Emerson Liebert XD CoolFrame User Manual

Pr
ecision Cooling
f
or Business-Critical Continuity
Liebert XD™CoolFrame
Fully Integrated Cooling Solution For The Egenera®BladeFrame®EX System
Working Together To Meet The Challenges Of Today’s Data Centers
Egenera and Liebert have recognized that many customers are concerned with rising heat loads in their
acilities and wanted to provide a flexible, cost-effective
f solution to reduce the stress on existing cooling systems as additional computing capacity is installed.
The Liebert XD CoolFrame allows the BladeFrame EX to be placed in a data center environment around other heat-generating equipment without adding to the heat load in the room. Use of the Liebert XD CoolFrame also enables users to place more BladeFrame EX systems into the data center than would otherwise be possible without it.
Liebert XD CoolFrame
Liebert XD Pumping Unit
A Cooling Solution For Your Egenera BladeFrameEX System From The Leader In High Density Heat Removal
The Liebert XD Solution
iebert XD Waterless Coolant—This unique application of an off-the-
Liebert XD Cooling Solutions: An Adaptive Mission-Critical Cooling Architecture That Accommodates Changes
L
shelf product makes the Liebert XD solution very energy efficient. The XD Coolant operates at low pressure and becomes a gas at room temperatures, making it ideal for use around electronic equipment.
Tighter spacing of racks and higher component density within each rack can require a level of cooling that is much greater than traditional computer room air conditioning systems can effectively handle. The number of cooling units needed and the energy required to operate them make this arrangement extremely inefficient. The Liebert XD CoolFrame allows a higher density of BladeFrame EX systems within the data center than is possible with standard computer room cooling solutions.
Adding targeted supplemental cooling is much more cost­efficient than trying to lower the temperature of localized hot spots by increasing the overall room air conditioning capacity. Liebert X-treme Density mission-critical cooling systems are specifically designed to address the higher heat loads generated by tightly packed electronic rack enclosures. Individual systems can cool hot air ejected from the enclosure or cool hot spots or zones near the racks.
There are two reasons the Liebert XD system uses a waterless refrigerant. First, many data center managers are reluctant to re-introduce water into their facilities because of the possibility of equipment damage from leakage. Secondly, the refrigerant used in the Liebert XD system is more efficient than water and has advantages in system design and reducing energy costs associated with cooling.
Liebert XDC—A Coolant Chiller
Designed For Direct System Configurations
The Liebert XDC Coolant Chiller is a specially designed indoor unit that connects directly to the Liebert XD CoolFrame modules and provides XD Coolant circulation and control. It ensures that the coolant is constantly above the dew point in the room, eliminating concern for condensation. Available with several heat rejection options.
H2O H2O
Liebert XDC
Chiller
Liebert XDP— Pumping Unit
Designed For Indirect System Configurations
When a building chilled water system is available, the Liebert XDP Pumping Unit serves as an intermediary to isolate the building chilled water circuit from the XD Coolant circuit. It circulates coolant to the Liebert XD CoolFrame at a temperature always above the dew point to prevent condensation.
Liebert XDP
Pumping Unit