Emerson 299H, S200 Installation Instructions

Installation Sheet
March 2000
Type 299H, 299HS, or S200
Type 299H, 299HS, or S200 Retro-Fit of Stabilizing Parts
RECESSED 1/16 THRU 1/8-INCH (1,59 THRU 3,17 mm)
16
CLIP
111
CONTACT
Figure 1. Stabilizing Boost Cartridge
19
Kit Part Number RS200XRT012
Installation
1. Remove disk holder assembly (key 16, Figure 1).
2. Press in the plastic boost cartridge assembly (key 111, Figure 1) with both thumbs until it contacts the end of the stem guide inside the boost throat of the lower casing.
Note
The top edge of the plastic boost cartridge assembly should be recessed 1/16 thru 1/8-inch (1,59 thru 3,17 mm) per Figure 1.
58
Figure 2. Vent Assembly in Spring Case
(not applicable for Types 299H and 299HS)
For Type S200 Only
3. If necessary, replace the metal vent seat ring (key 58, Figure 2) in the spring case vent. Replacement is not necessary for Type S200 regulators shipped before 1985 or after October 1992.
Note
The new vent seat ring has only 1 small hole (1/16-inch diameter (1,59 mm)) in addition to the 3 screw holes. The old vent seat ring had 3 larger holes (5/32-inch diameter (4,00 mm)) in addition to the 3 screw holes.
www.emersonprocess.com/regulators
D300902X012
Type 299H, 299HS, or S200
Industrial
USA - Headquarters McKinney, Texas 75070 USA Tel: 1-800-558-5856 Outside U.S. 1-469-293-4201
Asia-Pacic
Shanghai, China 201206 Tel: 86-21-5899 7887
Europe Bologna, Italy 40013 Tel: 39 051 4190611
For further information visit www.emersonprocess.com/regulators
The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc., a business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties
or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specications
of such products at any time without notice.
Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management product remains solely with the purchaser.
©Fisher Controls International, Inc., 2000; All Rights Reserved
Natural Gas Technologies
USA - Headquarters McKinney, Texas 75070 Tel: 1-800-558-5856 Outside U.S. 1-469-293-4201
Asia-Pacic
Singapore, Singapore 128461 Tel: +65 6777 8211
Europe Bologna, Italy 40013 Tel: 39 051 4190611 Gallardon, France 28320 Tel: +33 (0)2 37 33 47 00
Industrial/High Purity
TESCOM Elk River, Minnesota 55330 USA Tel: 1-763-241-3238 Selmsdorf, Germany 23923 Tel: +49 (0) 38823 31 0
Loading...