Emerson Liebert XD CoolFrame User Manual

Pr
ecision Cooling
f
or Business-Critical Continuity
Liebert XD™CoolFrame
Fully Integrated Cooling Solution For The Egenera®BladeFrame®EX System
Working Together To Meet The Challenges Of Today’s Data Centers
Egenera and Liebert have recognized that many customers are concerned with rising heat loads in their
acilities and wanted to provide a flexible, cost-effective
f solution to reduce the stress on existing cooling systems as additional computing capacity is installed.
The Liebert XD CoolFrame allows the BladeFrame EX to be placed in a data center environment around other heat-generating equipment without adding to the heat load in the room. Use of the Liebert XD CoolFrame also enables users to place more BladeFrame EX systems into the data center than would otherwise be possible without it.
Liebert XD CoolFrame
Liebert XD Pumping Unit
A Cooling Solution For Your Egenera BladeFrameEX System From The Leader In High Density Heat Removal
The Liebert XD Solution
iebert XD Waterless Coolant—This unique application of an off-the-
Liebert XD Cooling Solutions: An Adaptive Mission-Critical Cooling Architecture That Accommodates Changes
L
shelf product makes the Liebert XD solution very energy efficient. The XD Coolant operates at low pressure and becomes a gas at room temperatures, making it ideal for use around electronic equipment.
Tighter spacing of racks and higher component density within each rack can require a level of cooling that is much greater than traditional computer room air conditioning systems can effectively handle. The number of cooling units needed and the energy required to operate them make this arrangement extremely inefficient. The Liebert XD CoolFrame allows a higher density of BladeFrame EX systems within the data center than is possible with standard computer room cooling solutions.
Adding targeted supplemental cooling is much more cost­efficient than trying to lower the temperature of localized hot spots by increasing the overall room air conditioning capacity. Liebert X-treme Density mission-critical cooling systems are specifically designed to address the higher heat loads generated by tightly packed electronic rack enclosures. Individual systems can cool hot air ejected from the enclosure or cool hot spots or zones near the racks.
There are two reasons the Liebert XD system uses a waterless refrigerant. First, many data center managers are reluctant to re-introduce water into their facilities because of the possibility of equipment damage from leakage. Secondly, the refrigerant used in the Liebert XD system is more efficient than water and has advantages in system design and reducing energy costs associated with cooling.
Liebert XDC—A Coolant Chiller
Designed For Direct System Configurations
The Liebert XDC Coolant Chiller is a specially designed indoor unit that connects directly to the Liebert XD CoolFrame modules and provides XD Coolant circulation and control. It ensures that the coolant is constantly above the dew point in the room, eliminating concern for condensation. Available with several heat rejection options.
H2O H2O
Liebert XDC
Chiller
Liebert XDP— Pumping Unit
Designed For Indirect System Configurations
When a building chilled water system is available, the Liebert XDP Pumping Unit serves as an intermediary to isolate the building chilled water circuit from the XD Coolant circuit. It circulates coolant to the Liebert XD CoolFrame at a temperature always above the dew point to prevent condensation.
Liebert XDP
Pumping Unit
An Innovative Cooling Solution For An Innovative Computing System
Liebert XD CoolFrame modules attach directly to the rear of the Egenera BladeFrame EX system. Heat removal is provided by either the Liebert XDC Coolant Chiller or a Liebert XDP Pumping Unit used in conjunction with an existing chilled water circuit.
Use of the Liebert XD CoolFrame solution with the BladeFrame EX system can promote efficient expansion of data center capacity with a minimal impact on your data center infrastructure. This provides data center managers with the potential to increase processing capacity while maintaining maximum usage of floor space.
Liebert XD CoolFrame retains same depth and footprint as
adeFrame EX.
l
B
Liebert XD™ CoolFrame
Features Include:
Reliability:
Maintains all BladeFrame functionality
renowned serviceability features are unaffected. Efficient cable management is preserved.
Liebert quality — Your assurance of reliability and worldwide support.
Flexibility:
Easy to install — Simple mechanical attachment to the BladeFrame EX.
Liebert XD System Compatibility
— Fully compatible with Liebert XDP and XDC units.
Everything you need — No additional air movers are required for the BladeFrame EX system. No additional power is required for Liebert XD CoolFrame.
w total cost of ownership:
o
L
Saves on cooling costs — Saves 23% o
f typical data center cooling
energy cost.
Takes up no additional floor space
— BladeFrame EX retains same footprint, even with the Liebert XD CoolFrame modules attached.
— BladeFrame EX
We Can Take The Heat…Away
For more information on how the Liebert XD CoolFrame solution can
and the cooling options available for your Egenera BladeFrame EX
exp
em, talk to your local Liebert Representative. We have the product
t
s
y
s technology, application expertise and service support to keep your systems operating flawlessly around the clock.
Specifications
ompatibility
C
oduct Model Number
Pr
Egenera BladeFrame EX BC 100101, BC 100102
ebert XD CoolFrame Module XD-CF-10-XX
Li Liebert XDP XDP160RXXXX
ebert XDC XDC160AXXXX
Li Liebert XD Field Piping Kits and Liebert XD Connection Port Kits
Technical Data
Liebert XD CoolFrame Module
ominal Capacity 10 kW (2.8 tons)
N
eight 30-1/4" (768mm)
H
idth 12-1/4" (311mm)
W Depth 6-1/2" (165mm)
eight, empty 18 lbs (8kg)
W
lex-Pipe Length Top Module 6' (1.8m)
F
Liebert XD
Nominal Capacity 160 kW (46 Ton), 60Hz
Height x Width x Depth 76"x37"x30" (1930mm x 940mm x 762mm) Minimum Number of Liebert 4
XD CoolFrame modules
Liebert XDC
Nominal Capacity 160 kW (46 Ton), 60Hz
Height x Widt h x Depth 78"x74"x34" (1981mm x 1879mm x 863mm) Minimum Number of Liebert 7
XD CoolFrame modules
P
Bottom Module 10' (3m)
140 kW (40 Ton), 50Hz
130 kW (37 Ton), 50Hz
DIRECT SYSTEM CONFIGURATION
Liebert Corporation
earborn Drive
1050 D
.O. Box 29186
P
olumbus, Ohio 43229
C 800 877 9222 P
anada Only)
C 614 888 0246 P 614 841 6022 FAX
ia Leonardo Da Vinci 8
V
ona Industriale Tognana
Z 35028 P
aly
It 39 049 9719 111 P 39 049 5841 257 F
rson Network Power Asia Pacific
Eme
., Dah Sing Financial Centre
7/F 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 P 852 28029250 FAX
hone (U.S. &
hone (Outside U.S.)
iove Di Sacco (PD)
hone
AX
hone
liebert.com
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.)
le every precaution has been taken to ensure accuracy
Whi and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting
rom use of this information or for any errors or omissions.
f
ation. All rights reserved throughout
por
or
t C
r
be
e
© 2006 Li the world. Specifications subject to change without notice.
ferred to are trademarks or registered
e
s r
ame
All n trademarks of their respective owners.
bert and the Liebert logo are registered trademarks
e
® Li of the Liebert Corporation.
SL-16675 (2/06) Printed in USA
t
r
be
ie
n
L
lant
oo
XDC C
Chiller
Liebert
XDC Coolant
Chiller
XD Coolant
an
l
oo
XD C
Liebert XD CoolFrame
ame
r
lF
oo
t XD C
r
be
ie
L
t
Liebert XD CoolFrame
Liebert XD CoolFrame
Liebert
Heat jec
e
R
o
ti
INDIRECT SYSTEM CONFIGURATION
Building
ed
ll
hi
C Water
Egenera, Egenera stylized logos, BladeFrame and CoolFrame are trademarks or registered trademarks of Egenera, Inc. in the United States and other countries.
Contact Egenera at 508-858-3600
Liebert
XDP
be
ie
L
XDP
XD Coolant
t
r
Liebert XD CoolFrame
bert XD CoolFrame
ie
L
Liebert XD CoolFrame
Emerson Network Power.
The global leader in enabling
siness-critical continuity.
u
b
AC Power Systems
y
vit
ti
onnec
C DC Power Systems Embedded Power Power Protection Integrated Cabinet Solutions Outside Plant
ecision Cooling
Pr
onitoring and Services
e M
Sit
Emerson Network Power and the Emerson Network Power logo are trademarks and
rvice marks of Emerson Electric Co.
e
s ©2006 Emerson Electric Co.
Loading...