Reduce Cooling Costs by up to 50% Without Compromising Reliability
Precision Cooling for
Business-Critical Continuity
TM
Lower Cooling Energy Consumption by up to 50%
Fluid- and Air-side economizers take advantage of cold outside
temperatures to provide “free cooling” cycles that reduce or
eliminate the operation of data center precision cooling system
compressors and pumps.
Using economizers, you can lower cooling energy usage by up
to 50% − depending on the average ambient temperature and
humidity of your site.
A Focus on Energy Efficiency
While many IT professionals are considering economizers in
preparation for potential code or legislation changes, a move
toward improved efciencies can pay off with rewards of its own −
especially in terms of lower operating costs and utility incentives.
For example, some utility companies offer rebates for using energyefcient equipment, quickly increasing your return on investment
and overall savings.
Geographic regions of greatest cooling economization opportunity
Consider Chiller Plant Economizer
Consider Chiller Plant or GLYCOOL Cooling Economizer
Consider Chiller Plant or Air Economizer
Consider Chiller Plant, Air Economizer or GLYCOOL Cooling Economizer
Industry Best Practices
When making the choice to use an economizer solution, it is critical
to analyze how changes will impact your entire data center.
®
Industry thought leader ASHRAE
recommends that IT professionals
investigating the use of economizers in their data centers
consider the impact of incorrect application, and/or maintenance/
operational issues, on the life of protected sensitive equipment:
■
High humidity can cause condensation that reduces server life and
affects operation
■
Low dew point can result in problems such as static electricity
■
Gaseous or particulate contaminants can adversely affect sensitive
electronics
■
Operational reliability, including redundancy, is required to
achieve IT initiatives
■
Reliable water sources for cooling towers
■
Chiller condensate sump heaters for cold climate operation (or
other solutions)
Why Emerson Network Power?
For more than 40 years, Liebert technologies have led the industry
in precision cooling for data centers, including economizing
solutions such as the free-cooling GLYCOOL system.
Our depth and breadth of experience make us uniquely prepared to
serve as trusted advisors to IT professionals. Liebert representatives
can help you decide which economization method is the right
solution for your application. They will guide you through the
complexities of environmental factors affecting your decision
making, including temperature ranges, dew point, humidity,
and the issue of gaseous and particulate contaminants, as well as
maintenance issues that impact all types of econimizers.
It’s how we deliver Efciency Without Compromise™ − providing
high availability products with energy-efcient technologies.
Efciency Without Compromise
Efciency Without Compromise provides a path to optimize data center infrastructure around design, operating and management
efciencies – while maintaining or improving availability. This is achieved through the proper selection and utilization of cooling, power and
monitoring technologies, supported by key services and local expertise.
INFRASTRUCTURE
MANAGEMENT
Impro ving perfo rmance
of the IT i nfrastru cture
and environment
ECO AVAILABILITY
Balan cing high leve ls
of availability and
efciency
2
FLEX CA PACITY
Adapti ng to IT change s
for continuous
optimization and
design exibility
HIGH DENS ITY
Delivering architectures
from 10- 60kW/rack to
minimi ze space and cos t
AtlantaChicagoSeattle
Fluid EconomizerLiebert
Cooling
Tower
Dry-
cooler
CW or DS
with Air
Economizer
Full Economizer Hours25%17%18%48%41%14%39%23%27%
Partial Economizer Hours52%34%33%39%28%22%61%61%15%
Estimated Total Energy Savings51%36%34%67%58%25%70%49%34%
The effect of ambient conditions in representative cities on economization hours and resultant energy savings, using different
economization methods (assumes cold aisle temperature 71°–80° F; CRAC return temperature 85° F). Cooling tower calculations were
made with Liebert chilled water-based precision cooling products. Drycooler calculations were based on Liebert precision cooling products
equipped with GLYCOOL option. Air economizer calculations based on 41.9° F dew point limitation.
Fluid EconomizerLiebert
Cooling
Tower
Dry-
cooler
CW or DS
with Air
Economizer
Fluid EconomizerLiebert
Cooling
Tower
Dry-
cooler
CW or DS
with Air
Economizer
Liebert Precision Cooling Economization
In accordance with ASHRAE’s guidance, and in keeping with our position as the industry’s power and cooling leader, Emerson Network
Power provides effective, efcient economizer solutions. Emerson Network Power offers uid-side economization solutions and an air-side
economizer – and Liebert technologies are well suited to work with economization solutions from third-party providers.
No economizer
Full economizer
Partial economizer
■
Potential dependant on dew point
Comparative hours of economizer operations through varying CR AC supply and return temperatures in three cities representing distinct ambient conditions
(partial economizer operation = outside ambient used to precool or assist in cooling of data center return air).
Fluid-Side vs. Air-Side Economization Comparison
Fluid-SideAir-Side
Advantages
■
Can be used in any climate cold enough to provide effective hours
of economization; Glycol-based systems operate effectively at
the widest range of outdoor ambient temperatures
■
Wider operating range results in 2x–3x more effective hours than
air economizer systems in most climates
■
No outside air is introduced to the data center, so the ltration
and humidication functions of the CRAC unit operate normally
to ensure optimal air quality and relative humidity
■
Service requirements and complexities are reduced compared
to air-side economizers; less lter changing and maintenance are
required
■
Compatible with Liebert DS, Liebert CW, Liebert Challenger 3000
and Liebert XD precision cooling systems (downow and upow)
Challenges
■
Indirect piping and control are more complex
■
Higher initial capital costs
■
Added water use for cooling tower
Advantages
■
Compatible with moderate climates
■
More operating hours than uid-side economizers, if
humidication is added
■
Can be used on systems that don’t use water for heat rejection
■
Lower initial capital costs
■
Uses less water than uid-side economizers
■
Compatible with Liebert DS and Liebert CW precision cooling
products (downow only)
Challenges
■
Ductwork required to get air into IT space
■
Narrower range of effective hours of operation if used without
humidication
■
Dust and pollen sensors are required to minimize lter
maintenance; humidity control can be costly and challenging
■
Need proven, intelligent controls to ensure proper temperature
and humidity
■
High-density applications may require more localized cooling
■
Mildew minimization actions required
3
Fluid-Side Cooling Economization Strategy
Fluid-side economizers work in
conjunction with a heat rejection loop
− consisting of either a cooling tower,
evaporative cooler or drycooler − to
satisfy cooling requirements.
These systems are incorporated into either
a chilled water or glycol-based cooling
system. For economizer operation, the uid
used in the cooling system passes through
an additional heat exchanger to cool the
room air, reducing or eliminating the use of
cooling compressors and pumps.
Energy-efcient Liebert technologies
are well suited to uid-side cooling
economization.
GLYCOOL Cooling
for Liebert DSTM and Liebert ChallengerTM 3000
How the Liebert GLYCOOL System Works
The self-contained Liebert GLYCOOL system comprises a compressorized Liebert glycol
system with advanced controls, a standard cooling coil, an additional “Econ-o-coil” free
cooling coil and a drycooler.
At ambient temperatures above the CRAC return temperature (less the drycooler
approach), the system functions as a normal glycol-cooled system. As outdoor
temperatures drop, the temperature of the uid in the heat rejection loop drops also.
Once it is cold enough outside, the control opens the modulating valve to the Econ-o-coil
circuit. Depending on ambient conditions, the system either reduces or eliminates cooling
compressor and pump operation.
Savings
The Liebert GLYCOOL system delivers an average annual energy savings of 20–50%.
A-frame coil inside
Econ-o-coil rests
on A-frame coil
Liebert
Drycooler
Centrifugal
blower
Compressors
Liebert GLYCOOL System
Providing free cooling by using outside air through the Econ-o-coil circuit to maximize cooling
efciencies
Glycol-cooled
condensers
and Paradenser
tubes
Glycol
circulating
pump
4
Chiller Plant
Partnered with Liebert CWTM and Liebert Challenger 3000
How Chiller Plant Economization Works
The chilled water loop that feeds multiple chilled water-based CRAC units uses cold outdoor
temperatures to cool the chilled water loop, effectively reducing pump operation.
Full economization hours are dependent upon the outdoor wet bulb temperature,
the approach of the cooling tower and heat exchanger, and the chiller water supply
temperature. Partial economization hours are dependent upon the factors listed above, as
well as the chilled water return temperature.
Savings
A chiller plant, partnered with Liebert precision cooling technologies, delivers an average
annual energy savings of 40–60%.
Cooling TowerPumpCRAC Units
Why Liebert Products and Services?
■
Liebert iCOM® Control – Based on
years of data center precision cooling
experience, the intelligent Liebert iCOM
control dynamically optimizes the
operating parameters of uid-side
economizer solutions
Provides advanced
control and
monitoring, which
allows units to work
together as a single
system to enhance performance and
improve efciency
■
Service − Industry-leading
local service and support
network ensures timely
maintenance, service and
parts availability
■
Industry Leadership –
Liebert advanced technologies
can help you cut operating costs,
improve efciencies, reduce energy
consumption, ensure reliable
performance and maintain optimal
conditions within your IT environment
■
Compatibility – The Liebert GLYCOOL
system is available on Liebert DS and
Liebert Challenger 3000 (both downow
and upow)
Chiller
Plate Heat E xchanger
Economizer System Chiller Plant
Fluid ow during uid-side cooling economization – taking advantage of environmental conditions
to improve cooling efciencies
Liebert CW Chilled
Water Based Precision
Cooling is designed to
handle high heat loads
– using an existing
building chiller as a
chilled water cooling
source
Liebert Challenger 3000
provides complete
control of temperature,
humidity and air ltration
Liebert DS Precision
Cooling System
provides efcient,
precise, reliable control
of room temperature,
humidity and airow
for operation-critical
equipment
5
Air-Side Cooling Economization Strategy
Air-side economizers use outside air to
supplement data center cooling. They
utilize a system of sensors, ducts and
dampers to control the entry of outside
air to help satisfy cooling demands.
Sensors monitor outside and inside air
conditions, and when outside conditions
are suitable for cooling, the economizer
adjusts the dampers to introduce the
outside air, making it the primary cooling
source. This “free cooling” reduces
or eliminates the need for cooling
compressors, resulting in increased
efciencies and signicant energy savings.
Full “free cooling” is attained when the
outside air is below the entering cold aisle
temperature.
Partial benet is attained when the outside
air temperature is 2 degrees Fahrenheit
lower than the air temperature returning
to the Cooling Room Air Handlers and dew
point is less than 59 degrees and above 41.9
degrees Fahrenheit.
Air Economizer System
Liebert Air Economizer System installed on a Liebert CW chilled water-based precision
cooling system in downow conguration – using lower outside temperatures to minimize
cooling compressor and pump use.
Normal data center
cooling operation
“Free cooling” using lower
outside temperatures to
effectively cool the data center
Maximizing Economization with Liebert iCOM Control
Intelligent Liebert iCOM control is ideally suited for sensing and controlling Liebert economizers
− or those supplied by other manufacturers.
Multiple parameters within an IT environment add complexity and can be difcult to monitor
and manage, but the Liebert iCOM control simplies oversight and puts you back in control −
with substantial benets over custom congured controls.
Liebert iCOM control:
■
Factory tested and warranted
■
Offers multiple levels of monitoring and control – and compatibility with Liebert SiteScan® Web
■
Provides consistent, eld-proven operation
■
Shares a common platform with Liebert Precision Cooling Systems
■
Equipped with factory-provided installation, operation and maintenance instructions
■
Supported by factory-trained technicians
6
Lieber t iCOM Control System
Liebert Air Economizer System
with Liebert iCOM Control for Liebert DS and Liebert CW
How the Liebert Air Economizer System Works
The Liebert Air Economizer System reduces cooling costs by taking advantage of cool outdoor
air to condition indoor spaces, reducing or eliminating compressor operation in Liebert DS
units, and eliminating pump operation in Liebert CW, as well as reducing or eliminating the
compressor operation of the supporting chiller plant. The Liebert Air Economizer System is
equipped with high-efciency ltration and a sensor network that detects clogged lters –
and it communicates with your existing Business Management System.
The Liebert Air Economizer system comprises a plenum with air mixing box; dual enthalpy
controls with Liebert iCOM control (temperature/humidity sensors for outdoor air, return air
and supply air). The Liebert Air Economizer system must be applied to each CRAC unit.
Three Stages of Cooling
Depending on environmental conditions, the Liebert Air Economizer will adjust to cool your
IT environment with:
■
100% outdoor air
■
Mixed outdoor air and compressor/pump cooling
■
100% compressor/pump cooling
Why Liebert Products and Services?
■
Liebert iCOM control – Dynamically
optimizes both the precision cooling
system and the operating parameters of
air-side economizer systems
■
Temperature and humidity sensors –
Our sensors focus on both temperature
and humidity, because ignoring the
impact of humidity can have a serious
short- and long-term impact on
your IT equipment and your facility’s
infrastructure
■
Service − Industry-leading
local service and support
network ensures timely
maintenance, service and
parts availability
■
A long history of success
– Liebert DS and Liebert CW represent
the newest generation of the industry’s
most reliable and popular precision
cooling system, the Liebert Deluxe
System/3
■
Compatibility – The Liebert Air
Economizer System can be used with the
Liebert DS and Liebert CW – as well as
the Liebert iCOM Control
Liebert CW Chilled
Water Based Precision
Cooling is designed to
handle high heat loads
Savings
The Liebert Air economizer system delivers an average annual energy savings of 30–60%.
Solution Compatibility
Liebert
iCOM
Control
Lieber t DS upow
Lieber t DS downow
Lieber t CW upow
Lieber t CW downow
Lieber t XDTM Systems
Lieber t Challenger 3000
Lieber t Deluxe System/3TM
downow systems retrotted
with Liebert iCOM controls
GLYCOOL
Cooling
XX
XXX
XXX
XXX
Chiller Plant
Economization
XX
XXX
XX
Liebert Air
Economizer
Liebert DS Precision
Cooling System
provides precise,
reliable control of
room temperature,
humidity and airow
7
Ensuring the High Availability of
Mission-Critical Data and Applications.
Emerson Network Power, a business of Emerson (NYSE: EMR), is the
global leader in enabling Business-Critical Continuity™ from grid to chip
for telecommunication networks, data centers, health care and industrial
facilities. Emerson Network Power provides innovative solutions and
expertise in areas including AC and DC power and precision cooling
systems, embedded computing and power, integrated racks and
enclosures, power switching and controls, monitoring, and connectivity.
All solutions are supported globally by local Emerson Network Power
service technicians. Liebert AC power, precision cooling and monitoring
products and services from Emerson Network Power deliver Efciency
Without Compromise™ by helping customers optimize their data center
infrastructure to reduce costs and deliver high availability.
Emerson Network Power
Liebert Corporation
World Hea dquarters
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
United States O f America
800 877 9222 Phone (U.S. & C anada Only)
614 888 0246 Phone (Out side U.S.)
614 841 6022 FAX
Emers on Network Po wer
European Headquarters
Via Leonardo Da V inci 8
Zona Industrial e Tognana
35028 Piove Di Sa cco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emers on Network Po wer Asia Pacic
29/F, The Orient Square Building
F. Ortigas Jr. Road, Orti gas Center
Pasig City 1605
Philippines
+63 2 687 6615
+63 2 730 9572 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
While eve ry preca ution has bee n taken to ensur e accurac y and
complet eness in this l iterature , Liebert C orporati on assumes no
responsibility, and disclaims all liability for damages resulting
from use o f this informa tion or for any e rrors or om issions.