Sink dimensions (All internal measurements unless otherwise stated)
Fig.1 Width of sink minimum: 13
7
/8", Front to back of sink minimum: 12" Internal
depth of sink minimum (for all taps): 4"
7
/8"
(External measurement of vessel/pedestal sink)
Fig.3 Minimum dis tance from center of horizontal arm to top of sink (AB11 only) 4". Front edge of sink (all types – p edestal, recessed, slab) to wall minimum 4".
Fig.4 Minimum distance between tap center and a side wall 11
1
/2".
Multiple taps should have a minimum distance between tap centers of 23".
Tap mounting
The tap stem (measured from the outside diameter) should be mounted
1
/2" - 1 1/2" from the outside edge of the sink. (Fig.2)
There should be a minimum of 11
1
/2" between a tap center and a side wall. When multiple taps are installed side-by-side, tap centers should be a minimum of 23" apart. This allows sufficient space for mounting the motor bucket, as well as sufficient shoulder room for users. (Fig.4)
Sink specification guidelines
Using a specially designed test method, Dyson engineers tested a wide range of sinks to assess their compatibility with the Dyson Airblade Tap hand dryer. For recommended sinks, please use our guide at www.dyson.com/docs
Porcelain or brushed metal sinks are ideal.
Sinks with highly polished surfaces should be avoided e.g. reflective chrome.
350mm minimum
300mm minimum
200mm maximum
385mm minimum
100mm minimum
200mm maximum
Fi g.1
200mm maximum
Fig.2
Fig.3 Fig.4
13 7/8" minimum
12" minimum
7
7
/
8
" maximum
4" minimum
15 1/8" minimum
1
/2" - 1 1/2"
Dia. 1
3
/8"
23" minimum 11
1
/2” minimum
4" minimum
WWW.RESTROOMDIRECT.COM 7049372673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Soap and locating the soap dispenser
For best user experience, Dyson recommends the use of gel soaps.
The infrared sensing zone for air activation extends along each tap branch. In order to prevent accidental activation, it’s important to consider the user’s hand route to the soap dispenser.
The dispenser should be located at least 2
3
/8" outside the width
of the tap, so the user reaches around the side of the branch.
It should also be located at least 2
3
/8" above the branches,
so that the sensors are not activated.
Please note that the user may reach diagonally across for the soap, so this path must not go through the sensing zone.
Front on view showing soap disp enser clear zone
Over head view showing soap disp enser clear zone
2
3
/8"2 3/8"
2
3
/
8
"
2 3/8" 2 3/8"
2
3
/
8
"
Tap mounting
Do not place the downward facing water sensor of the tap over a reflective surface, such as the drainage hole. (Fig.5)
For complete instructions, please refer to the printed installation guide supplied with the machine. It’s also available online at w ww.dyson.com/docs
Fig.5
AB09 AB10 9 1/2"
AB11 12"
For further information please contact Dyson.
1-888-397-6622 www.dyson.com
Dia. 1 3/8"
WWW.RESTROOMDIRECT.COM 7049372673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Base to back and front wall transition
The base to back and front wall transition should also be considered. The back wall should be as close to 90°, and at as sharp a radius as possible (Fig.8). Curved geometry is more likely to increase splashback, whereas sloping back and front wall transitions should be avoided (Fig.9 & 10).
Water drainage
Due to high velocity air and water being in close proximity, there is a chance of some water and soap dispersion outside the sink dimensions. To alleviate this effect, we recommend following the below guidelines.
Base Profile
Flat base profile will result in poor drainage leading to high levels of splashback.
To improve drainage, avoid sinks with a flat base with particular focus on the immediate area surrounding the drain hole, minimum 2
3
/8" radius (Fig.7).
Vertical and sharp transition
Vertical and smooth transition
Sloped transition
Minimum of 6° ramp angle from the edge of the drain hole of the sink will result in good drainage leading to reduced levels of splashback (minimum 2
3
/8" radius).
Fig.6
Fig.8
Fig .9
Fi g .10
Fig.7
2 3/8"2 3/8"
2
3
/8"2 3/8"
X
X
WWW.RESTROOMDIRECT.COM 7049372673 129 Oakpark Dr., Unit A, Mooresville, NC 28115