Druck SPX3000 Data sheet

Industrial Pressure Transmitters
PRESSURE
INSTRUMENTS
SPX 3000 Series
The SPX 3000 Series combines modular design with the latest advances in ASIC technology and surface-mount electronics. This provides a light­weight, highly reliable and cost-effective solution for a range of industrial pressure measurement applications including factory automation, equip­ment monitoring and control, gas turbines, and any other application where high-reliability is impor­tant. The rugged design with exceptional RFI/EMI immunity gives the SPX 3000 the lowest “cost-of­ownership” in the industry.
At the heart of the transmitter is piezoresistive silicon technology , extensively proven in aerospace, sub-sea, oil-field and many other applications where the highest levels of performance and long­term reliability are required.
The sensor features a Hastelloy C276 isolation diaphragm and is enclosed in an electron-beam welded 316L stainless steel body. This rugged con­struction ensures full compatibility with a wide range of pressure media and operating conditions.
On-site trimming of the transmitter output is accomplished via non-interacting potentiometers located beneath the electrical connector. The SPX 3000 offers the latest advancements in sensor tech­nology from SI Pressure continuing our tradition of superior performance at unbeatable prices.
Features
• Best performance-to-value on the market
• Any range between 1.5 and 10,000 psi
• ±0.15% FS accuracy
• NACE compatible Hastelloy C276 and 316L SS
• RFI/EMI protected to CE Heavy Industrial Standard
• Exceptionally rugged and lightweight
FM
APPROVED
SPX 3000 Series Specifications
Pressure Measurement
Operating Pressure Ranges
Proof Pressure (Overpressure)
Burst Pressure
Pressure Media Compatibility
Supply Voltage
Warmup Time Response Time Supply Sensitivity Insulation Resistance Surge Protection
(between connectors & case)
Output
Any pressure unit and (zero-based) span avail­able between 1.5 psi and 1000 psi gauge; between 1001 and 10,000 psi sealed gauge and between 5 and 10,000 psi absolute Compound ranges: -15 to 15, -15 to 30,
-15 to 100, -5 to 5 psi g
Alternate pressure units may be specified on order
6X FS for ranges 7.25 psi & below 4X FS for ranges 30 psi & lower 3X FS (3000 psi max) for ranges 2000 psi & lower 2X FS (15,000 psi max) for ranges 10,000 psi & lower
8X FS for gauge ranges 7.25 psi & lower 6X FS for gauge ranges 30 psi & lower 4X FS (3500 psi max) for ranges 1000 psi & lower 3500 psi for absolute ranges 2000 psia & lower 15,000 psi for ranges above 2000 psi
Fluids compatible with a welded assembly of Hastelloy C276 and 316L SS (NACE MR-01-75 compatible grades)
9 to 30 Vdc at the transmitter terminals (9-28 Vdc for IS units)
Maximum load ()=50X (V
500 ms max at power-up 1 msec
0.005% FS/volt
>10M@ 500 Vdc (@68°F)
Ranges up to 2000 psi withstands 2kV spike Ranges above 2000 psi withstands 1kV spike
2-wire, 4-20mA
Supply
-9)
Physical
Pressure Connection
Electrical Connection
Weight Mechanical Shock
Vibration
Dimensions in inches
Wiring Details +EXC -EXC Ground
Case SPX 3001 Red Black Shield SPX 3002 PINA PIN B PIN F SPX 3003 PIN 1 PIN 2
1/4" NPT female
Optional adapters available
3 feet integral cable (longer lengths available) 6 pin bayonet connector DIN 43650A plug/socket
For gauge ranges up to 1000 psig SPX 3001 and SPX 3003 require vented cable
7 oz. nominal 1000g half sine wave, pulse duration 1ms and
100g peak half sine wave, duration 11ms, both in each of 3 mutually perpendicular axes will not affect calibration
Conforms to MIL-STD 810C, Method 514.2-2 Curve L
SPX 3003
SPX 3002
SPX 3001
Performance
Accuracy
Zero Offset and Span Setting
Long Term Stability Operating Temperature Range
Temperature Effects
CE Conformity
Intrinsic Safety Approval
±0.15% combined non-linearity, hysteresis and repeatability FS BSL
Factory set ±0.05mA. Further ±5% FS user adjustment available via non-interacting potentiometers
±0.1% FS/year
-40 to 210°F for non-cabled models
-40 to 175°F for SPX 3001 ±1% FS TEB over 15 to 125°F
±2% FS TEB over -5 to 175°F EMC Emissions: EN50081.1, EN55022
EMC Immunity: EN61000-6-2
10V/m Heavy Industrial
FM Class I, Div 1, Groups A,B,C,D
Ordering Information
SPX300 - -
Box A: Electrical Connection
1 = Integral cable $ 340 2 = 6-pin bayonet $ 375 3 = DIN 43650A plug/socket $ 340
Box B: Pressure Range
Specify required pressure range in psi*, for example: 00050 = 50 psi N/C 03000 = 3,000 psi N/C
Box C: Options
0 = None N/C 1 = 5-Point NIST calibration certificate $ 150
A B CBB B B
Specifications may change without notice.
* Other engineering scales available. Consult factory.