Please read this manual completely before operating your room air conditioner.
01 electrolux welcome
contents electrolux 02
Welcome to the world of
simple handling and no worries.
Thank you for choosing Electrolux. This manual contains all of the information
required to guarantee your safety and the appropriate use of your air
conditioner.
Please read all of the instructions before using the air conditioner and keep this
manual for future reference.
We know you will enjoy your new air conditioner and thank you for choosing our
product. We hope you will consider us for future purchase.
Environmental Advices
The packaging material used is recyclable; we
recommend that you separate plastic, paper and
cardboard and give them to recycling companies.
According to WEEE (Waste of Electrical and
Electronic Equipment) guidelines, waste from
electrical and electronic devices should be
collected separately. If you need to dispose of this
appliance in the future, do NOT throw it away with
the rest of your domestic garbage. Instead, please
take the appliance to the nearest WEEE collection
point, where available.
The air conditioner you purchased has R410a gas
refrigerant a environmental friendly gas which does
not damage the ozone layer.
The air conditioner that you have bought may be slightly different from the one
illustrated in this manual. Please refer to the information related to the model
you have.
This air conditioner is for domestic use only. It is not reccomended for
commercial or industrial use.
The air conditioner you have may carry a different plug than the one illustrated
in this manual. The plug that comes with the product follows the electrical
specification of the country where it is sold.
To prevent injury to the user or other people and property damage, the following
instructions must be followed.
Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
1. Connect with the power properly.
Otherwise, it may cause electric
shock or fire due to excess heat
generation.
2. Do not modify power cord length
or share the outlet with other
appliances. It may cause electric
shock or fire due to heat
generation.
3. Always ensure effective earthing.
No earthing may cause electric
shock.
4. Disconnect the power if strange
sounds, smell, or smoke comes
from it. It may cause fire and
electric shock.
5. Keep firearms away. It may cause
fire.
6. Do not operate or stop the unit by
switching on or off the power. It
may cause electric shock or fire
due to heat generation.
7. Do not operate with wet hands or
in damp environment. It may cause
electric shock.
8. Do not allow water to run into
electric parts. It may cause failure
of machine or electric shock.
9. Do not drink water drained from air
05 electrolux safety precautions
safety precautions electrolux 06
conditioner. It contains
contaminants and could make you
sick.
10.Do not use the power cord close to
heating appliances. It may cause
fire and electric shock.
11.Do not damage or use an
unspecified power cord. It may
cause electric shock or fire.
12.Do not direct airflow at room
occupants only. This could damage
your health.
13.Always install circuit breaker and a
dedicated power circuit. No
installation may cause fire and
electric shock.
14.Do not open the unit during
operation. It may cause electric
shock.
15.Do not use the power cord near
flammable gas or combustibles,
such as gasoline, benzene, thinner,
etc. It may cause an explosion or
fire.
16.Ventilate room before operating air
conditioner if there is a gas leakage
from another appliance. It may
cause explosion, fire and, burns.
17.Do not disassemble or modify unit.
It may cause failure and electric
shock.
18.When the air filter is to be removed,
do not touch the metal parts of the
unit. It may cause an injury.
19.Do not clean the air conditioner
with water. Water may enter the
unit and degrade the insulation. It
may cause an electric shock.
20.Ventilate the room well when used
together with a stove, etc. An
oxygen shortage may occur.
21.When the unit is to be cleaned,
switch off, and turn off the circuit
breaker. Do not clean unit when
power is on as it may cause fire
and electric shock, it may cause
an injury.
22.Do not put a children, pet or house
plant where it will be exposed to
direct air flow. This could injure the
pet or plant.
23.Do not use for special purposes.
Do not use this air conditioner to
preserve precision devices, food,
pets, plants, and art objects. It
may cause deterioration of quality,
etc.
24.Stop operation and close the
window in storm or hurricane.
Operation with windows opened
may cause wetting of indoor and
soaking of household furniture.
25.Turn off the main power switch
when not using the unit for a long
time. It may cause failure of
product or fire.
26.Do not use strong detergent such
as wax or thinner. Use a soft cloth
for cleaning. Appearance may be
deteriorated due to change of
product color or scratching of its
surface.
27.Ensure that the installation bracket
of the outdoor appliance is not
damaged due to prolonged
exposure. If bracket is damaged,
07 electrolux safety precautions
choosing the installation site electrolux 08
Choosing the installation site
there is concern of damage due to
falling of unit.
28.Always insert the filters securely.
Clean filter once every two weeks.
Operation without filters may
cause failure.
29.Do not place heavy object on the
power cord and take care so that
the cord is not compressed. There
is danger of fire or electric shock.
30.Do not place obstacles around airinlets or inside of air-outlet. It may
cause failure of appliance or
accident.
Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably
install the unit at one of these sites, please consult your local distributor
beforehand:
1. Site with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
Indoor Unit
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight
of the indoor unit.
3. The site must be easily accessible
7. The indoor unit must be at least 2.3
meters (7.5 feet) from the ground.
8. The site must allow for the easy
removal of the connector pipe and
drain hose.
9. The unit must be installed at a site
protected from direct sunlight.
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the
indoor unit, as shown in the
following figure.
5. There should be at least 1 meter (3
More
than 12cm
More
than 15cm
feet) between the unit and radio
and television devices. It is ideal
that the unit be installed at the
center of the environment.
More
than 200cm
More
than 12cm
6. It must be far from fire, smoke or
flammable gases.
09 electrolux outdoor unit
parts list electrolux 10
Parts list
Outdoor Unit
1. The outdoor unit must be installed
at a convenient site that is not
exposed to strong winds. The site
should be dry and well ventilated.
2. The site must support the weight
of the outdoor unit and allow for
vertical installation.
3. There must not be the possibility of
increased noise and vibration at
the site.
4. The unit must be installed at a site
where the noise produced by its
operation and air discharge does
not disturb the neighbors or
animals.
5. The site cannot have any leakage
of flammable gases.
6. The site must allow for a piping
extension of no less than 5 meters
(16 feet) and for pipes measuring
at least 10 meters (33 feet) in
length.
7. The site must provide enough
space around the unit, as shown in
the diagram.
8. Children must not be able to
access the installation site.
More
than 30cm
More
than 200cm
More
than 60cm
More
than 30cm
More
than 60cm
NUMBERINGPART NAME
1
2
3
4
5
6
7
8
9
Indoor unit
Installation plate
Clip anchor
Self-tapping screw A ST3.9x25
Seal
Drain Joint
Connecting
pipe
assembly*
Remote controller
Self-tapping screw B ST2.9x10
Remote controller holder
Liquid side
Gas side
Ø6,35
Ø9,52
Ø12,7
54
(< modelos 12000 Btu’s)
(> modelos 12000 Btu’s)
9
8
87
QTY.
1
8
8
1
1
Parts you must
purchase
1
2
1
1
3
2
Outdoor unit
11 electrolux parts list
indoor unit installation electrolux 12
Indoor unit installation
More than 12cm
7
More than 15cm
Indoor unit
Air filter
More than 30cm
4
5
More than 200cm
A
B
6
More than 12cm
More than 60cm
1
2
6
More than
60cm
C
Outdoor
unit
Installation plate description
3
Indo
or un tlin
am
bove 120m
from the wall
it
ou
e
45
0
45
4
o s
M del
45
Model
R
f
ig
er
nt
e
h(
above 120mm
Refrigerant pipe
hole (left) Ø 65
pi
ra
lef
t
Ø
o
le )
Indoor unit outline
from the wall
p
e
6
5
293
abov
t
A
<
12000 B (
tu’
12000 B
tu’
above 150mm from
the ceiling
e
15 m fr
0m
c
i inghee
l
:
s
A B 0)
( :
s
A B
920
om
710, :
790, : 26
5)
n
ion plaI
stallat te
90
25
Installation plate
B
0
4
above 120mm
from the wall
90
Refrigerant pipe
45
hole (right) Ø 65
above
120mm
om fr
the wall
fant piRe riger pe
(
i )
hole
r ght
Ø
65
(A)
Indoor unit outline
above 120mm
from the wall
above 150mm from
the ceiling
45
305
Installation plate
272
above 120mm
from the wall
90
1. This illustration is for explanation purposes only.
2. Copper lines must be insulated independently
Refrigerant pipe
hole (left) Ø 65
Refrigerant pipe
45
80
489
850
45
hole (right) Ø 65
(B)
Modelos 18000 Btu’s
13 electrolux indoor unit installation
indoor unit installation electrolux 14
150mm del techo
above 120mm
from the wall
Refrigerant pipe
hole (left) Ø 65
293
130
50
Modelos 24000 Btu’s
Fixing the installation plate
1. Install the installation plate
horizontally over the structural
parts on the wall using the spaces
indicated on the plate, as shown in
the figure above.
2. In the case of tiled, concrete or
similar walls, create 5 mmdiameter holes. Place anchorage
supports for the appropriate
assembly screws.
3. If expansion screws are used, the
holes must measure 11x20 or
11x26, with a distance of 450 mm
between each.
4. Fix the installation plate to the wall.
Drilling the Hole
1. Determine the position of the hole
for the pipe using the installation
plate and drill the pipe hole (ø
65mm) so that it is titled slightly
downward.
2. Always use a pipe cover with an
opening when drilling a metal bar.
998
119380380
above 120mm
41
from the wall
130
50
Indoor unit outline
Fit the Installation Plate and drill holes
in the wall according to the wall
structure and corresponding mounting
points on the installation plate
(Dimensions are in “mm” unless
otherwise stated).
Placa de instalación
Wall
Indoor unit
Outdoor unit
5-7m m
Connective pipe and drainage installation
Drainage
1. Run the drain hose sloping
downward. Do not install the drain
hose as illustrated below.
2. When connecting extension drain
hose, insulate the connecting part
of extension drain hose with a
shield pipe, do not let the drain
hose slack.
Connective pipe installation
1. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel.
2. For the rear-right-hand and rear-lefthand piping, install the piping as
shown. Bend the connective pipe to
be laid at 43mm height or less from
the wall.
3. Fix the end of the connective pipe.
Fastening the Indoor Unit
1. Pass the piping through the hole in
the wall.
2. Put the upper claw at the back of the
indoor unit on the upper hook of the
installation plate, move the indoor
unit from side to side to see that it is
securely hooked (see Fig.10 &
Fig.11).
Pipe cover
(right)
Right piping
Indoor unit
outline
Do not block
water flow
by a rise.
Do not put the end
of drain hose into water.
Pipe
holder
Right back
piping
Connective
pipe
Upper hook
Lower hook
Do not block
water flow
by a rise.
Pipe cover
(left)
43mm
15 electrolux indoor unit installation
outdoor unit installation electrolux 16
Outdoor unit installation
3. Piping can easily be made by lifting
the indoor unit with a cushioning
material between the indoor unit
and the wall. Get it out after finish
piping.
4. Push the lower part of the indoor unit
up on the wall, then move the
indoor unit from side to side, up and
down to check if it is hooked
securely.
Piping and wrapping
1. Bundle the tubing, connecting
cable, and drain hose with tape
securely, evenly as shown.
2. Because the condensed water
from rear of the indoor unit is
gathered in ponding box and is
piped out of room. Do not put
anything else in the box.
Indoor unit
Drain hose
Cushioning
material
Cable
de conexión
Ponding
box
Pipe room
Connective
pipe
Wrapping
belt
1. Install the outdoor unit on a rigid
base to prevent increasing noise
level and vibration.
2. Determine the air outlet direction
where the discharged air is not
blocked. In the case that the
installation place is exposed to
strong wind such as a seaside,
make sure the fan operating
properly by putting the unit
lengthwise along the wall or using
a dust or shield plates.
3. Specially in windy area, install the
unit to prevent the admission of
wind. If need suspending
installation, the installation bracket
should accord with technique
requirement in the installation
bracket diagram.
4. The installation wall should be solid
brick, concrete or the same
intensity construction, or actions to
reinforce, damping supporting
should be taken. The connection
between bracket and wall, bracket
and the air conditioner should be
firm, stable and reliable.
5. Be sure there is no obstacle which
block radiating air.
Strong wind
1. Connect the indoor unit first, then the outdoor unit.
2. Do not allow the piping to let out from the back of the indoor unit.
3. Be careful not to let the drain hose slack.
4. Heat insulated both of the auxiliary piping.
5. Be sure that the drain hose is located at the lowest side of the bundle.
Locating at the upper side can cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring.
7. Run the drain hose sloped downward to drain out the condensed water
smoothly.
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.