VALVEMATE™ 6000 Valve Controller
Operating Manual
The VALVEMATE™ 6000 Valve Controller provides a compact, convenient
interface between automatic assembly machines and EFD dispense valves.
The assembly machine controls the dispense valve open and close function.
Features include:
• Easy installation
• High-volume, fast-acting solenoid with
a dedicated power supply
• Initiation via 5 to 24 VDC or dry contact
closure
• Selectable input voltage
• Push-button valve purging
• Quick-connect for valve air hose
Specifications
Size: 5.98" W x 5.70" D x 3.38" H
(15.2 x 14.5 x 8.6 cm)
Weight: 2.25 lb (1.02 kg)
Cabinet: Aluminum
Input voltage: Selectable 100/120/220VAC
50/60Hz 18/15VA
Internal voltage: 24 VDC
Initiation: 5 to 24 VDC or contact closure
Air input required: 70 psi minimum (4.8 bar)
Output pressure: 70 psi (4.8 bar)
Control circuitry: Solid state
®
A NORDSON COMP ANY
US: 888-333-0311
UK: 0800 585733
Mexico: 001-800-556-3484
Getting Started
Spare fuse
➁
➄
220
Air Output
Fuse T 125mA 250V
100/120/220VAC
50/60Hz 18/15 VA
V
A
L
V
E
M
A
T
E
6
00
P
o
w
e
r
P
0
u
rg
e
Cartridge window
(check voltage indicated)
➀
➀ Mounting. If appropriate, attach the mounting bracket
and install the VALVEMATE
A panel mount kit #7000PMK is available.
™
in the desired location.
➁ Input Power. Check the voltage label on the input
voltage selector cartridge to ensure voltage is set
properly. To change the voltage, remove the voltage
selector from the cartridge and rotate so correct
voltage shows through cartridge window. Reinstall
cartridge and snap into position. Install power cord.
➂ Initiate Connection. The VALVEMATE
be initiated by application of 5 to 24 VDC to the (+)
and (-) terminals, or closure of mechanical contacts
across the (+) and (-) terminals. If a solid state
device is used for the 5 to 24 VDC initiation, a relay
must be used with the relay contacts providing the
closure. (The connector supplied with the unit can
be used for either configuration.) As an alternate
method, connection can be initiated with a standard
EFD foot pedal #2015A (not supplied) plugged into
the receptacle.
™
6000 can
➃
Air Input
70 PSI
(4.8 BAR)
Minimum
Rear panel
22
0
120
0
0
1
Voltage value
➂
Initiate
Initiate
5-24 VDC or
Contact Closure
+
➃ Air Input Connection. Connect the VALVEMATE
6000 to plant air by first installing the EFD five-micron
filter regulator (#2000F755) to your air supply. Install
the air tee with barb fitting (#1116) in the output of
the filter regulator. A 10-ft 1/4" OD air line is supplied.
Using the barb fitting supplied, connect one end to the
#1116 air tee. Connect the other end of the air line by
pushing it firmly into the air input connector on the
VALVEMATE 6000
™
.
Set the pressure at the #2000F755 filter regulator to
70 psi (4.8 bar).
➄ Control Air Output. Push the male quick-connect on
the valve air hose into the air output fitting on the back
of the controller and turn clockwise to lock.
Valve Setup. Follow the setup instructions in the EFD
dispense valve operating manual.
Operational Test. Place a container under the valve
outlet. Turn on air and power. Press the PURGE button
until fluid fills the line and flows from the valve outlet. The
system is now ready for operation.
™
Typical Setup
Note: Use only oil-free,
clean, dry filtered air.
Five micron filter
regulator
#2000F755
Power Purge
White quick-connect
Air tee
#1116
VALVEMATE
6000
VALVEMATE
6000 controller
Shutoff valve
To exhaust To pressurize
Flexible air line
#2310S
Fluid feed hose
5
20
0
EFD 752V-UH-SS
Fluid dispense
valve
Black quick-connect
Pressurized reservoir
with air regulator
(1.0 liter tank shown)
Pressure relief valve
Material
Constant air
Pulsed air for valve operation