add/Remove Programs” command in the control panel.
2. Insert the duplicate Setup Utility diskette into the IM-300 floppy disk drive.
3. Run A:\9XNT\SETUP.EXE from Windows Explorer.
4. Follow the messages on the screen to install utilities.
5. Following utilities will be installed und er [Start] - [Program] ­[Key Configuration Utilities].
Configure 28 Keyboard: 28-Keyboard definition util ity Configure Firmware and MSR: Keyboard firmware setting utility
Note:
When you run this installation, not only the M SR utility but also the 28-key keyboard definition utility are installed. Use the 28-key keyboard definition utility only when the 28-key keyboard (DM-KR028) is attached. Please refer to the “DM-KR028 User’s Manual” for more detailed information.
MS-DOS Utilities
Note:
Please do not execute on the IM-310.
Run the installation program INSTALL.BAT to install or update the MS-DOS utilities. This program is stored in the \DOS directory on the Setup Utility diskette.
6
Page 13
To install the MS-DOS utilities follow the steps below:
1. Start the IM-300 with MS-DOS.
2. Insert the duplicate Setup Utility diskette int o the I M-3 00 f lopp y disk drive.
3. Run INSTALL. BAT by typing the command in following format at the DOS prompt.
A:\DOS\INSTALL
A directory named “C:\POSKB” will be created automatically and
the following files will be copied.
Specify the full path of the directory name to use to copy the
MS-DOS utilities. If the specified directory does not exist, that directory will be created.
The following files will be copied by INSTALL.BAT:
PKMODE.EXE: Keyboard firmware setting utility POSKB28.EXE: 28-keyboard defi nit io n util it y KEYTABLE.DEF: Scan code conversion table K28_DL.CFG: Configuration file for 28-keyboard
definition
Note:
If you want to specify a directory which files will be copied into, use the following command:
A:\DOS\INSTAL L Di rectory Name
Specify the full path of the directory name to copy the MS-DOS files. If the specified directory does not exist, that directory will be created.
If you specify more than two levels of subdirectories that do not exist when you specify a directory, the directory will not be made properly.
English
7
Page 14
Keyboard Firmware Setting Utility for Windows (for IM-300 only)
Note:
Do not use on the IM-310.
Please refer to PKMOPE2.EXE, which is pre-installed to the HDD for the
IM-310.
The Keyboard Firmware Setting Utility for Windows 9X/NT changes the keyboard firmware settings and also is used to change the MSR settings.
Start
The Keyboard Firmware Setting Utility for Windows 9X/NT (PKMODE32.EX E) is copied in th e specified direct ory during installation. When you have not specified a directory, the utility is copied in the C:\Program Files\Key Config directory.
You can start the Keyboard Firmware Utility in either of the following ways.
Double click PKMODE32.EXE from the Windows Explorer.
Click
Key Configurati on Utility
and MSR
from the Program menu.
When the program starts, the following screen appears.
Configure Firmware
8
Checkbox
Page 15
Settings
The details for each item on the screen are as follows:
Ignore Keyboard/MSR Command
When this checkbox is checked, subsequent commands for the keyboard firmware are not accepted. This function is used when an external programmable keyboard is being programmed.
The default setting is OFF.
Note:
When this checkbox is checked, you cannot run this ut ilit y in ordinary way. To uncheck this checkbox, remove the ext ernal ke yboard and execute this program, or use the MS-DOS utility PKMODE.EXE.
MSR Track Recognition (ISO Track1/Track2/Track3)
Check the checkbox for the track to be read. Multiple selections are possible.
The default set ting is Track1, 2, and 3.
Note:
As the DM-MR123 does not support the JIS2 track, do not select JIS2.
English
MSR Code Type (106 Key Based Sca n Code (JA)/101 Key Based Scan Code (EN))
Select the setting that matches the language version of Windows in use. Select language, and Japanese language.
The default s etting is
MSR Start/End Sentinel (Card Start/Card End/•••)
Set the character to be added at the front and end of data during loading. It is possible to specify this setting for each card and each track. Leave this field blank if no character is to be added.
101 Key Based Scan Code (EN)
106 Key Based Scan Code (JP)
101 Key Based Scan Code (EN).
to set the English
to set the
9
Page 16
The default settings are as follows:
Card Start "" (None) Card End "" (None) Track 1 Start: "%" Track 1 End: "?" Track 2 Start: ";" Track 2 End: "?" Track 3 Start: "+" Track 3 End: "?"
You can use the following special charac ters.
Carriage return: "\R" or "\r" Tab: "\T" or "\t" "\": "\\" Others: "\xx"
Specified directly with xx as two­character hexadecimal character codes. Do not specify from 00h to 1Fh as these codes are assigned to the function keys and the like.
Note:
When you use the EPSON OPOS ADK, never c hange the default settings.
Use MSR Beep
Turns the buzzer on and off. Check the checkbox to enable the buzzer when the DM-MR123 reads a card. When the DM-MR123 succeeds in reading a card, the buzzer beeps once. When a read error occurs, the buzzer beeps three times. When this checkbox is unchecked, the buzzer does not beep even if the DM-MR123 reads a card.
10
Default setting is on.
Information
Displays the version number of this utility.
Page 17
Exit
There are two ways to exit this utility:
Click the OK button Clicking the OK button enables the
current sett ings and exits the utility.
Click the
Cancel
button Clicking the
the current s ettings and ex its the utility.
Cancel
button cancels
Keyboard Firmware Setting Utility for MS-DOS (for IM-300 only)
The Keyboard Firmware Setting Utility for MS-DOS changes the keyboard firmware settings. This utility is also used to change the MSR settings.
Start
During the installation procedure, the program copies the Keyboard Firmware Settin g Utility for MS-DOS (PKMODE.EXE) into the specified directory. Wh en no directory is specified, the utility is copied into th e C:\POSKB di rectory.
Start this program as follows:
1. Start the IM-300 with the MS-DOS.
2. Change to the direct ory which the utility is copied into.
English
3. Type the command
Note:
This utility cannot be run in a DOS prompt or a DOS box of the Windows.
PKMODE
at the keyboard; then the utility starts.
11
Page 18
Format
PKMODE.EXE [MSR1|MSR3|MSR] [US|JP] [CMDOFF|CMDON]
[TK0SS=string][TK0ES=string][TK1SS=string] [TK1ES=string][TK2SS=string][TK2ES=string] [TK3SS=string][TK3ES=string][TKJSS=string] [TKJES=string][BEEP=ON|BEEP=OFF][MSR=nn]
TK0SS=string: Changes the start flag of whole magnetic card to the
string specified by “string.” Default is ““ (none).
TK0ES=string: Changes the end flag of whole magnetic card to the
string specified by “string.” Default is ““ (none).
TKJSS=string: Changes the start flag of the MSR JIS2 type (for
Japanese market only) to the string specified by “string.” Default is “ “ (20h).
TKJES=string: Changes the end flag of the MSR JIS2 type to the
string specified by “string.” Default is “ “ (7Eh.)
BEEP=ON: Enables the buzzer to beep when the DM-MR123
reads a magnetic card. The buzzer beeps once when the DM-MR123 reads a magnetic ca rd correctl y . The buzzer beeps three times successively when the DM­MR123 fails to read a magnetic card. The L E D a lso blinks. Default setting.
BEEP=OFF: Disables the buzzer from beeping when the DM-
MR123 reads a magnetic card. Only the LED blinks.
MSR=nn: Specifies effective tracks when the DM-MR123 tries
to read a magnetic card. Available characters are “1,” “2,” and “3.” Each represents Track 1, track 2 and Track 3 respectively D efault is “1 23.” “MS R1” is the same as “MSR=12.” “MSR2” is the same as “MSR=23.”
Note:
As the DM-MR123 does not support the JIS2 track, do not specify JIS2.
Refer to "POS Key Mode Setting Utility" in the IM-300 User’s Manual for details on other parameters.
12
Page 19
How to Read a Magnetic Card
When the IR Series is turned on, the DM-MR123 beeps briefly, and lights the LED green to show that the system is booting up correctly. Then the light turns off, and the MSR becomes ready to read. To read a magnetic card, hold the card as shown below, positioning the magnetic card following the arrow on the magnetic card, and pass it through the MSR unit.
When the MSR unit reads the card successfully, the LED on the MSR unit lights green and the beeps once. When the MSR unit fails to read, the LED on the MSR unit lights orange and the buzzer beeps three times.
Note:
Be sure to insert the magnetic card in the right direction.
Do not use the keyboard while the MSR unit is reading a card. And do not use the MSR unit while you are operating the keyboard. It may cause a read error.
Use magnetic cards confomring to the ISO standard.
When you want to set a starg flag or end flag to a magnetic card, use the utility attached t o this product.
Use the magnetic card whose coercive force is 23700 A/m.
English
LED
The LED indicator on the DM-MR123 has the following meanings
LED Status
OFF Ready to read. Green The system boots up correctly or
Data read has been carried out successfully.
Orange A data read error has occurred.
:
13
Page 20
Beep
The beep of the DM-MR123 has the following meanings. The Beep settings can be performed with the Keyboard firmware setting utility.
Beep Status Beep OFF Beep ON
Short beep once The system boots up correctly. Yes Yes Short beep once Da ta read has be en carried
Short beep three times
out successfully. A data read error has
occurred.
No Yes
No Yes
Specifications
Summary
Usable magne tic cards: ISO7811, JIS X6301 type I
track 1, 2, and 3 External interface: For the MSR unit Supporting keyboard firmware: Version 2.10 or later
Dimensions and Weight
Dimensions (W) × (D) × (H): 57.6 mm × 114 mm × 77.6 mm
(2.27 × 4.49 × 3.05”) Weight: Approximately 200 g (7.05 oz)
Environmental Specifications
Temperature (Operating): 5° to 35°C (41° to 95 °F) Temperature (Storage): –10° to 50°C (14° to 122 °F)
Humidity (Operating): 30 to 80%RH (No condensation) Humidity (Storage): 30 to 90%RH (No condensation)
Reliability
Magnetic head life: 300,000 card swipes