Delonghi PACN 90E Instructions Manual

4
Important safeguards
• Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner.
• This appliance has been manufactured to cool and dehumidify domestic environments and must not be used for other purposes.
• The appliance must be installed in accordance with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho­rized servicing can be dangerous.
• The appliance is not intended for use by persons (including children) with reduced physical, sen­sory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
• In the case that the power cord becomes damaged, this must be repaired only by specialized per­sonnel authorized by the manufacturer in order to protect against fire.
• Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts check with a qualified electrician.
• We strongly discourage the use of an extension cord due to potential safety hazards.
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
• Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Clean the filters at least once a week.
• Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.
• Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before switching the unit on.
• The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection.
• This appliance is fitted with a special safety device. When the compressor switches off, this device prevents it from switching on again for at least 3 minutes.
WARNING: Changes or modifications not expressly approved by the party responsible for com- pliance could void the user's authority to operate the equipment.
SAVE THESE INSTRUCTIONS
THIS PRODUCT IS FOR HOUSEHOLD ONLY
DESCRIPTION 1 air outlet grille
2 control panel 3 castors 4 handles 5 filter 6 evaporator air intake grille 7 air exhaust hose housing 8 condenser air intake grille 9 power cable 10 drainage hose with black cap 11 wall flange
12 air exhaust hose 13 hose adaptor (2 pieces) 14 accessory for wall mounting 15 window bracket grille 16 window bracket cap 17 window bracket 18 additional window bracket 19 6 screws 20 window outlet 21 remote control
5
GB
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with your air conditioner:
• Screw one hose adaptor to the hose’s end .
• Fit the other hose adaptor in the air exhaust hose housing at the back of the appliance (see fig. A).
• Screw the other end of the hose to the adaptor, that was already fitted to the appli­ance (see fig. A).
12
7
13
13
A
Preparing for use
Sash window
• Attach the window bracket grille to the window bracket with the screws provided using a screwdriver, not included (fig. B).
19
17
15
B
• Open the window.
• Place the window bracket in the win­dow, extending it to fit the width of the window
(fig. C).
17
C
D
• Once the bracket is extended, it can be locked into his width by tightening the last two screws provided.
• Close the window (fig. D).
• Place the air conditioner near the win­dow. Insert the assembled exhaust hose
into the window bracket grille
(fig.
E). Make sure the air exhaust hose is unob­structed.
• When not used, the window bracket can be closed off with the cap provided.
16
17
12
Keep the air hoses as short and free of curves as possible to avoid constrictions.
E
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
• The outlet’s power supply corresponds to the value indicated on the rating label on the back of the appliance;
• The outlet and electrical circuit are adequate for the appliance;
• The outlet is a 3-hole grounded outlet . If this is not the case, you must choose another outlet.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unobstructed.
The power cable must be replaced by a qualified professional only.
• If you have a very large window, in order to cover your window aperture, use the additional window bracket without holes extending it to the desired dimension, then fix the bracket by using the pins pro­vided. When extracting the window bracket and joining the two pieces pay attention you do not cover the hole or holes (depending on the model).
6
Preparing for use
134
5,25 in.
When the hose is not fitted, the hole can
be closed with the flange cap .
NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.
11
12
in the window pane
in the wall: you are recommended to insulate the section of wall using suit­able insulation.
in the wooden kickboard of a French window
I
French window
• Attach the window outlet
to the air
exhaust hose as shown in fig. F.
20
G
• Open the French window slightly and posi-
tion the outlet as shown in figure G
20
Keep the air hoses as short and free of curves as possible to avoid constrictions.
F
SEMI-PERMANENT INSTALLATION
If required, your appliance can also be installed semi-permanently (Fig. H).
30 cm
30 cm 12 inches
12 inches
Proceed as follows:
• Drill a hole (ø134mm / 5,27 in.) in an out­side wall or through a window pane. Respect the height and dimensions of the hole given in figures M and I.
H
• Fit the wall flange into the hole.
• Screw the hose to the adaptor , that was already fitted to the appliance (fig. A).
• Remove the plastic end of the hose
by unscrewing it and in its place screw the wall mounting accessory
(fig. L).
• Fit the end of the hose to the wall
flange as shown in fig. M.
14
12
1312
11
11
12
L
M
MAX100 cm MAX 39 inches
MIN 35 cm MAX 14 inches
2
1
1
2
7
GB
H
C
D
THE CONTROL PANEL
I
L
M
Q
G
Control panel
DESCRIPTION OF THE CONTROL PANEL
A ON/OFF button B MODE selection button
Air conditioning, dehumidifying, fan.
C Fan speed selection button (MAX/MED/MIN) D Timer button E Programmed operation increase temperature/time button F Programmed operation decrease temperature/time button G Display Displays the temperature values set and the programmed operating time H Timer in operation indicator light I/L/M Fan speed lights N Fan mode light O Air-conditioning mode light P Dehumidifying mode light Q Alarm light R
Remote control receiver
S Light: the inner temperature is shown on the display T Light: the outdoor temperature is shown on the display
B
A
E
F
T
S
O
P
N
R
Never turn the air conditioner off by unplugging from the outlet. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to per­form a cycle of checks to verify operation.