Detcon 812B User Manual

detcon inc.
Detcon
Model 812B
Rack Mount Control Enclosure
Operator’s Installation & Instruction Manual
March 1, 1999 Document #2079 Ver. 1.1
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
ALARM 3
ALARM 2
ALARM 1
ALARM RESET/
Test
HOUSTON, TEXAS
detcon inc .
able
disable
ALARM
MODEL 12B
HYDROGEN
SULFIDE
MONITOR ppm H2S
HOUSTON, TEXAS
detcon inc.
POWER
ON/OFF
FUSE
2 AMP
Model
PS80-12B
FUSE
PRESS
M
odel
812B
HOUSTON, TEXAS
detcon inc.
Table of Contents
1.0 Introduction
1.1 Description
1.2 Specifications
1.3 Schematics
1.4 Installation
1.5 Start-up
1.6 Maintenance & Repair
1.7 Spare Parts List
1.8 Warranty
1.0 INTRODUCTION
Detcon Model 812B consists of 3 major assemblies:
1. The NEMA 1 rack mount control enclosure.
2. The single channel digital control modules.
3. The remote mount gas sensor assemblies.
The NEMA 1 control enclosure is detailed in section 1.0 of the manual, the control modules in section, 2.0 and applicable sensor assemblies in section 3.0.
1.1 D
ESCRIPTION
Detcon Model 812B rack mount control enclosure, along with Model 12B digital control modules, is designed to serve as a host assembly for up to eight remote mount gas detection sensor assemblies. The control enclosure is rated NEMA 1 suitable for installation in non-hazardous locations.
The single channel modular design supports application f lexibility wherein multiple function gas detection systems can be configured in any combination up to eight channels. All control modules are plug-in front panel accessible for easy maintenance and repair. The system is powered by VAC line power and/or 24VDC unless otherwise speci­fied at time of order.
The control enclosure houses a modular power supply (Model PS80-12B) which includes, as standard operating con­trols, a power on/off switch and a line power fuse. Discreet output terminal strips located on the controller mother­board are provided for sensor terminations, Form C dry contact alarm outputs for three alarms plus fault (common and choice of normally open or normally closed), 4-20 mA outputs for remote recording devices, and RS-485 serial Modbus™ output. Additional terminations are provided for VAC power in, VDC power in, and remote alarm reset.
The Form C relay outputs, may be discreet, zoned, or common by gold plated jumper tabs located on the con­troller mother board.
1.2 SPECIFICATIONS
Electrical Classification
NEMA 1
Dimensions
19''W x 7''H x 8.75''D
Capacity
8 single channels
Power Input
117VAC/24VDC
PPoowweerr CCoonnssuummppttiioonn
5 watts per channel (full alarm peak load)
Model 812B Rack Mount Control Enclosure PG.2
Model 812B Rack Mount Control Enclosure PG.3
OOuuttppuuttss
Discrete Analog 4-20 mA DC Serial RS-485 Modbus™
AAllaarrmm RReellaayyss
(discrete or zoned)
Contacts include common with jumper selectable choice (on controller) of normally-open or normally-closed for four alarms
Resistive load: 5A, 250 VAC; 5A, 30 VDC Inductive load: 2A, 250 VAC; 2A, 30 VDC Max. operating current: 5A
OOppeerraattiinngg TTeemmppeerraattuurree RRaannggee
-40°F to +175°F
WWaarrrraannttyy
One year
1.3 SCHEMATICS
A
B
C
D
E
F
H
J
K
L
M
N
P
R
S
T
U
V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
mA
Sensor
NO/NC
Com
Alm 3
NO/NC
Com
Alm 2
NO/NC
Com
Alm 1
NO/NC
Com
Fault
4-20mA
Out
Typical
Connector
x 8
Typical
Jumpers
x 7
CH8 CH7
P8 thru P1
Typ. x 8
Alarm
Reset
P9
L1
N
A (+)
B (–)
Shld
RS-485 VDC In
GND
VAC In
P10
P11
P12
P13
812B
Motherboard
Schematic
L1
N
GND
+ In
– In
+ Out
– Out
1.4 INSTALLATION
1. Securely mount the 812B enclosure in accordance with the drawing in figure 1.
NNoottee::
Reference figure 2 for wiring terminations.
2. Connect 117VAC input to the terminal strip labeled “VAC IN” (L1, N, GND).
3. If applicable, connect a 24VDC source or standby battery to the terminal strip labeled “VDC IN” (+ and –).
4. Refer to installation and wiring detail of remote mount sensor assemblies as detailed in section 3.0. Terminate field wiring from sensors to the 812B motherboard. Terminals are labeled “SENSOR” (MA, + and —).
5. If applicable, terminate the discrete 4-20 mA outputs to external device(s). Terminals are labeled “4-20 mA OUT” (+ and —).
6. If applicable, terminate the RS-485 serial output to external device(s). Terminals are labeled “RS-485” (A+, B–, and Shield).
Model 812B Rack Mount Control Enclosure PG.4
PS80-12B Power Supply Schematic/Wiring Diagram
BLK
RED
Power Supply DC Out
P2
Power
Switch
P3
16ga x 6"
16ga x 6"
BLK 16ga x 9"
BLK 16ga x 9"
TAN 22ga x 9"
TAN 22ga x 9"
RED 16ga x 9"
RED 16ga x 9"
TB2
Pin 5 Com
Pin 7 +
Power Supply
Pin 1
Pin 2 N
Pin 3 L
D1 6A 50V
TB1
D2 6A 50V
16ga x 6"
16ga x 6"
16ga x 6"
Power Supply VAC In
GND - GRN
N - WHT
L1 - BLK
P1
L1 In N In GND In +DC In –DC In +DC Out –DC Out
P5
Fuse
P4
16ga x 9"
BLK
BLK 16ga x 9"
7. Based on the application and use of relay contact outputs, complete all wiring terminations prior to application of power. Shut-in controls may be omitted until system test is complete. Terminals are labeled “ALARM 1”, “ALARM 2”, “ALARM 3”, and “FAULT” (COM & NO/NC). Relay contact outputs may be discreet or zoned via the gold-plated jumper tabs.
8. If applicable, terminate a remote mounted normally open momentary switch to the terminations labeled “Alarm Reset”. Activation of the alarm reset function will reset the alarms of all Model 12B controllers. The reset func­tion is effective when the Model 12B’s respective alarms have been programmed in the latching position and alarm conditions have passed. Each Model 12B controller has its own alarm reset switch which is discussed fur­ther in section 2.0.
Model 812B Rack Mount Control Enclosure PG.5
Alarm
Reset
L1
N
A (+)
B (–)
Shld
RS-485 VDC In
GND
VAC In
Zone Programming Jumpers
mA
Sensor
NO/NC
Com
Alm 3
NO/NC
Com
Alm 2
NO/NC
Com
Alm 1
NO/NC
Com
Fault
4-20mA
Out
CH8 CH7 CH1
Figure 2
Figure 1
Panel cutout (centered) 17.5 x 6.65
Panel depth - 8.75
3
7
.375
.218
Slot Detail use 10-32 screw
19
1.5 START UP
Upon completion of all field wiring: Depress the power switch located on the front panel. Note that each Model 12B controller digital display illuminates. Varying readings may occur during sensor warm-up. A 10 second alarm delay will occur on power up. Refer to section 3.0 for additional sensor start-up detail.
1.6 MAINTENANCE & R
EPAIR
The Detcon Model 812B’s modular design allows for minimum down time during maintenance and/or repair. A model 12B control module may be changed by simply loosening its mounting screw and sliding the module out of its card cage. See section 3.0 for more information on the 12B control module.
The Model PS80-12B 80 watt power supply can be replaced by first loosening its two mounting screws and then sliding it out of the panel. A new power supply can then be installed or the existing one repaired. It is recommend­ed that VAC and VDC power be removed from the 812B motherboard before doing maintenance on, or replacing the power supply.
Replacement of the power switch, or fuse holder is accomplished by: removing the power supply from the panel; disconnecting the plug from its respective header; remove the wires from the plug of the component to be replaced; snap the component out of the PS80-12B face plate and then reassembly with the new component. Reference the PS80-12B schematic/wiring diagram in section 1.3 for wiring details.
Replacement of the power supply itself is accomplished by: removing the PS80-12B power supply module from the panel; disconnecting the four plugs from their respective headers; removing the 3 screws that secure the PS80-12B face plate to its bracket; removing the 4 screws that mount the power supply to the bracket; disconnect the wires from the power supply and then reassembly with the new power supply. Reference the PS80-12B schematic/wiring diagram in section 1.3 for wiring details.
1.7 SPARE PARTS LIST
Par
t # Description 0224 Gold plated jumper tab 951-5880-121 PS80-12B 80 watt modular power supply (this is the complete plug-in power supply module) 360-801024 80 watt, 24 VDC switcher power supply (replacement power supply for PS80-12B) 2812 24 VDC lamp for power switch 0298 2 amp 3AG slow blow fuse 320-3217-1 Power switch assembly 2806 Green switch cap (for power switch) 3280 Fuse holder
1.8 WARRANTY
Detcon Inc., as manufacturer, warrants under intended normal use each new Model 812B rack mount control enclosure to be free from defects in material and workmanship for a period of one year. The warranty period begins from the date of shipment to the original purchaser and ends one year thereafter. All warranties and service policies are FOB the Detcon Inc. facility located in The Woodlands, Texas.
Model 812B Rack Mount Control Enclosure PG.6
Shipping Address: 3200 A-1 Research Forest Dr., The Woodlands, Texas 7381
Mailing Address: P.O. Box 8067, The Woodlands, Texas 77387-8067
phone 888-367-4286, 281-367-4100 • fax 281-292-2860 • www.detcon.com • sales@detcon.com