This product is CE marked in accordance with the CE directive and is designed to conform with
the following international standards:
Safety – BSEN 60950
- EN 61000-4-2 (1995)
- EN 61000-4-3 (1995)
- ENV 50204 (1995)
- EN 55022 (1994) + amendment 1 (1995)
- FCC Class B (part 15)
* Although unlikely, it is possible that abnormal behaviour may result from electrostatic
discharges. In such cases, should normal operation not resume, follow the relevant procedure as
detailed in the trouble-shooting section: No response to keys.
The user should avoid directly touching the thermal print head.
IEC 950
UL 1950
© 2000 Esselte N.V., Industriepark-Noord 30, 9100 Sint-Niklaas, Belgium
Visit our website (www.dymo.com) for information
on obtaining tapes and accessories for the LetraTag.
Power Supply
• Insert six size AA batteries, as shown in
Fig. A.
• Remove batteries if the Labelmaker is to be unused for some time.
Inserting the cassette
• The Labelmaker uses paper, plastic and metallic labels.
• Insert cassette as shown in Fig. B and press until it "clicks" into place - Fig. C.
• Check that the cassette is correctly located before closing the access door.
The Display
• Shows up to 6 characters plus cursor and 6 indicators ▲ as shown below.
Indicators show whether a feature is selected.
GB
CAPS
▲
STYLE
▲
▲▲
123456
CAPS = capital letters = box/underline STYLE = outline/italic etc.
123
= number lock = shift key
123
B
▲
▲
Function keys
ON/OFF
Switches the power on and off.
• Switches off automatically after two minutes if no keys are pressed. The last
label will be retained automatically in memory.
Note: If the batteries are removed for more than a few seconds, the memory will be lost.
by the
CAPS
CAPS
indicator in the display.
CAPITALS
• Press for all subsequent characters in UPPER CASE (CAPITALS), as confirmed
• Press again to cancel and return to lower case.
SHIFT KEY
• Press before pressing a number, punctuation or function indicated above a
key.
DELETE
DEL
• Press to delete the character to the left of the cursor or to exit function menus.
L
E
C
A
R
CLEAR
+
DEL
• Press to clear all the text but leave the settings unchanged.
CURSOR KEYS
or
• Press to move the cursor along the text, one character at a time.
• Press
• When used in conjunction with certain function keys, use
options.
+ or to move the cursor to the beginning or end of the text.
or to select
SPACE
• Press to insert a space into the text.
SIZE +
SIZE
K
• Press to display the three text print sizes:
CAPS
STYLE
123
B
▲
condensed normal extended
B
BOX/UNDERLINE +
L
• There are seven options available under the BOX/UNDERLINE feature:
1. Normal - = DYMO
2. Underlined -
3. Round Corners -
4. Shaded Box - =
5. Toothed Box - =
6. Crocodile Box - =
7. Pointed Box - =
= DYMO
=
DYMO
DYMO
DYMO
DYMO
DYMO
• Use or to move the cursor under the desired option. Press OK.
STYLE
STYLE
+
M
• There are five options available under the STYLE menu.
CAPS
• Place cursor under required STYLE and press
STYLEB123
Normal
Outline
Shadow
Italic
Vertical
OK
.