STANDARD SPECIFICATIONS
Pressure Measurement
Operating Pressure Ranges
Any Full Scale (F.S.) between 0.625 mH2O to 700 mH2O gauge
Standard Pressure Ranges
The standard Upper Range Limit (URL) can be customer configured to
any intermediate range determined by the Range Adjustment Limits
0 to 2.5 mH
2
O gauge (URL)
0 to 5 mH
2
O gauge (URL)
0 to 10 mH
2
O gauge (URL)
0 to 15 mH
2
O gauge (URL)
0 to 20 mH
2
O gauge (URL)
0 to 35 mH
2
O gauge (URL)
0 to 50 mH
2
O gauge (URL)
0 to 100 mH
2
O gauge (URL)
0 to 150 mH
2
O gauge (URL)
0 to 350 mH
2
O gauge (URL)
0 to 700 mH
2
O gauge (URL)
Sensors can be provided with a pressure calibration at a downranged
F.S., (e.g., 17 mH
2
O) at an additional cost (refer to Option C).
Other units can be specified e.g. mmH
2
O, ftH2O, inH2O, mbar, psi, bar
Range Adjustment Limits
Downranging (4:1) - full 4 to 20 mA output change for any user span
setting up to the Upper Range Limit (URL) from 25 to 100% (URL).
Reverse (20 to 4 mA) - output can be inverted to generate a negative
going output with positive going level, e.g., 0 to 10 mH
2
O range
provides a 20 to 4 mA output as a power saving feature.
Elevation - the 4 mA output can be elevated within 0 to 75% of the
Upper Range Limit (URL) e.g., 0 to 40 mH
2
O range can be elevated up to
30 to 40 mH
2
O, with corresponding 4 to 20 mA output e.g for water
tower applications.
Overpressure
Standard Pressure Ranges (URL) can be exceeded by the following
multiples with negligible effect on performance:-
6 x for ranges to 2.5 mH
2
O
4 x for ranges above 2.5 mH
2
O (1400 mH2O max)
Pressure Containment
10 x for ranges to 2.5 mH
2
O
6 x for ranges above 2.5 mH
2
O (1400 mH2O max)
Media Compatibility
Fluids compatible with 316 stainless steel (body), acetyl (nose cone) and
polyurethane (cable assembly).
Excitation Voltage
10 V to 30 V
Minimum supply voltage (V min) which must appear across the level
transmitter terminals is 10 V and is given by the following equation:V min = V sup - (0.02 x R loop)
Where V sup is the supply voltage in volts, R loop is total loop resistance in ohms
Pulse Power Excitation
Recommended power-on time before output sample taken is 600 msec.
Output Signal
4 to 20 mA proportional to the level input in normal operation.
3.8 to 20.5 mA proportional to the Loop Cal input in Remote
Configuration Software (RCS) operation.
STANDARD SPECIFICATIONS
Performance Specification
Accuracy
The combined effects of Non-Linearity, Hysteresis and Repeatability on
standard pressure ranges (URL)
Standard: ±0.1% FS BSL max
Option A: ±0.06% FS BSL max
Zero Offset and Span Setting
Customer controlled with Remote Configuration Software (RCS).
Long Term Stability
0.1% URL per annum (0.2% for ranges below 5 mH
2
O)
Operating Temperature Range
Direct mount: -40° to 85°C
Fluid immersed: -10° to 80°C
Temperature Effects
+/- 0.1% URL (TEB) over -10° to 50°C
+/- 0.2% URL (TEB) over -40° to 80°C
Shock and Vibration
MIL-STD-810E, method 514.4., Category 10 min., Figure 514.4-16
The product will withstand 20g peak shock half sine wave, 9 mS
duration in all axes, also 2000g peak shock 0.5 mS duration in all axes.
Insulation
>10 M at 500 Vdc.
EMC
CE marked: EN61326-1
Software
Remote Configuration Software (RCS) provided free of charge with each
sensor, along with installation, maintenance and application instructions.
Physical Specification
Pressure Connection
G1/4 female fitted with detachable nose cone assembly, applicable for
direct mount or immersed applications.
Electrical Connection
Vented polyurethane cable with integral Kevlar strain relief cord rated to
54 kg load. Water ingress protection to IP68 to 700 mH
2
O.
Analogue 4 to 20 mA - 2 wires
Isolated digital interface - 4 wires (suitable for transmission up to 500
metres of cable).
Each unit provided free of charge with female Bulgin Buccaneer,
splash-proof connector for use with PC Configuration Interface Module
(Option B).
Cable Lengths
To be specified as required in 1 metre increments up to 500 metres.
Documentation
Units provided with traceable calibration certificate.