DELTA DORE D10 W RF Installation Instructions Manual

-+
MODE
D10 W RF
Wireless thermostat for heating control
Installation instructions
Delta Dore hereby declares that the equipment complies
of the R&TTE Directive 1999/5/EC.
The EC declaration of conformity for this equipment is available,
on request, from:
“Technical info”depar tment
DELTA DORE - Bonnemain - 35270 Combourg (France)
Email: info.techniques@deltadore.com
Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed.
*2702706_rev.1*
• Carefully read these instructions prior to installation.
• The unit must be installed in compliance with current standards.
• Always switch off the mains before installing or servicing the unit.
• Do not attempt to repair the unit yourself; after-sales service is available.
• Check that the fastenings are suitable for the surface to which the unit will be mounted (plasterboard, brick, etc.).
• The diagrams provided are simplified for greater clarity. Protections and other accessories required by standards are not illustrated. Standards and good practice must be complied with. Connected or nearby units must not generate excessive interference
(Directive
2004/108/EC)
.
1. Installing the RF 810 receiver
2. Connecting the RF 810 receiver
NL123 4
230V~
50-60 Hz
3A max. / 230V~
2721318 Rev.1
CH OFFCHON
Cons. 11 VA P = 1,2 W
NL1 23 4
230V~
50-60 Hz
3A max. / 230V~
2721318 Rev.1
CH
OFFCHON
Cons. 11 VA P = 1,2 W
2
3
4
1
5
6
Technical characteristics
Transmitter D10 RF
• Power supply:2 LR03-AAA type 1.5 V alkaline batteries
• Insulation class: class III
• Transmission frequency 868 MHz (Standard EN 300 220)
• Class 1 radio equipment (can be placed on the market and put into service without any restrictions)
• Radio range: 100 to 300 metres outside, varies depending on the equipment linked (the range can be altered depending on the installation conditions and the electromagnetic environment)
• Wireless remote control device
• PI (Proportion Integral) regulation
• Storage temperature: -10 °C to +70 °C
• Operating temperature: 0 °C to +40 °C
• Dimensions: 80 x 80 x 23 mm
• Protection rating: IP30
• Installation in an environment with normal pollution levels
Receiver RF 810
• 230 V, 50 Hz power supply, +/-10%,
• Consumption: 11 VA (P=1.2 W)
• Class II insulation
• Contact output 3 A max., 230 V Cos ϕ= 1
• Automatic action: 1.C (brownout),
• Radio frequency 868 MHz (standard EN 300 220)
• Wireless range: 100 to 300 metres outside, variable
depending on the associated equipment (the range can vary depending on the installation conditions and the electromagnetic environment)
• Storage temperature: -10 °C to +70 °C
• Operating temperature: 0 °C to +40 °C
• Installation in an environment with normal pollution levels
• Screw mounting (standard Wallplate)
• Dimensions: 96 x 96 x 39 mm
• Protection rating: IP 40
NL1 23 4
230V~
50-60 Hz
3A max. / 230V~
CH
OFFCHON
NL
NL1 23 4
230V~
50-60 Hz
3A max. / 230V~
CH
OFFCHON
NL
Circulator pump
Example 1 230V powered output
Example 2 Dry contact output
Boiler
thermostat
input
~1,50 m
Mini 20 cm
A
A
B
B
1
1
2
2
3
4
5
6
3. Positioning the Radio D10
6. Troubleshooting
Nothing is displayed on the transmitter screen.
There is no power supply.
Check the batteries.
No LEDs light up on the receiver.
The receiver is not powered.
Check the receiver’s electrical connections.
The receiver does not accept commands from the transmitter.
• The transmitter is not associated with the receiver.
Repeat the association procedure.
• The transmitter batteries are low.
Change the transmitter batteries.
• Radio transmission is not optimal.
Transmission quality depends on the installation conditions and environment (type of wall, location, etc.).
The icon appears.
Battery level is low.
Change the batteries, ensuring they are in the correct position.
5. Configuring the Radio D10
4. Associating the Radio D10 transmitter with the receiver
-+
MODE
> 3"
> 3"
1
2 3
-+
MODE
5
OK
... ... ...
-
+
MODE
MODE
6
+
-+
MODE
7 8
9
+
-+
MODE
4
-+
MODE
> 10"
+ 0,5°C
- 0,5°C
1
MODE
MODE
+
-+
MODE
2 3
+
-
-+
MODE
4 5
MODE
-+
MODE
6
+
7
MODE
-+
MODE
8
MODE
-+
MODE
9
+
Continuous display of the
room temperature
Continuous display of the
temperature setting
Correcting the temperature measured (-5 °C to +5 °C)
Keypad unlocked
Mandatory
Keypad locked
(settings, mode)
The transmitter and the receiver are associated when delivered. You may however need to reassociate your products (after removing wireless associations for instance).
NOTE:You can manually reset the receiver by pressing the button of the channel to associate for 10 seconds until the LED flashes rapidly.
Loading...