Emerson Liebert Economizer Solutions Brochures and Data Sheets

Liebert Economizer Cooling Solutions
Reduce Cooling Costs by up to 50% Without Compromising Reliability
Precision Cooling for Business-Critical Continuity
TM
Lower Cooling Energy Consumption by up to 50%
Fluid- and Air-side economizers take advantage of cold outside
temperatures to provide “free cooling” cycles that reduce or
eliminate the operation of data center precision cooling system
Using economizers, you can lower cooling energy usage by up
to 50% − depending on the average ambient temperature and humidity of your site.
A Focus on Energy Efficiency
While many IT professionals are considering economizers in preparation for potential code or legislation changes, a move toward improved efciencies can pay off with rewards of its own − especially in terms of lower operating costs and utility incentives. For example, some utility companies offer rebates for using energy­efcient equipment, quickly increasing your return on investment and overall savings.
Geographic regions of greatest cooling economization opportunity
Consider Chiller Plant Economizer Consider Chiller Plant or GLYCOOL Cooling Economizer Consider Chiller Plant or Air Economizer Consider Chiller Plant, Air Economizer or GLYCOOL Cooling Economizer
Industry Best Practices
When making the choice to use an economizer solution, it is critical to analyze how changes will impact your entire data center.
®
Industry thought leader ASHRAE
recommends that IT professionals investigating the use of economizers in their data centers consider the impact of incorrect application, and/or maintenance/ operational issues, on the life of protected sensitive equipment:
High humidity can cause condensation that reduces server life and
affects operation
Low dew point can result in problems such as static electricity
Gaseous or particulate contaminants can adversely affect sensitive
electronics
Operational reliability, including redundancy, is required to
achieve IT initiatives
Reliable water sources for cooling towers
Chiller condensate sump heaters for cold climate operation (or
other solutions)
Why Emerson Network Power?
For more than 40 years, Liebert technologies have led the industry in precision cooling for data centers, including economizing solutions such as the free-cooling GLYCOOL system.
Our depth and breadth of experience make us uniquely prepared to serve as trusted advisors to IT professionals. Liebert representatives can help you decide which economization method is the right solution for your application. They will guide you through the complexities of environmental factors affecting your decision making, including temperature ranges, dew point, humidity, and the issue of gaseous and particulate contaminants, as well as maintenance issues that impact all types of econimizers.
It’s how we deliver Efciency Without Compromise™ − providing high availability products with energy-efcient technologies.
Efciency Without Compromise
Efciency Without Compromise provides a path to optimize data center infrastructure around design, operating and management efciencies – while maintaining or improving availability. This is achieved through the proper selection and utilization of cooling, power and monitoring technologies, supported by key services and local expertise.
INFRASTRUCTURE MANAGEMENT
Impro ving perfo rmance of the IT i nfrastru cture and environment
ECO AVAILABILITY
Balan cing high leve ls of availability and efciency
2
FLEX CA PACITY
Adapti ng to IT change s for continuous optimization and design exibility
HIGH DENS ITY
Delivering architectures from 10- 60kW/rack to minimi ze space and cos t
Atlanta Chicago Seattle
Fluid Economizer Liebert
Cooling
Tower
Dry-
cooler
CW or DS
with Air
Economizer Full Economizer Hours 25% 17% 18% 48% 41% 14% 39% 23% 27% Partial Economizer Hours 52% 34% 33% 39% 28% 22% 61% 61% 15% Estimated Total Energy Savings 51% 36% 34% 67% 58% 25% 70% 49% 34%
The effect of ambient conditions in representative cities on economization hours and resultant energy savings, using different economization methods (assumes cold aisle temperature 71°–80° F; CRAC return temperature 85° F). Cooling tower calculations were made with Liebert chilled water-based precision cooling products. Drycooler calculations were based on Liebert precision cooling products equipped with GLYCOOL option. Air economizer calculations based on 41.9° F dew point limitation.
Fluid Economizer Liebert
Cooling
Tower
Dry-
cooler
CW or DS
with Air
Economizer
Fluid Economizer Liebert
Cooling
Tower
Dry-
cooler
CW or DS
with Air
Economizer
Liebert Precision Cooling Economization
In accordance with ASHRAE’s guidance, and in keeping with our position as the industry’s power and cooling leader, Emerson Network Power provides effective, efcient economizer solutions. Emerson Network Power offers uid-side economization solutions and an air-side economizer – and Liebert technologies are well suited to work with economization solutions from third-party providers.
No economizer
Full economizer
Partial economizer
Potential dependant on dew point
Comparative hours of economizer operations through varying CR AC supply and return temperatures in three cities representing distinct ambient conditions (partial economizer operation = outside ambient used to precool or assist in cooling of data center return air).
Fluid-Side vs. Air-Side Economization Comparison
Fluid-Side Air-Side
Advantages
Can be used in any climate cold enough to provide effective hours
of economization; Glycol-based systems operate effectively at the widest range of outdoor ambient temperatures
Wider operating range results in 2x–3x more effective hours than
air economizer systems in most climates
No outside air is introduced to the data center, so the ltration
and humidication functions of the CRAC unit operate normally to ensure optimal air quality and relative humidity
Service requirements and complexities are reduced compared
to air-side economizers; less lter changing and maintenance are required
Compatible with Liebert DS, Liebert CW, Liebert Challenger 3000
and Liebert XD precision cooling systems (downow and upow)
Challenges
Indirect piping and control are more complex
Higher initial capital costs
Added water use for cooling tower
Advantages
Compatible with moderate climates
More operating hours than uid-side economizers, if
humidication is added
Can be used on systems that don’t use water for heat rejection
Lower initial capital costs
Uses less water than uid-side economizers
Compatible with Liebert DS and Liebert CW precision cooling
products (downow only)
Challenges
Ductwork required to get air into IT space
Narrower range of effective hours of operation if used without
humidication
Dust and pollen sensors are required to minimize lter
maintenance; humidity control can be costly and challenging
Need proven, intelligent controls to ensure proper temperature
and humidity
High-density applications may require more localized cooling
Mildew minimization actions required