Important safeguards
• This appliance is designed for home air conditioning and must not be used for other purposes.
• It is dangerous to modify or alter the characteristics of the appliance in any way.
• The appliance must be installed in conformity with legislation in force in the country concerned.
• If the appliance requires repair, contact a Service Centre authorised by the manufacturer only. Repairs carried out by unauthorised personnel may be dangerous.
• If the power cable is damaged, it must be replaced by a qualified professional authorised by the manufacturer only.
• This air conditioning unit must be used by adults only. Never allow children to play with the applian­ce.
• The appliance must be connected to an efficient earth system. Have your electrical circuit checked by a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance operations, always unplug the appliance from the mains socket.
• Do not move the appliance by pulling the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat. .
• Do not rest heavy or hot objects on top of the appliance.
• Clean the anti-microbial filters at least once a week.
•Avoid using heating appliances near the air conditioning unit.
• Always transport the appliance upright or resting on one side. Before moving the appliance, empty the internal circuit completely of water. Press the MODE (B) and FAN (T) buttons simultaneously for a number of seconds without removing the tank (8) and then empty the tank (8). After moving the appliance, wait at least 1 hour before starting it
• Use the appliance as described in this instruction manual only. As with any electrical appliance, while the instructions aim to cover as many eventualities as possible caution and common sense should be used when operating and installing this air conditioning unit.
• At the end of its working life, take the appliance to a special collection centre.
• The materials used for packaging can be recycled. You are therefore recommended to dispose of them in special differentiated waste collection containers.
• When putting the appliance away, do not cover with plastic bags.
• The refrigerant gases R290 and R407c conform to EC regulations on the environment. Avoid perfo­rating the refrigerant circuit of the appliance.
• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised containers (eg aerosol cans).
For environmentally-friendly models only (T90ECO, T100ECO)
• If the appliance is used in rooms without adequate ventilation, take the necessary precautions to avoid possible leaks of refrigerant gas stagnating in the atmosphere, creating a fire risk.
• This appliance must be used and kept in rooms with a volume of more than 21m
3
.
• If an appliance containing flammable refrigerant is used in an unventilated room, make sure the room is suitable and that there is no danger of gas leaks reaching a concentration which could cause fire or explosion in the presence of other heat sources (electrical heating appliances, heaters or similar).
DESCRIPTION 1
air outlet grille (motorised in model T100 ECO only)
2 control panel 3 castors 4 handles 5 air exhaust hose housing 6 condenser air intake grille 7 evaporator air intake grille 8 condensate tank 9 continuous condensate drain connection 10 power cable
11 flange cap 12 air exhaust hose 13 window outlet 14 suckers 15 castor locks 16 continuous drain hose with coupling 17 remote control unit (model T100 ECO only) 18 3M air purifying filter accessory (model
T100 ECO only)
GB-5751012500 14-04-2004 15:59 Pagina 17
18
During the summer, you feel comfortable at a temperature of between 24 and 27° C with a
relative humidity of about 50%. An air conditioning unit removes excess moisture and heat from the room where it is located. Compared with installed models, portable air conditioning units have the advantage that they can be moved from one room to another in the home or be transported from one building to another. Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moistu­re are removed before the air is re-emitted into the room. In single unit models (Pinguino), a small part of this air is used to cool the refrigerant gas and then, when hot and damp, is discharged outside. In models with case (Super­Pinguino), the circuit is coo­led using air from outside. All Pinguino and SuperPin­guino models can also be used in fan-only mode.
The Pinguino ECO is a latest generation environ­mentally-friendly air con­ditioning unit. The Pinguino ECO does not, in fact, con­tain gases (CFC/HCFC) dangerous to the ozone layer or with a marked greenhouse effect (HFC). As well as reducing energy con­sumption, the high efficiency of the appliance also minimises impact on the greenhouse effect.
What are the Pinguino and SuperPinguino?
GB-5751012500 14-04-2004 15:59 Pagina 18
19
ENGLISH
The instructions below will enable you to prepare your air conditioning unit for operation as effi­ciently as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with Pinguino:
• Fit the air exhaust hose in the housing
at the back of the appliance. Insert it as
shown in figure A.
5
12
• If you have a double window, use the suckers provided to hold the two parts of the window together (fig. C).
14
• Fit the window outlet to the end of the hose .
• Place the air conditioning unit near a win­dow or French window.
• Make sure the air exhaust hose is unob­structed.
• Open the window or French window sligh­tly and position the outlet as shown in figure B.
13
13
12
A
Preparing for use
B
C
Keep air hoses as short and free of cur­ves as possible to avoid constrictions.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
• the mains power supply corresponds to the value indicated on the rating plate on the back of the applian­ce;
• the mains socket and electrical circuit are adequate for the appliance;
• the mains socket matches the plug. If this is not the case, have the plug replaced;
• the mains socket is adequately earthed. Failure to follow these important safety instructions absolves the
manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
GB-5751012500 14-04-2004 15:59 Pagina 19
20
Preparing for use
AIR-CONDITIONING WITH INSTALLATION
If required, the Pinguino can also be installed semi-permanently.
• Fit the flange accessory provided in the hole
• Fit the hose in the housing at the back of the appliance (fig. A page 19).
• Fit the end of the hose to the flange
as shown in fig. E.
11
12
12
Proceed as follows:
• Drill a hole in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figure D.
When the hose is not fitted, the hole can be closed with the flange cap .
NOTE: When installing the air conditioning unit semi­permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.
11
12
in the window pane
in the wall: you are recommended to insulate the sec­tion of wall using suitable insulation.
in the woo­den socle of a French win­dow
E
F
DEHUMIDIFYING
Place the appliance in the room without fit­ting the hose. The dehumidified air will thus be released directly into the atmosphere. Cold air will be discharged from the front gril­le and hot air from the back grille (fig. G), thus guaranteeing efficient dehumidifying.
Keep the air hoses as short and free of curves as possible to avoid constrictions.
G
hot air
cold air
D
GB-5751012500 14-04-2004 15:59 Pagina 20
30 cm
106
30 cm
MAX100 cm
MIN 35 cm