DeLonghi PAC W130E User Manual

P AC W130E
WATER/AIR AIR CONDITIONER
Instructions for use
Keep these instructions
CLIMATISEUR EAU-AIR
Mode d'emploi
Conservez cette notice
Instrucciones para el uso
Repase y guarde estas instrucciones
Lea cuidadosamente este instructivo
antes de usar su aparato
CONDIZIONATORE ACQUA/ARIA
Istruzioni per l’uso
Leggere e conservare queste
istruzioni
ELECTRICAL SPECIFICATIONS 115V ~ 60Hz
DONNEES ELECTRIQUES 115V~60Hz
CARACTERISTICAS ELECTRICAS 115V ~ 60Hz
CARATTERISTICHE ELETTRICHE 115V~60Hz
Register this product on-line and receive a free trial issue of Cook's Illustrated. Visit www.delonghiregistration.com. Visit www.delonghi.com for a list of service centers near you. (U.S. Only)
Enregistrez ce produit en ligne et recevez un numéro gratuit de Cook's Illustrated. Visitez www.delonghiregistration.com. Visitez www.delonghi.com pour y voir une liste des centres de réparation proches de chez vous. (É.-U. uniquement)
Registre este producto en línea y reciba un ejemplar gratis de Cook's Illustrated. Visite www.delonghiregistration.com. Visite www.delonghi.com para ver la lista de centros de servicios cercanos a usted. (Solamente en los Estados Unidos)
Registra questo prodotto "on-line" per riceve­re una copia omaggio della rivista. Visita www.delonghiregistration.com. Visita www.delonghi.com per una lista dei centri di servizio a te piu vicini. (Solo negli Stati Uniti)
IMPORTANT SAFEGUARDS
• Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many eventualities as possi­ble. Caution and common sense should be used when operating and installing this air con­ditioner.
• This appliance has been manufactured to cool and dehumidify domestic environments and should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
• Should repairs be necessary, contact the nearest authorized De’Longhi Repair Service Center. Unauthorized Delonghi servicing can be dangerous.
• This appliance is to be used by adults only; keep away from children.
• In the case that the power cord becomes damaged, this must be substituted only by spe­cialized personnel authorized by the manufacturer, to protect against fire.
• Always ensure the appliance is grounded. If you have any doubts check with a qualified electrician.
•We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-wire grounded extension cord, attachment plug and connector, rated 15A, 125V.
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
• Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Clean the filters at least once a week.
•Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.
• Before transporting the unit, drain the unit. After transportation, wait at least 4 hours before switching the unit on.
• The packaging materials can be recycled. It is recommended to place them in the special containers for differentiated waste collection.
• This appliance is fitted with a special safety device. When the compressor switches off, this device prevents it from switching on again for at least 3 minutes.
• Remember to descale the appliance at the end of every season and always after 500 hours of operation (see page 17). In areas with particularly hard water, you are recommended to add special water softener obtainable from authorized service centers to the water.
SAVE THESE INSTRUCTIONS
THIS PRODUCT IS FOR HOUSEHOLD ONLY
2
ELECTRICAL CONNECTIONS
Before plugging the appliance into the electrical socket, check that.
• the power supply corresponds to the value indicated on the rating plate on the back of the appliance.
• the socket and electrical circuit are adequate for the appliance.
• the socket matches the plug. If this is not the case, have the plug replaced.
• the socket is adequately earthed.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The power cable must be replaced by a qualified professional only
3
WHAT IS THE WATER-AIR PINGUINO
During the summer, you feel comfortable at a temperature of between 75°F and 81°F (24 and 27° C) with a relative humidity of about 50%.
An air conditioner removes excess moisture and heat from the room where it is located. Compared with installed models, portable air conditioners have the advantage that they can be moved from one room to another in the home or be transported from one building to another.
Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moisture are removed before the air is re­emitted into the room.
In single duct models, a small part of this air is used to cool the refrigerant gas and then, when hot and damp, is discharged outside.
In exclusive De'Longhi water-air models, the heat is removed from the room through the cooling effect of the water which is obviously much greater than air.
This gives this air conditioner unbeatable cooling efficiency.
4
DESCRIPTION
A Air outlet grille B Control panel with advanced LCD display C Handle D Grille E Castors F Air intake grille with dust filter G Air exhaust hose housing H Water drainage hose door I Power cable compartment door J Water fill door K Air exhaust hose L Remote control M Water jug N Window outlet O Silver ion filter P 3M filter Q Suction pad with Velcro R Castor locks S Wall flange with cap T Single hole window bracket with locking
pins
U Window bracket extension
AA
AA
BB
FF
CC
DD
EE
JJ
II
GG
HH
KK
LL
MM
NN
OO
PP
QQ
RR
SS
TT
UU
5
PREPARING FOR USE
The instructions below will enable you to prepare your air condi­tioner for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unob­structed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with your appliance:
• Fit the air exhaust hose (K) in the housing (G) at the back of the appliance (fig. 1).
• Fit the window outlet (N) to the end of the hose.
• Place the air conditioner near a window or French window.
• Adjust the length of the air exhaust hose to reach the window.
• Make sure the air exhaust hose is unobstructed.
• Open the window or French window slightly and position the window outlet (fig. 2).
• If you have a double window, use the suction pad (Q) provi­ded to hold the two parts of the window together (fig. 3).
For optimum results:
• If you have a sash window, place the window bracket (T) on the window sill, extend the window bracket fully within the window frame, fix the window bracket by using the locking pin then lower the window onto the window bracket. Insert the window outlet (N) of the exhaust hose (K) into the slot, then connect the hose to the air conditioner (fig. 4).
• Thanks to the locking pins, it’s possible to use the window bracket also for sliding windows. Position the hole of the window bracket so to allow a correct installation of the exhaust hose (see figure 5).
• If the windows are large, use the window bracket extension (U) to cover your window aperture, extending it to the requi­red length, then blocking it with the locking pins supplied (see figure 6). Make sure you do not cover the hole for the window outlet.
Keep the air hose as short and free of curves as possible to avoid bottlenecks.
3
5
1
2
4
6
2
1
2
1
3
2
1
6
AIR-CONDITIONING WITH INSTALLATION
If required, your appliance can also be installed semi-perma­nently (Fig. 7). Proceed as follows:
• Drill a 4.17 inche (106 mm) diameter hole respecting the heights shown in fig. 8 and following the indications in figs. 9, 10 and 11.
7
10
8
9
In the window pane.
In the wooden kickboard
of a French window.
11
In the wall: it is
recommended that you
insulate the section of the wall using suitable
insulation.
• Fit the wall flange (S) into the hole.
• Fit the air exhaust hose (K) in the housing at the back of the appliance (fig. 1).
• Fit the end of the air exhaust hose to the wall flange as shown in fig. 8. When the air exhaust hose is not fitted, the hole can be closed with the flange cap.
Keep the air hose as short and free of curves as possible to avoid bottlenecks.
When installing the air conditioner semi-permanently, you should leave a door slightly open as little as 1/2(1cm) to gua­rantee correct ventilation.
11.8 in 30 cm
11.8 in 30 cm
MAX 39 in MAX100 cm
MIN 14 in MIN 35 cm
4.17 in
106
Loading...