Efd VALVEMATE 6000 Operating Guide

VALVEMATE™ 6000 Valve Controller
Operating Manual
The VALVEMATE™ 6000 Valve Controller provides a compact, convenient interface between automatic assembly machines and EFD dispense valves. The assembly machine controls the dispense valve open and close function. Features include:
Easy installation
High-volume, fast-acting solenoid with
a dedicated power supply
Initiation via 5 to 24 VDC or dry contact closure
Selectable input voltage
Push-button valve purging
Quick-connect for valve air hose
Specifications
Size: 5.98" W x 5.70" D x 3.38" H
(15.2 x 14.5 x 8.6 cm) Weight: 2.25 lb (1.02 kg) Cabinet: Aluminum Input voltage: Selectable 100/120/220VAC
50/60Hz 18/15VA Internal voltage: 24 VDC Initiation: 5 to 24 VDC or contact closure Air input required: 70 psi minimum (4.8 bar) Output pressure: 70 psi (4.8 bar)
Control circuitry: Solid state
®
A NORDSON COMP ANY
US: 888-333-0311 UK: 0800 585733 Mexico: 001-800-556-3484
Getting Started
Spare fuse
220
Air Output
Fuse T 125mA 250V 100/120/220VAC 50/60Hz 18/15 VA
V
A
L
V
E
M
A
T
E
6
00
P
o
w
e
r
P
0
u
rg
e
Cartridge window
(check voltage indicated)
Mounting. If appropriate, attach the mounting bracket
and install the VALVEMATE A panel mount kit #7000PMK is available.
in the desired location.
Input Power. Check the voltage label on the input
voltage selector cartridge to ensure voltage is set properly. To change the voltage, remove the voltage selector from the cartridge and rotate so correct voltage shows through cartridge window. Reinstall cartridge and snap into position. Install power cord.
Initiate Connection. The VALVEMATE
be initiated by application of 5 to 24 VDC to the (+) and (-) terminals, or closure of mechanical contacts across the (+) and (-) terminals. If a solid state device is used for the 5 to 24 VDC initiation, a relay must be used with the relay contacts providing the closure. (The connector supplied with the unit can be used for either configuration.) As an alternate method, connection can be initiated with a standard EFD foot pedal #2015A (not supplied) plugged into the receptacle.
6000 can
Air Input 70 PSI (4.8 BAR) Minimum
Rear panel
22
0
120
0
0
1
Voltage value
Initiate
Initiate 5-24 VDC or Contact Closure
+
Air Input Connection. Connect the VALVEMATE
6000 to plant air by first installing the EFD five-micron filter regulator (#2000F755) to your air supply. Install the air tee with barb fitting (#1116) in the output of the filter regulator. A 10-ft 1/4" OD air line is supplied. Using the barb fitting supplied, connect one end to the #1116 air tee. Connect the other end of the air line by pushing it firmly into the air input connector on the VALVEMATE 6000
.
Set the pressure at the #2000F755 filter regulator to 70 psi (4.8 bar).
Control Air Output. Push the male quick-connect on
the valve air hose into the air output fitting on the back of the controller and turn clockwise to lock.
Valve Setup. Follow the setup instructions in the EFD dispense valve operating manual.
Operational Test. Place a container under the valve outlet. Turn on air and power. Press the PURGE button until fluid fills the line and flows from the valve outlet. The system is now ready for operation.
Typical Setup
Note: Use only oil-free, clean, dry filtered air.
Five micron filter regulator #2000F755
Power Purge
White quick-connect
Air tee #1116
VALVEMATE 6000
VALVEMATE 6000 controller
Shutoff valve
To exhaust To pressurize
Flexible air line #2310S
Fluid feed hose
5
20
0
EFD 752V-UH-SS Fluid dispense valve
Black quick-connect
Pressurized reservoir with air regulator
(1.0 liter tank shown)
Pressure relief valve
Material Constant air Pulsed air for valve operation
Loading...
+ 1 hidden pages