Emerson Libert AC Power System User Manual

AC Power Systems f
or Business-Critical Continuity
Liebert MP Advanced Power Strips
Managed Power Strips Provide Easy-To-Use Distribution, Monitoring And Control For IT Rack/Enclosure Applications
TM
As Rack Power Requirements Rise, So Does The Need To Manage Power To Each Piece Of Equipment
iebert MP - Advanced Power Strip Rackmount
IT managers are demanding more of their load-level
power management — more power, multiple
connections and network monitoring capabilities.
L
Many IT and networking centers are experiencing
higher load densities with more servers and
components packed into rack after rack. This has
created a clear need to find a way to monitor and
manage the power to all of these loads.
The Solution
Liebert MP Advanced Power Strips, with remote
monitoring and/or control capabilities for power
distribution at the load/equipment level, are designed
to support the growth in rack electrical needs while
meeting the new demands for remote power
management.
These products are a part of the Liebert MP Product
Family — a group of power distribution and switching
systems designed to manage power from the UPS all
the way to each individual piece of computing and
communications hardware.
Who Needs The Advantages Of Advanced Power Strips?
n
IT and network managers who are experiencing
high electrical load densities and looking for a way
to monitor and manage loads at the strip and
receptacle in the data center or network closet.
n
Facility managers who want to control panel
zation and protect against
li
ti
d u
ar
bo
vertent overloading.
d
a
in
onitoring And Control Capabilities
M
While local displays on the Liebert MP Advanced
Power Strips provide operating information, the key
aspect of the design is the remote monitoring
capabilities. Using the strip’s serial interface, you can
connect to the Web through Liebert OpenComms™
EM or a Liebert Access Server.
Liebert MP Advanced Power Strips are designed
to provide an expanding level of monitoring and
control capabilities for your entire network of
managed power distribution devices, including:
n
SNMP support.
n
E-mail alarm notification.
n
On-board graphing with OpenComms™ EM.
Liebert MP Advanced Power Strips Deliver:
Load monitoring and control — Support
continuous uptime, minimizes disruptions.
Expandable monitoring interface — Simplified
growth management.
True power monitoring — More exact
than calculated values.
High reliability — PCB receptacle mount construction.
enience
v
n
o
C
— F
Liebert Foundation™ rack enclosure system.
y installed option in the
or
t
ac
mo Sites:
e
e D
-lin
n
O
mo.liebert.com
e
bd
e
w
p
://m
http http://emwebdemo.liebert.com
2
emote/Network Access
R
Ethernet
More Configurations For More Flexibility
Liebert MP Advanced Power Strips are offered in two basic systems:
Liebert MP-M Series — Monitors electrical attributes of an individual
power strip. Provides real-time remote and local display of total strip
true RMS volts, amps and watts. Other capabilities include:
n
Ambient temperature measurements.
n
Easy viewing LCD that displays power readings.
n
Re-nameable receptacles for inventory tracking.
n
Telnet and SNMP Support.
n
Audible alarm and receive alarms based on preset thresholds.
n
User authentication for added security.
n
Vertical or horizontal rack-mounted versions.
OpenComms EM
OpenComms EM 1 or 2 Power Strips
MP-S Access Server
MP-S Access Server 1 to 32 Power
trips / Expandable
S
Liebert MP-C Series — These controlled power strips provide the
same remote monitoring capabilities as the MP-M Series with the
addition of individual, remote receptacle on/off control and local
display of powered receptacles. This added capability allows you to:
n
Reboot unresponsive equipment.
n
Turn off unused receptacles.
n
Link receptacles to manage load groups.
n
Log and maintain receptacle connectivity.
n
Audit circuit prior to plugging in more equipment.
n
Audible and LED alarm warnings.
A Choice Of Capacities And Receptacles
pport the increasing electrical loads in network equipment, Liebert
o su
T
dvanced Power Strips are offered in higher voltage and amp ratings
MP A
than standard multi-outlet units. A number of power control, distribution
and receptacle configuration options are available, including:
n
Single-phase input/output, 120VAC & 208VAC.
n
Three-phase input/single-phase output.
n
15-30 amp capacities, single NEMA input plug,
tput receptacles.
u
C o
NEMA or I
n
1U rack-mount and zero U vertical
mo
n
Rack-mount with 8-10 outlets,
vertical with 12-24 outlets.
E
unt configurations.
Liebert Brings You End To End Solutions For Your Critical IT Systems Support
Liebert MP Advanced Power Strips are just part
of our optimized “end to end” solutions, providing
power and environmental support from the rack
tire critical space. As always, the
gh the e
u
o
on thr
Liebert objective is supporting business continuity,
otecting your business critical systems and
y pr
b
tworks against the causes of downtime.
ne
n
N
w
t
e
ork Card
Expansion Cards
3
We Help You Get It Right–
Emerson Network Power.
The global leader in enabling Business-Critical Continuity.
EmersonNetworkPower.com
AC Power Systems
Connectivity DC Power Systems
Embedded Power Integrated Cabinet Solutions Outside Plant
Power Switching & Controls Precision Cooling
Site Monitoring Surge & Signal Protection
Services
Right From The Start
NPUT (Rated) Connection(s) OUTPUT (Rated) Connection(s)
I
Form Factor Voltage Current Phase Type Quan Length Voltage Current Phase Type Quan LCD/LED Part Number
iebert MP Advanced Power Strips (Monitoring)/ MP-M Series
L
Rckmnt / 1U 120 15 1PH 5-15P 1 6' 120 15 1PH 5-15/20R 10 LCD MP-M5109
ckmnt / 1U 120 20 1PH 5-20P 1 6' 120 20 1PH 5-15/20R 10 LCD MP-M5110
R
Rckmnt / 1U 120 20 1PH L5-20P 1 6' 120 20 1PH 5-15/20R 10 LCD MP-M5111
ckmnt / 1U 120 30 1PH L5-30P 1 6' 120 30 1PH 5-15/20R 10 LCD MP-M5112
R
ckmnt / 1U 200-240 20 1PH L6-20P 1 6' 200-240 20 1PH IEC- C13 10 LCD MP-M5113
R
Rckmnt / 1U 200-240 30 1PH L6-30P 1 6' 200-240 30 1PH IEC-C13 10 LCD MP-M5114
ert / 33.25" 120 15 1PH 5-15P 1 10' 120 15 1PH 5-15/20R 12 LCD MP-M5115
V
Vert / 33.25" 120 20 1PH 5-20P 1 10' 120 20 1PH 5-15/20R 12 LCD MP-M5116
ert / 33.25" 120 20 1PH L5-20P 1 10' 120 20 1PH 5-15/20R 12 LCD MP-M5117
V
Vert. / 50.75" 120 20 1PH 5-20P 1 10' 120 20 1PH 5-15/20R 24 LCD MP-M5118
ert. / 50.75" 120 20 1PH L5-20P 1 10' 120 20 1PH 5-15/20R 24 LCD MP-M5034
V
Vert. / 50.75" 120 30 1PH L5-30P 1 10' 120 30 1PH 5-15/20R 24 LCD MP-M5035
Vert. / 57.75" 200-240 20 1PH L6-20P 1 10' 200-240 20 1PH IEC-C13 24 LCD MP-M5036
Vert. / 57.75" 200-240 30 1PH L6-30P 1 10' 200-240 30 1PH IEC-C13 24 LCD MP-M5037
Vert. / 68.25" 120/208 20 3PH L21-20P 1 10' 208 & 120 20 1PH IEC-C13 +5-20R 24+2 LED MP-M5119
Liebert MP Advanced Power Strips (Controlled)/ MP-C Series
Rckmnt / 1U 120 15 1PH 5-15P 1 6' 120 15 1PH 5-15/20R 8 LCD / LED MP-C5120
Rckmnt / 1U 120 20 1PH 5-20P 1 6' 120 20 1PH 5-15/20R 8 LCD / LED MP-C5121
Rckmnt / 1U 120 20 1PH L5-20P 1 6' 120 20 1PH 5-15/20R 8 LCD / LED MP-C5122
Rckmnt / 1U 120 30 1PH L5-30P 1 6' 120 30 1PH 5-15/20R 8 LCD / LED MP-C5123
Rckmnt / 1U 200-240 20 1PH L6-20P 1 6' 200-240 20 1PH IEC-C13 8 LCD / LED MP-C5124
Rckmnt / 1U 200-240 30 1PH L6-30P 1 6' 200-240 30 1PH IEC-C13 8 LCD / LED MP-C5125
Vert. / 68.25" 120 20 1PH 5-20P 1 10' 120 20 1PH 5-15/20R 20+1 LCD / LED MP-C5147
Vert. / 68.25" 120 20 1PH L5-20P 1 10' 120 20 1PH 5-15/20R 20+1 LCD / LED MP-C5148
t. / 68.25"
r
e
V
t. / 68.25"
r
e
V
Vert. / 68.25" 200-240 30 1PH L6-30P 1 10' 200-240 30 1PH IEC-C13 20+1 LCD / LED MP-C5133
Vert. / 68.25" 120/208 20 3PH L21-20P 1 10' 120 20 1PH 5-15/20R 21 LCD / LED MP-C5134
Vert. / 68.25" 120/208 20 3PH L21-20P 1 10' 208 20 3PH/1PH
Vert. / 68.25" 120/208 30 3PH L21-30P 1 10' 208 30 3PH/1PH
L
iebert MP Advanced Power Strips (Access Series)/ MP-S Series
Form Factor Input Voltage Input Plug Length PDU's Supported Installed Network Cards Installed RS232 Cards Part Number
Rckmnt / 1U 120 5-15P 6' 4 (Expand to 8) 1 1 MP-S5137-125
Rckmnt / 1U 200-240 IEC-C14 6' 4 (Expand to 8) 1 1 MP-S5137-230
Rckmnt / 1.5U 120 5-15P 6' 4 (Expand to 20) 1 1 MP-S5138-125
Rckmnt / 1.5U 200-240 IEC-C14 6' 4 (Expand to 20) 1 1 MP-S5138-230
Rckmnt / 2U 120 5-15P 6' 4 (Expand to 32) 1 1 MP-S5139-125
Rckmnt / 2U 200-240 IEC-C14 6' 4 (Expand to 32) 1 1 MP-S5139-230
Expansion Module
Form Factor Type Input Voltage Connection Part Number
Card RS-232 NA 4X RS232 MP-DS74
120 30 1PH L5-30P 1 10' 120 30 1PH 5-15/20R 20+1 LCD / LED MP-C5131
200-240 20 1PH L6-20P 1 10' 200-240 20 1PH IEC- C13 20+1 LCD / LED MP-C5132
NEMA L21-20 + IEC320 C13
NEMA L21-20 + IEC320 C13
onitoringLiebert
M
1 + 18
LCD / LED MP-C5135
1 + 18
LCD / LED MP-C5136
Liebert Corporation
earborn Drive
1050 D
.O. Box 29186
P
olumbus, Ohio 43229
C 800 877 9222 P
anada Only)
C 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX
Via Leonardo Da Vinci 8
ona Industriale Tognana
Z 35028 Piove Di Sacco (PD)
aly
It 39 049 9719 111 P 39 049 5841 257 FAX
Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX
hone (U.S. &
hone
liebert.com
24 x 7 Tech Support
800 222 5877 P 614 841 6755 (outside U.S.)
While every precaution has been taken to ensure accuracy and completeness in this literature, Lieber t Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
© 2006 Li the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
ir r
f the
o
® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.
SL-20800 (R2/06) Printed in USA
hone
bert Corporation. All rights reserved throughout
e
e owners.
v
ti
pec
s
e
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co.