Identification:
Y01 
Technical Bulletin
Bulletin no:  
Date: 
Issuer: 
Factory: 
Subject 
Model 
Problem 
Reason 
Actions in 
factory 
Actions in 
field
FRJ2006-16  
12/10/06  
C.CHAUSSAT  
FRJ Aubusson France 
Installation of a new power board with contactors 
TR22-TR23-TR24 : PNCs : 601373, 601471, 601472, 601415, 
601374, 601700, 601701, 601702, 601703, 601704. 
Destruction of relays and braking resistance on power board with 
Zetler relays and doubled resistance. 
_ 
Power board developped by TDC is replaced by a new board with 
contactors.. 
Application date: Year 2006, Week 28 – 
-  The new board keeps the same PNC. (OD5420). 
- Perfectly interchangeable. 
-  In case of destruction of the braking system, use only the new 
board. 